FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Shenzhen HTT Technology Co., Ltd. Report No.: HTT202607400 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 1 of 4 Product Name: Panel Switch Model No.: P1-12S EUT Constructional Details External Photo Report No.: HTT202607400 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 2 of 4 Report No.: HTT202607400 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 3 of 4 Report No.: HTT202607400 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 4 of 4 ------End------
Label and Location Size: L: 3.0cm*W: 2.0cm Label and Location FCC ID : 2BW7Z-P1-12S
Shenzhen HTT Technology Co., Ltd. Report No.: HTT202607400 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 1 of 2 Product Name: Panel Switch Model No.: P1-12S EUT Constructional Details Internal Photo Report No.: HTT202607400 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 2 of 2 ------End------ ANTENNA
Shenzhen HTT Technology Co., Ltd. Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 1 of 8 RF Exposure MPE Report Reference No. ..................... : FCC ID............................................. : HTT202607400F02 2BW7Z-P1-12S Compiled by ( position+printed name+signature) . : File administrators Heber He Supervised by ( position+printed name+signature) . : Project Engineer Bruce Zhu Approved by ( position+printed name+signature) . : RF Manager Kevin Yang Date of issue .................................... : Jul. 16, 2026 Testing Laboratory Name .............. : Shenzhen HTT Technology Co.,Ltd. Address............................................ : 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao’an District, Shenzhen, Guangdong, China Applicant’s name ............................ : Hong Kong Xin Sheng Century Trading Co.,Limited Address............................................ : ROOM S032, 2/F, THE CAPITAL, 61-65 CHATHAM ROAD SOUTH, TSIM SHA TSUI, KOWLOON, HONG KONG Standard ........................................... : 47CFR §1.1310 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen HTT Technology Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HTT Technology Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HTT Technology Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Panel Switch Manufacturer .................................... : Hong Kong Xin Sheng Century Trading Co.,Limited Trade Mark ........................................ N/A Model/Type reference ...................... : P1-12S Rating ............................................... : DC 12-24V Result ............................................... : PASS Report No.: HTT202607400F02 Page 2 of 8 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 2 of 8 T E S T R E P O R T Equipment under Test : Panel Switch Model /Type : P1-12S Listed Models : P1-08S Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number is different for these model. Applicant : Hong Kong Xin Sheng Century Trading Co.,Limited Address : ROOM S032, 2/F, THE CAPITAL, 61-65 CHATHAM ROAD SOUTH, TSIM SHA TSUI, KOWLOON, HONG KONG Manufacturer : Hong Kong Xin Sheng Century Trading Co.,Limited Address : ROOM S032, 2/F, THE CAPITAL, 61-65 CHATHAM ROAD SOUTH, TSIM SHA TSUI, KOWLOON, HONG KONG Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: HTT202607400F02 Page 3 of 8 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 3 of 8 Contents 1 T E S T S T A N D A R D S ................................................... 4 2 S U M M A R Y .............................................................. 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Special Accessories 5 2.4 Modifications 5 3 T E S T E N V I R O N M E N T 6 3.1 Address of the test laboratory 6 3.2 Test Facility 6 3.3 Statement of the measurement uncertainty 6 4 T E S T L I M I T 7 4.1 Requirement 7 4.2 Conducted Power Results 8 4.3 Manufacturing tolerance 8 4.4 Evaluation Result 错误!未定义书签。 4.5 Simultaneous Transmission for SAR Exclusion 8 5 C O N C L U S I O N 8 Report No.: HTT202607400F02 Page 4 of 8 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 4 of 8 1 T E S T S T A N D A R D S The tests were performed according to following standards: ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Device, RF Exposure, Equipment Authorization Procedures. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices Report No.: HTT202607400F02 Page 5 of 8 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Page 5 of 8 2 S U M M A R Y 2.1 General Remarks Date of receipt of test sample : Jul. 09, 2026 Testing commenced on : Jul. 09, 2026 Testing concluded on : Jul. 16, 2026 2.2 Product Description Product Description: Panel Switch Model/Type reference: P1-12S Power supply: DC 12-24V Testing sample ID: HTT202607400-1# (Engineer sample) HTT202607400-2# (Normal sample) Hardware version: / Software version: / Bluetooth BLE Supported type: Bluetooth low Energy Modulation: GFSK Operation frequency: 2402MHz to 2480MHz Channel number: 40 Channel separation: 2 MHz Bit Rate of Transmitter: 1Mbps/2Mbps Antenna type: Wire Antenna Antenna gain: 1.50 dBi 2.3 Special Accessories The following is the EUT test of the auxiliary equipment provided by the laboratory: Description Manufacturer Model…
Text truncated - open the document above for the full version.
1. Antenna Description: Antenna type Wire antenna Model 2.4G ANT Frequency range 2400-2500MHz Manufacturer Hong Kong Xin Sheng Century Trading Co.,Limited Address ROOM S032, 2/F, THE CAPITAL, 61-65 CHATHAM ROAD SOUTH, TSIM SHA TSUI, KOWLOON, HONG KONG ANT Peak Gain 1.50 dBi 2. Antenna Photo: 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz
1 Appendix RF Test Data for BLE Company: : Hong Kong Xin Sheng Century Trading Co.,Limited EUT : Panel Switch FCC ID: : 2BW7Z-P1-12S Model Number : P1-12S Report No. : HTT202607400F01 Reviewed By : Heber He 2 1. Duty Cycle 1.1 Test Result 1.1.1 Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) Duty Cycle (%) Duty Cycle Correction Factor (dB) Max. DC Variation (%) 1M SISO 2402 0.443 0.625 70.88 1.49 0.00 2440 0.443 0.625 70.88 1.49 0.01 2480 0.443 0.625 70.88 1.49 0.03 2M SISO 2402 0.252 0.625 40.32 3.94 0.06 2440 0.259 0.625 41.44 3.83 0.03 2480 0.259 0.625 41.44 3.83 0.00 3 1.2 Test Graph 1.2.1 Ant1 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV 4 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV 5 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV 6 2. Bandwidth 2.1 Test Result 2.1.1 OBW Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 0.995 / Pass 2440 1 0.994 / Pass 2480 1 0.992 / Pass 2M SISO 2402 1 1.964 / Pass 2440 1 1.964 / Pass 2480 1 1.971 / Pass 2.1.2 6dB BW Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 0.696 >=0.5 Pass 2440 1 0.705 >=0.5 Pass 2480 1 0.709 >=0.5 Pass 2M SISO 2402 1 1.202 >=0.5 Pass 2440 1 1.222 >=0.5 Pass 2480 1 1.201 >=0.5 Pass 7 2.2 Test Graph 2.2.1 OBW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV 8 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV 9 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV 10 2.2.2 6dB BW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV 11 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV 12 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV 13 3. Maximum Conducted Output Power 3.1 Test Result 3.1.1 Power Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 1M SISO 2402 -2.36 <=30 Pass 2440 -2.34 <=30 Pass 2480 -2.51 <=30 Pass 2M SISO 2402 -2.36 <=30 Pass 2440 -2.33 <=30 Pass 2480 -2.50 <=30 Pass 14 4. Maximum Power Spectral Density 4.1 Test Result 4.1.1 PSD Mode TX Type Frequency (MHz) Maximum PSD (dBm) Verdict ANT1 Limit(dBm/3kHz) 1M SISO 2402 -2.36dBm/100kHz <=8 Pass 2440 -2.34dBm/100kHz <=8 Pass 2480 -2.51dBm/100kHz <=8 Pass 2M SISO 2402 -2.36dBm/100kHz <=8 Pass 2440 -2.32dBm/100kHz <=8 Pass 2480 -2.48dBm/100kHz <=8 Pass 15 4.2 Test Graph 4.2.1 PSD 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV 16 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV 17 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV 18 5. Unwanted Emissions In Non-restricted Frequency Bands 5.1 Test Result 5.1.1 Ref Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) 1M SISO 2402 1 -2.36 2440 1 -2.33 2480 1 -2.51 2M SISO 2402 1 -2.32 2440 1 -2.31 2480 1 -2.46 5.1.2 CSE Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) Limit (dBm) Verdict 1M SISO 2402 1 -2.36 -22.36 Pass 2440 1 -2.33 -22.33 Pass 2480 1 -2.51 -22.51 Pass 2M SISO 2402 1 -2.32 -22.32 Pass 2440 1 -2.31 -22.31 Pass 2480 1 -2.46 -22.46 Pass 19 5.2 Test Graph 5.2.1 Ref 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV 20 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV 21 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV 22 5.2.2 CSE 1M_LCH_2402MHz_Ant1_NTNV 1M_LCH_2402MHz_Ant1_NTNV 23 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV 24 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV 25 2M_LCH_2402MHz_Ant1_NTNV 2M_MCH_2440MHz_Ant1_NTNV 26 2M_HCH_2480MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV
Shenzhen HTT Technology Co., Ltd. Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : HTT202607400F01 2BW7Z-P1-12S Compiled by ( position+printed name+signature) : File administrators Heber He Supervised by ( position+printed name+signature) : Project Engineer Bruce Zhu Approved by ( position+printed name+signature) : RF Manager Kevin Yang Date of issue ...................................: Jul. 16, 2026 Testing Laboratory Name .............: Shenzhen HTT Technology Co.,Ltd. Address ..........................................: 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao’an District, Shenzhen, Guangdong, China Applicant’s name...........................: Hong Kong Xin Sheng Century Trading Co.,Limited Address ...........................................: ROOM S032, 2/F, THE CAPITAL, 61-65 CHATHAM ROAD SOUTH, TSIM SHA TSUI, KOWLOON, HONG KONG Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen HTT Technology Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HTT Technology Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HTT Technology Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : Panel Switch Trade Mark ......................................: N/A Manufacturer ...................................: Hong Kong Xin Sheng Century Trading Co.,Limited Model/Type reference .....................: P1-12S Listed Models ..................................: P1-08S Modulation ......................................: GFSK Frequency ........................................ From 2402MHz to 2480MHz Ratings ............................................: DC 12-24V Result ..............................................: PASS Report No.: HTT202607400F01 Page 2 of 34 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China T E S T R E P O R T Equipment under Test : Panel Switch Model /Type : P1-12S Listed Models : P1-08S Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number is different for these model. Applicant : Hong Kong Xin Sheng Century Trading Co.,Limited Address : ROOM S032, 2/F, THE CAPITAL, 61-65 CHATHAM ROAD SOUTH, TSIM SHA TSUI, KOWLOON, HONG KONG Manufacturer : Hong Kong Xin Sheng Century Trading Co.,Limited Address : ROOM S032, 2/F, THE CAPITAL, 61-65 CHATHAM ROAD SOUTH, TSIM SHA TSUI, KOWLOON, HONG KONG Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: HTT202607400F01 Page 3 of 34 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Contents 1 TEST STANDARDS .......................................................................................................................................... 4 2 SUMMARY ........................................................................................................................................................ 5 2.1 General Remarks .................................................................................................................................... 5 2.2 Product Description ................................................................................................................................. 5 2.3 Equipment Under Test ............................................................................................................................ 5 2.4 Short description of the Equipment under Test (EUT) ............................................................................ 5 2.5 EUT configuration .................................................................................................................................... 5 2.6 EUT operation mode ............................................................................................................................... 5 2.7 Block Diagram of Test Setup .................................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) .............................................................................................................. 6 2.9 Modifications ........................................................................................................................................... 6 3 TEST ENVIRONMENT ...................................................................................................................................... 7 3.1 Address of the test laboratory ................................................................................................................. 7 3.2 Test Facility ............................................................................................................................................. 7 3.3 Environmental conditions ........................................................................................................................ 7…
Text truncated - open the document above for the full version.
Shenzhen HTT Technology Co., Ltd. Report No.: HTT202607400 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 1 of 2 Product Name: Panel Switch Model No.: P1-12S Test Setup Photo Radiated Emission Report No.: HTT202607400 Shenzhen HTT Technology Co.,Ltd. Tel: 0755-23595200 Fax: 0755-23595201 1F, Building B, Huafeng International Robotics Industrial Park,Hangcheng Road, Nanchang Community, Xixiang Street, Bao'an District, Guangdong Province, Shenzhen, China Page 2 of 2 Conducted Emission RF Test ------End------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |