Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SensaSomethingInc. Address : 251LittleFallsDrive,Wilmington,19808,CountyofNewCastle,DelawareUnited States Date:2026-06-03 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BWA3-N-SENSAS1 FRN:0038468146. (“SensaSomethingInc.”)certifiesthat,asofthedateofthefilingoftheapplication,Sensa SomethingInc.isourdesignatedU.S.agentforserviceofprocessfortheabovereferenced FCCID.(“SensaSomethingInc.”)acceptstomaintainanagentfornolessthanoneyear afterthegranteehasterminatedallmarketingandimportationortheconclusionofany Commission-relatedproceedinginvolvingtheequipment. SensaSomethingInc.accepts,asofthedateofthefilingoftheapplication,theobligationof thedesignatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:SensaSomethingInc. Address:251LittleFallsDrive,Wilmington,19808,CountyofNewCastle,DelawareUnited States FRN:0038468146 ContactPerson:KimiOu Tel.:(165)315-6698 Email:[email protected] Sincerely, SignedonbehalfofSensaSomethingInc.SignedonbehalfofSensaSomethingInc. Name:KimiOuName:KimiOu Title:QualityManagerTitle:QualityManager Date:2026-06-03Date:2026-06-03
Rev1/26/2023 SensaSomethingInc. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:06-03-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BWA3-N-SENSAS1 (“SensaSomethingInc.”)certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules. (“SensaSomethingInc.”)certifiesthattheequipmentforwhichauthorizationissoughtdoesnotinclude cybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessors andassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofitssuccessorsand assignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446D01Covered EquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature)KimiOu (Applicantprintedname) Rev1/26/2023 SensaSomethingInc. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:06-03-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BWA3-N-SENSAS1 (“SensaSomethingInc.”)certifiesthat,asofthedateofthefilingoftheapplication,SensaSomething Inc.isnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesor affiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature) (Applicantprintedname)KimiOu
SensaSomethingInc. Date : 06-03-2026 Product/ModelNumber:PersonalMassager-Nippleclamp/SensaS1 FCCID : 2BWA3-N-SENSAS1 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By:KimiOu ContactListedonFCCWesbite Title:QualityManager Email:[email protected] Telephone:8618520822005 Onbehalfof:SensaSomethingInc.
SensaSomethingInc. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:June3,2026 Subject;RequestforConfidentiality FCCID:2BWA3-N-SENSAS1 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:KimiOu Title:QualityManager
Label: PersonalMassager-Nippleclamp Model:SensaS1FCCID:2BWA3-N-SENSAS1 Thisdevicecomplieswithpart15oftheFCCRules. Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesiredoperation. 25mm 23mm
FCCID:2BWA3-N-SENSAS1 RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093, UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances≤50mm,the1-gand10-gSARtest exclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f (GHz) ]≤3.0for1-gSAR,and≤7.5for10-gextremitySAR,where f (GHz) istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison Here, SoaSARtestisnotrequire ModeFrequ ency (MHz) Max Power (dBm) Target power W/ tolerance (dBm) Maxtune uppower tolerance (dBm) Max Power (mW) Min. Distanc e (mm) Calc. threshol ds limit GFSK 2402 0.42 0.5±1 1.51.41255.000.43783.0 2440 -0.01 0±1 11.25895.000.39333.0 2480 -0.77 -0.5±1 0.51.12205.000.35343.0
ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page1of23 RFTestData DutyCycle.....................................................................................................................................................................2 MaximumPeakConductedOutputPower....................................................................................................................5 -6dBBandwidth.............................................................................................................................................................8 OccupiedChannelBandwidth.....................................................................................................................................11 MaximumPowerSpectralDensityLevel.....................................................................................................................14 BandEdge..................................................................................................................................................................17 ConductedRFSpuriousEmission..............................................................................................................................20 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page2of23 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant115.278.1610.47 NVNTBLE1M2440Ant115.28.1810.53 NVNTBLE1M2480Ant114.248.4611.24 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page3of23 DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page4of23 DutyCycleNVNTBLE1M2480MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page5of23 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConducted Power(dBm) Conducted Power(W) Limit Conducted(dBm) Verdict NVNTBLE 1M 2402Ant10.420.001130Pass NVNTBLE 1M 2440Ant1-0.010.00130Pass NVNTBLE 1M 2480Ant1-0.770.0008430Pass ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page6of23 PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page7of23 PeakPowerNVNTBLE1M2480MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page8of23 -6dBBandwidth ConditionModeFrequency (MHz) Antenna-6dBBandwidth (MHz) Limit-6dBBandwidth (MHz) Verdict NVNTBLE 1M 2402Ant10.50890.5Pass NVNTBLE 1M 2440Ant10.51530.5Pass NVNTBLE 1M 2480Ant10.52210.5Pass ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page9of23 -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page10of23 -6dBBandwidthNVNTBLE1M2480MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page11of23 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.2049 NVNTBLE1M2440Ant11.2454 NVNTBLE1M2480Ant11.2479 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page12of23 OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page13of23 OBWNVNTBLE1M2480MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page14of23 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE 1M 2402Ant1-19.628Pass NVNTBLE 1M 2440Ant1-20.158Pass NVNTBLE 1M 2480Ant1-21.218Pass ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page15of23 PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page16of23 PSDNVNTBLE1M2480MHzAnt1 ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page17of23 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-50.7-20Pass NVNTBLE1M2480Ant1-54.39-20Pass ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page18of23 BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page19of23 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page20of23 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-46.96-20Pass NVNTBLE1M2440Ant1-43.6-20Pass NVNTBLE1M2480Ant1-40.81-20Pass ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page21of23 Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page22of23 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:SZNTT26020686E1-1 SZNTT-TR728-0Page23of23 Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission
承认书项目表 Acknowledgment Form List 页码 NO. 页数 ( Number 内 容 ( Contents ) ofPage ) Code ) ( Page 1 承认书封面 (Spec Cover) 11 2 承认书项目表(Spec Item) 12 3 工程成品图 ( Drawing ) 13 4 电性测试报告(Test Reports) 14 5 S 参数测试( S Parameter ) 15 6 增益测试 (Gain Test) 16 7 8 9 10 --- 11--- 12--- 描述 料号 图号 版本 外来图纸受控章 V 0 1 天线I-PEX 1422DV01P1C0050025B Sensa Something Inc. Address:251 Little Falls Drive, Wilmington, 19808, County of New Castle, Delaware United States 电性测试报告 T estReports ElectricalProperties Frequency2.4~2.5GHz ;4.9~5.9GHz Impedance50 0hm Nominal V.S.W.R1.92 : 1 Max Return Loss-10 dB Max RadiationOmni-directional Gain (Peak)5dBi Cable Loss3.2 dB / m Max @ 2450 MHz PolarizationLinear, Vertical Admitted Power1 W Connectoripex PhysicalProperties Antenna MaterialFPCB Operating Temp.-10 ~ +60 ̊ Cable TypeO.D. 1.13mm // 8 0 mm C Storage Temp. -10 ~ +70 ̊C Cable ColorBlack 描述 料号 图号 版本 外来图纸受控章 V 0 1 天线I-PEX 1422DV01P1C0050025B SIGN DATE DESCRIPTION APPROVER R-CB-081B NB030B CI-081 No. FPCB Coaxial Cable Connector Name 42*12mm O.D. 1.13 mm Black Mini Connector Part Numb er Material Q ty TITLE: 2.4GHz Antenna PART NO.: WF4212-IPEX 1- 8 cm APPROVED BY DWG NAME: NB030- 113 B-IX 8 0.DW G DESIDNED BY UNITS: mm Tolerance CHECKED BY SCALE: 1/1 REVISION: A jeff 2014-02-26 2014-02-26 leon 2014-02-26 YD X.X ±0.20X.XX ±0.10X° ±3° 80 .0±3.0 描述 料号 图号 版本 外来图纸受控章 V 0 1 天线I-PEX 1422DV01P1C0050025B S 参数测试 SParameterTest AgilentE5071C 描述 料号 图号 版本 外来图纸受控章 V 0 1 天线I-PEX 1422DV01P1C0050025B 增益测试 GainTest Antenna Radiation Pattern VS Gain 描述 料号 图号 版本 外来图纸受控章 V 0 1 天线I-PEX 1422DV01P1C0050025B
ShenzhenNTTTestingTechnologyCo.,Ltd.ReportNo.:SZNTT26020686E1-1 SZNTT-TR828-0Tel:0755-27889935Web:http://www.ntt-testing.comPage1of29 TESTREPORT Applicant:SensaSomethingInc. Address: 251LittleFallsDrive,Wilmington,19808,CountyofNewCastle, DelawareUnitedStates Manufacturer:iMotion(ShangHai)ProductDesignCompanyLimited. Address: Building4-B,No.315,JianYeRoad,PudongDistrict,201201 ShangHai,P.R.China ProductName:PersonalMassager-Nippleclamp ModelNumber:SensaS1 Trademark:Sensa FCCID:2BWA3-N-SENSAS1 TestDate: Apr.29,2026–May26,2026 DateofReport: May26,2026 TestResult: ThisdevicedescribedabovehasbeentestedbyNTT,andthetest resultsshowthattheequipmentundertest(EUT)isincompliance withtheStandardrequirements.Anditisapplicableonlytothetested sampleidentifiedinthereport. TestProcedureUsed: Standards:FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10-2020+Cor.1-2023 KDB558074D0115.247MeasGuidancev05r02 Preparedby(TestEngineer): ZhaoDi Approved(Manager): KenWu Approved(Manager): AbelYu ShenzhenNTTTestingTechnologyCo.,Ltd.ReportNo.:SZNTT26020686E1-1 SZNTT-TR828-0Tel:0755-27889935Web:http://www.ntt-testing.comPage2of29 TABLEOFCONTENT 1.GeneralInformation......................................................................................4 1.1.DescriptionofDevice(EUT).......................................................................................................................4 1.2.ChannelList..................................................................................................................................................4 1.3.Summaryoftestresult................................................................................................................................5 1.4.SpecialAccessoriesandAuxiliaryEquipment........................................................................................5 1.5.Testmode......................................................................................................................................................5 1.6.Testconfiguration.........................................................................................................................................5 1.7.BlockDiagram...............................................................................................................................................6 1.8.TestConditions.............................................................................................................................................6 1.9.MeasurementUncertainty(95%confidencelevels,k=2)......................................................................6 1.10.TestFacility..................................................................................................................................................7 1.11.TestEquipment...........................................................................................................................................8 2.Conductedemissionatthemainsterminalstest....................................10 2.1.Limit..............................................................................................................................................................10 2.2.TestSetup....................................................................................................................................................10 2.3.TestProcedure............................................................................................................................................10 2.4.TestResult...................................................................................................................................................10 3.RadiatedSpuriousEmissions...................................................................13 3.1.Limit..............................................................................................................................................................13 3.2.TestSetup....................................................................................................................................................14 3.3.TestProcedure............................................................................................................................................16 3.4.TestResult...................................................................................................................................................17 4.ConductedSpuriousEmissions................................................................22 4.1.Limit..............................................................................................................................................................22 4.2.TestSetup....................................................................................................................................................22 4.3.TestProcedure............................................................................................................................................22 4.4.TestResult...................................................................................................................................................23 5.BandEdgeMeasurement...........................................................................24 5.1.Limit..............................................................................................................................................................24 5.2.Testsetup....................................................................................................................................................24 5.3.TestProcedure............................................................................................................................................24 5.4.TestResult...................................................................................................................................................24 6.-6dBBandwidthand99%BandwidthMeasurement.....................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |
Personal Massager-Main Unit
Equipment Class
DTS - Digital Transmission System