FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Yihai New Energy Technology Co., Ltd./
  3. 2BWC4-CY1MX05A

2BWC4-CY1MX05ACHONGYUE FirstSight Power Bank 5000mAh

Shenzhen Yihai New Energy Technology Co., Ltd.
CHONGYUE FirstSight Power Bank 5000mAh - FCC ID 2BWC4-CY1MX05A - Shenzhen Yihai New Energy Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 09, 2026
Application Purpose
Original Equipment
Equipment Note
CHONGYUE FirstSight Power Bank 5000mAh
Frequency Range
0.11000000 - 0.20500000
Company
Shenzhen Yihai New Energy Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CY2MU10A ChongYue WindRise Power Bank 10000mAh Read this manual before use and keep it for reference. PACKAGE CONTENTS & PRODUCT STRUCTURE 02 01 Wireless charging area 02 Power button 03 Wireless indicator 04 Battery level indicator 05 USB-C port PACKAGE CONTENTS ChongYue Magnetic Power Bankx 1 USB-C to USB-C Fast Charging Cable (15 cm)x 1 User Manualx 1 Use only chargers that meet applicable safety and regulatory certification standards. TECHNICAL SPECIFICATIONS 03 IDENTITY PRODUCTChongYue WindRise Power Bank 10000mAh PRODUCT MODELCY2MU10A BATTERY CELL CAPACITY5000mAh CELL CONFIGURATION Dual-cell parallel/series technology RATED ENERGY38.5Wh RATED CAPACITY 5700mAhundertypical5Vconditions BATTERY TYPELithium-ion Polymer Battery INPUT & OUTPUT USB-C INPUT 5V/3A, 9V/3A (Max 27W) USB-C OUTPUT 5V/3A, 9V/3A, 10V/2.25A, 12V/2.5A, 15V/2A, 20V/1.5A (Max 30W) WIRELESS OUTPUT5W / 7.5W / 10W / 15W Max MULTI-PORT OUTPUT5V=3A, 15W total shared output PHYSICAL DIMENSIONS104mm x 69mm x 14.5mm OPERATING TEMP.-10°C ~ 55°C STORAGE TEMP.-20°C ~ 60°C INDICATOR STATUS DESCRIPTION 04 BATTERY LEVEL INDICATORS FlashingRemaining power <= 25% Charging Remaining power 26% to 50% Charging Remaining power 51% to 75% Charging Remaining power 76% to 99% SolidBattery fully charged WIRELESS CHARGING INDICATOR Solid ice bluefast wireless charging is normal. Flashing redmetal foreign object or high temperature protection. All 4 LEDs flashing together abnormal system protection. WARNING If the red indicator flashes, remove metal objects from the charging area and allow the device to cool before use. FAST OPERATION GUIDE 05 01 WAKE Press the power button once to check battery level and activate wireless charging. 02 ALIGN Place the phone against the magnetic side and align it precisely with the center ring. 03 COMPATIBILITY Magnetic attachment is designed primarily for MagSafe- compatible iPhone models or magnetic phone cases. 04 CASES Non-magnetic phones may need a magnetic alignment ring or compatible case; cases over 4mm, metal, or carbon fiber may reduce efficiency. 05 STOP Output shuts down after 32 seconds of inactivity or below 100mA. Double-press to turn off manually. For best efficiency, keep the phone centered on the magnetic charging area during wireless charging. SAFETY WARNINGS & CAUTIONS 06 TRAVEL & TEMPERATURE 01Carry-on only: Rated energy is 38.5Wh, below the common 100Wh carry-on limit. Carry in cabin baggage according to airline and airport rules; do not place in checked baggage. 02Temperature range: Recommended operating temperature is -10°C ~ 55°C. Recommended storage temperature is -20°C ~ 60°C. USE ENVIRONMENT 03Child safety: Keep away from children. This device is not a toy. 04 Ventilation: Do not charge or discharge in pockets, cramped bags, beds, sofa cushions, or thick rugs. 05Avoid heat: Do not expose to fire, direct vehicle heat, or temperatures above 60°C / 140°F. DAMAGE & DISPOSAL 06No impact: Do not disassemble, crush, puncture, drop, or place heavy objects on the device. 07 Stop use: Stop use if swelling, deformation, leakage, cracks, liquid ingress, or severe capacity loss occurs. 08Recycle properly: Do not discard with household waste. Recycle through an authorized electronic waste collection point. GLOBAL WARRANTY & CLAIM INFORMATION 07 Repair or replacement is available for manufacturing or quality defects with valid proof of purchase. COMPLIANCE & QUALITY CE REDCE ROHS 2.0FCC ID UL 2056 third-party tested QC PASSEDApproved for Export WARRANTY SERVICE 12-month limited warranty for manufacturing or quality defects with valid proof of purchase. Keep a receipt, invoice, or online order screenshot from an authorized store. WARRANTY EXCLUSIONS Warranty excludes use beyond the 12-month period, misuse, improper storage, or frequent electrical overload contrary to this manual. Warranty excludes severe drops, heavy impact, external compression, structural bending, casing cracks, or casing deformation. Warranty excludes water exposure, extreme humidity, liquid ingress, oxidation damage, mismatched or poor-quality non-certified chargers, and unauthorized disassembly, modification, or repair. MANUFACTURER INFORMATION MANUFACTURER Shenzhen Yihai New Energy Technology Co., Ltd. WEBSITE https://chongyuepower.co ADDRESS C1807, Block BC, Huizhi R&D Center Longteng Community, Xixiang Subdistrict, Shenzhen,China m Specifications are subject to the final product label and packaging. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Radiation Exposure Statement This device complies with FCC RF…

Text truncated - open the document above for the full version.

External Photos

FCC:2BWC4-CY1MX05A ExternalPhotosoftheEUT Fig.1 Fig.2 FCC:2BWC4-CY1MX05A Fig.3 Fig.4 FCC:2BWC4-CY1MX05A Fig.5 Fig.6 FCC:2BWC4-CY1MX05A Fig.7

ID Label/Location Info

FCC:2BWC4-CY1MX05A labelandlocation Size(30*60mm) Fig.1 FCCID:2BWC4-CY1MX05A CHONGYUEFirstSightPowerBank5000mAh Model:CY1MX05A USB-CInput:5V⎓3A,9V⎓2.22A(Max20W) USB-COutput:5V⎓3A,9V⎓2.5A(Max22.5W) WirelessOutput:5W/7.5W/10W/15W(Max) TotalOutput:5V⎓3A(Max) Battery:3.85V5000mAh19.25Wh ShenzhenYihaiNewEnergyTechnologyCo.,Ltd.

Internal Photos

FCCID:2BWC4-CY1MX05A InternalPhotosoftheEUT Fig.1 Fig.2 LoopcoilAntenna FCCID:2BWC4-CY1MX05A Fig.3 Fig.4 FCCID:2BWC4-CY1MX05A Fig.5 Fig.6

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC RF Exposure Report Reference No. ..................... : FCC ID............................................ : CTA26080302702 2BWC4-CY1MX05A Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Aug. 20, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Yihai New Energy Technology Co., Ltd. Address ............................................ : C1807, Block BC, Huizhi R&D Center Longteng Community, Xixiang Subdistrict, Shenzhen,China Test specification ........................... : FCC CFR 47 PART 1, § 1.1310 Standard ........................................... : KDB 680106 D01 Wireless Power Transfer v04 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : CHONGYUE FirstSight Power Bank 5000mAh Trade Mark ....................................... : CHONGYUE Manufacturer .................................... : Shenzhen Yihai New Energy Technology Co., Ltd. Model/Type reference ...................... : CY1MX05A Listed Models ................................. : N/A Modulation Type ............................... : ASK Operation Frequency ........................ : From 110KHz~205KHz Rating ............................................... : USB-C Input: 5V⎓3A, 9V⎓2.22A(Max 20W) USB-C Output: 5V⎓3A, 9V⎓2.5A(Max 22.5W) Wireless Output: 5W / 7.5W / 10W / 15W(Max) Total Output: 5V⎓3A(Max) Battery: 3.85V 5000mAh 19.25Wh Result ............................................... : PASS Report No.: CTA26080302702 Page 2 of 14 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : CHONGYUE FirstSight Power Bank 5000mAh Model /Type : CY1MX05A Listed Models : N/A Applicant : Shenzhen Yihai New Energy Technology Co., Ltd. Address : C1807, Block BC, Huizhi R&D Center Longteng Community, Xixiang Subdistrict, Shenzhen,China Manufacturer : Shenzhen Yihai New Energy Technology Co., Ltd. Address : C1807, Block BC, Huizhi R&D Center Longteng Community, Xixiang Subdistrict, Shenzhen,China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26080302702 Page 3 of 14 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................... 4 2 S U M M A R Y .............................................................. 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Description of the test mode 5 2.4 Special Accessories 6 2.5 Modifications 6 3 T E S T E N V I R O N M E N T 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Statement of the measurement uncertainty 7 3.4 Equipments Used during the Test 8 4 T E S T L I M I T 8 4.1 Requirement 8 4.2 Test setup 10 4.3 Test Procedures 11 4.4 Equipment Approval Considerations of KDB 680106 D01v04 11 4.5 Test results 12 4.6 Conclusion 13 5 P H O T O G R A P H S O F T H E T E S T S E T U P......................... 14 Report No.: CTA26080302702 Page 4 of 14 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: 680106 D01 Wireless Power Transfer v04: EQUIPMENT AUTHORIZATION OF WIRELESS POWER TRANSFER DEVICES. Report No.: CTA26080302702 Page 5 of 14 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 2 S U M M A R Y 2.1 General Remarks Date of receipt of test sample : Aug. 03, 2026 Testing commenced on : Aug. 03, 2026 Testing concluded on : Aug. 20, 2026 2.2 Product Description Product Name: CHONGYUE FirstSight Power Bank 5000mAh Model/Type reference: CY1MX05A Hardware version: V1.0 Software version: V1.0 Test samples ID: CTA260803027-1# (Engineer sample) CTA260803027-2# (Normal sample) Power supply: USB-C Input: 5V⎓3A, 9V⎓2.22A(Max 20W) USB-C Output: 5V⎓3A, 9V⎓2.5A(Max 22.5W) Wireless Output: 5W / 7.5W / 10W / 15W(Max) Total Output: 5V⎓3A(Max) Battery: 3.85V 5000mAh 19.25Wh Operation frequency: 110KHz - 205KHz…

Text truncated - open the document above for the full version.

Test Report

Antennaspec FC C ID: 2BWC4-CY1MX05A 1. AntennaDescription: AntennatypeLoop coil antenna Model A-0080-024 Frequencyrange110KHz~205KHz ManufacturerShenzhenChenxingElectronicTechnologyCo., Ltd. Address5th Floor, Building1, XinkelicTechnologyIndustrialPark, No. 51 DabaoRoadXin'anStreet,Bao'anDistrict, ShenzhenCity, GuangdongProvince,China 2. AntennaPhoto : Outsidediameter:39.85mm Innerdiameter:10.44mm Numberof turns:10 Wirediameter:0.08 mm We, Shenzhen Yihai New Energy Technology Co., Ltd., states that All measurements were performed radiated and therefore additional antenna gain documentation is not required.

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT Report Reference No. ..................... : FCC ID............................................ : CTA26080302701 2BWC4-CY1MX05A Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Aug. 20, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Yihai New Energy Technology Co., Ltd. Address............................................ : C1807, Block BC, Huizhi R&D Center Longteng Community, Xixiang Subdistrict, Shenzhen,China Test specification ........................... : Standard ........................................... : FCC Rules and Regulations Part 15 Subpart C (Section 15.209), ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a- 2024 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : CHONGYUE FirstSight Power Bank 5000mAh Trade Mark ....................................... : CHONGYUE Manufacturer .................................... : Shenzhen Yihai New Energy Technology Co., Ltd. Model/Type reference ...................... : CY1MX05A Listed Models ................................. : N/A Modulation Type ............................... : ASK Operation Frequency ........................ : From 110KHz~205KHz Ratings ............................................. : USB-C Input: 5V⎓3A, 9V⎓2.22A(Max 20W) USB-C Output: 5V⎓3A, 9V⎓2.5A(Max 22.5W) Wireless Output: 5W / 7.5W / 10W / 15W(Max) Total Output: 5V⎓3A(Max) Battery: 3.85V 5000mAh 19.25Wh Result ............................................... : PASS Report No.: CTA26080302701 Page 2 of 25 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : CHONGYUE FirstSight Power Bank 5000mAh Model /Type : CY1MX05A Listed Models : N/A Applicant : Shenzhen Yihai New Energy Technology Co., Ltd. Address : C1807, Block BC, Huizhi R&D Center Longteng Community, Xixiang Subdistrict, Shenzhen,China Manufacturer : Shenzhen Yihai New Energy Technology Co., Ltd. Address : C1807, Block BC, Huizhi R&D Center Longteng Community, Xixiang Subdistrict, Shenzhen,China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26080302701 Page 3 of 25 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Description of the test mode 5 2.4 Special Accessories 6 2.5 Modifications 6 3 T E S T E N V I R O N M E N T .............................................................. 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Summary of measurement results 8 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 11 4.1 AC Power Conducted Emission 11 4.2 Radiated Emission 14 4.3 The 20dB bandwidth 18 4.4 Antenna Requirement 19 5 T E S T S E T U P P H O T O S O F T H E E U T ......................................... 20 6 PH O T O S O F T H E E U T ........................................................... 21 Report No.: CTA26080302701 Page 4 of 25 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15 Subpart C (Section 15.207): Conducted limits. FCC Rules and Regulations Part 15 Subpart C (Section 15.209): Radiated emission limits; general requirements. ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024: American National Standard for Testing Unlicensed Wireless Devices Report No.: CTA26080302701 Page 5 of 25 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 2 S U M M A R Y 2.1 General Re…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC:2BWC4-CY1MX05A TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 FCC:2BWC4-CY1MX05A TestSetupPhotoofLineConductedEmissionsMeasurement Fig.3 TestSetupPhoto(s)ofEMFMeasurement Fig.4

Contact Information

Applicant

Lai Ting(Legal Representative)
[email protected]Fax: +86 18565898976

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place, Fullerton, · United States

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Shenzhen Yihai New Energy Technology Co., Ltd.

ChongYue WindRise Power Bank 10000mAh - FCC ID 2BWC4-CY2MU10A - Shenzhen Yihai New Energy Technology Co., Ltd.
2BWC4-CY2MU10A

ChongYue WindRise Power Bank 10000mAh

Jul 20, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz