FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Hongsheng Ruida Technology Co., Ltd/
  3. 2BWJL-HS02

2BWJL-HS02Bluetooth bathroom speaker bracket

Shenzhen Hongsheng Ruida Technology Co., Ltd

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 14, 2026
Application Purpose
Original Equipment
Equipment Note
Bluetooth bathroom speaker bracket
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Hongsheng Ruida Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ShenzhenHongshengRuidaTechnologyCo., Ltd Address : Room402, No. 7, Longyuan4 Lane,LonggangCommunity,LonggangStreet,Longgang District,ShenzhenCity, China Date: 2026-06-12 FederalCommunicationsCommission Authorizationand EvaluationDivision 7435 OaklandMills Road Columbia,MD 21046 Ref: Attestation Statements Part 2.911(d)(7) Filing SUBJECT: FCC Application for FCC ID:2BWJL-HS02 FRN:0038525549 (“ShenzhenHongshengRuida TechnologyCo., Ltd ”) certifiesthat, as of the date of the filing of the application,CELLTINC. is our designatedU.S. agent for serviceof processfor the abovereferencedFCC ID. (“ShenzhenHongshengRuida TechnologyCo., Ltd ”) acceptsto maintainan agent for no less than one year after the granteehas terminatedall marketing and importationor the conclusionof an y Commission-relatedproceedinginvolvingthe equipment. CELLTINC. accepts,as of the date of the filing of the application,the obligationof the designatedU.S. agent for serviceof processfor the abovereferencedFCC ID. DesignatedU.S. AgentInformation: Name:CELLTINC. Address:1401 21ST ST# 12958SACRAMENTO,CA 95811UnitedStates FRN:0036412567 ContactPerson:ThompsonLim Tel.: (424) 347-4188 Email:[email protected] Sincerely, Signedon behalfof ShenzhenHongsheng Ruida TechnologyCo., Ltd Signedon behalfof CELLTINC. Name:Wang HongboName:ThompsonLim Title: MangerTitle: GeneralManager Date: 2026-06-12Date: 2026-06-12

Attestation Statements

Rev 1/26/2023 ShenzhenHongshengRuidaTechnologyCo., Ltd FederalCommunicationsCommission Authorizationand EvaluationDivision 7435OaklandMillsRoad Columbia,MD 21046 USA Date:06 -10 -2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BWJL-HS02 (“ShenzhenHongshengRuidaTechnologyCo., Ltd ”) certifiesthat the equipmentfor whichauthorization is soughtis not“covered” equipmentprohibitedfromreceivingan equipmentauthorizationpursuantto section2.903of the FCC rules. (“ShenzhenHongshengRuidaTechnologyCo., Ltd ”) certifiesthat the equipmentfor whichauthorization is soughtdoesnot includecybersecurityor anti-virussoftwareproducedor providedby KasperskyLab, Inc. or any of its successorsand assignees,includingequipmentwith integratedKasperskyLab, Inc. (or any of its successorsand assignees)cybersecurityor anti-virussoftwarepursuantto DA-24-886and KDB 986446D01 CoveredEquipmentGuidancesectionB(2a). Deviceis inherentlycompliantbasedon hardwarelimitationsor softwarecontrols. or A SoftwareBill of Materials(SBOM)is providedto the TCB for review,and The end-useror thirdpartiescannotinstalladditionalsoftwareon this device. Sincerely, (Applicantsignature)WangHongbo (Applicantprintedname) Rev1/26/2023 ShenzhenHongshengRuidaTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:06-10-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BWJL-HS02 (“ShenzhenHongshengRuidaTechnologyCo.,Ltd”)certifiesthat,asofthedateofthefilingofthe application,ShenzhenHongshengRuidaTechnologyCo.,LtdisnotidentifiedontheCoveredList(asa specificallynamedentityoranyofitssubsidiariesoraffiliates)asanentityproducing“covered” equipment. Sincerely, (Applicantsignature) (Applicantprintedname)WangHongbo

Cover Letter(s)

ShenzhenHongshengRuidaTechnologyCo., Ltd Date : 06-10 -2026 Product/ Model Number: Bluetooth bathroom speaker bracket/HS02 FCC ID: 2BWJL-HS02 To whomit may concern, Re:ProductCertificationRepresentativeAuthorizationLetter We authorizeQAI LaboratoriesLtd. 3980 North FraserWay, BurnabyB.C. CanadaV5J 5K5 to act on our behalfon all mattersconcerningthe above namedequipment. This shall includethe following: Testing Approvalapplicationsand procedures We declarethat QAI LaboratoriesLtd. is allowedto forwardall information relatedto the approvalprojectto the appliedcertificationbody and to the notificationentitiesand to discussany issuesconcerningthe approval application.Any and all acts carriedout by QAI LaboratoriesLtd. on our behalfshall have the same effect as acts of our own. By: WangHongbo ContactListedon FCC Wesbite Title: Manger Email : [email protected] Telephone:17665216133 On behalfof: ShenzhenHongshengRuidaTechnologyCo., Ltd

Cover Letter(s)

ShenzhenHongshengRuida TechnologyCo., Ltd Officeof EngineeringTechnology FederalCommunicationsCommission 7435 OaklandMills Road Columbia,MD 21046 USA Date: June 12, 2026 Subject; Request for Confidentiality FCC ID: 2BWJL-HS02 To WhomIt May Concern, Pursuantto the provisionsof the Commission’s rules Title 47 Sections§0.457 and §0.459,we are requestingthe Commissionto withholdthe followingattachment(s)as confidential documentsfrom publicdisclosureindefinitely. Thesedocumentscontaindetailedsystemand equipmentdescriptionsand are consideredas proprietaryinformationin operationof the equipment.The publicdisclosureof these documentsmight be harmfulto our companyand wouldgive competitorsan unfair advantage in the market. SchematicDiagram Block Diagram Parts List OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsfor UNII devices In additionalto abovementioneddocuments,in order to complywith the marketingregulations in Title 47 CFR §2.803 and the importationrules in Title 47 CFR §2.1204,while ensuringthat businesssensitiveinformationremainsconfidentialuntil the actualmarketingof newly authorizeddevices,we requestShort Term Confidentialityof the followingattachment(s); ExternalPhotos Test SetupPhotos InternalPhotos User Manual For 45 days, pursuantto PublicNoticeDA 04-1705. OR For 180 days pursuantto KDB 726920D01. It is our understandingthat all measurementtest reports,FCC ID label formatand correspondenceduringthe certificationreviewprocesscannotbe grantedas confidential documentsand this informationwill be availablefor publicreviewonce the grant of equipment authorizationis issued. Sincerely, Signature: Name:WangHongbo Title: Manger

ID Label/Location Info

Labe l: Model: HS02 FCC ID:2BWJL-HS02 Thisdevicecomplieswithpart15 of the FCCRules. Operationis subjectto thefollowingtwo conditions: (1)Thisdevicemay not causeharmfulinterference,and (2) thisdevicemustacceptanyinterferencereceived, includinginterferencethat may causeundesiredoperation. 34mm 28mm

RF Exposure Info

FCC ID:2BWJL-HS02 RF ExposureEvaluation AccordingtoKDB 447498D01 GeneralRF ExposureGuidancev06andpart2.1093, UnlessspecificallyrequiredbythepublishedRF exposureKDB procedures, standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,is notrequiredwhenthe correspondingSAR Test ExclusionThresholdcondition(s),listedbelow,is (are)satisfied. For100MHzto6 GHzandtestseparationdistances≤ 50mm,the1-gand10-gSARtest exclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/ (min.testseparationdistance, mm)]· [√f (GHz) ] ≤ 3.0for1-gSAR,and≤ 7.5for10-gextremitySAR,where f (GHz) is theRFchanneltransmitfrequencyin GHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultis roundedtoonedecimalplaceforcomparison Here, Soa SARtestis notrequire ModeFrequ ency (MHz) Max Power (dBm) Target power W/ tolerance (dBm) Maxtune uppower tolerance (dBm) Max Power (mW) Min. Distanc e (mm) Calc. threshol ds limit GFSK 2402 -2.44 -2.5±1 -1.50.70795.000.21943.0 2441 -3.23 -3.0±1 -20.63105.000.19723.0 2480 -4.31 -4.0±1 -30.50125.000.15793.0 Π /4-DQP SK 2402 -1.61 -1.5±1 -0.50.89135.000.27633.0 2441 -2.45 -2.5 ± 1 -1.50.70795.000.22123.0 2480 -3.48 -3.5 ± 1 -2.50.56235.000.17713.0 8DPSK 2402 -0.99 -1.0 ± 1 01.00005.000.31003.0 2441 -1.75 -2.0 ± 1 -10.79435.000.24823.0 2480 -2.85 -3.0 ± 1 -20.63105.000.19873.0

Test Report

Inverted F Antenna Specification Summary ITEMANT SPEC Model Name 2.4G ANT HorizontalVertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz Center Frequency -1.73 -0.84 -0.68 -6.15 -3.70 -2.32 MAX. Gain -0 .68dBi PolarizationHorizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance50 Ohm Kexing Road No. 333, Xiangzhou District, Zhuhai City, Guangdong Province, China Antenna Length 14.09mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) length:14.09mm width:6.14mm PCB Antenna Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dBi) Frequency (MHz) MaxMinAvg 2400-1.73178-30.0815-8.48713 2450-0.845801-38.5605-7.88012 2500-0.685586-24.0318-6.79139 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dBi) Frequency (MHz) MaxMinAvg 2400-6.1530-24.1420-13.0295 2450-3.7054-26.5836-10.6700 2500-2.32122-30.4301-9.70536 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

ReportNo.: SZNTT26020704E1-1 SZNTT-TR728-0Page 1of 68 RF Test Data FCC ID:2BWJL-HS02 Duty Cycle .....................................................................................................................................................................2 MaximumPeak ConductedOutputPower....................................................................................................................8 -20dBBandwidth.........................................................................................................................................................14 OccupiedChannelBandwidth.....................................................................................................................................20 CarrierFrequenciesSeparation..................................................................................................................................26 Band Edge ..................................................................................................................................................................32 Band Edge(Hopping)...................................................................................................................................................39 ConductedRF SpuriousEmission..............................................................................................................................46 Numberof HoppingChannel.......................................................................................................................................56 Dwell Time ..................................................................................................................................................................59 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page2of68 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNT1-DH12402Ant130.195.22.65 NVNT1-DH12441Ant130.165.212.65 NVNT1-DH12480Ant130.165.212.65 NVNT2-DH12402Ant130.965.092.58 NVNT2-DH12441Ant130.995.092.58 NVNT2-DH12480Ant130.995.092.58 NVNT3-DH12402Ant131.435.032.54 NVNT3-DH12441Ant131.45.032.55 NVNT3-DH12480Ant131.435.032.54 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page3of68 DutyCycleNVNT1-DH12402MHzAnt1 DutyCycleNVNT1-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page4of68 DutyCycleNVNT1-DH12480MHzAnt1 DutyCycleNVNT2-DH12402MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page5of68 DutyCycleNVNT2-DH12441MHzAnt1 DutyCycleNVNT2-DH12480MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page6of68 DutyCycleNVNT3-DH12402MHzAnt1 DutyCycleNVNT3-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page7of68 DutyCycleNVNT3-DH12480MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page8of68 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConducted Power(dBm) Conducted Power(W) Limit Conducted(dBm) Verdict NVNT1-DH12402Ant1-2.440.0005721Pass NVNT1-DH12441Ant1-3.230.0004821Pass NVNT1-DH12480Ant1-4.310.0003721Pass NVNT2-DH12402Ant1-1.610.0006921Pass NVNT2-DH12441Ant1-2.450.0005721Pass NVNT2-DH12480Ant1-3.480.0004521Pass NVNT3-DH12402Ant1-0.990.000821Pass NVNT3-DH12441Ant1-1.750.0006721Pass NVNT3-DH12480Ant1-2.850.0005221Pass ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page9of68 PeakPowerNVNT1-DH12402MHzAnt1 PeakPowerNVNT1-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page10of68 PeakPowerNVNT1-DH12480MHzAnt1 PeakPowerNVNT2-DH12402MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page11of68 PeakPowerNVNT2-DH12441MHzAnt1 PeakPowerNVNT2-DH12480MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page12of68 PeakPowerNVNT3-DH12402MHzAnt1 PeakPowerNVNT3-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page13of68 PeakPowerNVNT3-DH12480MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page14of68 -20dBBandwidth ConditionModeFrequency(MHz)Antenna-20dBBandwidth(MHz)Verdict NVNT1-DH12402Ant11.028Pass NVNT1-DH12441Ant11.033Pass NVNT1-DH12480Ant11.022Pass NVNT2-DH12402Ant11.276Pass NVNT2-DH12441Ant11.256Pass NVNT2-DH12480Ant11.305Pass NVNT3-DH12402Ant11.247Pass NVNT3-DH12441Ant11.259Pass NVNT3-DH12480Ant11.262Pass ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page15of68 -20dBBandwidthNVNT1-DH12402MHzAnt1 -20dBBandwidthNVNT1-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page16of68 -20dBBandwidthNVNT1-DH12480MHzAnt1 -20dBBandwidthNVNT2-DH12402MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page17of68 -20dBBandwidthNVNT2-DH12441MHzAnt1 -20dBBandwidthNVNT2-DH12480MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page18of68 -20dBBandwidthNVNT3-DH12402MHzAnt1 -20dBBandwidthNVNT3-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page19of68 -20dBBandwidthNVNT3-DH12480MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page20of68 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNT1-DH12402Ant10.93617 NVNT1-DH12441Ant10.97316 NVNT1-DH12480Ant10.98529 NVNT2-DH12402Ant11.2049 NVNT2-DH12441Ant11.1937 NVNT2-DH12480Ant11.1895 NVNT3-DH12402Ant11.1894 NVNT3-DH12441Ant11.1856 NVNT3-DH12480Ant11.1856 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page21of68 OBWNVNT1-DH12402MHzAnt1 OBWNVNT1-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page22of68 OBWNVNT1-DH12480MHzAnt1 OBWNVNT2-DH12402MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page23of68 OBWNVNT2-DH12441MHzAnt1 OBWNVNT2-DH12480MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page24of68 OBWNVNT3-DH12402MHzAnt1 OBWNVNT3-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page25of68 OBWNVNT3-DH12480MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page26of68 CarrierFrequenciesSeparation ConditionModeAntennaHoppingFreq1 (MHz) HoppingFreq2 (MHz) HFS (MHz) Limit (MHz) Verdict NVNT1-DH1Ant12402.00624030.9940.685Pass NVNT1-DH1Ant12440.98224421.0180.689Pass NVNT1-DH1Ant12479.0162479.9960.980.681Pass NVNT2-DH1Ant12401.992403.0181.0280.851Pass NVNT2-DH1Ant124412442.0021.0020.837Pass NVNT2-DH1Ant12478.9942479.9880.9940.870Pass NVNT3-DH1Ant12402.0022403.0081.0060.831Pass NVNT3-DH1Ant12441.0042442.00410.839Pass NVNT3-DH1Ant12…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page35of68 BandEdgeNVNT2-DH12402MHzAnt1No-HoppingRef BandEdgeNVNT2-DH12402MHzAnt1No-HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page36of68 BandEdgeNVNT2-DH12480MHzAnt1No-HoppingRef BandEdgeNVNT2-DH12480MHzAnt1No-HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page37of68 BandEdgeNVNT3-DH12402MHzAnt1No-HoppingRef BandEdgeNVNT3-DH12402MHzAnt1No-HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page38of68 BandEdgeNVNT3-DH12480MHzAnt1No-HoppingRef BandEdgeNVNT3-DH12480MHzAnt1No-HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page39of68 BandEdge(Hopping) ConditionModeFrequency (MHz) AntennaHopping Mode MaxValue (dBc) Limit (dBc) Verdict NVNT1-DH12402Ant1Hopping-47.06-20Pass NVNT1-DH12480Ant1Hopping-46.69-20Pass NVNT2-DH12402Ant1Hopping-47.47-20Pass NVNT2-DH12480Ant1Hopping-47.73-20Pass NVNT3-DH12402Ant1Hopping-48.14-20Pass NVNT3-DH12480Ant1Hopping-47.05-20Pass ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page40of68 BandEdge(Hopping)NVNT1-DH12402MHzAnt1HoppingRef BandEdge(Hopping)NVNT1-DH12402MHzAnt1HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page41of68 BandEdge(Hopping)NVNT1-DH12480MHzAnt1HoppingRef BandEdge(Hopping)NVNT1-DH12480MHzAnt1HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page42of68 BandEdge(Hopping)NVNT2-DH12402MHzAnt1HoppingRef BandEdge(Hopping)NVNT2-DH12402MHzAnt1HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page43of68 BandEdge(Hopping)NVNT2-DH12480MHzAnt1HoppingRef BandEdge(Hopping)NVNT2-DH12480MHzAnt1HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page44of68 BandEdge(Hopping)NVNT3-DH12402MHzAnt1HoppingRef BandEdge(Hopping)NVNT3-DH12402MHzAnt1HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page45of68 BandEdge(Hopping)NVNT3-DH12480MHzAnt1HoppingRef BandEdge(Hopping)NVNT3-DH12480MHzAnt1HoppingEmission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page46of68 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNT1-DH12402Ant1-41.29-20Pass NVNT1-DH12441Ant1-39.58-20Pass NVNT1-DH12480Ant1-39.5-20Pass NVNT2-DH12402Ant1-38.81-20Pass NVNT2-DH12441Ant1-38.76-20Pass NVNT2-DH12480Ant1-40.2-20Pass NVNT3-DH12402Ant1-41.09-20Pass NVNT3-DH12441Ant1-41.44-20Pass NVNT3-DH12480Ant1-35.76-20Pass ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page47of68 Tx.SpuriousNVNT1-DH12402MHzAnt1Ref Tx.SpuriousNVNT1-DH12402MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page48of68 Tx.SpuriousNVNT1-DH12441MHzAnt1Ref Tx.SpuriousNVNT1-DH12441MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page49of68 Tx.SpuriousNVNT1-DH12480MHzAnt1Ref Tx.SpuriousNVNT1-DH12480MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page50of68 Tx.SpuriousNVNT2-DH12402MHzAnt1Ref Tx.SpuriousNVNT2-DH12402MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page51of68 Tx.SpuriousNVNT2-DH12441MHzAnt1Ref Tx.SpuriousNVNT2-DH12441MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page52of68 Tx.SpuriousNVNT2-DH12480MHzAnt1Ref Tx.SpuriousNVNT2-DH12480MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page53of68 Tx.SpuriousNVNT3-DH12402MHzAnt1Ref Tx.SpuriousNVNT3-DH12402MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page54of68 Tx.SpuriousNVNT3-DH12441MHzAnt1Ref Tx.SpuriousNVNT3-DH12441MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page55of68 Tx.SpuriousNVNT3-DH12480MHzAnt1Ref Tx.SpuriousNVNT3-DH12480MHzAnt1Emission ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page56of68 NumberofHoppingChannel ConditionModeAntennaHoppingNumberLimitVerdict NVNT1-DH1Ant17915Pass NVNT2-DH1Ant17915Pass NVNT3-DH1Ant17915Pass ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page57of68 HoppingNo.NVNT1-DH12441MHzAnt1 HoppingNo.NVNT2-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page58of68 HoppingNo.NVNT3-DH12441MHzAnt1 ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page59of68 DwellTime ConditionModeFrequency (MHz) AntennaPulse Time (ms) Total Dwell Time(ms) Burst Count Period Time (ms) Limit (ms) Verdict NVNT1-DH12441Ant10.364115.02431631600400Pass NVNT1-DH32441Ant11.626261.78616131600400Pass NVNT1-DH52441Ant12.868295.40410331600400Pass NVNT2-DH12441Ant10.386123.13431931600400Pass NVNT2-DH32441Ant11.637248.82415231600400Pass NVNT2-DH52441Ant12.871310.06810831600400Pass NVNT3-DH12441Ant10.37117.2931731600400Pass NVNT3-DH32441Ant11.618266.9716531600400Pass NVNT3-DH52441Ant12.874270.1569431600400Pass ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page60of68 DwellNVNT1-DH12441MHzAnt1OneBurst DwellNVNT1-DH12441MHzAnt1Accumulated ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page61of68 DwellNVNT1-DH32441MHzAnt1OneBurst DwellNVNT1-DH32441MHzAnt1Accumulated ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page62of68 DwellNVNT1-DH52441MHzAnt1OneBurst DwellNVNT1-DH52441MHzAnt1Accumulated ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page63of68 DwellNVNT2-DH12441MHzAnt1OneBurst DwellNVNT2-DH12441MHzAnt1Accumulated ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page64of68 DwellNVNT2-DH32441MHzAnt1OneBurst DwellNVNT2-DH32441MHzAnt1Accumulated ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page65of68 DwellNVNT2-DH52441MHzAnt1OneBurst DwellNVNT2-DH52441MHzAnt1Accumulated ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page66of68 DwellNVNT3-DH12441MHzAnt1OneBurst DwellNVNT3-DH12441MHzAnt1Accumulated ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page67of68 DwellNVNT3-DH32441MHzAnt1OneBurst DwellNVNT3-DH32441MHzAnt1Accumulated ReportNo.:SZNTT26020704E1-1 SZNTT-TR728-0Page68of68 DwellNVNT3-DH52441MHzAnt1OneBurst DwellNVNT3-DH52441MHzAnt1Accumulated

Test Report

ShenzhenNTTTestingTechnologyCo.,Ltd.ReportNo.:SZNTT26020704E1-1 SZNTT-TR838-0Tel:0755-27889935Web:http://www.ntt-testing.comPage1of31 TESTREPORT Applicant:ShenzhenHongshengRuidaTechnologyCo.,Ltd Address: Room402,No.7,Longyuan4Lane,LonggangCommunity, LonggangStreet,LonggangDistrict,ShenzhenCity,China Manufacturer:ShenzhenHongshengRuidaTechnologyCo.,Ltd Address: Room402,No.7,Longyuan4Lane,LonggangCommunity, LonggangStreet,LonggangDistrict,ShenzhenCity,China ProductName:Bluetoothbathroomspeakerbracket ModelNumber:HS02 Trademark:N/A FCCID:2BWJL-HS02 TestDate: May18,2026–Jun.04,2026 DateofReport: Jun.04,2026 TestResult: ThisdevicedescribedabovehasbeentestedbyNTT,andthetest resultsshowthattheequipmentundertest(EUT)isincompliance withtheStandardrequirements.Anditisapplicableonlytothetested sampleidentifiedinthereport. TestProcedureUsed: Standards:FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10-2020+Cor.1-2023 KDB558074D0115.247MeasGuidancev05r02 Preparedby(TestEngineer): CindyQin Reviewer(Supervisor): KenWu Approved(Manager): AbelYu ShenzhenNTTTestingTechnologyCo.,Ltd.ReportNo.:SZNTT26020704E1-1 SZNTT-TR838-0Tel:0755-27889935Web:http://www.ntt-testing.comPage2of31 TABLEOFCONTENT 1.GeneralInformation......................................................................................5 1.1.DescriptionofDevice(EUT).......................................................................................................................5 1.2.ChannelList..................................................................................................................................................5 1.3.Summaryoftestresult................................................................................................................................6 1.4.SpecialAccessoriesandAuxiliaryEquipment........................................................................................6 1.5.Testmode......................................................................................................................................................6 1.6.Testconfiguration.........................................................................................................................................7 1.7.BlockDiagram...............................................................................................................................................7 1.8.TestConditions.............................................................................................................................................7 1.9.MeasurementUncertainty(95%confidencelevels,k=2)......................................................................8 1.10.TestFacility..................................................................................................................................................8 1.11.TestEquipment...........................................................................................................................................9 2.Conductedemissionatthemainsterminalstest....................................11 2.1.Limit..............................................................................................................................................................11 2.2.TestSetup....................................................................................................................................................11 2.3.TestProcedure............................................................................................................................................11 2.4.TestResult..................................................................................................................................................12 3.RadiatedSpuriousEmissions...................................................................14 3.1.Limit..............................................................................................................................................................14 3.2.TestSetup....................................................................................................................................................15 3.3.TestProcedure............................................................................................................................................17 3.4.TestResult...................................................................................................................................................18 4.MaximumPeakOutputPower....................................................................24 4.1.Limit..............................................................................................................................................................24 4.2.TestSetup....................................................................................................................................................24 4.3.TestProcedure............................................................................................................................................24 4.4.TestResult...................................................................................................................................................24 5.-20dBBandwidthMeasurement...............................................................25 5.1.Limit..............................................................................................................................................................25 5.2.TestSetup....................................................................................................................................................25 5.3.TestProcedure............................................................................................................................................25 5.4.TestResult...................................................................................................................................................25 6.Carrier…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Wang Hongbo(Manager)
[email protected]Fax: 17665216133

Technical Contact

CELLT INC.Thompson Lim
[email protected]

1401 21ST ST# 12958 · United States

Test Firm

Shenzhen NTT Testing Technology Co., Ltd.Henry Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz800.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.