FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Linhai Yixin Photoelectric Technology Co.,Ltd/
  3. 2BWKC-081-1

2BWKC-081-1remote control

Linhai Yixin Photoelectric Technology Co.,Ltd
remote control - FCC ID 2BWKC-081-1 - Linhai Yixin Photoelectric Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 01, 2026
Application Purpose
Original Equipment
Equipment Note
remote control
Frequency Range
433.92000000 - 433.92000000
Company
Linhai Yixin Photoelectric Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

081-1-RF433RemoteControlTechnicalDescription 1.PowerSupply  Operateson3Vlithiumcoincellbattery(CR2025orequivalent)  Voltagerange:2.1V–3.6VDC  Low-powerdesignforextendedbatterylife 2.MicrocontrollerUnit(MCU)  MCUModel:STX650M  ManagesbuttoninputprocessingandRFsignalencoding  Integratedsleepmodeforreducedpowerconsumption  Operatesat433.92MHzcarrierfrequencysynchronization 3.RFTransmitterModule RFIC:STX650M Modulation:ASK(AmplitudeShiftKeying) Frequency:433.92MHz±150kHz DataRate:2-10kbps(configurableviaMCU) 4.AntennaDesign  IntegratedPCBtraceantenna  1/4wavelengthhelicalpatterndesign(tunedfor433MHzband)  Impedancematchingnetworkincludedon-board Antennatracelength:Optimizedforλ/4radiationefficiency This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. TRadiation Exposure Statement The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. . FCC ID:2BWKC-081-1

Attestation Statements

LocalRepresentativeLetter ForCertificationServiceintheUSA FederalCommunicationsCommission EquipmentAuthorizationDivision,ApplicationProcessingBranch 7435OaklandMillsRoad Columbia,MD21048 Towhomitmayconcern PursuanttoSection2.911(d)(7),oftheCommission’sRules(47C.F.R.)weattestasfollowsfor theproductlistedbelow: FCCIDModelname 2BWKC-081-1081-1,189-1,099-1,139-1,089-1,113-1, 019-1,201-1,190-1,107-1,207-1,215-1, 027-1,210-1,032-1,202-1,220-1,032-1, 216-1,127-1,141-1,193-1 Weherebyacknowledgeasfollows: i.bothsigneesconfirmthatthepointofcontactacceptsresponsibilitytoactasaUS- AmericanRepresentativeonbehalfoftheapplicant ii.thepointofcontactprovidesthephysicalU.S.addressandemailaslistedbelow iii.bothpartiesmaintaintherequirementsofthisagreementfornolessthanoneyear afterthegranteehasterminatedallmarketingandimportationortheconclusionof anyCommission-relatedproceedinginvolvingtheequipment. iv.Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,the granteeisobligatedtonotifytheFCCwithin30daysviathegrantingTCB. US-AmericanPointofContactApplicant/ApprovalHolder SignatureDate:2026-6-26SignatureDate:2026-6-26 CompanyName:GLOCERTSTECHNOLOGYINCLinhaiYixinPhotoelectric TechnologyCo.,Ltd FRN:00363397370038526133 ContactName:HuiyingFanKeyongSong Address:19784SUNKISSEDRIDGEDR, RIVERSIDE,CA92507UnitedStates 5/F,Bldg3,538DatianRd, DatianSubdistrict,Linhai, Zhejiang,China Phone:(626)588-803913705768017 Email:[email protected]@126.com

Cover Letter(s)

Linhai Yixin Photoelectric Technology Co.,Ltd Add: 5/F, Bldg 3, 538 Datian Rd, Datian Subdistrict, Linhai, Zhejiang, China Date: 2026-6-25 FCC ID: 2BWKC-081-1 Dear Sir/Madam, We, Linhai Yixin Photoelectric Technology Co.,Ltd Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, The difference for these models is the appearance and the number of keys used for each remote controllers, the difference does not affect EMC performance. Product name: remote control Model no.: 081-1, 189-1, 099-1, 139-1, 089-1, 113-1, 019-1, 201-1, 190-1, 107-1, 207-1, 215-1, 027- 1, 210-1, 032-1, 202-1, 220-1, 032-1, 216-1, 127-1, 141-1, 193-1 Sincerely, Name/Title: Keyong Song/legal person Company: Linhai Yixin Photoelectric Technology Co.,Ltd Address: 5/F, Bldg 3, 538 Datian Rd, Datian Subdistrict, Linhai, Zhejiang, China Phone: 13705768017 Fax: 13705768017 E-Mail: [email protected]

External Photos

Page 1 of 5FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. External Photos Photo 1 Photo 2 Page 2 of 5FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 3 Photo 4 Page 3 of 5FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 5 Photo 6 Page 4 of 5FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 7 Photo 8 Page 5 of 5FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 9 Photo 10 ------End------

ID Label/Location Info

Label FCCID:2BWKC-081-1

Internal Photos

Page 1 of 7FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Internal Photos Photo 1 Photo 2 Page 2 of 7FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 3 Photo 4 Page 3 of 7FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 5 Photo 6 Page 4 of 7FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 7 Photo 8 Page 5 of 7FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 9 Photo 10 Page 6 of 7FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 11 Photo 12 Antenna Page 7 of 7FCC ID: 2BWKC-081-1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 13 ------End------

RF Exposure Info

Page1of8ReportNo.:AiTDG-260623009W2 Note:Thisdevicehasbeentestedandfoundtocomplywiththestandard(s)listed,thistestreportmerelycorrespondstothe testsample.Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory.This reportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofDongguanYaxu(AiT)TechnologyLimited.Ifthere isaneedtoalterorrevisethisdocument,therightbelongstoDongguanYaxu(AiT)TechnologyLimited,anditshouldgivea priorwrittennoticeoftherevisiondocument.Thistestreportmustnotbeusedbytheclienttoclaimproductendorsement. DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang,Huangjiang,Dongguan,Guangdong,China. RFExposureevaluation ProductName: remotecontrol BrandName: N/A Model: 081-1 SeriesModel: 189-1,099-1,139-1,089-1,113-1,019-1,201-1,190-1,107-1, 207-1,215-1,027-1,210-1,032-1,202-1,220-1,032-1,216-1, 127-1,141-1,193-1 FCCID: 2BWKC-081-1 Applicant: LinhaiYixinPhotoelectricTechnologyCo.,Ltd Address: 5/F,Bldg3,538DatianRd,DatianSubdistrict,Linhai,Zhejiang, China Manufacturer: LinhaiYixinPhotoelectricTechnologyCo.,Ltd Address: 5/F,Bldg3,538DatianRd,DatianSubdistrict,Linhai,Zhejiang, China Standard(s): 47CFR§1.1310,47CFR§2.1093 KDB447498D01GeneralRFExposureGuidancev06 DateofReceipt: Jun.23,2026 DateofTest: Jun.23,2026~Jun.25,2026 IssuedDate: Jun.26,2026 IssuedBy: DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang,Huangjiang,Dongguan,Guangdong,China Tel.:+86-769-82020499Fax.:+86-769-82020495 Reviewedby:Approvedby: EmiyaLinSimbaHuang Page 2 of 8 ReportNo.:AiTDG-260623009W2 ReportReviseRecord ReportVersionIssuedDateNotes V1.0Jun.26,2026InitialRelease Page 3 of 8 ReportNo.:AiTDG-260623009W2 Contents 1GENERALINFORMATION.............................................................................................................................................4 1.1ENVIRONMENTALCONDITIONS........................................................................................................................................4 1.2GENERALDESCRIPTIONOFEUT......................................................................................................................................4 1.3TESTFACILITY...............................................................................................................................................................5 1.4MEASUREMENTUNCERTAINTY........................................................................................................................................6 2METHODOFMEASUREMENT......................................................................................................................................7 2.1APPLICABLESTANDARD.................................................................................................................................................7 2.2EVALUATIONMETHODANDLIMIT...................................................................................................................................7 2.3MANUFACTURINGTOLERANCE........................................................................................................................................8 2.4EVALUATIONRESULT......................................................................................................................................................8 2.5CONCLUSION................................................................................................................................................................8 Page 4 of 8 ReportNo.:AiTDG-260623009W2 1GENERALINFORMATION 1.1Environmentalconditions Duringthemeasurementtheenvironmentalconditionswerewithinthelistedranges: NormalTemperature:25°C RelativeHumidity:55% AirPressure:101kPa 1.2GeneralDescriptionofEUT ProductName:remotecontrol Model/Typereference:081-1 SerialModel: 189-1,099-1,139-1,089-1,113-1,019-1,201-1,190-1,107-1,207-1, 215-1,027-1,210-1,032-1,202-1,220-1,032-1,216-1,127-1,141-1, 193-1 Modeldifference: PCBboard,structureandinternalofthesemodel(s)arethesame,So noadditionalmodelsweretested. PowerSupply:DC3.0V(CR2025battery) Hardwareversion.:V1.0 Softwareversion.:V1.0 Testsample(s)ID:AiTDG-260623009-1 SRD433.92: Operationfrequency:433.92MHz ModulationTechnology:OOK AntennaType: PCBAntenna AntennaGain: 0dBi Remark:TheaboveDUT'sinformationwasdeclaredbymanufacturer.Formoredetailedfeatures description,pleaserefertothemanufacturer’sspecificationsortheUser'sManual. Page 5 of 8 ReportNo.:AiTDG-260623009W2 1.3TestFacility TestLaboratory: DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang,Huangjiang,Dongguan,Guangdong,China Thetestfacilityisrecognized,certifiedoraccreditedbythefollowingorganizations: CNAS-RegistrationNo:L6177 DongguanYaxu(AiT)technologyLimitedisaccreditedtoISO/IEC17025:2017generalRequirements forthecompetenceoftestingandcalibrationlaboratories(CNAS-CL01AccreditationCriteriaforthe competenceoftestingandcalibrationlaboratories)onApril18,2022 FCC-RegistrationNo.:362653DesignationNumber:CN1457 DongguanYaxu(AiT)TechnologyLimitedhasbeenregisteredandfullydescribedinareportfiledwith the(FCC)FederalCommunicationsCommission.TheacceptanceletterfromtheFCCismaintainedin ourfiles. IC-RegistrationNo.:6819ACABidentifier:CN0122 The3mSemi-anechoicchamberofDongguanYaxu(AiT)TechnologyLimitedhasbeenregisteredby CertificationandEngineeringBureauofIndustryCanadaforradioequipmenttestingwithRegistration No.:6819A A2LA-LabCert.No.:6317.01 DongguanYaxu(AiT)TechnologyLimitedhasbeenaccreditedbyA2LAfortechnicalcompetencein thefieldofelectricaltesting,andprovedtobeincompliancewithISO/IEC17025:2017General RequirementsfortheCompetenceofTestingandCalibrationLaboratoriesandanyadditionalprogram requirementsintheidentifiedfieldoftesting. Page 6 of 8 ReportNo.:AiTDG-260623009W2 1.4Measurementuncertainty Thedataandresultsreferencedinthisdocumentaretrueandaccurate.Thereaderiscautionedthat theremaybeerrorswithinthecalibrationlimitsoftheequipmentandfacilities.Themeasurement uncertaintywascalculate…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 31 ReportNo.:AiTDG-260623009W1 DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. TestReport ClientInformation: Applicant: LinhaiYixinPhotoelectricTechnologyCo.,Ltd Applicantadd.: 5/F,Bldg3,538DatianRd,DatianSubdistrict,Linhai,Zhejiang,China ProductInformation: ProductName:remotecontrol ModelNo.: 081-1,189-1,099-1,139-1,089-1,113-1,019-1,201-1,190-1,107-1,207-1, 215-1,027-1,210-1,032-1,202-1,220-1,032-1,216-1,127-1,141-1,193-1 BrandName:N/A FCCID:2BWKC-081-1 Standards: FCC47CFRPART15SUBPARTC15.231 PreparedBy: DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang,Huangjiang,Dongguan, Guangdong,China Tel.:+860755-230967639Fax.:+860755-230967639 DateofReceipt:Jun.23,2026DateofTest:Jun.23,2026~Jun.25,2026 DateofIssue:Jun.26,2026TestResult:Pass ThisdevicedescribedabovehasbeentestedbyDongguanYaxu(AiT)TechnologyLimited,andthe testresultsshowthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.And itisapplicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofDongguanYaxu(AiT) TechnologyLimited. Reviewedby:Approvedby: EmiyaLinSimbaHuang Page 2 of 31 ReportNo.:AiTDG-260623009W1 DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. 1Contents Page COVERPAGE 1CONTENTS2 2TESTSUMMARY4 2.1STATEMENTOFTHEMEASUREMENTUNCERTAINTY4 2.2MEASUREMENTUNCERTAINTY4 3TESTFACILITY5 3.1DEVIATIONFROMSTANDARD5 3.2ABNORMALITIESFROMSTANDARDCONDITIONS5 3.3TESTLOCATION5 4GENERALINFORMATION6 4.1GENERALDESCRIPTIONOFEUT6 5DESCRIPTIONOFTESTCONDITIONS8 5.1E.U.T.OPERATION8 5.2EUTPERIPHERALLIST9 5.3TESTPERIPHERALLIST9 6EQUIPMENTSLISTFORALLTESTITEMS10 7TESTRESULT12 7.1ANTENNAREQUIREMENT12 7.2TRANSMITTIME13 7.2.1Appliedprocedures/Limit13 7.2.2Testprocedure13 7.2.3Deviationfromstandard13 7.2.4Testsetup13 7.2.5Testresults14 7.3FIELDSTRENGTHOFFUNDAMENTAL&FIELDSTRENGTHOFUNWANTEDEMISSIONS15 7.3.1Testprocedure18 7.4OCCUPIEDBANDWIDTH&BANDEDGE27 7.5CONDUCTEDEMISSIONSATMAINSTERMINALS150KHZTO30MHZ29 7.5.1TestResult31 8PHOTOGRAPHS31 8.1RADIATEDEMISSIONTESTSETUP31 Page 3 of 31 ReportNo.:AiTDG-260623009W1 DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/Jun.26,2026ValidInitialrelease Page 4 of 31 ReportNo.:AiTDG-260623009W1 DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. 2TestSummary FCCRuleDescriptionofTestResult Section15.203 RSS-Gensection6.8 AntennaRequirement Pass Section15.207(a)ConductionEmissions N/A Section 15.205,15.209,15.231(b) RadiatedEmissions Pass Section15.231(c)OccupiedBandwidth Pass Section15.231(a)Transmittime Pass Note 1.TestaccordingtoANSIC63.10:2020. 2.Themeasurementuncertaintyisnotincludedinthetestresult. 3.Testresultsinothertestreport(RFExposureEvaluationReport) 2.1StatementoftheMeasurementUncertainty Thedataandresultsreferencedinthisdocumentaretrueandaccurate.Thereaderiscautionedthattheremay beerrorswithinthecalibrationlimitsoftheequipmentandfacilities.Themeasurementuncertaintywas calculatedforallmeasurementslistedinthistestreportacc.ToCISPR16–4“Specificationforradio disturbanceandimmunitymeasuringapparatusandmethods–Part4:UncertaintyinEMCMeasurements” andisdocumentedintheAiTqualitysystemacc.ToDINENISO/IEC17025.Furthermore,componentand processvariabilityofdevicessimilartothattestedmayresultinadditionaldeviation.Themanufacturerhasthe soleresponsibilityofcontinuedcomplianceofthedevice. 2.2MeasurementUncertainty TestItemFrequencyRangeMeasurementUncertaintyNotes RadiatedEmission0.009MHz-30MHz3.10dB(1) RadiatedEmission30MHz-1GHz3.75dB(1) RadiatedEmission1GHz-18GHz3.88dB(1) RadiatedEmission18GHz-40GHz3.88dB(1) ACPowerLineConducted Emission 0.15MHz~30MHz1.20dB(1) OccupiedChannelBandwidth0.009MHz-18GHz0.20dB(1) Note(1):Themeasurementuncertaintyisforcoveragefactorofk=2andalevelofconfidenceof95%. Page 5 of 31 ReportNo.:AiTDG-260623009W1 DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. 3TestFacility Thetestfacilityisrecognized,certifiedoraccreditedbythefollowingorganizations: CNAS-RegistrationNo:L6177 DongguanYaxu(AiT)technologyLimitedisaccreditedtoISO/IEC17025:2017generalRequirements forthecompetenceoftestingandcalibrationlaboratories(CNAS-CL01AccreditationCriteriaforthe competenceoftestingandcalibrationlaboratories)onApril18,2022 FCC-RegistrationNo.:362653DesignationNumber:CN1457 DongguanYaxu(AiT)technologyLimitedhasbeenregisteredandfullydescribedinareportfiledwith the(FCC)FederalCommunicationsCommission.TheacceptanceletterfromtheFCCismaintained inourfiles. IC-RegistrationNo.:6819CABidentifier:CN0122 The3mSemi-anechoicchamberofDongguanYaxu(AiT)technologyLimitedhasbeenregisteredby CertificationandEngineeringBureauofIndustryCanadaforradioequipmenttestingwithRegistration No.:6819A A2LA-LabCert.No.:6317.01 DongguanYaxu(AiT)technologyLimitedhasbeenaccreditedbyA2LAfortechnicalcompetencein thefieldofelectricaltesting,andprovedtobeincompliancewithISO/IEC17025:2017General RequirementsfortheCompetenceofTestingandCalibrationLaboratoriesandanyadditional programrequirementsintheidentifiedfieldoftesting. 3.1Deviationfromstandard None 3.2Abnormalitiesfromstandardconditions None 3.3TestLocation DongguanYaxu(AiT)TechnologyLimited Address:B1/F,Building11,JunfengIndustrialPark,ChongqingRoad,HepingCommunity,FuhaiStreet,Bao'an District,Shenzhen,Guangdong,China. Tel.:+860755-230967639 Fax.:+860755-230967639 Page 6 of 31 ReportNo.:AiTDG-260623009W1 DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. 4GeneralInformation 4.1GeneralDescriptionofEUT Manufacturer:LinhaiYixinPhotoelectricTechnologyCo.,Ltd ManufacturerAddress:5/F,Bldg3,538DatianRd,DatianSubdistrict,Linhai,Zhejiang,China EUTName:remotecontrol Testsample(s)ID: AiTDG-260623…

Text truncated - open the document above for the full version.

Test Report

Antennadescribe Manufacturer:LinhaiYixinPhotoelectricTechnologyCo.,Ltd Add:5/F,Bldg3,538DatianRd,DatianSubdistrict,Linhai,Zhejiang,China PCB-LAYOUTantenna 1)Antenna Antennagain:0dBi Antennatype:PCB-LAYOUTantenna Frequencyrange:2.4GHZ-2.5GHZ

Test Setup Photos

Page1of2 FCCID:2BWKC-081-1 DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. TestSetupPhoto RadiatedEmission Page2of2 FCCID:2BWKC-081-1 DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. RFConduction ------End------

Contact Information

Applicant

Keyong Song(legal person)
[email protected]Fax: 13705768017

Technical Contact

GLOCERTS TECHNOLOGY INCHuiying Fan
[email protected]

19784 SUNKISSED RIDGE DR · United States

Test Firm

Dongguan Yaxu (AiT) Technology LimitedCoin Tang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term