2BWMD-KS17DWireless Kitchen Scale with Split Display

Shenzhen Faray InfoTech Co.,Ltd
Wireless Kitchen Scale with Split Display - FCC ID 2BWMD-KS17D - Shenzhen Faray InfoTech Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 09, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless Kitchen Scale with Split Display
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Faray InfoTech Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

IMPORTANTSAFEGUARDS Pleasereadandfollowallinstructionsandsafetyguidelinesinthismanual. •Donotexceedthe33lb/15kgweightcapacity,asitwilldamagethescale.Anerrorindicatorwill appearontheLEDdisplayifthelimitisexceeded. •Donotimmersethescalebodyinwateroranyliquid.Ifliquidisspilledonthedigitaldisplayorbuttons, immediatelywipethescaledrywithasoftclothtoavoidinternaldamage. •Handlewithcare.Thisscaleisnotintendedforcommercialorheavy-dutyuse. •Keepthescaleinacool,dryplace.Avoidexposuretodampenvironmentsorextremetemperatures. •Householduseonly. GETTINGTOKNOWYOURKITCHENSCALE 1.PRODUCTDIAGRAM 1.Weighingplatform 2.Charging&ConnectionContacts 3.USB‑CChargingPort 4.ScaleResetButton 5.PowerButton 6.UnitSelection 7.TareButton 8.Charging&ConnectionContacts 9.DisplayResetButton 1.Bluetoothconnectionstatusicon 2.Batteryindicatorforscalebody 3.Tareindicator 4.Batteryindicatorfordisplaymodule 5.Weightcapacityindicator 6.SPECIFICATIONS WeightCapacity33lb/15kg FCCIDforscalebody2BWMD-KS17 FCCIDfordisplaymodule2BWMD-KS17D Unitslb:oz-oz-g-ml-floz-ml(milk)-floz(milk) Increments1g/0.05oz AutoOff3minutes,adjustable BatteryLi-ionRechargeableBattery ChargingMethod5V⎓1A(USB‑C) OperatingTemperature41°–104°F/5°–40°C OperatingHumidity35%–80% OPERATINGINSTRUCTIONS BatteryCharging Itisrecommendedtochargetheproductbeforefirstuse. 1.Placethedisplaymodulebackontothescalebody,ensuringthemetalCharging&Connection Contactsareproperlyalignedandfullyconnected.. 2.InserttheUSBchargingcableintotheUSB‑Cchargingport. 3.Plugthecableintoa5VDCadapter,thenplugtheadapterintoawalloutlet.Youcanalsoplugthe cableintoapoweredUSBport. Note:Thedisplaymodulehasnochargingport.Itcanonlybechargedwhenplacedbackontothescale body. StatusDescription Lowbattery(below10%):Youcankeep usingthescale,butwerecommend chargingittoensureuninterrupteduse. Chargingcomplete:Thebatteryisfully charged. GeneralOperation Note: •Foraccurateresults,alwaysplacethescaleonahard,flatsurface,andkeepthescaleawayfromdirt, dust,vibrations,wind,aircurrents,andelectromagneticinterference. •Whenyouturnonthescale,chooseunits,orusethetarefunction,waitforthedisplaytoread“0”before measuring. PowerOn/Off Poweron:Tap""toturnonthescale. Poweroff:Toconservebatterypower,thescalewillautomaticallyturnoffafter180secondsofinactivity.Or youcanpressandholdthe""for2secondstomanuallyturnoffthedigitalscaleatanytime. Pairingwiththescale 1.Afterturnonthescaleandthedisplaymodulewillpairingwiththescalebodyautomatically. 2.Pairingusuallytakesabout3seconds.Ifthescaleisunstableorduetootherfactors,pairingmaytake longer. Note:Whendisplaymoduleisplacedbackonthescale,italsoworknormallywithoutpairingwiththescale -evenifpairingfails. Weighing Thisscalesupportstwoweighingmodesbasedonyourneeds. DisplayDockedMode: Placethedisplaymodulebackintothescalebodyuntilitalignsandsitsfirmly.Youcanweighnormally. Note:EveniftheBluetoothconnectionisnotestablished,thescalecanstillweighnormallywhiledocked. DisplaySplitSyncMode:Easyreadingforweighinglargeitemsorlargebowls. 1.Removethedisplaymodulefromthescalebodyandplaceitwhereyoucanreaditeasily(toavoidbowls blockingtheview). 2.Afteryouturnonthescale,thedisplaymodulewillautomaticallypairwiththescalebody.Thenyoucan weighnormally. UnitSwitch TaptheUNITbuttontoselectyourdesiredunit. TareFunction Wheneveryoumeasureliquidoritemsinsideacontainer,youcanusethetarefunctiontoremovethe container'sweightfromthetotalmeasurement. 1.Placeanemptycontaineronthescale.Thedisplaywillshowthecontainer'sweight. 2.TaptheTAREbutton.Thedisplaywillshow“0”again. 3.Placeliquidorfooditemsinthecontainer.Thescalewillnowmeasuretheliquidoritems,without includingtheweightofthecontainer.Whenyou'redone,resetthescalebyremovingalltheweightand tappingtheTarebutton. Adjustableauto-offtime PressandholdtheUNITbuttonfor2secondstoadjusttheautopower-offtime.Thedefaultsettingist-3. 1.TaptheUNITbuttontocyclethrought-5,t-8,andt-3. 2.Afterselecting,pressthe“”buttontoconfirmandreturntothenormaldisplay. WeightCapacityIndicator TheWeightCapacityIndicatorshowshowmuchofthescale’scapacityisbeingused(0–11lb/0–5kg). Ifoverloaded,theoverloadmessage"O_Ld"appearsonthedisplay. MAINTENANCE •Useaslightlydampclothtocleanthesurface,followedbyadry,softclothtowipeawaytheremaining moisture. •Donotwashthescalebodyorimmerseitinwateroranyotherliquid. TROUBLESHOOTING ERRORMESSAGEREASONSOLUTION "O_Ld"Scaleoverload.Maximumweightcapacity: 33lb/15kg. Removetheobjectfromthescaletoavoiddamag "Lo"orDisplayis verydim Batterypowerislow.Shuttingdown soon. Charingthebatteries. "No-Con" Displaymodule can’tpairwith thescalebody. 1.Thedevicesaretoofarapart. 2.Lowbatterycausinganunstable connection. 3.TheBluetoothmoduleisinan abnormalstate 1.Makesurethedevicesiswithin30ft/10m. 2.Pleasechargethescale. 3.PresstheResetbuttonwithasafetypinorpaperclip torestartthescalebodyordisplaymoudle, Thescaledoesn’t turnon lowbatteryorsoftwaremalfunctionor othercauses 1.PresstheResetbuttonwithasafetypinorpaperclip torestartthescalebodyordisplaymoudle, 2.Chargethescale. Readingis inaccurate. 1.IncorrectOperationorthesurface isunevenorunstable 2.Environmentalinterference(e.g., airflowfromafanorhighhumidity). 1.Placescaleonalevelsurface.andmakesurethe screendisplays“0”beforemeasuringorkeepscale awayfromdirt,dust,vibrations,wind,aircurrents, andelectromagneticinterference. 2.Iftheproblempersists,resetthescaleandcheck thattheweighingplatformisattachedproperly. Thedisplaymodule cannotcharged 1.Thedisplaymoduleisnotproperly seatedonthescalebody,andthemetal contactsarenotmakinggoodcontact 2.Dirt,oil,oxidation,ormoistureon thecontactsmayalsopreventcharging. 1.Ensurethedisplaymodulemagnetsarealignedandthe metalchargingcontactsarewellconnected. 2.Cleanthemetalcontactswithadry,softclothand keepthemdry. Ifyourproblemisnotlisted,[email protected]. FCCSTATEMENT NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttopart15oftheFCCRules.Theselimitsare designedtoprovidereasonableprotectionagainstharmfulinterferenceina residentialinstallat…

Text truncated - open the document above for the full version.

Attestation Statements

(ShenzhenFarayInfoTechCo.,Ltd) Rev2026-04-24 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:08-28-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)andPart2.911(d)(5)(ii) FCCID:2BWMD-KS17D Part2.911(d)(5)(i) [ShenzhenFarayInfoTechCo.,Ltd](“theapplicant”)certifiesthattheequipmentforwhichauthorization issoughtisnot“covered”equipmentanddoesnotcontainanti-virussoftwareorcybersecuritysoftware prohibitedfromreceivinganequipmentauthorizationpursuantto47CFR2.903,KDB986446D01 CoveredEquipmentGuidance,andFCCCoveredList(www.fcc.gov/supplychain/coveredlist). Part2.911(d)(5)(ii) [ShenzhenFarayInfoTechCo.,Ltd](“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, EstrellaXu

Attestation Statements

Shenzhen Faray InfoTech Co.,Ltd U.S. Agent Designation for Service of Process - Certification Attestation Letter 8/28/2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID:2BWMD-KS17D Applicant FRN: 0038534962 Shenzhen Faray InfoTech Co.,Ltd(“the applicant”) certifies that, as of the date of the filing of the application,Global Product Services and Consultation LLCis our designated U.S. agent for service of process for the above referenced FCC ID. Shenzhen Faray InfoTech Co.,Ltdaccepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Global Product Services and Consultation LLCaccepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Global Product Services and Consultation LLC FCC Registration Number (FRN): 0033406703 Physical U.S. Company Address: 328 W Palm Ave. Monrovia, CA91016, USA Contact Person: Mr Michael Chan Contact No.: 626-366-4358 Agent Email Address: [email protected] Sincerely, Company: Shenzhen Faray InfoTech Co.,LtdDesignated Agent: Global Product Services and Consultation LLC Company Representative: Estrella XuDesignated Agent Representative: Michael Chan Title:Title:Technical Director Signature: Signature: Date : 08/30/2026 SC : 6086530

Attestation Statements

ShenzhenFarayInfoTechCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:08-28-2026 SUBJECT:FCCID:2BWMD-KS17D ToWhomItMayConcern: I,theundersigned,herebystatesthisequipmenthasbeentestedandfoundtocomply withthelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules,and willapplytheSupplier'sDeclarationofConformityproceduretotheclassB computerperipheralportionofthiscompositedevice.IunderstandthefollowingFCC requirements: 1.DevicessubjecttotheSDoCprocedurearerequiredtobetestedtoshow compliancewiththeFCCtechnicalregulationsbyarecognizedaccreditedtesting laboratory.ThetestinglaboratorymustbeaccreditedbyaCommissionapproved accreditationbodyordesignatedunderthetermsofagovernment-to-government MutualRecognitionAgreement(MRA).Alistingofthoseaccreditedtesting laboratoriesthathavebeenrecognizedbytheCommissionispublishedontheFCC Webpage:https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm(Selectthe "accredited"optiontosearchforFCCrecognizedaccreditedtestfirms.) 2.Pt2.1077containsthelistofinformationthatmustbeincludedintheSupplier's DeclarationofConformity,whichmustbesuppliedwitheachproductsold.The SDoCcomplianceinfoshallbeincludedintheUser’sManualorasaseparate sheet.Theinfomustcontainthename,address,andphonenumberofthe responsibleparty,whichmustbelocatedwithintheUnitedStates.Accordingto 2.909(b),theresponsiblepartyiseithertheManufactureroriftheproductis importedtheImporter. Regards, ShenzhenFarayInfoTechCo.,Ltd ------------------------------- (EstrellaXu)

Cover Letter(s)

Rev11/20/07 ShenzhenFarayInfoTechCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationof FCCID:2BWMD-KS17D PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName BlockDiagram Schematics OperationalDescription BlockDiagram Schematics OperationalDescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,Wealsorequestingthe commissiontograntshort-termconfidentialityrequestonthefollowingattachmentsuntil180 daysaftertheGrantDateofEquipmentAuthorizations. ExhibitTypeFileName Date:08-28-2026 Sincerely, EstrellaXu

Cover Letter(s)

ShenzhenFarayInfoTechCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7453OaklandMillsRoad Columbia,MD21046 Date:08-28-2026 SUBJECT:FCCApplicationfor(FCCID:2BWMD-KS17D) ToWhomItMayConcern: We,theundersigned,herebyauthorizeSamLvatEMTEK(DONGGUAN)CO.,LTD.on ourbehalf,toapplytotheFederalCommunicationsCommissiononourequipment.Any andallactscarriedoutbyEMTEK(DONGGUAN)CO.,LTD.onourbehalfshallhave thesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, Sincerely, EstrellaXu

External Photos

ReportNo.EDG2607200028E002Page1of4Ver.1.0 FCCID:2BWMD-KS17D ReportNo.EDG2607200028E002Page2of4Ver.1.0 ReportNo.EDG2607200028E002Page3of4Ver.1.0 ReportNo.EDG2607200028E002Page4of4Ver.1.0

ID Label/Location Info

FCC ID: 2BWMD-KS17D

Internal Photos

ReportNo.EDG2607200028E002Page1of4Ver.1.0 FCCID:2BWMD-KS17D ReportNo.EDG2607200028E002Page2of4Ver.1.0 ReportNo.EDG2607200028E002Page3of4Ver.1.0 BLEANT ReportNo.EDG2607200028E002Page4of4Ver.1.0

RF Exposure Info

ReportNo.EDG2607200028E00202RPage1of7Ver.1.0 TESTREPORT ProductName:WirelessKitchenScalewithSplitDisplay ModelNumber:KS17 FCCID:2BWMD-KS17D Preparedfor:ShenzhenFarayInfoTechCo.,Ltd Address:Room401,BlockA,XichuangTechnologyBuilding, No.7025,LiuxianAvenue,XiliCommunity,XiliStreet, NanshanDistrict,ShenzhenChina Preparedby:EMTEK(DONGGUAN)CO.,LTD. Address:1&2/F.,Building2,ZoneA,ZhongdaMarine BiotechnologyResearchandDevelopmentBase, No.9,XinchengAvenue,SongshanhuHigh-technology IndustrialDevelopmentZone,Dongguan,Guangdong, China TEL:+86-0769-22807078 FAX:+86-0769-22807079 ReportNumber:EDG2607200028E00202R Dateofsamplereceipt:July20,2026 Date(s)ofTests:July20,2026toAugust16,2026 Dateofissue:August17,2026 $二维码$ ReportNo.EDG2607200028E00202RPage2of7Ver.1.0 TableofContents 1.TESTRESULTCERTIFICATION...............................................................................................................................................3 2.EUTSPECIFICATION.................................................................................................................................................................5 3.TESTREQUIREMENT................................................................................................................................................................6 4.MEASUREMENTRESULT.........................................................................................................................................................7 ReportNo.EDG2607200028E00202RPage3of7Ver.1.0 1.TESTRESULTCERTIFICATION Applicant:ShenzhenFarayInfoTechCo.,Ltd Address: Room401,BlockA,XichuangTechnologyBuilding,No.7025,LiuxianAvenue, XiliCommunity,XiliStreet,NanshanDistrict,ShenzhenChina Manufacturer:ShenzhenFarayInfoTechCo.,Ltd Address: Room401,BlockA,XichuangTechnologyBuilding,No.7025,LiuxianAvenue, XiliCommunity,XiliStreet,NanshanDistrict,ShenzhenChina Factory:ZhongshanKangnuoElectronicsCo.,Ltd Address: 2F,No.9-1DongchengNorthRoad,XinshengVillage,Xiaolan,Zhongshan, Guangdong,China528400 EUT:WirelessKitchenScalewithSplitDisplay ModelName:KS17 Trademark:Ultrean MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT §15.247(i),§2.1093 PASS TheaboveequipmentwastestedbyEMTEK(DONGGUAN)CO.,LTD.Thetestdata,dataevaluation,test procedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththeprocedures giveninANSIC63.10(2020)andtheenergyemittedbythesampleEUTtestedasdescribedinthisreportisin compliancewiththerequirementsofFCCRulesFCC§15.247(i),§2.1093. Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport DateofTest:July20,2026toAugust16,2026 Preparedby: JessicaZhang/Editor Reviewer: WarrenDeng/ Supervisor Approve&AuthorizedSigner: SamLv/Manager ReportNo.EDG2607200028E00202RPage4of7Ver.1.0 ModifiedHistory VersionReportNo.RevisionDateSummary EDG2607200028E00202R/OriginalReport ReportNo.EDG2607200028E00202RPage5of7Ver.1.0 2. EUTSpecification CharacteristicsDescription Product:WirelessKitchenScalewithSplitDisplay ModelNumber:KS17 Sample:E2607200028-01 DeviceType: BLE DataRate: 1MbpsforGFSKmodulation Modulation: GFSK OperatingFrequency Range(s): 2402-2480MHz NumberofChannels: 40channels TransmitPowerMax: -4.44dBm(0.000360W) AntennaGain:1.84dBi Powersupply: DC5VfromUSB DC3.7Vfrombattery Evaluationapplied:MPEEvaluation SAREvaluation ReportNo.EDG2607200028E00202RPage6of7Ver.1.0 3. TestRequirement SAREvaluation Accordingto447498D01V06,systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission’sguidelines. RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,usingmeasurementsorcomputer simulation.WhenroutineSARevaluationisnotrequired,portabletransmitterswithoutputpowergreaterthan theapplicablelowthresholdrequireSARevaluationtoqualityforTCBapproval. OneantennaisavailablefortheEUT.Theminimumseparationdistanceis5mm. ReportNo.EDG2607200028E00202RPage7of7Ver.1.0 4. MeasurementResult Antennagain:1.84dBi Transmit Frequency (MHz) Mode Measured Power (dBm) Tuneup Power (dBm) Maxtune uppower (dBm) Calculation Result Calculation threshold(1 -gSAR) 2402GFSK(1M)-4.44-4±1-30.15543 2440GFSK(1M)-6.05-6±1-50.09883 2480GFSK(1M)-5.60-5±1-40.12543 AccordingtoKDB447498D01V06,nostand-alonerequiredforBLEantenna,andnosimultaneousSAR measurementisrequired. ***EndofReport***

Test Report

Thisreportisnotintendedasproofofcompliancewithsocietalrequirements;itisintendedsolelyforresearch,teaching,orinternalqualitycontrolpurposes. Note:ThisreportisissuedbyShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd.;itmaynotbereproducedwithoutthepriorwrittenpermissionofShenzhenMoore HuanyuCommunicationTechnologyCo.,Ltd.Thetestresultscontainedinthisreportareapplicableonlytospecificsamplesandparticulartests;theinformationhereincanbe verifiedandconfirmedonourwebsite. MORLAB ShenzhenMooreHuanyuCommunication TechnologyCo.,Ltd.¡China¡Shenzhen¡Bao'an District¡Baocheng,No.67,LongchangRoad,No.8 FeiyangTechnologyPark,Floors1–3,BuildingA Tel:+86-755-36698555 Fax:+86-755-36698525 Website:Http://www.morlab.cn Email:[email protected] Page1of12 ReportNumber:SZ22090074E01 TestReport Applicant : SampleName: model: trademark : brand: testingstandard : datereceived : TestDate : dateofissue : Preparedby XinhaiTechnology(Shenzhen)Co.,Ltd. Bluetoothmodule CSM92F25 N/A N/A GB/T9410-2008 2022-09-06 2022-09-07 2022-09-13 : FangJinshan signandissue: ChiShide ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad Tel:+86-755-36698555Fax:+86-755-36698525 Http://www.morlab.cn Website:Email: [email protected] Page2of12 ReportNumber:SZ22090074E01 Catalogue 1.essentialinformation.............................................................................................................3 1.1.ApplicantandManufacturerInformation...........................................................................3 1.2.SampleInformation ............................................................................................................3 2.testresult..............................................................................................................................4 2.1.References..........................................................................................................................4 2.2.SampleTestingConditions..................................................................................................4 2.3.uncertaintyofmeasurement..............................................................................................4 3.testresult ..............................................................................................................................5 3.1.gain ....................................................................................................................................5 AnnexA:SamplePhotographs ...................................................................................................6 AnnexB–RadiationDiagram.....................................................................................................8 AnnexC:TestingInstitutionInformation..................................................................................11 mattersneedattention.............................................................................................................12 ChangeRecord EditionDateChangeReason 1.0 2022-09-13Editioprinceps ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad Tel:+86-755-36698555Fax:+86-755-36698525 Http://www.morlab.cn Website:Email: [email protected] Page3of12 ReportNumber:SZ22090074E01 1.EssentialInformation Note:ProvidedbytheApplicantandtheManufacturer. 1.1.ApplicantandManufacturerInformation Applicant: XinhaiTechnology(Shenzhen)Co.,Ltd. Applicant'sAddress: 3rdFloor,BuildingT4,ShenzhenBayInnovationTechnologyCenter,NanshanDistrict,Shenzhen Manufacturer: N/A ManufacturerAddress: N/A 1.2.SampleInformation Frequencyrange: 2400MHz-2500MHz Polarizationmode: N/A IMEI : N/A SampleNumber: 2# remarks: 1.Fordetailedsampleinformation,pleaserefertotheusermanualprovidedbytheapplicantorthemanufacturer. . ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad Tel:+86-755-36698555Fax:+86-755-36698525 Http://www.morlab.cn Website:Email: [email protected] Page4of12 ReportNumber:SZ22090074E01 2.TestResult 2.1.References Primaryreferencedocumentationfortesting: Ordernu- mber DocumentnameDocumentTitle 1 GB/T9410-2008GeneralTechnicalSpecificationforMobileCommunicationAntennas 2.2.SampleTestingConditions Duringthetestingprocess,theenvironmentalconditionsshallfallwithinthespecifiedrange: Temperature°C): 10-30 Relativehumidity(%): 25-75 2.3.UncertaintyofMeasurement ThemeasurementuncertaintyshallbecalculatedinaccordancewiththeISOstandard"GuidetotheExpressionof UncertaintyinMeasurement"(GUM).Whenthetestresultcorrespondstoathresholdvalue,ourcompanywillprovide themeasurementuncertaintyandissueadeterminationresultbasedona95%confidenceinterval. Project Measurementuncertainty(dB) Gain Âą0.5 Voltagestanding-waveratio Âą0.2 TheexpandeduncertaintyisexpressedusingaK=2coveragefactoranda95%confidenceinterval. ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad Tel:+86-755-36698555Fax:+86-755-36698525 Http://www.morlab.cn Website:Email: [email protected] Page5of12 ReportNumber:SZ22090074E01 3.TestResult 3.1.Gain FrequencyMHz)GaindBi) 24001.84 24101.58 24201.24 24300.92 24400.81 24500.60 24600.28 2470-0.15 2480-0.65 2490-1.11 2500-1.47 ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad Tel:+86-755-36698555Fax:+86-755-36698525 Http://www.morlab.cn Website:Email: [email protected] Page6of12 ReportNumber:SZ22090074E01 AnnexA:SamplePhotographs 1.TestPhoto 2.Samplephoto ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,Buildi…

Text truncated - open the document above for the full version.

Test Report

ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad Tel:+86-755-36698555Fax:+86-755-36698525 Http://www.morlab.cn Website:Email: [email protected] Page10of12 ReportNumber:SZ22090074E01 Cut3 P o w e r ( d B m ) Angle(°) Scale:2/div Min:-20 Max:-2 0 180 30 210 60 240 90270 120 300 150 330 2400MHz 2410MHz 2420MHz 2430MHz 2440MHz 2450MHz 2460MHz 2470MHz 2480MHz 90 00 24 25 M M Hz Hz Phi=90° Cut1 P o w e r ( d B m ) Angle(°) Scale:5/div Min:-25 Max:0 0 180 30 210 60 240 90270 120 300 150 330 2400MHz 2410MHz 2420MHz 2430MHz 2440MHz 2450MHz 2460MHz 2470MHz 2480MHz 90 00 24 25 M M Hz Hz Theta=90° ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad Tel:+86-755-36698555Fax:+86-755-36698525 Http://www.morlab.cn Website:Email: [email protected] Page11of12 ReportNumber:SZ22090074E01 AnnexC:TestingInstitutionInformation 1.TestEquipmentList DevicenameManufacturerModelSerialnumber CalibrationDate Effectivedata Networkanalyzer AgilentE5071CMY461101402022.07.042023.07.03 4×4×4Full-WaveElectromagneticShielding Chamber ETSAMS-8923-150N/A2020.01.062023.01.05 AntennaTestingSystem ETSEMQ-100N/AN/AN/A ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. MORLABChina¡Shenzhen¡Bao'anDistrict,Baocheng67thNeighborhood Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad Tel:+86-755-36698555Fax:+86-755-36698525 Http://www.morlab.cn Website:Email: [email protected] Page12of12 ReportNumber:SZ22090074E01 MattersNeedAttention 1.Thereportisinvalidifitdoesnotbeartheofficialsealofthetestinginstitution. 2.Thesignaturesofthepreparerortheissueronthisreportareinvalid. 3.Anyalterationstothereportareinvalid. 4.Shouldyouhaveanyobjectiontothetestingreport,pleaseraiseitwiththetestingentitywithin15days fromthedateofreceiptofthereport. 5."P"indicates"Testresultscomplywithrequirements";"F"indicates"Testresultsdonotcomplywith requirements";"N/A"indicates"Therequirementdoesnotapplytothisproduct";"/"indicates"Nottested". TestLaboratoryBasicInformation LabName: ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. LaboratoryAddress: Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad,BaochengDistrict67,Bao' anDistrict,Shenzhen Telephone:+8675536698555 Fax: +8675536698525 Testedaddress Reportcompleted Name: ShenzhenMooreHuanyuCommunicationTechnologyCo.,Ltd. Address: Floors1–3,BuildingA,FeiyangTechnologyPark,No.8LongchangRoad,BaochengDistrict67, Bao'anDistrict,Shenzhen

Test Report

ReportNo.EDG2607200028E00201RPage1of54Ver.1.0 $二维码$ TESTREPORT ProductName:WirelessKitchenScalewithSplitDisplay ModelNumber:KS17 FCCID:2BWMD-KS17D Preparedfor:ShenzhenFarayInfoTechCo.,Ltd Address:Room401,BlockA,XichuangTechnologyBuilding,No. 7025,LiuxianAvenue,XiliCommunity,XiliStreet, NanshanDistrict,ShenzhenChina Preparedby:EMTEK(DONGGUAN)CO.,LTD. Address:1&2/F.,Building2,ZoneA,ZhongdaMarine BiotechnologyResearchandDevelopmentBase,No.9, XinchengAvenue,SongshanhuHigh-technology IndustrialDevelopmentZone,Dongguan,Guangdong, China TEL:+86-0769-22807078 FAX:+86-0769-22807079 ReportNumber:EDG2607200028E00201R Dateofsamplereceipt:July20,2026 Date(s)ofTests:July20,2026toAugust16,2026 Dateofissue:August17,2026 ReportNo.EDG2607200028E00201RPage2of54Ver.1.0 TableofContents 1TESTRESULTCERTIFICATION....................................................................................................................................3 2EUTTECHNICALDESCRIPTION....................................................................................................................................5 3SUMMARYOFTESTRESULT..........................................................................................................................................6 4TESTMETHODOLOGY.......................................................................................................................................................7 4.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS............................................................................................7 4.2MEASUREMENTEQUIPMENTUSED..........................................................................................................................7 4.3DESCRIPTIONOFTESTMODES............................................................................................................................9 5FACILITIESANDACCREDITATIONS..........................................................................................................................10 5.1FACILITIES.........................................................................................................................................................10 5.2EQUIPMENT...........................................................................................................................................................10 5.3LABORATORYACCREDITATIONSANDLISTINGS...............................................................................................10 6TESTSYSTEMUNCERTAINTY......................................................................................................................................11 7SETUPOFEQUIPMENTUNDERTEST..........................................................................................................................12 7.1RADIOFREQUENCYTESTSETUP1...................................................................................................................12 7.2RADIOFREQUENCYTESTSETUP2...................................................................................................................12 7.3BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM......................................................................................15 7.4SUPPORTEQUIPMENT..........................................................................................................................................15 8TESTREQUIREMENTS...................................................................................................................................................16 8.1DTS6DBBANDWIDTH..........................................................................................................................................16 8.2DTS99%BANDWIDTH..........................................................................................................................................19 8.3MAXIMUMPEAKCONDUCTEDOUTPUTPOWER.....................................................................................................22 8.4MAXIMUMPOWERSPECTRALDENSITY...............................................................................................................25 8.5UNWANTEDEMISSIONSINNON-RESTRICTEDFREQUENCYBANDS.................................................................28 8.6RADIATEDSPURIOUSEMISSION........................................................................................................................37 8.7CONDUCTEDEMISSIONSTEST............................................................................................................................50 8.8ANTENNAAPPLICATION......................................................................................................................................53 ReportNo.EDG2607200028E00201RPage3of…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Estrella Xu
[email protected]Fax: 13192297553

Technical Contact

Global Product Services and Consultation LLCMichael Chan
[email protected]

328 W Palm Ave ¡ Monrovia, California, 91016 ¡ United States

Test Firm

EMTEK (DONGGUAN) CO., LTD.Sam Lv
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz360.00 ÂľW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power.

Other Applications from Shenzhen Faray InfoTech Co.,Ltd

Foot Massager - FCC ID 2BWMD-MDFM12 - Shenzhen Faray InfoTech Co.,Ltd
2BWMD-MDFM12

Foot Massager

Sep 15, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Kitchen Scale with Split Display - FCC ID 2BWMD-KS17 - Shenzhen Faray InfoTech Co.,Ltd
2BWMD-KS17

Wireless Kitchen Scale with Split Display

Sep 09, 2026

Equipment Class

DTS - Digital Transmission System
2BWMD-KS22

Al Nutriscale Glow

Aug 04, 2026

Equipment Class

DTS - Digital Transmission System