FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen GuoShi Intellitech Co.,Ltd./
  3. 2BWOW-S-D03

2BWOW-S-D03FD Base 3

Shenzhen GuoShi Intellitech Co.,Ltd.
FD Base 3 - FCC ID 2BWOW-S-D03 - Shenzhen GuoShi Intellitech Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 07, 2026
Application Purpose
Original Equipment
Equipment Note
FD Base 3
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen GuoShi Intellitech Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

2 ①The motor should not be operated continuously for more than 10 minutes or for more than 30% of the operating time within a certain period of time to prevent the motor from overheating. ②When the headboard or footboard is raised, it is strictly forbidden to sit at the footboard, j ump on the Mattress, or engage in strenuous exercise. Do not put all your weight on the raised part. ③During operation of the Mattress, please ensure that there are no people, pets, or oth er i tems in the closed area of the Mattress frame and the gaps in the mattress to avoid injury or product damage. In case of any accident, please stop operation immediately. Remote control usage: When operating the remote control, press the buttons in sequence to avoid pressing multiple buttons at the same time, which may cause damage to the motor due to insufficient response. FD Base 3 User Manual Product Overview This product is a high-end health sleep system that integrates adjustable firmness, height and posture adjustment, and innovative water ripple massage. It dynamically optimizes support and massage rhythm, and integrates vital sign monitoring, zoned heating, and sleep report analysis. It aims to optimize your sleep quality through technology, bringing convenience and health to your life. Core functions: electric adjustment, firmness adjustment, vibration massage, water ripple massage, vital sign monitoring, and heating temperature control. Smart control: You can control the Mattress through various methods such as remote control, Tuya APP, WeChat mini program and smart speaker. Safety Precautions To ensure your safety, please read the following guidelines carefully before use and always adhere to them. 1.Electricity Safety Power supply check: Before connecting the power supply, please confirm that the voltage meets the product requirements and that the power cord and plug are intact. Operational restrictions: 3 2.Personnel and Maintenance Safety Children and pets: Keep the remote control out of reach of children. Children must use this product under adult supervision. Cleaning and Maintenance: Always unplug the power cord before cleaning or maintenance. Do not use harsh chemicals (such as gasoline or diesel) to clean the Mattress. General dust can be wiped off with a dry cotton cloth. Non-professional disassembly: Non-professionals are strictly prohibited from disassembling the structural components, motors, or control boxes of the Mattress to avoid causing irreparable damage. Installation and initialization Unpacking Inspection: After opening the package, please first check the product for any bumps or scratches, and check all accessories against the product accessory list to ensure they are complete. Assembly Requirements: Assembly requires at least two people. Do not pull or drag the Mattress, and avoid using the Mattress legs as a single support point when flipping the Mattress. Please strictly follow the diagrams or instruction videos in the instruction manual for assembly. Power Connection and Debugging: After installation, install the control box in the designated location and connect the motor cables and power supply. After powering on, use the remote control to perform a preliminary check to ensure that all functions such as lifting, firmness adjustment, and massage are operating normally. Button Usage Instructions After the device is powered on, the buttons next to the Mattress will light up and vibrate, then turn off. Press and hold the [+] button next to the Mattress to adjust the mattress firmness,release to stop. Press and hold the [-] button next to the Mattress to adjust the mattress softness,release to stop. Remote Control User Guide 1.Pairing Within 5 seconds of powering on the device, press and hold the [Pairing] button for 3-5 seconds to pair. The indicator light will flash and then turn off, indicating successful pairing. After successful pairing, you can use the remote control to adjust the device. If pairing fails for more than 5 seconds, please restart your device and pair again. Once paired, you can use the remote control to operate the device. 4 2.Usage •L Soft: Short press to continue softening the left bed; short press again to stop. Long press to soften the left bed; stop when released. The adjustment stops automatically when adjusted to maximum softness. •R Soft: Short press to continue softening the right bed; short press again to stop. Long press to soften the right bed; stop when released. The adjustment stops automatically when adjusted to maximum softness. •: Press and hold to adjust the lef backrest upward or downward until it reaches the highest or flat position. •: Press and hold to adjust the right backrest upward or downward until it reaches the highest or flat position. •: Press and hold to adjust the feet rest upward or downward until it reaches the highest or flat position. •Flat Mode: Press to reset the electric adjustment to a fully flat state. •Zero G /Read /Rise: Press to activate electric adjustment for "Zero Gravity Mode", "Reading Mode", "Get Up Mode" . •Sleep Mode: Press to activate "Sleep Mode", The full cycle lasts about 15 minutes. If interrupted within the first 4 minutes, the device will initialize for about 30 seconds and return the bed to a flat position. •Device Initialization: After powering on, the device will automatically initialize for approximately 30 seconds to 2 minutes, including electric frame and firmness adjustment airbag initialization. Do not operate the device during initialization. •: One-Key Full Reset. Press to stop firmness adjustment, turn off water wave, vibration, heating, and other functions, and reset the bed frame, smart wake-up function remains active. •Child Lock: Long-press to lock/unlock the remote control . •L Firm: Short press to continue firming up the left bed; short press again to stop. Long press to firm up the left bed; stop when released. The adjustment stops automatically when adjusted to maximum firmness. •R Firm: Sh…

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 Shenzhen GuoShi Intellitech Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-29-2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BWOW-S-D03 [Shenzhen GuoShi Intellitech Co.,Ltd.] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Shenzhen GuoShi Intellitech Co.,Ltd.] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name) Wentao Tang Rev 1/26/2023 Shenzhen GuoShi Intellitech Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06-29-2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BWOW-S-D03 [Shenzhen GuoShi Intellitech Co.,Ltd.] ce8rtifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Wentao Tang

Attestation Statements

Shenzhen GuoShi Intellitech Co.,Ltd. U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: June 29, 2026 Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BWOW-S-D03 Shenzhen GuoShi Intellitech Co.,Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, CLF Import and Export Limited (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. CLF Import and Export Limited ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: CLF Import and Export Limited FRN: 0033489683 Address: 1312 17th Street #692, Denver, CO 80202, United States Signature: Contact Person: David Chen Tel: +1 949 254 2565 Email: [email protected] Applicant Company Name: Shenzhen GuoShi Intellitech Co.,Ltd. FRN: 0038555124 Address: Guoshi Building 20/F, Shahe West Road, Nanshan, Shenzhen, China Signature: Contact Person: Wentao Tang Tel: 18823394669 Email: [email protected]

Cover Letter(s)

Shenzhen GuoShi Intellitech Co.,Ltd. Date: June 29, 2026 Product Model Number: S-D03 FCC ID: 2BWOW-S-D03 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following:  Testing  Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. Signature: By: Wentao Tang Title: Manager Tel.: 18823394669 Email: [email protected] On behalf of: Shenzhen GuoShi Intellitech Co.,Ltd.

Cover Letter(s)

Shenzhen GuoShi Intellitech Co.,Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: July 5, 2026 Subject; Request for Confidentiality FCC ID: 2BWOW-S-D03 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: By: Wentao Tang Title: Manager

External Photos

Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 1 of 10 Annex A. EUT External Photos Model: S-D03 EUT View 1 EUT View 2 Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 2 of 10 EUT View 3 EUT View 4 Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 3 of 10 EUT View 5 EUT View 6 Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 4 of 10 EUT View 7 EUT View 8

ID Label/Location Info

Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 10 of 10 Annex D. Label and Inf ormation FCC Label Sample Label Size: 4cm*2cm FCC Label Specifications Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Where the EUT is constructed in two or more sections connected by wires and marketed together, the above statement is required to be affixed only to the main control unit. When the EUT is so small or for such use that it is not practicable to place the statement on it, the above information shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. FCC Label Location

Internal Photos

Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 5 of 10 Annex B. EUT Internal Photos EUT Internal View 1 EUT Internal View 2 Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 6 of 10 EUT Internal View 3 EUT Internal View 4 FPCB ANT Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 7 of 10 EUT Internal View 5 EUT Internal View 6

RF Exposure Info

FCC ID: 2BWOW-S-D03 RF Exposure Evaluation According to KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Here, The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. For BLE Max Conducted Power(dBm) Tune-up Power(dBm) Max Tune-up Power(dBm) Max Power(mW) Frequency(MHz) Min. distance(mm) Calc. thresholds limit -2.6 -2(±1) -1 0.79 2440 5 0.2469 3.0 So a SAR test is not required

Test Report

Report No: SSP26040467-1E FCC Test Report Page 1 of 33 FCC TEST REPORT FCC ID: 2BWOW-S-D03 Report No. : SSP26040467-1E Applicant : Shenzhen GuoShi Intellitech Co.,Ltd. Product Name : FD Base 3 Model Name : S-D03 Test Standard : FCC Part 15.247 Date of Issue : 2026-06-22 Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China; (Tel.:+86-755-23406590 website: www.ccuttest.com) This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd. Report No: SSP26040467-1E FCC Test Report Page 2 of 33 Test Report Basic Information Applicant..................................: Shenzhen GuoShi Intellitech Co.,Ltd. Address of Applicant...............: Guoshi Building 20/F, Shahe West Road, Nanshan, Shenzhen, China Manufacturer..........................: Shenzhen GuoShi Intellitech Co.,Ltd. Address of Manufacturer........: Guoshi Building 20/F, Shahe West Road, Nanshan, Shenzhen, China Product Name.........................: FD Base 3 Brand Name.............................: Main Model..............................: S-D03 Series Models..........................: - Test Standard..........................: FCC Part 15 Subpart C KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.4-2014 ANSI C63.10-2020 + COR.1-2023 Date of Test .............................: 2026-05-25 to 2026-06-10 Test Result...............................: PASS Tested By ................................: (Tate Chen) Reviewed By............................: (Lorzix Luo) Authorized Signatory............: (Lahm Peng) Note : This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd.. All test data presented in this test report is only applicable to presented test sample. Report No: SSP26040467-1E FCC Test Report Page 3 of 33 CONTENTS 1. General Information ....................................................................................................................................................5 1.1 Product Information .............................................................................................................................................5 1.2 Test Setup Information..........................................................................................................................................6 1.3 Compliance Standards ...........................................................................................................................................7 1.4 Test Facilities ........................................................................................................................................................7 1.5 List of Measurement Instruments ..........................................................................................................................8 1.6 Measurement Uncertainty .....................................................................................................................................9 2. Summary of Test Results ........................................................................................................................................... 10 3. Antenna Requirement ............................................................................................................................................... 11 3.1 Standard and Limit.............................................................................................................................................. 11 3.2 Test Result .......................................................................................................................................................... 11 4. Conducted Emissions ................................................................................................................................................ 12 4.1 Standard and Limit.............................................................................................................................................. 12 4.2 Test Procedure.................................................................................................................................................... 12 4.3 Test Data and Results .......................................................................................................................................... 13 5. Radiated Emissions ................................................................................................................................................... 16 5.1 Standard and Limit.............................................................................................................................................. 16 5.2 Test Procedure.................................................................................................................................................... 16 5.3 Test Data and Results .......................................................................................................................................... 18 6. Band-edge Emissions(Radiated) ............................................................................................................................... 22 6.1 Standard and Limit.............................................................................................................................................. 22 6.2 Test Procedure.................................................................................................................................................... 22 6.3 Test Data and Results .......................................................................................................................................... 22 7. Maximum Peak Conducted Output Power ..................................…

Text truncated - open the document above for the full version.

Test Report

1. General Information 1.1 Antenna Information Manufacturer: Shenzhen GuoShi Intellitech Co.,Ltd. Address of Manufacturer: Guoshi Building 20/F, Shahe West Road, Nanshan, Shenzhen, China Product Name: 2.4GHz Antenna Model Name: S-D03 Frequency Range: 2400MHz - 2500MHz Type of Antenna: FPCB antenna Antenna Gain: 0dBi (Max.) Impedance: 50 ohm Antenna View: Unit: cm 2. Antenna Specification information 2.1 Gain Frequency Peak Gain (dBi) Polarity 2400MHz 0 Horizontal 2400MHz -0.54 Vertical 2450MHz -1.25 Horizontal 2450MHz -1.51 Vertical 2500MHz -1.68 Horizontal 2500MHz -1.27 Vertical 2.2 Radiation Pattern View

Test Setup Photos

Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 8 of 10 Annex C. Test Photos Conducted Emission Test View 1 Radiated Emission Test View 1 Report No: SSP26040467-1E FCC ID: 2BWOW-S-D03 Annex of Test Report Page 9 of 10 Radiated Emission Test View 2

Contact Information

Applicant

Wentao Tang
[email protected]Fax: 18823394669

Technical Contact

CLF Import and Export LimitedDavid Chen
[email protected]

1312 17th Street #692 · United States

Test Firm

Shenzhen CCUT Quality Technology Co., Ltd.Lahm Peng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz550.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.

Other Applications from Shenzhen GuoShi Intellitech Co.,Ltd.

FD Master Pro 3.2 - FCC ID 2BWOW-S-GD03 - Shenzhen GuoShi Intellitech Co.,Ltd.
2BWOW-S-GD03

FD Master Pro 3.2

Jul 13, 2026

Equipment Class

DTS - Digital Transmission System
FD Remote Pro 3 - FCC ID 2BWOW-U-Y-SGD03 - Shenzhen GuoShi Intellitech Co.,Ltd.
2BWOW-U-Y-SGD03

FD Remote Pro 3

Jul 09, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
FD Remote Base 3 - FCC ID 2BWOW-U-Y-SG02 - Shenzhen GuoShi Intellitech Co.,Ltd.
2BWOW-U-Y-SG02

FD Remote Base 3

Jul 09, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
FD Master Pro 3.1 - FCC ID 2BWOW-S-HE02 - Shenzhen GuoShi Intellitech Co.,Ltd.
2BWOW-S-HE02

FD Master Pro 3.1

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System