Safety Precautions / Precauciones de seguridad / Mesures de sécurité Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. / Solamente el personal calificado deberá instalar, hacer funcionar y prestar servicios de mantenimiento al equipo eléctrico. Schneider Electric no asume responsabilidad alguna por las consecuencias emergentes de la utilización de este material. / Seul un personnel qualifié doit effectuer l’installation, l’utilisation, l’entretien et la maintenance du matériel électrique. Schneider Electric n’assume aucune responsabilité des conséquences éventuelles découlant de l’utilisation de cette documentation. HAZARD OF MISUSE • Avoid installing this device in locations such as camper vans, cruise ships, or any sort of moving vehicle. • Do not use this product if the enclosure is broken, cracked, open, or shows any other indication of damage. • Do not expose this product to moisture. • Do not open device. No user serviceable parts inside. • Indoor use only. • Use only power supply provided. Failure to follow these instructions can result in equipment damage. IMÁN POTENTE E N USO • Evite instalar este dispositivo en lugares como cámpers, cruceros o cualquier tipo de vehículo en movimiento. • No utilice este producto si el gabinete está roto, agrietado, abierto o presenta cualquier otro indicio de daño. • No exponga el dispositivo a la humedad. • No abra el dispositivo. Las partes internas no pueden ser reparadas por el usuario. • Solo para uso en interiores. • Utilice únicamente la fuente de alimentación suministrada. El incumplimiento de estas instrucciones puede cau sar da ño a l e quipo. AI MANT PUISSANT EN UTILISATION • Évitez d’installer cet appareil dans des camping-cars, des bateaux de croisière ou tout autre véhicule en mouvement. • Ne pas utiliser ce produit si le boîtier est cassé, fissuré, ouvert ou présente des signes de dommages. • Ne pas exposer l’appareil à l’humidité. • Ne pas ouvrir l’appareil. Aucune pièce n’est réparable par l’ut ilisat eur. • Pour utilisation à l’intérieur uniquement. • Utilisez uniquement l’unité d’alimentation électrique fournie. Le non-respect de ces directives peut provoquer des dommages matériels. NOTICE / AVISO / AVIS WARNING: This product can expose you to chemicals including Carbon black, which is known to the State of California to cause cancer, and Bisphenol A (BPA) which is known by the state of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. Schneider Electric is a trademark and the property of Schneider Electric SE, its subsidiaries, and affiliated companies. All other trademarks are the property of their respective owners. / Schneider Electric este una marca comerciales y propiedad de Schneider Electric SE, sus filiales y compañías afiliadas. Todas las otras marcas comerciales son propiedad de sus respectivos propietarios. / Schneider Electric est une marque commerciales et la propriété de Schneider Electric SE, ses filiales et compagnies affiliées. Toutes les autres marques commerciales sont la propriété de leurs propriétaires respectifs. Schneider Electric USA, Inc. 800 Federal Street Andover, MA 01810 USA 888-778-2733 www.se.com/us/ Schneider Canada, Inc. 5985 McLaughlin Road Mississauga, ON L5R 1B8 Canada 800-565-6699 www.se.com/ca/ For additional assistance / support go to www.se.com/support Pour une assistance supplémentaire, rendez-vous sur : www.se.com/us/en / www.se.com/ca/fr 06/2026 JPT34405-00 for SAH211111 © 2026 Schneider Electric All Rights Reserved FCC Caution: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This device complies with ISED radiation exposure limits set forth for general population. This device must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or o…
Text truncated - open the document above for the full version.
Scan for set up and additional resources. Numérisez pour obtenir les instructions de configuration et des ressources supplémentaires.
Rev 1/26/2023 General Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: July 31, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BWOYSAH211111 Schneider Electric USA Inc (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Schneider Electric USA Inc (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, Schneider Electric USA Inc Christo Thomas Signature: Rev 1/26/2023 General Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: July 31, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BWOYSAH211111 Schneider Electric USA Inc (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Link: List of Equipment and Services Covered By Section 2 of The Secure Networks Act Sincerely, Schneider Electric USA Inc Christo Thomas Signature:
Rev 1/26/2023 General Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 15, 2026 Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: 2BWOY Schneider Electric USA Inc (“the applicant”) certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FRN: 0033569401 Name: Schneider Electric USA Inc Address: 3700 6TH ST SW, Cedar Rapids Iowa , United State Contact Person: Christo Thomas Tel.: 319) 369-6553 Email: [email protected] Sincerely, Schneider Electric USA Inc Christo Thomas Private Sector , Corporation
General CONFIDENTIALITY REQUEST To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046-1609 Cc: IIA Lab Services, LLC. 13146 NW 86th Drive, Suite 400 Alachua, FL 32615- United States July 31, 2026 Subject: Confidentiality request FCC ID: 2BWOYSAH211111 Schneider Electric USA Inc requests, pursuant to 47CFR 0.457 and 0.459, post grant confidentiality for portions of the material contained in this application. The following document regarding this submission for FCC ID: 2BWOYSAH211111 shall be kept confidential: LONG-TERM CONFIDENTIALITY: 1. Block Diagram description of the equipment (file: Block Diagram - 2BWOYSAH211111.pdf) 2. Schematic Diagram of the equipment (file: Schematic -2BWOYSAH211111.pdf) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Responsible party: Christo Thomas Title: Private Sector , Corporation Signature:
General COVER LETTER Schneider Electric USA Inc – Energy Intelligence Control Unit FCC ID: 2BWOYSAH211111 July 31, 2026 This report concerns: File : Original Grant SubPart: SubPart 15B and 15C Equipment type : Energy Intelligence Control Unit Request issue of grant : __ Immediately upon completion of review ___ Defer grant per 47 CFR 0.457(d)(1)(ii) until ____ date _____. Company Name agrees to notify the Commission by _____date_____ of the intended date of announcement of the product so that the grant can be issued on that date. Confidentiality of grant : __ Applicant requests the existence of this grant to be kept confidential until ____date____. The announcement of this product before this date via freedom of information would be detrimental to Company Name, and therefore must be considered a business secret. Public announcement of this product will not be made prior to this date. (Max. 60 days after grant issued). Limits used : (check one) CISPR 22: ___ ___ Part15: ______ Measurement procedure used is ANSI C63.10-2020 + Cor. 1-2023 + C63.10a-2024 + Errata to C63.10a-2024 unless another is specified. Other test procedure : ____________________________________________________ Application for verification Applicant for this device Prepared by : Majid MOURZAGH LCIE Sud-Est ZI Centr’Alp – 170, rue de Chatagnon 38430 MOIRANS - France Ph. : 33 4 76 07 36 36 Fax : 33 4 76 55 90 88 e- mail : [email protected] FRN : 0005-0971-18 Christo Thomas Schneider Electric USA Inc 3700 6TH ST SW N/A - Cedar RapidsIowa - United State Ph. : +33 (319) 369-6553 Fax : +33 / e- mail: [email protected] FRN : 0033569401 Signature : Signature : *Not to be filed with Equipment Authorization Branch of FCC unless requested Report format prepared by the Information Technology Industry Council (ITI) ESC-5 and reviewed by FCC staff in 1994
General Date: July 31, 2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046-1609 SU BJECT: A ttestation statement modules per manufacturers instruction. FCC ID: 2BWOYSAH211111 Brand/Trade Name: Schneider Electric USA Inc Model Number: Energy Intelligence Control Unit We, Schneider Electric USA Inc, hereby attest and confirm that the certified radio modules identified on our product and any associated antennas, cables, or accessories have been installed and integrated into the host product strictly in accordance with the module manufacturer's installation instructions without any deviation. This complies with 47 CFR §15.212 requirements for maintaining module compliance in t he end product. Should you have any question, feel free to contact me directly. Sincerely yours, - ---------------------------------- Christo Thomas +1 (319) 369-6553 [email protected]
Letter of Agency July 31, 2026 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046-1609 IIA Lab Services, LLC. 13146 NW 86th Drive, Suite 400 Alachua, FL 32615- United States We, the undersigned Schneider Electric hereby authorizes Majid MOURZAGH, LCIE SUD EST, to act on our behalf in all matters relating to all processes required for FCC certification of our devices. Any and all acts carried out by the above agent on our behalf shall have the same effects as acts of our own. This authorization is valid until: December 31th, 2026 If you have any questions regarding this authorization, let us know please. Sincerely, Christo Thomas Signature:
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 1/6 EXTERNAL PHOTOS OF EQUIPMENT FCCID: 2BWOYSAH211111 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 2/6 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 3/6 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 4/6 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 5/6 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 6/6
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 1/1 PRODUCT LABELING FCCID: 2BWOYSAH211111 Label location
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 1/15 INTERNAL PHOTOS OF EQUIPMENT FCCID: 2BWOYSAH211111 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 2/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 3/15 ZigBee Antenna WiFi Antenna LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 4/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 5/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 6/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 7/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 8/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 9/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 10/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 11/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 12/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 13/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 14/15 LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – France Page 15/15
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – FRANCE FCCID: 2BWOYSAH211111 RF Exposure Information When all the antennas are at least 20cm away from the user’s body (excluding hands and wrists during normal operation of the device), but individual antennas cannot be separated by more than 20cm from each other. [ Pd(1) / LPd(1) ] + [ Pd(2) / LPd(2) ] + ..... + [ Pd(n) / LPd(n) ] < 1, Where; Pd(n) = Power density of n th transmitter at 20cm LPd(n) = Power density limit for the n th transmitter § 1.1310 Radiofrequency radiation exposure limits. Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna 2 4 R PG S p = LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS – FRANCE Calculations: For transmitter: Frequency: 2437.00 Prediction distance: 20.00 Output Power: 21.10 Antenna gain(typical): 2.90 1.00 Calculation: 21.10 (dBm) 128.82 (mW) 2.90 (dBi) 1.95 (numeric) 20.00 (cm) 2437.00 (MHz) 1.00 (mW/cm^2) 0.05 (mW/cm^2) For transmitter: Frequency: 2440.00 Prediction distance: 20.00 Output Power: -27.63 Antenna gain(typical): 0.00 1.00 Calculation: -27.63 (dBm) 0.00 (mW) 0.00 (dBi) 1.00 (numeric) 20.00 (cm) 2440.00 (MHz) 1.00 (mW/cm^2) 0.0000003 (mW/cm^2) Calculation : Colocation: <1 at the antenna terminal (dBm) cm (Portable:0.5cm / Mobile:20cm) MHz WIFI 2.4GHz MPE limit for uncontrolled exposure at prediction frequency: (dBi) MPE limit for uncontrolled exposure at prediction frequency: Power density at prediction frequency: Maximum peak output power at the antenna terminal: Maximum peak output power at the antenna terminal: Antenna gain(typical): Maximum antenna gain: Prediction distance: Prediction frequency: MPE limit for uncontrolled exposure at prediction frequency: 802.15.4 MHz cm (Portable:0.5cm / Mobile:20cm) at the antenna terminal (dBm) (dBi) MPE limit for uncontrolled exposure at prediction frequency: Power density at prediction frequency: (Pd(2.4GHz) / LPd(2.4GHz)) + (Pd(FM) / LPd(FM)) = 0.0141 mW/cm² <1 0.05 Maximum peak output power at the antenna terminal: Maximum peak output power at the antenna terminal: Antenna gain(typical): Maximum antenna gain: Prediction distance: Prediction frequency: Conclusion: The device complies with FCC’s RF radiation exposure limit for general population as a mobile device (d>20cm) under the collocation conditions described above.
Template : February 2 nd , 2026 Reproduction of this document is only authorized in its complete form. Any partial reproduction or any insertion of results in an accompanying text with a view to their distribution must receive prior and formal agreement from LCIE. This document results from tests carried out on a specimen, sample or test piece. It does not prejudge the conformity of all the products manufactured to the object tested. Unless otherwise indicated or rule specified by the test method, the decision of conformity does not take into account measurement uncertainty. It in no way prejudges a certification decision. The accreditation of the COFRAC Testing Section attests to the technical competence of the laboratories for the tests covered by the accreditation only. If certain tests mentioned in this report were carried out outside the framework of COFRAC accreditation, they are identified by the symbol . LCIE Laboratoire Central des Industries Electriques Une société Bureau Veritas Z.I Centr'alp 170, Rue de Chatagnon 38430 Moirans FRANCE Tél. + 33 4 76 07 36 36 [email protected] www.lcie.fr SAS au capital de 15 745 984€ / RCS Nanterre B 408 363 174 / N° TVA intracommunautaire FR01 408 363 174 / N°SIRET 408 363 174 00017 Accreditation N°1-7429 Scope available on www.cofrac.fr TEST REPORT N°: 32173710-823886-A(FILE#13683292) Version: 02 Subject Radio spectrum tests according to the standards: FCC CFR 47 Part 15.247 ANSI C63.10-2020 + Cor. 1-2023 + C63.10a-2024 + Errata to C63.10a-2024 RSS-247 & RSS-Gen Issued to Schneider Electric USA Inc 3700 6TH ST SW Cedar RapidsIowa United State Apparatus under test Product Energy Intelligence Control Unit Trade mark SCHNEIDER ELECTRIC Manufacturer SCHNEIDE ELECTRIC INDUSTRIES SAS Family range Intelligence Hub Model under test Energy Intelligence Control Unit Serial number EP142 FCCID 2BWOYSAH211111 IC 36030-SAH211111 Conclusion See Test Program chapter Test date May 12, 2026 to May 18, 2026 Test location LCIE Grenoble FCC Test site FR0008 - 918017 (MOI) ISED Test site 6500A – FR0008 (MOI) Sample receipt date May 12, 2026 Composition of document 53 pages Document issued on September 14, 2026 Written by : Approved by : Marlon BOUBY Majid MOURZAGH Tests operator Technical manager TEST REPORT N°32173710-823886-A(FILE#13683292) Version : 02 Page 2/53 PUBLICATION HISTORY Version Date Author Modification 01 September 02, 2026 Majid MOURZAGH / Marlon BOUBY Creation of the document 02 September 14, 2026 Marlon BOUBY In §2.1, add the FCC ID and IC number of the Wi‑Fi module. Each new edition of this test report replaces and cancels the previous edition. The control of the old editions of report is under responsibility of client. TEST REPORT N°32173710-823886-A(FILE#13683292) Version : 02 Page 3/53 SUMMARY 1. TEST PROGRAM ............................................................................................................................. 4 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) .............................. 5 3. LABORATORY EQUIPMENT AND METHODOLOGY .................................................................... 11 4. OCCUPIED BANDWIDTH ............................................................................................................... 13 5. 6DB BANDWIDTH .......................................................................................................................... 17 6. MAXIMUM CONDUCTED OUTPUT POWER ................................................................................. 21 7. POWER SPECTRAL DENSITY ...................................................................................................... 25 8. UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS ..................................... 29 9. UNWANTED EMISSIONS IN RESTRICTED FREQUENCY BANDS .............................................. 34 10. UNCERTAINTIES CHART .............................................................................................................. 52 TEST REPORT N°32173710-823886-A(FILE#13683292) Version : 02 Page 4/53 1. TEST PROGRAM References ➢ 47 CFR Part 15.247 (April 16, 2026) ➢ RSS 247 Issue 4 ➢ RSS Gen Issue 5 ➢ KDB 558074 D01 DTS Meas Guidance v05r02 ➢ KDB 662911 D01 Multiple Transmitter Output v02r01 ➢ ANSI C63.10-2020 + Cor. 1-2023 + C63.10a-2024 + Errata to C63.10a-2024 Radio requirement: Clause - Test Description Test result - Comments Occupied Bandwidth ISED PASS 6dB Bandwidth FCC & ISED PASS Maximum Conducted Output Power FCC & ISED PASS Power Spectral Density FCC & ISED PASS Unwanted Emissions in Non-Restricted Frequency Bands FCC & ISED PASS Unwanted Emissions in Restricted Frequency Bands FCC & ISED PASS Receiver Radiated Emissions ISED PASS(2) This table is a summary of test report, see conclusion of each clause of this test report for detail. (1) Limited program (2) Testing covered the receive mode, and receiver spurious emissions are considered to be the same as transmitter. PASS: EUT complies with standard’s requirement FAIL: EUT does not comply with standard’s requirement NA: Not Applicable NP: Test Not Performed TEST REPORT N°32173710-823886-A(FILE#13683292) Version : 02 Page 5/53 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) 2.1. INFORMATION Energy Intelligence Control Unit Contains FCC ID ID QOQWFM200 and contains IC 5123A-WFM200 2.2. HARDWARE IDENTIFICATION (EUT AND AUXILIARIES): Equipment under test (EUT): Model under test: Energy Intelligence Control Unit Serial Number: EP142 TEST REPORT N°32173710-823886-A(FILE#13683292) Version : 02 Page 6/53 Dimensions: 6.3cm x 8.5cm x 7cm (Length x Width x Height) Type: Table-Top TEST REPORT N°32173710-823886-A(FILE#13683292) Version : 02 Page 7/53 Power supply: Name Type Rating Reference / Sn Comments Supply1 DC 5V I.T.E POWER SUPPLY MU05C2050100-A1 AC/DC Adapter NC: Not communicated by provider Inputs/outputs - Cable: Access Type Length used (m) Declared <3m Shielded Comments Supply1 USB-C 1 Yes No / …
Text truncated - open the document above for the full version.
Internal Energy Intelligence Control Unit Antennas simulation Confidential Property of Schneider Electric 26/06/26 Internal Page 2Confidential Property of Schneider Electric | WIFI 802.15.4 Internal Page 3Confidential Property of Schneider Electric | Reflection coefficient Wi-Fi 802.15.4 Internal Page 4Confidential Property of Schneider Electric | Radiation pattern Wi-Fi antenna Internal Page 5Confidential Property of Schneider Electric | Radiation pattern 802.15.4 antenna
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 1/3 CONDUCTED AND RADIATED MEASUREMENT PHOTO FCCID: 2BWOYSAH211111 1.1 Conducted emission LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 2/3 1.2 Radiated emissions LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 3/3
3700 6TH ST SW · Cedar Rapids, Iowa, 52404 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.36 mW |