
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Lamues Lighting Co.,LTD. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 [July 8, 2026] U.S. Agent Designation [Lamues Lighting Co.,LTD.] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2BWQJ-24401-001 Name and company of U.S. agent: [GLOCERTS TECHNOLOGY INC] Physical U.S. address of agent: [19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507] FRN of U.S. agent: [0036339737] Email address of U.S. agent: [[email protected]] Telephone of U.S.agent: (626) 588-8039 [GLOCERTS TECHNOLOGY INC] acknowledges their obligation to accept service of process on behalf of [Lamues Lighting Co.,LTD.]. [Lamues Lighting Co.,LTD.] with the FRN [0038576377] accepts its obligation to maintain an agent for service of process in the United States for no less than 1 year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Signature [Guo zhi qiang] [Huiying Fan] [Manager] [Director] [Lamues Lighting Co.,LTD.] [GLOCERTS TECHNOLOGY INC]
Lamues Lighting Co.,LTD. (July 6, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2BWQJ-24401-001 [Lamues Lighting Co.,LTD.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Guo zhi qiang Lamues Lighting Co.,LTD. (July 6, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2BWQJ-24401-001 [Lamues Lighting Co.,LTD.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Guo zhi qiang
Lamues Lighting Co.,LTD. (July 6, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Cordless LED Wall Sconce Set / 24401-001 / FCC ID: 2BWQJ-24401-001) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Guo zhi qiang Title: Manager
Lamues Lighting Co.,LTD. (July 6, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Guo zhi qiang Title: Manager
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: 24401-001 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4
FCC ID LABEL: Label Location: FCC ID: 2BWQJ-24401-001 Model No.: 24401-001
Shenzhen CTB Testing Technology Co., Ltd. FCC ID: 2BWQJ-24401-001 Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 434.015MHz: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion ASK 0.43402 -11.07 0.08 -11±1 -10.00 0.10 <5 0.01318 3.00 YES Note:dbm=dbuv/m-95.2-2.15=85.06-95.2-2.15=-12.29dBm(ERP), so the conduct peak power= -12.29-(-1.22)=-11.07dBm Conclusion: For the max result : 0.01318≤ FCC Limit 3.0 for 1g SAR.
1 / 7 目录/Catalogue 序号 No. 项目 Item 页码 Page No. 1 图纸或实物图片 Drawing or Product Image 3 2 技术参数 Technical Parameter 4 3 射频性能测试报告 RF Performance Test Report 5-8 Manufacturer: Lamues Lighting Co.,LTD. Address: NO.10 ZHENXING NORTH ROAD XIEGANG TOWN Dongguan, Guangdong. 2 / 7 一. 产品图纸或实物图片/Drawing or Product Image 3 / 7 二. Technical Parameter /技术参数 1. Antenna/天线 No/序号 Part Name/项目 SPEC/规格 1 Frequency Range/ 频率范围 433MHz 2 Impendence/阻抗 50 ohm nominal 3 Gain/增益 >-3dBi 4 Polarization/极化 LINE 5 VSWR/驻波比 ≤1.5 6 Efficiency/效率 ≥18% 2. Environmental Characteristics/环境特性 No/序号 Part Name/项目 SPEC/规格 1 Operation Humidity/ 工作湿度 5~95%不冷凝 2 Operating Temperature/ 工作温度 -20~+60°C 3 Store Temperatuer/ 储存温度 -30~+70°C 4 / 7 射频性能测量报告 RF Performance Test Report 天线测试设备简介 Antenna Test Equipment Introduction 测试天线输入特性使用Agilent E5071C and Agilent 5062A矢量网络分析仪;辐射特性利 用Satimo三维近场暗室进行测试,并分别使用8960 E5515和Agilent E4438C进行了分析。暗房 的测试坐标如下: Test of antenna input characteristics using Agilent E5071C and Agilent 5062A vector network analyzer; The radiation pattern of the antenna are tested using the Satimo starlab 3D near field Anechoic Chamber, and the instrument is used to agilent8960 E5515 and Agilent E4438C. The test coordinates of the darkroom are as follows: 1.S11参数测量/S11 Parameter-VSWR 使用一根50Ω同轴电缆连接到天线,然后该电缆连接到网络分析仪测量S11参数,被测量产品远 离金属至少20厘米。 Measuring Method is a 50Ωcoaxial cable is connected to the antenna. Then this cable is connected to a network analyzer to measure the S11 parameter, Keeping this fixture away from metal at least 20cm. 5 / 7 S11 Parameter 2D Pattern Phi =0 6 / 7 Phi =90 Theta =90 7 / 7 3. Gain & Efficiency-ANT
Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 24 TEST REPORT Compiled by: Reviewed by: Approved by: Kai Chen Martin Feng Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. The tested sample(s) and the sample information are provided by the applicant. The authenticity, accuracy, and completeness of the provided information are the sole responsibility of the applicant. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The result decision rules of our laboratory are based solely on the direct comparison between the actual measured values of test results and the standard limits, without considering the measurement uncertainty.“” indicates the testing items were fulfilled by subcontracted lab. “” indicates the items are not in CNAS accreditation scope. Test item description: Cordless LED Wall Sconce Set FCC ID: 2BWQJ-24401-001 Trademark(s): N/A Model/Type reference: 24401-001 Applicant’s name: Lamues Lighting Co.,LTD. Address: NO.10 ZHENXING NORTH ROAD XIEGANG TOWN Dongguan, Guangdong. Manufacturer: Lamues Lighting Co.,LTD. Address: NO.10 ZHENXING NORTH ROAD XIEGANG TOWN Dongguan, Guangdong. Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Jun. 17, 2026 Sample tested Date: Jun. 17, 2026 to Jun. 23, 2026 Issue Date: Jun. 23, 2026 Report No.: CTB26061703901RF01 Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.231 ANSI C63.10:2020 Test Results PASS Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26061703901RF01 Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 24 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 6 4.3 Support Equipment........................................................................................................................... 6 4.4 Test Mode ........................................................................................................................................ 6 4.5 Test Environment ............................................................................................................................. 6 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 7 5.1 Test Facility ...................................................................................................................................... 7 5.2 Test Instrument Used ....................................................................................................................... 7 6. AC POWER LINE CONDUCTED EMISSION .................................................................................. 9 6.1 Block Diagram Of Test Setup ........................................................................................................... 9 6.2 Limit .................................................................................................................................................. 9 6.3 Test procedure ................................................................................................................................. 9 6.4 Test Result ..................................................................................................................................... 10 7. RADIATED EMISSION ................................................................................................................. 11 7.1 Block Diagram Of Test Setup ......................................................................................................... 11 7.2 Limit ................................................................................................................................................ 11 7.3 Test procedure ............................................................................................................................... 12 7.4 Test Result ..................................................................................................................................... 13 8. DWELL TIME ................................................................................................................................ 19 8.1 Block Diagram Of Test Setup ......................................................................................................... 19 8.2 Limit ................................................................................................................................................ 19 8.3 Test procedure ............................................................................................................................... 19 8.4 Test Result ..................................................................................................................................... 20 9. OC…
Text truncated - open the document above for the full version.
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 1 Model: 24401-001 Radiated Emission Below 1G Above 1G
19784 SUNKISSED RIDGE DR, · RIVERSIDE,, California, 92507 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 434.015 MHz - 434.015 MHz | - |