Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Hong Kong Ticowill Co.,Limited Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 [July 3, 2026] U.S. Agent Designation [Hong Kong Ticowill Co.,Limited] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2BWWU-Q1 Name and company of U.S. agent: [GLOCERTS TECHNOLOGY INC] Physical U.S. address of agent: [19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507] FRN of U.S. agent: [0036339737] Email address of U.S. agent: [[email protected]] Telephone of U.S.agent: (626) 588-8039 [GLOCERTS TECHNOLOGY INC] acknowledges their obligation to accept service of process on behalf of [Hong Kong Ticowill Co.,Limited]. [Hong Kong Ticowill Co.,Limited] with the FRN [0038616785] accepts its obligation to maintain an agent for service of process in the United States for no less than 1 year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Signature [Holli Lee] [Huiying Fan] [Manager] [Director] [Hong Kong Ticowill Co.,Limited] [GLOCERTS TECHNOLOGY INC]
(Hong Kong Ticowill Co.,Limited) (July 2, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BWWU-Q1) [Hong Kong Ticowill Co.,Limited] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Holli Lee (Hong Kong Ticowill Co.,Limited) (July 2, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BWWU-Q1) [Hong Kong Ticowill Co.,Limited] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Holli Lee
Hong Kong Ticowill Co.,Limited Model Difference Data: July 2, 2026 Product description: car dash camera Model name: Q1, Q5, Q8, Q9 Trade Name: N/A FCC ID: 2BWWU-Q1 All the model are the same circuit and RF module, only the appearance is different. Regards Sincerely Client’s signature: Client’s name / title: Holli Lee (Manager) Contact information / address: Room L1, Unit 6, 13/F, Ming Fat Industrial Centre, 1 Kin Fat Street, Tuen Mun 999077 HK HK
Hong Kong Ticowill Co.,Limited (July 2, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen MinFan Electronic Commerce Co., LTD) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Holli Lee Title: Manager
Hong Kong Ticowill Co.,Limited (July 2, 2026) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (car dash camera / Q1, Q5, Q8, Q9 / FCC ID: 2BWWU-Q1) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Holli Lee Title: Manager
External Appendix FCC ID: 2BWWU-Q1 Model: Q1
Label Location: car dash camera Model: Q1 FCC ID: 2BWWU-Q1
Hong Kong Ticowill Co.,Limited FCC §15.247 (i), §2.1091 – RF Exposure FCC ID: 2BWWU-Q1 Applied procedures / limit According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength € (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Note: ƒ is frequency in MHz * = Power density limit is applicable at frequencies greater than 100 MHz Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength € (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz * = Plane-wave equivalent power density Hong Kong Ticowill Co.,Limited MPE PREDICTION Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna,R=20cm Test Result of RF Exposure Evaluation Mode Modes& Channe l Freq. (MHz) Tune up Produce power Maximu m peak output power (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm2) Limit (mW /cm2) Result 2.4G WIFI 802.11g &2412 15±1 16 39.8107 1.5311 (1.85dB) 0.01213 1 Pass
TEST REPORT Compiled by: Reviewed by: Approved by: Kai Chen Martin Feng Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. The tested sample(s) and the sample information are provided by the applicant. The authenticity, accuracy, and completeness of the provided information are the sole responsibility of the applicant. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The result decision rules of our laboratory are based solely on the direct comparison between the actual measured values of test results and the standard limits, without considering the measurement uncertainty.“” indicates the testing items were fulfilled by subcontracted lab. “” indicates the items are not in CNAS accreditation scope. Test item description: car dash camera FCC ID: 2BWWU-Q1 Trademark(s): N/A Model/Type reference: Q1, Q5, Q8, Q9 Applicant’s name: Hong Kong Ticowill Co.,Limited Address: Room L1, Unit 6, 13/F, Ming Fat Industrial Centre, 1 Kin Fat Street, Tuen Mun 999077 HK HK Manufacturer: Hong Kong Ticowill Co.,Limited Address: Room L1, Unit 6, 13/F, Ming Fat Industrial Centre, 1 Kin Fat Street, Tuen Mun 999077 HK HK Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Jun. 23, 2026 Sample tested Date: Jun. 23, 2026 to Jun. 27, 2026 Issue Date: Jun. 27, 2026 Report No.: CTB26062306601RF01 Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2020 Test Results PASS Remark: This is WIFI-2.4GHz band radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26062306601RF01 Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 49 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 6 4.3 Support Equipment........................................................................................................................... 6 4.4 Channel List ..................................................................................................................................... 6 4.5 Test Mode ........................................................................................................................................ 7 4.6 Test Environment ............................................................................................................................. 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 8 5.1 Test Facility ...................................................................................................................................... 8 5.2 Test Instrument Used ....................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION ................................................................................ 10 6.1 Block Diagram Of Test Setup ......................................................................................................... 10 6.2 Limit ................................................................................................................................................ 10 6.3 Test procedure ............................................................................................................................... 10 6.4 Test Result ..................................................................................................................................... 12 7. RADIATED SPURIOUS EMISSION ............................................................................................. 13 7.1 Block Diagram Of Test Setup ......................................................................................................... 13 7.2 Limit ................................................................................................................................................ 13 7.3 Test procedure ............................................................................................................................... 14 7.4 Test Result ..................................................................................................................................... 15 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............................................... 32 8.1 Block Diagram Of Test Setup ......................................................................................................... 32 8.2 Limit ................................................................................................................................................ 32 8.3 Test procedure ............................................................................................................................... 32 8.4 Test Result ....…
Text truncated - open the document above for the full version.
2.4GHz3216ChipAntenna:3216C03 _ Application: WLAN,802.11b/g,Bluetooth,WLAN,etc... Features SMD,highreliability,ultraImpact,Omni-directional... PartnumberInformation RANT3216F245C03 (A)(B)(C)(D)(E)(F) ElectricalSpecification ThespecificationisdefinedonEVB. DimensionandTerminalConfiguration No.TerminalName 1Feeding/GNG 2GND/Feeding (A)ProductTypeChipAntenna (B)SizeCode 3.2x1.6mm( ± 0.2mm) (C)MaterialHighKmaterial (D)Frequency2.4~2.5GHz (E)FeedingmodePIFA&SingleFeeding (F)AntennatypeType=0X WorkingFrequencyRange2400~2500MHz Bandwidth120MHz(Min.) PeakGain1.85dBi(Typ.) Impedance50Ohm Returnloss10dB(Min) PolarizationLinear AzimuthBeamwidthOmni-directional OperationTemperature(°C)-40~85°C ResistancetoSolderingHeats 10sec.(@280°C) TerminationNi/Au(Leadless) Dimension(mm) L 3.20±0.20 W 1.60±0.20 T 0.45±0.20 深圳市亿圣邦科技有限公司電話:18666299104 2.4GHz3216ChipAntenna:3216C03 _ 1 EvaluationBoardReference PCBDimensionAntennaLayoutReference Unit:mm ElectricalCharacteristics ReturnLoss&Radiation ReturnLoss Frequency(MHz) S11(dB) 2400-10.50 2450-30.62 2500-11.47 Radiation 2400MHz2450MHz2500MHz Efficiency82.52%85.26%83.01% X Y Z 2400MHz 2450MHz 2500MHz 2.4GHz3216ChipAntenna:3216C03 _ TapingSpecifications ReelandTapingSpecification ReelSpecification TYPESIZEABCD 32167”5K/Reel 9.0±0.5 60±213.5±0.5178±2 TappingSpecification PackagingTypeABWEFGHTψDP PaperType3216 1.90±0.203.50±0.208.0±0.201.75±0.103.5±0.054.0±0.102.0±0.050.75±0.10 1.50±0.10 4.0±0.1 2.4GHz3216ChipAntenna:3216C03 _ ReliabilityTable TestItemProcedure Requirements CeramicType Remark (Reference) Electrical Characterization Fulfilltheelectrical specification UserSpec. Thermal Shock 1.Preconditioning: 50±10°C/1hr,thenkeepfor24±1hrsatroomtemp. 2.Initialmeasure:Spec:referInitialspec. 3.Rapidchangeoftemperaturetest: -30°Cto+85°C;100cycles; 15minutesatLowercategorytemperature; 15minutesatUppercategorytemperature. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 107 Temperature Cycling 1.Initialmeasure:Spec:referInitialspec. 2.100Cycles(-30°Cto+85°C),SoakMode=1(2Cycle/hours). 3.Measurementat24±2Hoursaftertestcondition. NoVisibleDamage. Fulfilltheelectrical specification. JESD22 JA104 HighTemperature Exposure 1.Initialmeasure:Spec:referInitialspec. 2.Unpowered;500hours@T=+85°C. 3.Measurementat24±2hoursaftertest. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 108 LowTemperature Storage 1.Initialmeasure:Spec:referInitialspec. 2.Unpowered:500hours@T=-30°C. 3.Measurementat24±2hoursaftertest. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 108 Solderability (SMDBottomSide) Dippingmethod: a.Temperature:235±5°C b.Dippingtime:3±0.5s Thesoldershouldcover over95%ofthecritical areaofbottomside. IEC60384-21/22 4.10 SolderingHeat Resistance (RSH) Preheatingtemperature:150±10°C. Preheatingtime:1~2min. Soldertemperature:260±5°C. Dippingtime:5±0.5s NoVisibleDamage.IEC60384-21/22 4.10 Vibration5g'sfor20min.,12cycleseachof3orientations Note:Use8"X5"PCB.031"thick7securepointson,onelong sideand2securepointsatcornersofoppositesides.Parts mountedwithin2"fromanysecurepoint.Testfrom10-2000 Hz. NoVisibleDamage.MIL-STD-202 Method204 Mechanical Shock Threeshocksineachdirectionshallbeappliedalongthethree mutuallyperpendicularaxesofthetestspecimen(18shocks) Peakvalue:1,500g’s Duration:0.5ms Velocitychange:15.4ft/s Waveform:Half-sine NoVisibleDamage.MIL-STD-202 Method213 Humidity Bias 1.Humidity:85%R.H.,Temperature:85±2°C. 2.Time:500±24hours. 3.Measurementat24±2hrsaftertestcondition. NoVisibleDamage. Fulfilltheelectrical specification. MIL-STD-202 Method106 2.4GHz3216ChipAntenna:3216C03 _ Board Flex (SMD) 1.Mountingmethod: IR-Reflow.PCBSize(L:100×W:40×T:1.6mm) 2.Applytheloadindirectionofthearrowuntilbendingreaches 2mm. NoVisibleDamage.AEC-Q200 005 AdhesionForceof1.8Kgfor60seconds.NoVisibleDamage Magnificationof20Xor greatermaybeemployed forinspectionofthe mechanicalintegrityofthe devicebodyterminalsand body/terminaljunction. AEC-Q200 006 Physical Dimension Anyapplicablemethodusingx10magnification,micrometers, calipers,gauges,contourprojectors,orothermeasuring equipment,capableofdeterminingtheactualspecimen dimensions. Inaccordancewith specification. JESD22 JB100
Setup Appendix FCC ID: 2BWWU-Q1 Model: Q1
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 30.07 mW |