FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. zhongshanshixushengsuliaozhipinyouxiangongsi/
  3. 2BWYY-RM-01

2BWYY-RM-01Ceiling Fan Remote Control

zhongshanshixushengsuliaozhipinyouxiangongsi
Ceiling Fan Remote Control - FCC ID 2BWYY-RM-01 - zhongshanshixushengsuliaozhipinyouxiangongsi
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 03, 2026
Application Purpose
Original Equipment
Equipment Note
Ceiling Fan Remote Control
Frequency Range
2402.00000000 - 2402.00000000
Company
zhongshanshixushengsuliaozhipinyouxiangongsi
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Radiation Exposure Statement: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Attestation Statements

TCBCALLpágina1 FileFCCID:2BWYY-RM-01 PleaseuploadanexhibitthatexplainshowdoestheTCBverifythenewagentinformation: 1-IstheaddressoftheagentavalidphysicalUSmailingaddress(notaUSpostofficebox,notavirtualmailbox,notP.O.Boxes,notavacantlot,notapublicbuilding, etc.) ○Wehavecheckediftheaddressexistsinarealandpotentialbuilding(Googlemaps)+officialUSregister,afterthisverificationandtheevidencebelowwecan guaranteethefollowing: notaUSpostofficebox notavirtualmailbox notP.O.Boxes notavacantlot notapublicbuilding(note) ►WecheckedtheFCCFRNSearchbasedontheinformationprovidedbythegrantee. Ontheofficialregisterfrom: TCBCALLpágina2 Ingoogle: ►CONCLUSIONbyTCB:TheASOPdefinedandprovidedbygranteeisVALIDandconfirmed.Thereforetheexhibit" 2BWYY-RM-01USAgentforService ofProcessLETTEROFATTESTATION "includedinthefileisok. 2-IstheagentphysicallylocatedatthatvalidUSaddresssuchthattheagentcanbelegallyservedatthataddress? Yes,checkabove 3-Hasthelistedagentclearlyagreedinwritingtoserveastheagentforthegranteeatthataddress? Yes,itisincludedintheexhibit"2BWYY-RM-01USAgentforServiceofProcessLETTEROFATTESTATION " TCBCALLpágina3 >

Attestation Statements

1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: GLOBAL PRODUCT PROMOTION COMMERCE CO., LTD. Contact Name: David Kim Title: Manager FRN: 0037700671 Address: 350 NORTHERN BLVD STE 324-1331, ALBANY, NY, 12204, USA Telephone No: (213)849-1481 Email: [email protected] Applicant: Company name: zhongshanshixushengsuliaozhipinyouxiangongsi Product Description: Ceiling Fan Remote Control Grantee code: 2BWYY FCC ID: 2BWYY-RM-01 FRN: 0038634077 Contact Name: Li Rong Address: zhongshanshihenglanzhenchanganbeilu282haoDdong2louzhiyi Telephone No: +86 13380899988 Fax No: +86-0760-87687452 Email: [email protected] [zhongshanshixushengsuliaozhipinyouxiangongsi] certifies that, as of the date of this filing of the application with the TCB, [GLOBAL PRODUCT PROMOTION COMMERCE CO., LTD.]is our designated US agent for service of process for the above referenced FCC ID. [zhongshanshixushengsuliaozhipinyouxiangongsi] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [GLOBAL PRODUCT PROMOTION COMMERCE CO., LTD.]accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2026/08/26 Applicant’s Name: Li Rong US Agent’s Name: David Kim Title: General Manager Title: Manager Signature Signature 1/1

Attestation Statements

Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1 TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Telephone No: +86 13380899988 Fax No: +86-0760-87687452 Applicant Company name: zhongshanshixushengsuliaozhipinyouxiangongsi Grantee code: 2BWYY FCC ID: 2BWYY-RM-01 FRN: 0038634077 Contact Name:Li Rong Address: zhongshanshihenglanzhenchanganbeilu282haoDdong2louzhiyi Email: [email protected] i. [zhongshanshixushengsuliaozhipinyouxiangongsi] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [zhongshanshixushengsuliaozhipinyouxiangongsi] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [zhongshanshixushengsuliaozhipinyouxiangongsi] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 2026/07/13 Applicant’s Name: Li Rong Title: General Manager Signature The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

zhongshanshixushengsuliaozhipinyouxiangongsi Code 00018768 Ed. 1 Item 1. The device is able to install software/program installation? ☐ Yes, go to Item 2. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky cybersecurity or anti-virus software. Device Ceiling Fan Remote Control Company name zhongshanshixushengsuliaozhipinyouxiangongsi Grantee code 2BWYY FCC ID 2BWYY-RM-01 FRN 0038634077 Contact name Li Rong Address zhongshanshihenglanzhenchanganbeilu282haoDdong2louzhiyi Telephone number +86 13380899988 E-mail [email protected] Chipset/module information FL216C0 Operating System (if applicable) / Storage Capacity (hard drive or other permanent memory storage, if applicable) / 2 Item 2. Technical Requirements for Kaspersky Cybersecurity Software: # General Requirements (For all Devices) Yes / No or N/A Comments 1 Internet connection for activation and updates (For all Operating Systems) N/A # General Requirements (For Windows Devices) Yes / No or N/A Comments 1 Storage: 1500 MB free space on the hard drive N/A 2 Operating System: Microsoft Windows 8, 8.1, 10 & 11 Home / Pro / Enterprise Microsoft Windows 7 Starter / Home Basic & Premium / Professional / Ultimate SP1 or higher N/A 3 Processor: 1 GHz or higher (x86 or x64) N/A 4 Memory (RAM)1 GB (32-bit) or 2 GB (64-bit) N/A 5 Screen Resolution: Minimum resolution of 1024 x 768 N/A # General Requirements (For macOS devices) Yes / No or N/A Comments 1 Operating System macOS® 13 – 14 N/A 2 Memory (RAM)4 GB N/A 3 Storage: 3455 MB free space on the hard drive N/A # General Requirements (For Android Devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: Android™ 10 – 14 N/A 3 Screen Resolution: Minimum resolution of 320 x 480 N/A # General Requirements (for iOS devices) Yes / No or N/A Comments 3 1 Storage: 150 MB free space N/A 2 Operating System: iOS® 17 N/A # General Requirements (For Linux system) Yes / No or N/A Comments 1 Hard drive: 1 GB of free space N/A 2 CPU: Intel Pentium 1 GHz or higher 3 RAM: 1 GB 4 Minimum software requirements: AlmaLinux OS 8 or later; AlterOS 7.5 or later; Astra Linux Common Edition 2.12 or later; CentOS 6.7 or later; Debian GNU/Linux 10.0 or later; EulerOS 2.0 or later; Oracle Linux 7.3 or later ; Red Hat Enterprise Linux 6.7 or later ; Rocky Linux 8.5 or later ; SUSE Linux Enterprise Server 12.5 or later; Ubuntu 12.04 or later ; Uncom OS Home / Business / Education / Enterprise 2.2 or later; ALT Linux Workstaton / Workstation K / Server / Education 8 or later; ROSA Linux Workstation / Server 12 or later ; RED OS 7.3 and later ; 4 After reviewed the technical requirements, is the device capable of supporting the installation of Kaspersky software? ☐ Yes, go to Item 3. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky software Item 3. Connectivity Capabilities: # Physical Interface Purpose Justification 1 1 # Wireless Interface Purpose Justification 1 1 After the review of this items, the device: ☒ Cannot support installation of any cybersecurity or anti-virus software on the covered list. ☐ Potentially can operate with any cybersecurity or anti-virus software on the covered list – additional third- party proof is provided to demonstrate compliance with requirements as of 2.911(d)5(i),(ii) – “Proof of Compliance with Covered List Software Requirements” of this document applies Signature: Name: Li Rong Date: 2026.08.26 1 The justification field is used to justify why the software cannot be received through that interface. Check the annex for more indications.

Attestation Statements

zhongshanshixushengsuliaozhipinyouxiangongsi Product Similarity Declaration Product name: Ceiling Fan Remote Control Model name: RM-01, RM-02, RM-03, RM-04, RM-05, RM-06, RM-07, RM-08, RM-09, RM-10 FCC ID: 2BWYY-RM-01 Signature We (zhongshanshixushengsuliaozhipinyouxiangongsi) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only differences are the Model name and appearance colour. : Name: Li Rong Address: zhongshanshihenglanzhenchanganbeilu282haoDdong2louzhiyi

Cover Letter(s)

C5266091_X10_Ed.2 1/1 zhongshanshixushengsuliaozhipinyouxiangongsi Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2026-08-26 Subject: Request for Confidentiality FCC ID: 2BWYY-RM-01 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Li Rong Title: General Manager

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: zhongshanshixushengsuliaozhipinyouxiangongsi Address: zhongshanshihenglanzhenchanganbeilu282haoDdong2louzhiyi Product Name: Ceiling Fan Remote Control Model Number: RM-01, RM-02, RM-03, RM-04, RM-05, RM-06, RM-07, RM- 08, RM-09, RM-10 FCC Identifier: 2BWYY-RM-01 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Li Rong 2026-08-26 Title: General Manager Signature of applicant:

External Photos

Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of 3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Product Name: C e i l i n g F a n R e m o t e C o n t r o l Test Model No.: RM-01 EUT Constructional Details Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of 3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Shenzhen QC Testing Laboratory Co., Ltd. Page 3 of 3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn ------End------

Internal Photos

Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of 3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Product Name: C e i l i n g F a n R e m o t e C o n t r o l Test Model No.: RM-01 EUT Constructional Details Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of 3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Antenna Shenzhen QC Testing Laboratory Co., Ltd. Page 3 of 3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn ------End------

RF Exposure Info

Shenzhen QC Testing Laboratory Co., Ltd. FCC ID: 2BWYY-RM-01 1. Limit for Portable Equipment Exposure Frequency 1-g SAR 100MHz-6GHz 3.0 According to KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1093 For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz 2. Estimation Result Frequency (MHz) PK Output Power(dBm) Output Power(mW) Test Separation Distance (mm) Measurement Result 1-g SAR 2402 -3.6 0.437 5 0.135 3.0 Note: 1. use the maximum E-field strength(91.6dBuV/m) for the RF exposure evaluation 2. E(dBuV/m)=EIRP(dBm)-95.2 for distance 3m so the EIRP=91.6dBuV/m-95.2=-3.6dBm ------The End------

Test Report

Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26GR-1789E-01 Page 1 of 19 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn FCC PART 15.249 TEST REPORT On Behalf of zhongshanshixushengsuliaozhipinyouxiangongsi zhongshanshihenglanzhenchanganbeilu282haoDdong2louzhiyi FCC ID: 2BWYY-RM-01 Model: RM-01, RM-02, RM-03, RM-04, RM-05, RM-06, RM-07, RM-08, RM-09, RM-10 August 12, 2026 T hi s Repor t Concer ns: Or iginal Report Equi pm ent T ype: Ceiling Fan Rem ote Contr ol Test Engineer: Fan Yang / Report Number: QCT26GR-1789E-01 Test Date: July 15-20, 2026 Test Result: Pass Reviewed By: Vincent Yang / Approved By: Kendy Wang / Prepared By: Shenzhen QC Testing Laboratory Co., Ltd. East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26GR-1789E-01 Page 2 of 19 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Table of Contents 1. GENERAL INFORMATION ................................................................................................. 4 1.1 Product Description for Equipment under Test (EUT) ............................................................. 4 1.2 System Test Configuration ...................................................................................................... 4 1.3 Test Facility.............................................................................................................................. 5 1.4 Measurement Uncertainty ........................................................................................................ 5 2. SUMMARY OF TEST RESULTS ........................................................................................ 6 3. LIST OF TEST AND MEASUREMENT INSTRUMENTS .................................................... 7 3.1 Radiated Emission Test ........................................................................................................... 7 3.2 RF Conducted test ................................................................................................................... 7 4. ANTENNA REQUIREMENT ................................................................................................ 8 5. RADIATED EMISSION METHOD ....................................................................................... 9 5.1 Applicable Standard................................................................................................................. 9 5.2 Limit ......................................................................................................................................... 9 5.3 Receiver setup ......................................................................................................................... 9 5.4 Test setup ................................................................................................................................ 9 5.5 Test Procedure ...................................................................................................................... 10 5.6 Test Data ............................................................................................................................... 11 6. 20DB OCCUPY BANDWIDTH .......................................................................................... 18 6.1 Applicable Standard............................................................................................................... 18 6.2 Limit ....................................................................................................................................... 18 6.3 Test setup .............................................................................................................................. 18 6.4 Test Data ............................................................................................................................... 18 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26GR-1789E-01 Page 3 of 19 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Revision History of This Test Report Report Number Description Issued Date QCT26GR-1789E-01 Initial Issue 2026-08-12 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26GR-1789E-01 Page 4 of 19 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn 1. GENERAL INFORMATION 1.1 Product Description for Equipment under Test (EUT) EUT Description Ceiling Fan Remote Control Model No. RM-01, RM-02, RM-03, RM-04, RM-05, RM-06, RM-07, RM-08, RM-09, RM-10 Model Difference: All the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type and antenna location, components on PCB, etc.), same mechanical structure and design (including product enclosure, materials, etc.), the only differences in the Model name and appearance colour. Tested Model RM-01 Sample(s) Status Engineer sample Operation Frequency: 2402MHz Channel numbers: 1 Modulation type: GFSK Antenna Type: PCB Antenna Antenna gain 1 : -7.18dBi Power supply: 3V DC Trade Mark: fszdorj Applicant zhongshanshixushengsuliaozhipinyouxiangongsi Address zhongshanshihenglanzhenchanganbeilu282haoDdong2louzhiyi Manufacturer zhongshanshixushengsuliaozhipinyouxiangongsi Address zhongshanshihenglanzhen…

Text truncated - open the document above for the full version.

Test Report

AntennaSpecification ITEMANTSPEC ModelName 2.4GANT CenterFrequency 2402MHz OperatingFrequency 2400-2480MHz OCW N/A OperatingTemperature Range 125 °C Numberofchannels1 AntennaAssembly Type PCBantenna Gain Outputpower ≤3dBm ModulationType GFSK Adaptivity N/A Polarization LinearPolarization AzimuthBeamPatternDirectional Impedance 50Ohm AntennaSize 30.2006*13.335mm Manufacturer 中山市熠凡灯饰有限公司 ZhongShanYiFanLightingCo.,Ltd 地址中国广东省中山市古镇镇海洲教昌工业区创兴路28号 第 4 层之 1 Floor4-1,No.28ChuangxingRoad,JiaochangIndustrial Zone,Haizhou,GuzhenTown,ZhongshanCity,Guangdong Province,China -7.18 Test Results Gain Frequency (MHz) Gain(dBi) 2400-7.18 2410-8.19 2420-8.04 2430-8.66 2440-7.92 2450-8.44 2460-9.13 2470-8.73 2480-8.40 2490-8.95 2500-9.13 Annex A Test Setup Photos Antennasize

Test Setup Photos

Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Product Name: C e i l i n g F a n R e m o t e C o n t r o l Test Model No.: RM-01 Photograph of Test Setup Radiated Emissions (30 MHz - 1 GHz) Radiated Emissions (Above 1 GHz) Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn RF Conducted measurement

Contact Information

Applicant

Li Rong(General Manager)
[email protected]Fax: +86-0760-87687452

Technical Contact

GLOBAL PRODUCT PROMOTION COMMERCE CO., LTD.David Kim
[email protected]

350 NORTHERN BLVD STE 324-1331, ALBANY, NY, 12204, · ALBANY, New York, 12204 · United States

Test Firm

Shenzhen QC Testing Laboratory CO., Ltd.Kendy Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.40 GHz-
Confidentiality
Long Term