Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 1 of 3 Appendix External Photos for GZCR2604000787LM SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 2 of 3 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 3 of 3 - End of the Appendix -
FCC ID: 2BWZE-HS445 DC 5V 1A
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 1 of 3 Appendix Internal Photos for GZCR2604000787LM SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 2 of 3 EUT Constructional Details (EUT Photos) WPC Transmitter antenna SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 3 of 3 - End of the Appendix -
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078703 Page: 1 of 12 FCC ID: 2BWZE-HS445 TEST REPORT Application No.: GZCR2604000787LM Applicant:Smartek Inc. Address of Applicant:5534 Saint Joe Rd, Fort Wayne, IN 46835 Manufacturer:Smart Technology Co.,Ltd. Address of Manufacturer:No. 422 Haitian Avenue, Gaoming District, Foshan City, Guangdong Province, China Product Name:Lantern Model No.: HS445 Trade Mark:safety 1st Standard(s) : 47 CFR Part 1.1310 KDB 680106 D01 v04 KDB 447498 D01 General Radio Frequency Exposure Guidelines v06 Date of Receipt: 2026-04-24 Date of Test: 2026-05-13 Date of Issue: 2026-07-10 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078703 Page: 2 of 12 Revision Record VersionReport No.DateRemark 01GZCR2604000787032026-07-10Original Authorized for issue by: Luke Lin/Project Engineer Approved By Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078703 Page: 3 of 12 2Test Summary Radio Spectrum Matter Part ItemStandardMethodRequirementResult Field Strength KDB 680106 D01 v04 KDB 680106 D01 v04 47 CFR Part 1.1310 & KDB 680106 D01 Pass RF Exposure KDB 447498 D01 v06 KDB 447498 D01 v0647 CFR Part 1.1310 Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. N/A means Not applicable, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078703 Page: 4 of 12 3Contents Page 1Cover Page.................................................................................................................................................1 2Test Summary............................................................................................................................................3 3Contents.....................................................................................................................................................4 4General Information...................................................................................................................................5 4.1Details of E.U.T...................................................................................................................................5 4.2Description of Support Units................................................................................................................5 4.3Measurement Uncertainty...................................................................................................................5 4.4Test Location.......................................................................................................................................5 4.5Test Facility.........................................................................................................................................6 4.6Deviation from Standards....................................................................................................................6 4.7Abnormalities from Standard Conditions.............................................................................................6 5Equipment List...........................................................................................................................................7 6Radio Spectrum Matter Test Results.......................................................................................................8 6.1Magnetic field strength........................................................................................................................8 6.1.1E.U.T. Operation.............................................................................................................................8 6.1.2Test Mode Description....................................................................................................................9 6.1.3Test Setup Diagram........................................................................................................................9 6.1.4Measurement Procedure and Data..............................................................................................10 7Test Setup Photo.....................................................................................................................................11 8EUT Constructional Details (EUT Photos).............................................................................................12 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078703 Page: 5 of 12 4General Information 4.1Details of E.U.T. Power supply:For wireless pad: DC 5V For light (wireless charging receiver only): DC 5V for charge mode. Built in lithium battery size 18650 3.7v *1pcs Cable(s):Type-C port for power supply Test Voltage:AC 120 V, 60 Hz RF character:Refer to report GZCR260400078702 for WPC detail. Remark: The information in this section is provided by the applicant or manufacturer, SGS is not liable to the accuracy, suitability, reliability or/and integrity of the information. 4.2Description of Support Units DescriptionManufacturerModel No.Serial No. AC/DC AdapterHUAWEI Model: HW-110600C02; Input: AC 100-240V,1.8A Max.50/60Hz; Output: DC 5V/2A, 10V/4A, 11V/6A Max. JL28L4NBM03275 4.3Measurement Uncertainty Test ItemMeasurement Uncertainty Field strengthH tot : U=2.65dB, E tot : U=1.89dB Remark: The U lab (lab Uncertainty) is less than U cispr (CISPR Uncertainty) or U ETSI (ETSI Uncertainty). Emission decision rule: โ Compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit, marked as Pass โฆ
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078702 Page: 1 of 31 FCC ID: 2BWZE-HS445 TEST REPORT Application No.: GZCR2604000787LM Applicant:Smartek Inc. Address of Applicant:5534 Saint Joe Rd, Fort Wayne, IN 46835 Manufacturer:Smart Technology Co.,Ltd. Address of Manufacturer:No. 422 Haitian Avenue, Gaoming District, Foshan City, Guangdong Province, China Product Name:Lantern Model No.: HS445 Trade Mark:safety 1st Standard(s) : 47 CFR Part 15, Subpart C Date of Receipt: 2026-04-24 Date of Test: 2026-05-06 to 2026-07-06 Date of Issue: 2026-07-10 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078702 Page: 2 of 31 Revision Record VersionReport No.DateRemark 01GZCR2604000787022026-07-10Original Authorized for issue by: Luke Lin/Project Engineer Approved By Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078702 Page: 3 of 31 2Test Summary Radio Spectrum Technical Requirement ItemStandardMethodRequirementResult Antenna Requirement 47 CFR Part 15, Subpart C N/A 47 CFR Part 15, Subpart C 15.203 Pass Radio Spectrum Matter Part ItemStandardMethodRequirementResult 20dB Bandwidth ANSI C63.10 (2020) Section 6.9.2 47 CFR Part 15, Subpart C 15.215 Pass Conducted Emissions at AC Mains Power Port (150kHz-30MHz) ANSI C63.10 (2020) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass** Restricted Bands ANSI C63.10 (2020) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 Pass Radiated Emissions (9kHz-30MHz) ANSI C63.10 (2020) Section 6.4 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Emissions (30MHz-1GHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2020) Section 6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass** **: The EUT passed Conducted Emissions at Mains Terminals (150kHz-30MHz), Radiated Emissions (30MHz-1GHz) tests after modification. Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. N/A means Not applicable, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 2.1 Report No.:GZCR260400078702 Page: 4 of 31 3Contents Page 1Cover Page.................................................................................................................................................1 2Test Summary............................................................................................................................................3 3Contents.....................................................................................................................................................4 4General Information...................................................................................................................................6 4.1Details of E.U.T...................................................................................................................................6 4.2Description of Support Units................................................................................................................6 4.3Measurement Uncertainty...................................................................................................................7 4.4Test Location.......................................................................................................................................7 4.5Test Facility.........................................................................................................................................8 4.6Deviation from Standards....................................................................................................................8 4.7Abnormalities from Standard Conditions.............................................................................................8 5Equipment List...........................................................................................................................................9 6Radio Spectrum Technical Requirement...............................................................................................11 6.1Antenna Requirement.......................................................................................................................11 6.1.1Test Requirement:........................................................................................................................11 6.1.2Conclusion....................................................................................................................................11 7Radio Spectrum Matter Test Results.....................................................................................................12 7.120dB Bandwidth................................................................................................................................12 7.1.1E.U.T. Operation...........................................................................................................................12 7.1.2Test Mode Description..................................................................................................................12 7.1.3Test Setup Diagram......................................................................................................................12 7.1.4Measurement Procedure and Data..............................................................................................13 7.2Conducted Emissions at AC Mains Power Port (150kHz-30MHz)....................................................14 7.2.1E.U.T. Operation...........................................................................................................................14 7.2.2Test Mode Description...โฆ
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 1 of 4 Appendix Test Setup Photo for GZCR260400078702 Test Model No.: HS445 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 2 of 4 Test Setup Photo Conducted Emissions at Mains Terminals (150kHz-30MHz) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 3 of 4 Radiated Emissions (9kHz-30MHz) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 4 of 4 Radiated Emissions (30MHz-1GHz) - End of the Appendix -
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 1 of 4 Appendix Test Setup Photo for GZCR260400078703 Test Model No.: HS445 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 2 of 4 Test Setup Photo Side 1 Side 2 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 3 of 4 Side 3 Side 4 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 4 of 4 Bottom Side Top Side - End of the Appendix -
5534 Saint Joe Road Fort Wayne ยท Fort Wayne, Indiana, 46835 ยท United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1132 MHz - 0.158896 MHz | - |