Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SuzhouYuqiuIndustrialTechnologyCo.,Ltd. Address:Room504,505,Building2,TaishanRoad689,Hi-TechZone,SuzhouCity,China Date:2026-08-05 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BXDP-GV012 FRN:0038706792 (“SuzhouYuqiuIndustrialTechnologyCo.,Ltd.”)certifiesthat,asofthedateofthefilingofthe application,GOLDENVICTORYINTERNATIONALTRADINGCOLTDisourdesignatedU.S. agentforserviceofprocessfortheabovereferencedFCCID.(“SuzhouYuqiuIndustrial TechnologyCo.,Ltd.”)acceptstomaintainanagentfornolessthanoneyearafterthe granteehasterminatedallmarketingandimportationortheconclusionofanyCommission- relatedproceedinginvolvingtheequipment. GOLDENVICTORYINTERNATIONALTRADINGCOLTDaccepts,asofthedateofthefiling oftheapplication,theobligationofthedesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID. DesignatedU.S.AgentInformation: Name:GOLDENVICTORYINTERNATIONALTRADINGCOLTD Address:11016THSTREETSUITE1400DENVER,CO80202UnitedStates FRN:0036377570 ContactPerson:LeonHowar Tel.:(337)255-0461 Email:[email protected] Sincerely, Signedonbehalfof(SuzhouYuqiu IndustrialTechnologyCo.,Ltd.) SignedonbehalfofGOLDENVICTORY INTERNATIONALTRADINGCOLTD Name:DONGLYUName:LeonHowar Title:ManagerTitle:Manager Date:2026-08-05Date:2026-08-05
Rev1/26/2023 (SuzhouYuqiuIndustrialTechnologyCo.,Ltd.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-08-05 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BXDP-GV012 (“SuzhouYuqiuIndustrialTechnologyCo.,Ltd.”)certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. (“SuzhouYuqiuIndustrialTechnologyCo.,Ltd.”)certifiesthattheequipmentforwhichauthorizationis soughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc. oranyofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyof itssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB 986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):DONGLYU Rev1/26/2023 (SuzhouYuqiuIndustrialTechnologyCo.,Ltd.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-08-05 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BXDP-GV012 (“SuzhouYuqiuIndustrialTechnologyCo.,Ltd.”)certifiesthat,asofthedateofthefilingofthe application,SuzhouYuqiuIndustrialTechnologyCo.,Ltd.isnotidentifiedontheCoveredList(asa specificallynamedentityoranyofitssubsidiariesoraffiliates)asanentityproducing“covered” equipment. Sincerely, (Applicantsignature): (Applicantprintedname):DONGLYU
SuzhouYuqiuIndustrialTechnologyCo.,Ltd. Date:August5,2026 ProductModelNumber:GV012 FCCID:2BXDP-GV012 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:+8613906135168 Onbehalfof:SuzhouYuqiuIndustrialTechnologyCo.,Ltd.
SuzhouYuqiuIndustrialTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:August5,2026 Subject;RequestforConfidentiality FCCID:2BXDP-GV012 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:DONGLYU Title:Manager
SuzhouYuqiuIndustrialTechnologyCo.,Ltd. ModelDifference Date:2026-08-05 Productdescription:remotekey Modelname:GV012 FCCID:2BXDP-GV012 Themodelhasmultipleappearance.theseproductaresamePCBLayout,Schematics, BOM.Onlyfordifferentappearancepatternsfordifferentmarketrequire. Client’ssignature: Client’sname/title:DONGLYU/Manager Contactinformation/address:Room504,505,Building2,TaishanRoad689,Hi-Tech Zone,SuzhouCity,China
FCCID:2BXDP-GV012 EUTPHOTOS(ExternalPhotos) FCCID:2BXDP-GV012 FCCID:2BXDP-GV012 FCCID:2BXDP-GV012 ※※※※※ENDOFREPORT※※※※※
FCCID:2BXDP-GV012 RFExposureEvaluation Per § 1.1307(b)(3)(i)(A),asingleRFsourceisexemptRFdevice(fromtherequirementto showdatademonstratingcompliancetoRFexposurelimits,aspreviouslymentioned)ifthe availablemaximumtime-averagedpowerisnomorethan1mW,regardlessofseparation distance.Thisexemptionappliestoalloperatingconfigurationsandexposureconditions, forthefrequencyrange100kHzto100GHz,regardlessoffixed,mobile,orportabledevice exposureconditions.Thisisastandaloneexemption,anditcannotbeappliedin conjunctionwithanyothertestexemption. TestResultofRFExposureEvaluation Mode Outputpowerto antenna(dBm) Outputpowerto antenna(mW) Limit (mW) SRD-17.010.021 Remark:FieldStrength:78.19dBuV/m@3m EIRP=78.19-95.2=-17.01dBm SoaSARtestisnotrequired
ProjectNo.:ZHT-260722122W01 Page 1 of 26 FCCTESTREPORT FCCID:2BXDP-GV012 ApplicantName...............:SuzhouYuqiuIndustrialTechnologyCo.,Ltd. Address............................:Room504,505,Building2,TaishanRoad689,Hi-TechZone,Suzhou City,China ManufacturerName.........:SuzhouYuqiuIndustrialTechnologyCo.,Ltd. Address............................:Room504,505,Building2,TaishanRoad689,Hi-TechZone,Suzhou City,China Product............................:remotekey Model(s)...........................:GV012 AdditionalModel(s)..........:/ Trademark.......................:/ ModelDifference..............:/ Preparedby.....................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:July22,2026 DateofTest(s).................:July22,2026toAug.17,2026 DateofIssue....................:Aug.17,2026 TestRequested................:Selecttest(s)asrequestedbytheclient. TestStandard(s)..............:FCCCFRTitle47Part15SubpartCSection15.231 ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+ErratatoC63.10a-2024 Testprocedure................:/ Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Testedby:Reviewedby:Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:Theresultsshowninthistestreportreferonlytothesample(s)testedunlessotherwisestated.Thistest reportshallnotbereproducedexceptinfull,withoutpriorwrittenapprovalofZHT.Thisdocumentmaybe alteredorrevisedbyZHT,personnelonly,andshallbenotedintherevisionofthedocument. ProjectNo.:ZHT-260722122W01 Page 2 of 26 TableofContents Page 1.SUMMARYOFTESTRESULTS.............................................................................................................3 2.GENERALINFORMATION.....................................................................................................................4 2.1GENERALDESCRIPTIONOFEUT...............................................................................................4 2.2DESCRIPTIONOFTESTMODES..................................................................................................5 2.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............................5 2.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)......................................................5 3.MTESTFACILITYANDTESTINSTRUMENTUSED.............................................................................6 3.1TESTFACILITY...............................................................................................................................6 3.2INSTRUMENTLISTFORALLTESTITEMS..................................................................................6 3.3TESTINGSOFTWARE....................................................................................................................7 3.4MEASUREMENTUNCERTAINTY..................................................................................................8 4.EMCEMISSIONTEST............................................................................................................................9 4.1CONDUCTEDEMISSIONMEASUREMENT..................................................................................9 4.2RADIATEDEMISSIONMEASUREMENT.....................................................................................11 5.BANDWIDTHTEST...............................................................................................................................18 5.1APPLIEDPROCEDURES/LIMIT.................................................................................................18 5.2TESTPROCEDURE......................................................................................................................18 5.3DEVIATIONFROMSTANDARD...................................................................................................18 5.4TESTSETUP.................................................................................................................................18 5.5EUTOPERATIONCONDITIONS..................................................................................................18 5.6TESTRESULTS............................................................................................................................19 6.CALCULATIONOFAVERAGEFACTOR.............................................................................................20 7.TRANSMITTIME...................................................................................................................................23 7.1APPLICABLESTANDARD...........................................................................................................23 7.2TESTPROCEDURE......................................................................................................................23 7.3DEVIATIONFROMSTANDARD...................................................................................................23 7.5EUTOPERATIONCONDITIONS..................................................................................................23 7.6TESTRESULTS............................................................................................................................24 8.ANTENNAREQUIREMENT..................................................................................................................25 9.TESTSETUPPHOTO...........................................................................................................................26 10.EUTCONSTRUCTIONALDETAILS...................................................................................................26 ProjectNo.:ZHT-260722122W01 Page 3 of 26 1.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15(15.231),SubpartC Standard Section TestItemJudgmentRemark 15.207ConductedEmissionN/A 15.209,15.231b Fundamental&RadiatedSpuriousEmission Measurement PASS 15.231cOccupyBandwidthPASS 15.231aTransmitTimePASS 15.…
Text truncated - open the document above for the full version.
AntennaSpecification Name:PCBantenna Frequency:315MHz V.S.W.R:1.5 AntennaType:PCBantenna Gain(dBi):0dBi Manufacturer: SuzhouYuqiuIndustrialTechnologyCo.,Ltd. Room504,505,Building2,TaishanRoad689, Hi-TechZone,SuzhouCity,China size:
FCCID:2BXDP-GV012 EUTTESTPHOTOS ※※※※※ENDOFREPORT※※※※※
110 16TH STREET SUITE 1400 DENVER, · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |