2BXFC-AD-KC002Smart Wall Switch Socket

Shenzhen Aodu Technology Co.,Ltd
Smart Wall Switch Socket - FCC ID 2BXFC-AD-KC002 - Shenzhen Aodu Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 21, 2026
Application Purpose
Original Equipment
Equipment Note
Smart Wall Switch Socket
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Aodu Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Blue FCC Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. RF Exposure Statement To maintain compliance with FCC'S RF Exposure guidelines, This equipment should be installed and operated with minimum 20cm between the radiator and your body. This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter.

Attestation Statements

Rev 1/26/2023 Shenzhen Aodu Technology Co.,Ltd Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 08-17-2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BXFC-AD-KC002 [Shenzhen Aodu Technology Co.,Ltd] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Shenzhen Aodu Technology Co.,Ltd] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name) Lemon feng Rev 1/26/2023 Shenzhen Aodu Technology Co.,Ltd Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 08-17-2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BXFC-AD-KC002 [Shenzhen Aodu Technology Co.,Ltd] ce8rtifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Lemon feng

Attestation Statements

Shenzhen Aodu Technology Co.,Ltd U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: August 17, 2026 Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BXFC-AD-KC002 Shenzhen Aodu Technology Co.,Ltd (“the applicant”) certifies that, as of the date of the filing of the application, CLF Import and Export Limited (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. CLF Import and Export Limited ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: CLF Import and Export Limited FRN: 0033489683 Address: 1312 17th Street #692, Denver, CO 80202, United States Signature: Contact Person: David Chen Tel: +1 949 254 2565 Email: [email protected] Applicant Company Name: Shenzhen Aodu Technology Co.,Ltd FRN: 0038711818 Address: Room 401, Building D, Weihuada Industrial Park, No. 5 Lirong Road, Dalang Street, Longhua District, Shenzhen City, Guangdong Province, China Signature: Contact Person: Lemon feng Tel: +86-18211307641 Email: [email protected]

Cover Letter(s)

Shenzhen Aodu Technology Co.,Ltd Date: August 17, 2026 Product Model Number: AD-KC002, AD-KC001, AD-KC003, AD-KC004, AD-KC005, AD-KC001B, AD-KC002B, AD-KC003B, AD-KC004B, AD- KC005B FCC ID: 2BXFC-AD-KC002 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following:  Testing  Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Lemon feng Contact Listed on FCC Wesbite Title: Manager Email: [email protected] Telephone: +86-18211307641 On behalf of: Shenzhen Aodu Technology Co.,Ltd

Cover Letter(s)

Shenzhen Aodu Technology Co.,Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 17, 2026 Subject; Request for Confidentiality FCC ID: 2BXFC-AD-KC002 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Lemon feng Title: Manager

Cover Letter(s)

Shenzhen Aodu Technology Co.,Ltd Model Difference Statement DATE: August 17, 2026 FCC ID: 2BXFC-AD-KC002 Dear Sir/Madam, Added models AD-KC001, AD-KC003, AD-KC004, AD-KC005, AD-KC001B, AD-KC002B, AD-KC003B, AD-KC004B, AD-KC005B asis of the original product AD-KC002. The color of appearance and model name of series models listed are different from the main model, but the circuit and the electronic construction are the same, declared by the manufacturer. Sincerely, Name: Lemon feng Title: Manager Company name: Shenzhen Aodu Technology Co.,Ltd Address: Room 401, Building D, Weihuada Industrial Park, No. 5 Lirong Road, Dalang Street, Longhua District, Shenzhen City, Guangdong Province, China

External Photos

Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report Annex A. EUT External Photos EUT View 1 EUT View 2 Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report EUT View 3 EUT View 4 Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report EUT View 5 EUT View 6 Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report EUT View 7 EUT View 8

ID Label/Location Info

Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report Annex D. Label and Inf ormation FCC Label Sample FCC Labe Size: 32mm *10mm FCC Label Specifications Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Where the EUT is constructed in two or more sections connected by wires and marketed together, the above statement is required to be affixed only to the main control unit. When the EUT is so small or for such use that it is not practicable to place the statement on it, the above information shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. FCC Label Location Label Location

Internal Photos

Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report Annex B. EUT Internal Photos EUT Internal View 1 EUT Internal View 2 Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report EUT Internal View 3 EUT Internal View 4 PCB ANT Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report EUT Internal View 5 EUT Internal View 6 Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report EUT Internal View 7

RF Exposure Info

FCC ID: 2BXFC-AD-KC002 RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz, * = Plane-wave equivalent power density. Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation For 2.4GWiFi Mode Output power to antenna (dBm) Tune-up Power(dBm) Max Tune-up Power(dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm2) Limit (mW/cm2) Result 802.11b 16.08 16(±1) 17 50.12 0.0305 1.0 PASS Remark: antenna gain= 4.85dBi

Test Report

Report No: SSP26070497-1 FCC Test Report Page 1 of 50 FCC TEST REPORT FCC ID: 2BXFC-AD-KC002 Report No. : SSP26070497-1 Applicant : Shenzhen Aodu Technology Co.,Ltd Product Name : Smart Wall Switch Socket Model Name : AD-KC002 Test Standard : FCC Part 15.247 Date of Issue : 2026-08-17 Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China; (Tel.:+86-755-23406590 website: www.zrlklab.com) This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd. Report No: SSP26070497-1 FCC Test Report Page 2 of 50 Test Report Basic Information Applicant..................................: Shenzhen Aodu Technology Co.,Ltd Address of Applicant...............: Room 401, Building D, Weihuada Industrial Park, No. 5 Lirong Road, Dalang Street, Longhua District, Shenzhen City, Guangdong Province, China Manufacturer..........................: Shenzhen Aodu Technology Co.,Ltd Address of Manufacturer........: Room 401, Building D, Weihuada Industrial Park, No. 5 Lirong Road, Dalang Street, Longhua District, Shenzhen City, Guangdong Province, China Product Name.........................: Smart Wall Switch Socket Brand Name.............................: - Main Model..............................: AD-KC002 Series Models..........................: AD-KC001, AD-KC003, AD-KC004, AD-KC005, AD-KC001B, AD-KC002B, AD-KC003B, AD-KC004B, AD-KC005B Test Standard..........................: FCC Part 15 Subpart C KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.4-2014 ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 Date of Test .............................: 2026-07-25 to 2026-07-28 Test Result...............................: PASS Tested By ................................: (Walker Wu) Reviewed By............................: (Lorzix Luo) Authorized Signatory............: (Lahm Peng) Note : This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd.. All test data presented in this test report is only applicable to presented test sample. Report No: SSP26070497-1 FCC Test Report Page 3 of 50 CONTENTS 1. General Information ....................................................................................................................................................5 1.1 Product Information .............................................................................................................................................5 1.2 Test Setup Information..........................................................................................................................................6 1.3 Compliance Standards ...........................................................................................................................................7 1.4 Test Facilities ........................................................................................................................................................7 1.5 List of Measurement Instruments ..........................................................................................................................8 1.6 Measurement Uncertainty .....................................................................................................................................9 2. Summary of Test Results ........................................................................................................................................... 10 3. Antenna Requirement ............................................................................................................................................... 11 3.1 Standard and Limit.............................................................................................................................................. 11 3.2 Test Result .......................................................................................................................................................... 11 4. Conducted Emissions ................................................................................................................................................ 12 4.1 Standard and Limit.............................................................................................................................................. 12 4.2 Test Procedure.................................................................................................................................................... 12 4.3 Test Data and Results .......................................................................................................................................... 13 5. Radiated Emissions ................................................................................................................................................... 16 5.1 Standard and Limit.............................................................................................................................................. 16 5.2 Test Procedure.................................................................................................................................................... 16 5.3 Test Data and Results .......................................................................................................................................... 18 6. Band-edge Emissions(Radiated) ............................................................................................................................... 22 6.1 Standard and Limit.............................................................................................................................................. 22 6.2 Test Procedure....................................................................................…

Text truncated - open the document above for the full version.

Test Report

Antenna Datasheet AD-KC002 Type of Antenna:PCB Antenna Manufacturer: Shenzhen Aodu Technology Co.,Ltd Address: Room 401, Building D, Weihuada Industrial Park, No. 5 Lirong Road, Dalang Street, Longhua District, Shenzhen City, Guangdong Province, China Antenna Test Environment www.mesoonrf.cnPage 1 Antenna Outline Drawing www.mesoonrf.cnPage 2 Antenna Anechoic Chamber Test Data www.mesoonrf.cnPage 3 www.mesoonrf.cnPage 4 www.mesoonrf.cnPage 5 www.mesoonrf.cnPage 6 www.mesoonrf.cnPage 7 www.mesoonrf.cnPage 8 Shenzhen MesoonRF loT Technology.co.,Ltd 3/F, No. 10 Xinggong 1st Road, Xinggong Community, Yutang Subdistrict, Guangming District, Shenzhen, China Tel.+860755-23764945

Test Setup Photos

Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report Annex C. Test Photos Conducted Emission Test View 1 Radiated Emission Test View Below 1GHz Report No: SSP26070497-1 FCC ID: 2BXFC-AD-KC002 Annex of Test Report Radiated Emission Test View Above 1GHz

Contact Information

Applicant

Lemon. feng
[email protected]Fax: +86-18211307641

Technical Contact

CLF Import and Export LimitedDavid Chen
[email protected]

1312 17th Street #692, · United States

Test Firm

Shenzhen CCUT Quality Technology Co., Ltd.Lahm Peng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz40.60 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.