2BXIC-ZJ-LWBDLA1WBCandle Warmer Lamp

JM Zengge Lighting Co., LTD
Candle Warmer Lamp - FCC ID 2BXIC-ZJ-LWBDLA1WB - JM Zengge Lighting Co., LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 12, 2026
Application Purpose
Original Equipment
Equipment Note
Candle Warmer Lamp
Frequency Range
2402.00000000 - 2480.00000000
Company
JM Zengge Lighting Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user's authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antenna(s). 7 Candle Warmer Lamp

Attestation Statements

JMZenggeLightingCo.,LTD Address:Unit601,6thFloor,Building2,No.7DongshengRoad,JianghaiDistrict,Jiangmen City,GuangdongProvince,China Date:2026-08-07 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BXIC-ZJ-LWBDLA1WB FRN:0038734893 (“JMZenggeLightingCo.,LTD”)certifiesthat,asofthedateofthefilingoftheapplication, GOLDENVICTORYINTERNATIONALTRADINGCOLTDisourdesignatedU.S.agentfor serviceofprocessfortheabovereferencedFCCID.(“JMZenggeLightingCo.,LTD”)accepts tomaintainanagentfornolessthanoneyearafterthegranteehasterminatedallmarketing andimportationortheconclusionofanyCommission-relatedproceedinginvolvingthe equipment. GOLDENVICTORYINTERNATIONALTRADINGCOLTDaccepts,asofthedateofthefiling oftheapplication,theobligationofthedesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID. DesignatedU.S.AgentInformation: Name:GOLDENVICTORYINTERNATIONALTRADINGCOLTD Address:11016THSTREETSUITE1400DENVER,CO80202UnitedStates FRN:0036377570 ContactPerson:LeonHowar Tel.:(337)255-0461 Email:[email protected] Sincerely, Signedonbehalfof(JMZenggeLighting Co.,LTD) SignedonbehalfofGOLDENVICTORY INTERNATIONALTRADINGCOLTD Name:BriturnLinName:LeonHowar Title:ManagerTitle:Manager Date:2026-08-07Date:2026-08-07

Attestation Statements

Rev1/26/2023 (JMZenggeLightingCo.,LTD) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:8-7-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BXIC-ZJ-LWBDLA1WB (“JMZenggeLightingCo.,LTD”)certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903of theFCCrules. (“JMZenggeLightingCo.,LTD”)certifiesthattheequipmentforwhichauthorizationissoughtdoesnot includecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofits successorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):BriturnLin Rev1/26/2023 (JMZenggeLightingCo.,LTD) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:8-7-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BXIC-ZJ-LWBDLA1WB (“JMZenggeLightingCo.,LTD”)certifiesthat,asofthedateofthefilingoftheapplication,JMZengge LightingCo.,LTDisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature): (Applicantprintedname):BriturnLin

Cover Letter(s)

JMZenggeLightingCo.,LTD Date:August7,2026 ProductModelNumber:ZJ-LWBDLA1WB-WUS-4K-BT, ZJ-LWBDLA2WW-WUS-4K-BT,ZJ-LWBDLA3WC-WUS-4K-BT, ZJ-LWBDLA4WC-WUS-4K-BT,ZJ-LWBDLA5WS-WUS-4K-BT, ZJ-LWBDLC1WB-WUS-4K-BT,ZJ-LWBDLC2WW-WUS-4K-BT, ZJ-LWBDLC3WC-WUS-4K-BT,ZJ-LWBDLC4WS-WUS-4K-BT, ZJ-LWBDLC5WY-WUS-4K-BT,ZJ-LWBDLD2WW-WUS-4K-BT, ZJ-LWBDLD1WB-WUS-4K-BT,ZJ-LWBDLB2WW-WUS-4K-BT, ZJ-LWBDLB1WB-WUS-4K-BT,ZJ-LWBDLE2WW-WUS-4K-BT, ZJ-LWBDLE1WB-WUS-4K-BT,ZJ-RLTD-PBFHH-D1US2S, ZJ-RLTD-PBFLST-D1US2S,ZJ-RLTD-PBSSJ-D1US2S, ZJ-RLTD-PBPSY-D1US2S,ZJ-RLTD-PBPSB-D1US2S, ZJ-RLTD-DBHSH-D1US2S,ZJ-RLTD-DBHLST-D1US2S, ZJ-RLTD-DBHSJ-D1US2S,ZJ-RLTD-DBHSY-D1US2S, ZJ-RLTD-DBHSB-D1US2S,ZJ-RLTD-PTBH-D1US2S, ZJ-RLTD-PTBH-D1JP2S,ZJ-RLTD-PTBH-D2AP2S FCCID:2BXIC-ZJ-LWBDLA1WB Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: ď‚·Testing ď‚·Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:15875583798 Onbehalfof:JMZenggeLightingCo.,LTD

Cover Letter(s)

JMZenggeLightingCo.,LTD OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:August7,2026 Subject;RequestforConfidentiality FCCID:2BXIC-ZJ-LWBDLA1WB ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:BriturnLin Title:Manager

Cover Letter(s)

JMZenggeLightingCo.,LTD ModelDifference Date:2026-08-10 Productdescription:CandleWarmerLamp Modelname:ZJ-LWBDLA1WB-WUS-4K-BT,ZJ-LWBDLA2WW-WUS-4K-BT, ZJ-LWBDLA3WC-WUS-4K-BT,ZJ-LWBDLA4WC-WUS-4K-BT, ZJ-LWBDLA5WS-WUS-4K-BT,ZJ-LWBDLC1WB-WUS-4K-BT, ZJ-LWBDLC2WW-WUS-4K-BT,ZJ-LWBDLC3WC-WUS-4K-BT, ZJ-LWBDLC4WS-WUS-4K-BT,ZJ-LWBDLC5WY-WUS-4K-BT, ZJ-LWBDLD2WW-WUS-4K-BT,ZJ-LWBDLD1WB-WUS-4K-BT, ZJ-LWBDLB2WW-WUS-4K-BT,ZJ-LWBDLB1WB-WUS-4K-BT, ZJ-LWBDLE2WW-WUS-4K-BT,ZJ-LWBDLE1WB-WUS-4K-BT, ZJ-RLTD-PBFHH-D1US2S,ZJ-RLTD-PBFLST-D1US2S, ZJ-RLTD-PBSSJ-D1US2S,ZJ-RLTD-PBPSY-D1US2S,ZJ-RLTD-PBPSB-D1US2S, ZJ-RLTD-DBHSH-D1US2S,ZJ-RLTD-DBHLST-D1US2S,ZJ-RLTD-DBHSJ-D1US2S, ZJ-RLTD-DBHSY-D1US2S,ZJ-RLTD-DBHSB-D1US2S,ZJ-RLTD-PTBH-D1US2S, ZJ-RLTD-PTBH-D1JP2S,ZJ-RLTD-PTBH-D2AP2S FCCID:2BXIC-ZJ-LWBDLA1WB ZJ-LWBDLA1WB-WUS-4K-BTistestedmodel,othermodelsarederivative models.Themodelsareidenticalincircuit,onlydifferentonthemodelnames.Sothe testdataofZJ-LWBDLA1WB-WUS-4K-BTcanrepresenttheremainingmodels. Client’ssignature: Client’sname/title:BriturnLin/Manager Contactinformation/address:Unit601,6thFloor,Building2,No.7DongshengRoad, JianghaiDistrict,JiangmenCity,GuangdongProvince,China

External Photos

FCCID:2BXIC-ZJ-LWBDLA1WB EUTPHOTOSExternalPhotos FCCID:2BXIC-ZJ-LWBDLA1WB FCCID:2BXIC-ZJ-LWBDLA1WB FCCID:2BXIC-ZJ-LWBDLA1WB ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

Size:4mm*30mm FCCID:2BXIC-ZJ-LWBDLA1WB

Internal Photos

FCCID:2BXIC-ZJ-LWBDLA1WB EUTPHOTOSInternalPhotos FCCID:2BXIC-ZJ-LWBDLA1WB FCCID:2BXIC-ZJ-LWBDLA1WB FCCID:2BXIC-ZJ-LWBDLA1WB ※※※※※ENDOFREPORT※※※※※ ANT

RF Exposure Info

FCCID:2BXIC-ZJ-LWBDLA1WB RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1091, UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactof humanexposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency range (MHz) Electricfield strength (V/m) Magneticfield strength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthe totalpowerinputtotheantenna,throughthecalculation,wewillknowthedistancerwhere theMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middle andhighestchannelindividually. TestResultofRFExposureEvaluation Mode Max.Output powerto antenna (dBm) Max.Output powerto antenna (mW) Max.Power Densityat R=20cm (mW/cm2) Limit (mW/cm2) Result 2.4GWIFI15.9439.260.01391.0PASS BLE4.392.750.00101.0PASS Remark:2.4GWIFI,BLEAntennagain=2.5dBi.

Test Report

ProjectNo.:ZHT-260720125W01-1 Page 1 of 55 FCCTESTREPORT FCCID:2BXIC-ZJ-LWBDLA1WB ApplicantName...............:JMZenggeLightingCo.,LTD Address............................:Unit601,6thFloor,Building2,No.7DongshengRoad,JianghaiDistrict, JiangmenCity,GuangdongProvince,China ManufacturerName.........:JMZenggeLightingCo.,LTD Address............................:Unit601,6thFloor,Building2,No.7DongshengRoad,JianghaiDistrict, JiangmenCity,GuangdongProvince,China Product............................:CandleWarmerLamp Model(s)...........................:ZJ-LWBDLA1WB-WUS-4K-BT AdditionalModel(s)..........:ZJ-LWBDLA2WW-WUS-4K-BT,ZJ-LWBDLA3WC-WUS-4K-BT, ZJ-LWBDLA4WC-WUS-4K-BT,ZJ-LWBDLA5WS-WUS-4K-BT, ZJ-LWBDLC1WB-WUS-4K-BT,ZJ-LWBDLC2WW-WUS-4K-BT, ZJ-LWBDLC3WC-WUS-4K-BT,ZJ-LWBDLC4WS-WUS-4K-BT, ZJ-LWBDLC5WY-WUS-4K-BT,ZJ-LWBDLD2WW-WUS-4K-BT, ZJ-LWBDLD1WB-WUS-4K-BT,ZJ-LWBDLB2WW-WUS-4K-BT, ZJ-LWBDLB1WB-WUS-4K-BT,ZJ-LWBDLE2WW-WUS-4K-BT, ZJ-LWBDLE1WB-WUS-4K-BT,ZJ-RLTD-PBFHH-D1US2S, ZJ-RLTD-PBFLST-D1US2S,ZJ-RLTD-PBSSJ-D1US2S, ZJ-RLTD-PBPSY-D1US2S,ZJ-RLTD-PBPSB-D1US2S, ZJ-RLTD-DBHSH-D1US2S,ZJ-RLTD-DBHLST-D1US2S, ZJ-RLTD-DBHSJ-D1US2S,ZJ-RLTD-DBHSY-D1US2S, ZJ-RLTD-DBHSB-D1US2S,ZJ-RLTD-PTBH-D1US2S, ZJ-RLTD-PTBH-D1JP2S,ZJ-RLTD-PTBH-D2AP2S Trademark.......................:/ ModelDifference..............:ZJ-LWBDLA1WB-WUS-4K-BTistestedmodel,othermodelsarederivative models.Themodelsareidenticalincircuit,onlydifferentonthemodel names.SothetestdataofZJ-LWBDLA1WB-WUS-4K-BTcanrepresentthe remainingmodels. Preparedby.....................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:July20,2026 DateofTest(s).................:July20,2026toJuly28,2026 DateofIssue....................:July28,2026 TestRequested................:Selecttest(s)asrequestedbytheclient. TestStandard(s)..............:FCCCFRTitle47Part15SubpartCSection15.247 Testprocedure................:KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+ErratatoC63.10a-2024 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby:Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:Theresultsshowninthistestreportreferonlytothesample(s)testedunlessotherwisestated.Thistest reportshallnotbereproducedexceptinfull,withoutpriorwrittenapprovalofZHT.Thisdocumentmaybe alteredorrevisedbyZHT,personnelonly,andshallbenotedintherevisionofthedocument. ProjectNo.:ZHT-260720125W01-1 Page 2 of 55 TableofContents Page 1.SUMMARYOFTESTRESULTS.............................................................................................................4 2.GENERALINFORMATION.....................................................................................................................5 2.1GENERALDESCRIPTIONOFEUT...............................................................................................5 2.2DESCRIPTIONOFTESTMODES..................................................................................................6 2.3TESTSETUPCONFIGURATION....................................................................................................7 2.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)......................................................7 3.TESTFACILITYANDTESTINSTRUMENTUSED................................................................................8 3.1TESTFACILITY...............................................................................................................................8 3.2EQUIPMENTSLISTFORALLTESTITEMS.................................................................................8 3.3TESTINGSOFTWARE....................................................................................................................9 3.4MEASUREMENTUNCERTAINTY................................................................................................10 4.EMCEMISSIONTEST..........................................................................................................................11 4.1CONDUCTEDEMISSIONMEASUREMENT................................................................................11 4.1.1POWERLINECONDUCTEDEMISSIONLimits.................................................................11 4.1.2TESTPROCEDURE.............................................................................................................11 4.1.3DEVIATIONFROMTESTSTANDARD................................................................................11 4.1.4TESTSETUP........................................................................................................................12 4.1.5EUTOPERATINGCONDITIONS.........................................................................................12 4.1.6TESTRESULTS...................................................................................................................13 4.2RADIATEDEMISSIONMEASUREMENT.....................................................................................15 4.2.1RADIATEDEMISSIONLIMITS............................................................................................15 4.2.2TESTPROCEDURE.............................................................................................................16 4.2.3DEVIATIONFROMTESTSTANDARD................................................................................16 4.2.4TESTSETUP........................................................................................................................16 4.2.5EUTOPERATINGCONDITIONS.........................................................................................17 5.RADIATEDBANDEMISSIONMEASUREMENT.................................................................................23 5.1TESTREQUIREMENT:...........................................................................................................23 5.2TESTPROCEDURE....................…

Text truncated - open the document above for the full version.

Test Report

ProjectNo.:ZHT-260720125W01-2 Page 1 of 76 FCCTESTREPORT FCCID:2BXIC-ZJ-LWBDLA1WB ApplicantName...............:JMZenggeLightingCo.,LTD Address............................:Unit601,6thFloor,Building2,No.7DongshengRoad,JianghaiDistrict, JiangmenCity,GuangdongProvince,China ManufacturerName.........:JMZenggeLightingCo.,LTD Address............................:Unit601,6thFloor,Building2,No.7DongshengRoad,JianghaiDistrict, JiangmenCity,GuangdongProvince,China Product............................:CandleWarmerLamp Model(s)...........................:ZJ-LWBDLA1WB-WUS-4K-BT AdditionalModel(s)..........:ZJ-LWBDLA2WW-WUS-4K-BT,ZJ-LWBDLA3WC-WUS-4K-BT, ZJ-LWBDLA4WC-WUS-4K-BT,ZJ-LWBDLA5WS-WUS-4K-BT, ZJ-LWBDLC1WB-WUS-4K-BT,ZJ-LWBDLC2WW-WUS-4K-BT, ZJ-LWBDLC3WC-WUS-4K-BT,ZJ-LWBDLC4WS-WUS-4K-BT, ZJ-LWBDLC5WY-WUS-4K-BT,ZJ-LWBDLD2WW-WUS-4K-BT, ZJ-LWBDLD1WB-WUS-4K-BT,ZJ-LWBDLB2WW-WUS-4K-BT, ZJ-LWBDLB1WB-WUS-4K-BT,ZJ-LWBDLE2WW-WUS-4K-BT, ZJ-LWBDLE1WB-WUS-4K-BT,ZJ-RLTD-PBFHH-D1US2S, ZJ-RLTD-PBFLST-D1US2S,ZJ-RLTD-PBSSJ-D1US2S, ZJ-RLTD-PBPSY-D1US2S,ZJ-RLTD-PBPSB-D1US2S, ZJ-RLTD-DBHSH-D1US2S,ZJ-RLTD-DBHLST-D1US2S, ZJ-RLTD-DBHSJ-D1US2S,ZJ-RLTD-DBHSY-D1US2S, ZJ-RLTD-DBHSB-D1US2S,ZJ-RLTD-PTBH-D1US2S, ZJ-RLTD-PTBH-D1JP2S,ZJ-RLTD-PTBH-D2AP2S Trademark.......................:/ ModelDifference..............:ZJ-LWBDLA1WB-WUS-4K-BTistestedmodel,othermodelsarederivative models.Themodelsareidenticalincircuit,onlydifferentonthemodel namesandcolors.SothetestdataofZJ-LWBDLA1WB-WUS-4K-BTcan representtheremainingmodels. Preparedby.....................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:July20,2026 DateofTest(s).................:July20,2026toJuly28,2026 DateofIssue....................:July28,2026 TestRequested................:Selecttest(s)asrequestedbytheclient. TestStandard(s)..............:FCCCFRTitle47Part15SubpartCSection15.247 Testprocedure................:KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+ErratatoC63.10a-2024 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby:Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:Theresultsshowninthistestreportreferonlytothesample(s)testedunlessotherwisestated.Thistest reportshallnotbereproducedexceptinfull,withoutpriorwrittenapprovalofZHT.Thisdocumentmaybe alteredorrevisedbyZHT,personnelonly,andshallbenotedintherevisionofthedocument. ProjectNo.:ZHT-260720125W01-2 Page 2 of 76 TableofContents Page 1.SUMMARYOFTESTRESULTS................................................................................................................4 2.GENERALINFORMATION........................................................................................................................5 2.1GENERALDESCRIPTIONOFEUT..................................................................................................5 2.3DESCRIPTIONOFTESTMODES.....................................................................................................6 2.4BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED................................7 2.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................7 3.TESTFACILITYANDTESTINSTRUMENTUSED...................................................................................8 3.1TESTFACILITY..................................................................................................................................8 3.2EQUIPMENTSLISTFORALLTESTITEMS....................................................................................8 3.3TESTINGSOFTWARE.......................................................................................................................9 3.4MEASUREMENTUNCERTAINTY...................................................................................................10 4.EMCEMISSIONTEST.............................................................................................................................11 4.1CONDUCTEDEMISSIONMEASUREMENT...................................................................................11 4.1.1POWERLINECONDUCTEDEMISSIONLimits....................................................................11 4.1.2TESTPROCEDURE................................................................................................................11 4.1.3DEVIATIONFROMTESTSTANDARD...................................................................................11 4.1.4TESTSETUP...........................................................................................................................12 4.1.5EUTOPERATINGCONDITIONS............................................................................................12 4.1.6TESTRESULT.........................................................................................................................13 4.2RADIATEDEMISSIONMEASUREMENT.......................................................................................15 4.2.1RADIATEDEMISSIONLIMITS...............................................................................................15 4.2.2TESTPROCEDURE................................................................................................................15 4.2.3DEVIATIONFROMTESTSTANDARD..................................................................................16 4.2.4TESTSETUP...........................................................................................................................16 4.2.5EUTOPERATINGCONDITIONS............................................................................................17 4.2.6TESTRESULTS......................................................................................................................17 5.RADIATEDBANDEMISSIONMEASUREMENT..................................................…

Text truncated - open the document above for the full version.

Test Report

ProjectNo.:ZHT-260720125W01-2 Page 51 of 76 OBWNVNTn202412MHzAnt1 OBWNVNTn202437MHzAnt1 ProjectNo.:ZHT-260720125W01-2 Page 52 of 76 OBWNVNTn202462MHzAnt1 ProjectNo.:ZHT-260720125W01-2 Page 53 of 76 11.5MAXIMUMPOWERSPECTRALDENSITYLEVEL ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTb2412Ant11.428Pass NVNTb2437Ant12.548Pass NVNTb2462Ant11.648Pass NVNTg2412Ant1-5.578Pass NVNTg2437Ant1-4.688Pass NVNTg2462Ant1-5.528Pass NVNTn202412Ant1-6.358Pass NVNTn202437Ant1-5.648Pass NVNTn202462Ant1-4.778Pass ProjectNo.:ZHT-260720125W01-2 Page 54 of 76 PSDNVNTb2412MHzAnt1 PSDNVNTb2437MHzAnt1 ProjectNo.:ZHT-260720125W01-2 Page 55 of 76 PSDNVNTb2462MHzAnt1 PSDNVNTg2412MHzAnt1 ProjectNo.:ZHT-260720125W01-2 Page 56 of 76 PSDNVNTg2437MHzAnt1 PSDNVNTg2462MHzAnt1 ProjectNo.:ZHT-260720125W01-2 Page 57 of 76 PSDNVNTn202412MHzAnt1 PSDNVNTn202437MHzAnt1 ProjectNo.:ZHT-260720125W01-2 Page 58 of 76 PSDNVNTn202462MHzAnt1 ProjectNo.:ZHT-260720125W01-2 Page 59 of 76 11.6BANDEDGE ModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict b2412Ant1-37.01-20Pass b2462Ant1-56.21-20Pass g2412Ant1-44.52-20Pass g2462Ant1-53.89-20Pass n202412Ant1-47.08-20Pass n202462Ant1-54.03-20Pass ProjectNo.:ZHT-260720125W01-2 Page 60 of 76 BandEdgeNVNTb2412MHzAnt1Ref BandEdgeNVNTb2412MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 61 of 76 BandEdgeNVNTb2462MHzAnt1Ref BandEdgeNVNTb2462MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 62 of 76 BandEdgeNVNTg2412MHzAnt1Ref BandEdgeNVNTg2412MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 63 of 76 BandEdgeNVNTg2462MHzAnt1Ref BandEdgeNVNTg2462MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 64 of 76 BandEdgeNVNTn202412MHzAnt1Ref BandEdgeNVNTn202412MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 65 of 76 BandEdgeNVNTn202462MHzAnt1Ref BandEdgeNVNTn202462MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 66 of 76 11.7CONDUCTEDRFSPURIOUSEMISSION ModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict b2412Ant1-42.74-20Pass b2437Ant1-43.98-20Pass b2462Ant1-42.80-20Pass g2412Ant1-38.99-20Pass g2437Ant1-39.94-20Pass g2462Ant1-39.00-20Pass n202412Ant1-41.16-20Pass n202437Ant1-41.54-20Pass n202462Ant1-41.28-20Pass ProjectNo.:ZHT-260720125W01-2 Page 67 of 76 Tx.SpuriousNVNTb2412MHzAnt1Ref Tx.SpuriousNVNTb2412MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 68 of 76 Tx.SpuriousNVNTb2437MHzAnt1Ref Tx.SpuriousNVNTb2437MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 69 of 76 Tx.SpuriousNVNTb2462MHzAnt1Ref Tx.SpuriousNVNTb2462MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 70 of 76 Tx.SpuriousNVNTg2412MHzAnt1Ref Tx.SpuriousNVNTg2412MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 71 of 76 Tx.SpuriousNVNTg2437MHzAnt1Ref Tx.SpuriousNVNTg2437MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 72 of 76 Tx.SpuriousNVNTg2462MHzAnt1Ref Tx.SpuriousNVNTg2462MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 73 of 76 Tx.SpuriousNVNTn202412MHzAnt1Ref Tx.SpuriousNVNTn202412MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 74 of 76 Tx.SpuriousNVNTn202437MHzAnt1Ref Tx.SpuriousNVNTn202437MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 75 of 76 Tx.SpuriousNVNTn202462MHzAnt1Ref Tx.SpuriousNVNTn202462MHzAnt1Emission ProjectNo.:ZHT-260720125W01-2 Page 76 of 76 12.TESTSETUPPHOTO ReferencetotheappendixIfordetails. 13.EUTCONSTRUCTIONALDETAILS ReferencetotheappendixIIfordetails. ※※※※※ENDOFREPORT※※※※※

Test Report

AntennaSpecification ElectricalSpecification ModelMeanderline FrequencyRange(MHz) 2402-2480 Bandwidth(MHz) 79 VSWR ≤2 Gain(dBi) 2.5 InputImpedance(Ω) 50 PolarizationType Linear AntennaLength(mm) 29mm Pattern 0mni-directional Antennatype PCBantenna MANUFACTURER ShenZhenBelonSolutionsCo.,Ltd Address: Room901-902,BuildingA,No.2, ShenzhenInternationalInnovation Valley,Dashi1stRoad,XiliCommunity, XiliStreet,NanshanDistrict,Shenzhen. EquipmentunderTest No.EUTstatus 1#intact Testmethod Test5antennasunderStandardIEEE149-1979andrecordthetest results(firsttestresults). TestSetup TestEquipmentList DescriptionManufacturerModelSerialNo.Cal.DateCal.Due VectorNetworkAnalyzerAgilentE5071CMY461034722018.1.252019.1.25 5*5*5FullAnechoicChamberSATIMO5*5*5CN-1307-5552018.09.282019.09.28 SG24Multi-probeAntenna MeasurementSystem SATIMOSG24-L1101855-00012018.12.42019.12.4 TestUncertainty ItemUncertainty Gain±0.5dB Gain&Efficiency Dimension PolarGraphs(2400/2440/2480MHz) RadiationPattern3D 2402MHZ2440MHZ2483MHZ

Test Setup Photos

FCCID:2BXIC-ZJ-LWBDLA1WB EUTTESTPHOTOS FCCID:2BXIC-ZJ-LWBDLA1WB ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

Briturn Lin(Manger)
[email protected]Fax: 15875583798

Technical Contact

GOLDEN VICTORY INTERNATIONAL TRADING CO LTDLeon Howar
[email protected]

110 16TH STREET SUITE 1400 DENVER, · United States

Test Firm

Guangdong Zhonghan Testing Technology Co., Ltd.Alex Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz39.30 mW
215C2.41 GHz - 2.46 GHz2.70 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.