FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GVS SMART CO., LTD./
  3. 2BXJRCHTI7012012

2BXJRCHTI7012012KNX Smart Touch S7

GVS SMART CO., LTD.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 10, 2026
Application Purpose
Original Equipment
Equipment Note
KNX Smart Touch S7
Frequency Range
2402.00000000 - 2480.00000000
Company
GVS SMART CO., LTD.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E04 TRF No.: RT-4-E-006Page 1 of 7 RF EXPOSURE REPORT Applicant : GVS SMART CO., LTD. Address of Applicant : 3/F, Building 5, No.9/4th, Lanyu Street, Huangpu District, Guangzhou 510730, China. Manufacturer : GVS SMART CO., LTD. Address of Manufacturer : 3/F, Building 5, No.9/4th, Lanyu Street, Huangpu District, Guangzhou 510730, China. Equipment under Test : KNX Smart Touch S7 Model No. : CHTI-7.0/120.1.23, CHTI-7.0/120.1.22 FCC ID : 2BXJRCHTI7012012 Test Standard(s) : KDB447498 D01 General RF Exposure Guidance v06 Report No. : DDT-RE26061901-2E04 Issue Date : 2026/09/04 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E04 TRF No.: RT-4-E-006Page 2 of 7 Table of Contents 1.General Test Information..............................................................................................5 1.1.Description of EUT .......................................................................................................5 1.2.Accessories of EUT......................................................................................................5 1.3.Test laboratory .............................................................................................................5 2.RF Exposure evaluation for FCC .................................................................................6 2.1.Assessment procedure.................................................................................................6 2.2.Assess result ................................................................................................................7 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E04 TRF:RT-4-E-006Page 3 of 7 $!CeMetaLims!digital$ Test Report Declare Applicant : GVS SMART CO., LTD. Address of Applicant : 3/F, Building 5, No.9/4th, Lanyu Street, Huangpu District, Guangzhou 510730, China. Equipment under Test : KNX Smart Touch S7 Model No. : CHTI-7.0/120.1.23, CHTI-7.0/120.1.22 Manufacturer : GVS SMART CO., LTD. Address of Manufacturer : 3/F, Building 5, No.9/4th, Lanyu Street, Huangpu District, Guangzhou 510730, China. Test Standard Used: KDB447498 D01 General RF Exposure Guidance v06 We Declare: The equipment described above is tested by Guangdong Dongdian Testing Service Co., Ltd. and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Guangdong Dongdian Testing Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. Report No.:DDT-RE26061901-2E04 Date of Receipt:2026/07/02Date of Test:2026/07/02~2026/08/01 Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Guangdong Dongdian Testing Service Co., Ltd. Created: Johnson HuangReviewed: Tiger MoApproved: Ella Gong 2026/08/012026/09/042026/09/04 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E04 TRF:RT-4-E-006Page 4 of 7 Revision History VersionRevision ContentIssue DateApproved V0Initial issue2026/09/04Ella Gong Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E04 TRF:RT-4-E-006Page 5 of 7 1. General Test Information 1.1. Description of EUT EUT Name:KNX Smart Touch S7 Model Number:CHTI-7.0/120.1.23, CHTI-7.0/120.1.22 Difference of model number: All models of circuits, electronic components, wireless module and antenna are exactly the same, except for differences in color, therefore the test performed on the model CHTI-7.0/120.1.23. EUT Function Description:Please reference user manual of this device Power Supply: KNX terminal voltage: 21-30V DC, Auxiliary supply voltage: 12-30V DC Note: The above EUT information is declared by manufacturer and for more detailed features description please refer to the manufacturer's specifications or User's Manual. 1.2. Accessories of EUT AccessoriesManufacturerModel numberDescription //// 1.3. Test laboratory Guangdong Dongdian Testing Service Co., Ltd. Add.: Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808. Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected]. CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, R-20240, G-20118 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E04 TRF:RT-4-E-006Page 6 of 7 2. RF Exposure evaluation for FCC 2.1. Assessment procedure Requirement: Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic FieldStrength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.346141.63(100)*30 1.34-30824/f2.19/f(180/f)*30 30-30027.50.0730.230 300-1500 F/150030 1500-100000 1.030 Note: f= frequency in MHz; *Plane-wave equivalent power density Calculation method From the peak EUT RF output power, the minimum mobile separation distance, d=0.2 m, as well as the gain of the used antenna, the RF power density can be obtained. Guangdong Dongdian Testing Servi…

Text truncated - open the document above for the full version.

Test Report

东莞市一佳电子通讯科技有限公司 Dongguan YiJia Electronics Communication Technology Co.,Ltd. 规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2023/08/21 编号 File No 23082102 版本 Revision 1.0 客户 CUSTOMER: 视声智能 客户料号 CUSTOMER NO: S7 品名 WIFI/BT Antenna L 35mm MHF 品名 PART NAME: WIFI/BT Antenna L=35mm MHF 供方料号 SUPPLIER NO: YJL01.098.024.302A 送样日期 Date: 送样数量Q“TY: 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 APPROVALCHECKDESIGN ChenGuoqiangXieLiChenXingyi YJ-RD-F04-A 承认书项目表 NO . 内容 (Contents) 页数 (Number of Page) 页码 (Page Code) 1 承认书封面(Spec Cover) 11 承认书封面(p) 2 承认书项目表(Spec Item ) 12 3 工程成品图(Drawing) 13 4 天线规格(Antenna Specification) 14 5 S参数测试(S Parameter ) 15 6 无源测试(Passive Test ) 16 7 方向图(Radiation Pattern ) 47 ~ 10 8 天线装配图(Antenna Profile) 311~ 13 9 材质证明(Mt ilC tifi t) 4314 569 材质证明(Material Certificate ) 4314 ~ 56 10 RoHS报告(RoHS Test Report ) **** 11N/AN/AN/A add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 12--- 13--- 天线规格 Antenna Specification Electrical Properties Frequency 2.4-2.5GHz qy Impedance50 Ohm Nominal V.S.W.R2.0 Max Gain 22dBi Gain 2.2 dBi RadiationOmni-directional PolarizationLinear Physical Properties Connector 4代IPEX Cable TypeO.D.0.81mm Cable Length35mm Cable ColorBlack add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Operating Temp.-40 ~ +85 ̊C Storage Temp / Humidity 25±5 ̊C / <70% Antenna Performance TestAntenna Performance Te s t AgilentAgilent E5071B S11 ParameterParameter Test // WiFi AntennaAntenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Passive Test For WiFi Antenna FreqEffiEffiGain (MHz)(%)(dB)(dBi) 2400 41.8 -3.82.2 2410 42.9 -3.72.0 2420 42.6 -3.71.9 2430 42.0 -3.81.8 2440 41.6 -3.81.8 2450 42.8 -3.71.9 2460 40.7 -3.91.7 2470 41.4 -3.81.8 2480 39.6 -4.01.7 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 2490 39.7 -4.01.8 2500 37.3 -4.31.6 Radiation Pattern For WiFi Antenna ( 2400MHz ) add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For WiFi Antenna ( 2450MHz ) add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For WiFi Antenna ( 2500MHz ) add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For WiFi Antenna Phi 0° Phi 90° Theta 90° add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 eta90 PSM-800FSDM-A/SMH-800 , 安 全 資 料 表 1 版權 2021-01-10 First, chemical products and materials for business Chemical name: PSM-800FSDM-A/SMH-800 liquid solid plate ink Other names: Use and restricted use of construction: flexible printed circuit board (PI/Cu), hand machine roof board Name, address and address of the creator, entrant or supplier: Creator: Yueli Reachability Co., Ltd. Address: No.22 Jingjian Fourth Road, Guanyin District, Taoyuan City: 886-3- 4836651 Urgent/true: 886-3-4836651, true: 886-3-4837487 Second, the hazard identification of resources and materials Hazard classification of chemical products: Health and environmental hazards: Acute toxicity (swallowing) 4, rot/skin irritation 2, heavy weight/eye irritation 2, skin Pass sensitive substance first, carcinogenic substance second, and hazardous substance second (acute toxicity). Indication of content: S y m b o l n u m b e r : Warning language: Warning hazard warning interest: Harmful to swallow Cause skin irritation Causing severe eye irritation may cause skin hypersensitivity and suspected carcinogenesis Toxic to aquatic organisms Hazard prevention measures: Put the container in a place with good ventilation far away from the high temperature Do not eat or drink when using Remove the blindfold/face mask immediately when your clothes are contaminated If you touch your eyes, wash them with plenty of water immediately, and then ask the mud to wear suitable gloves Do not inhale gas/gas/steam gas/gas before use Place it in the upper lock Do not place until you know all safety precautions Avoid releasing release in the environment Other hazards:- III. Composition identification of PSM-800FSDM-A/SMH-800 , 安 全 資 料 表 2 版權 2021-01-10 capital mixture: Liquid solid plate ink PSM-800FSDM-A/SMH-800 Chemical geology: Chinese and English names of hazardous components Register number of Chemical Digest Service (CAS No.) Degree or degree (percentage of components) Oxygen acrylate oligmer Epoxy acrylate oligmer 28064-14-4 50% Silicon dioxide Fused silica 7631-86-9 13% Aromatic solution 64742-94-5 4% PSM-800FSDM-A/SMH-800 , 安 全 資 料 表 3 版權 2021-01-10 Methyl dipropylene glycol 34590-94-8 4% Carbon black 1333-86-4 3.5% BaSO4 sulfate 13462-86-7 24% Photoinitiator and the others 5495-84-1 1.5% Fourth, first aid measures First aid methods for the same road: Inhalation: 1. Take self-protection measures before rescue. 2. Remove pollution sources or move patients to new places. 3. If a patient stops breathing, artificial respiration should be given immediately by the person who has been adalmed. If the heart stops, cardiopulmonary resuscitation should be given. When the patient inhales and swallows toxic substances, mouth-to-mouth artificial respiration should be used directly, and pocket masks and other medical equipment should be used for artificial respiration. 4. Maintain the patient's safety and normal temperature. 6. Treat the cure quickly. Pi Mo: Wash the contaminated area with harmonious water for at least 20 minutes, and remove contaminated clothes, shoes and leather products before water. Eye touching: Immediately open the eyelids and wash the contaminated eyes with water for at least 20 minutes, and immediately take care of them. Intake: 1. If the patient will be frustrated, or has been frustrated, he can feed anything. 2. It can induce vomiting and give 240-300ml of water. 3. If you vomit spontaneously, rinse your mouth and supply water repeatedly. The most important diseases and harmful effects:- Protection against first aid workers:- Tips for doctors:- V. Fire measures Suitable for fire: chemical dry po…

Text truncated - open the document above for the full version.

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E01 TRF: RT-4-E-005Page 1 of 108 RADIO TEST REPORT Applicant : GVS SMART CO., LTD. Address of Applicant : 3/F, Building 5, No.9/4th, Lanyu Street, Huangpu District, Guangzhou 510730, China. Manufacturer : GVS SMART CO., LTD. Address of Manufacturer : 3/F, Building 5, No.9/4th, Lanyu Street, Huangpu District, Guangzhou 510730, China. Equipment under Test : KNX Smart Touch S7 Model No. : CHTI-7.0/120.1.23, CHTI-7.0/120.1.22 FCC ID : 2BXJRCHTI7012012 IC : 36018-CHTI7012012 Test Standard(s) : FCC Rules and Regulations Part 15 Subpart C, ANSI C63.10-2020+Cor.1-2023, RSS-247 Issue 4 July 24, 2025, RSS-Gen Issue 5, Apr. 2018, Amendment 2 (February 2021), ANSI C63.10-2020+Cor.1-2023+C63.10a-2024+Errata to C63.10a-2024 Report No. : DDT-RE26061901-2E01 Issue Date : 2026/09/04 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E01 TRF: RT-4-E-005Page 2 of 108 Table of Contents 1.Summary of Test Results .............................................................................................7 2.General Test Information..............................................................................................8 2.1.Description of EUT .......................................................................................................8 2.2.Accessories of EUT......................................................................................................9 2.3.Block diagram of EUT configuration for test.................................................................9 2.4.Decision of final test mode ...........................................................................................9 2.5.Deviations of test standard.........................................................................................10 2.6.Test environment conditions ......................................................................................10 2.7.Test laboratory ...........................................................................................................11 2.8.Measurement uncertainty...........................................................................................12 3.Equipment Used During Conductive Test ..................................................................13 4.20 dB Bandwidth ........................................................................................................14 4.1.Block diagram of test setup ........................................................................................14 4.2.Limits ..........................................................................................................................14 4.3.Test procedure ...........................................................................................................14 4.4.Test result...................................................................................................................15 4.5.Test graphs ................................................................................................................16 5.99% Bandwidth ..........................................................................................................20 5.1.Block diagram of test setup ........................................................................................20 5.2.Limits ..........................................................................................................................20 5.3.Test procedure ...........................................................................................................20 5.4.Test result...................................................................................................................21 5.5.Test graphs ................................................................................................................22 6.Maximum Peak Output Power....................................................................................26 6.1.Block diagram of test setup ........................................................................................26 6.2.Limits ..........................................................................................................................26 6.3.Test procedure ...........................................................................................................26 6.4.Test result...................................................................................................................27 6.5.Test graphs ................................................................................................................28 7.Carrier Frequency Separation ....................................................................................32 7.1.Block diagram of test setup ........................................................................................32 7.2.Limits ..........................................................................................................................32 7.3.Test procedure ...........................................................................................................32 7.4.Test result...................................................................................................................33 7.5.Test graphs ................................................................................................................34 8.Dwell Time..................................................................................................................36 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26061901-2E01 TRF: RT-4-E-005Page 3 of 108 8.1.Block diagram of test setup ........................................................................................36 8.2.Limits ..........................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Hongwei Li(Compliance & Certification Supervisor)
[email protected]Fax: N/A

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue, Saint Charles, IL · Saint charles, Illinois, 60174 · United States

Test Firm

Guangdong Dongdian Testing Service Co., Ltd.Mr. Jamy Yu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.