Shenzhen Xinghe Video Communication Co., Ltd 2F,Bud F,Hongzhu Yongqi Technology Park,LezhujiaoVillage, Jiuwei Community,Hangcheng Street,Bao'an,District,Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/08/08 U.S. Agent Designation Shenzhen Xinghe Video Communication Co., Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BXL6-MORTALX5S): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Phone of U.S. agent: (626) 588-8039 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of Shenzhen Xinghe Video Communication Co., Ltd with the FRN [0038755724] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature Fengxiang li Manager Shenzhen Xinghe Video Communication Co., Ltd Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
FCC ID: 2BXL6-MORTALX5S External Photos of the EUT FCC ID: 2BXL6-MORTALX5S FCC ID: 2BXL6-MORTALX5S
Label and Location Size: L: 3.0cm*W: 2.0cm Label and Location FCC ID : 2BXL6-MORTALX5S
FCC ID: 2BXL6-MORTALX5S Internal Photos of the EUT FCC ID: 2BXL6-MORTALX5S ANT
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure MPE Report Reference No. ..................... : FCC ID............................................. : CTA26070601204 2BXL6-MORTALX5S Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jul. 14, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Xinghe Video Communication Co., Ltd Address............................................ : 2F,Bud F,Hongzhu Yongqi Technology Park,LezhujiaoVillage, Jiuwei Community,Hangcheng Street,Bao'an,District,Shenzhen, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : TV BOX Trade Mark ....................................... : MORTAL Manufacturer .................................... : Shenzhen Xinghe Video Communication Co., Ltd Model/Type reference ...................... : MORTAL X5S Listed Models ................................... : T1+, T1, Q7, R69-1, T1MINI, R3+, TVR3+, M1, Q8, T1 ULTRA, Q2ULTRA Ratings ............................................. : Input: 5V2.0A Result ............................................... : PASS Report No.: CTA26070601204 Page 2 of 11 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : TV BOX Model /Type : MORTAL X5S Listed Models : T1+, T1, Q7, R69-1, T1MINI, R3+, TVR3+, M1, Q8, T1 ULTRA, Q2ULTRA Model difference : The PCB board, circuit, structure and internal of these models are the same, only model number and colour are different for these model. So the tests were performed on model MORTAL X5S and the test results for the main test model can cover the listed models. Applicant : Shenzhen Xinghe Video Communication Co., Ltd Address : 2F,Bud F,Hongzhu Yongqi Technology Park,LezhujiaoVillage, Jiuwei Community,Hangcheng Street,Bao'an,District,Shenzhen, China Manufacturer : Shenzhen Xinghe Video Communication Co., Ltd Address : 2F,Bud F,Hongzhu Yongqi Technology Park,LezhujiaoVillage, Jiuwei Community,Hangcheng Street,Bao'an,District,Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26070601204 Page 3 of 11 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 6 2.4 Modifications ............................................................................................................ 6 3 TEST ENVIRONMENT ....................................................................................................... 7 3.1 Address of the test laboratory .................................................................................. 7 3.2 Test Facility .............................................................................................................. 7 3.3 Statement of the measurement uncertainty ............................................................. 7 4 Test limit .............................................................................................................................. 8 4.1 Requirement ............................................................................................................ 8 4.2 MPE Calculation Method ......................................................................................... 8 4.3 Conducted Power Results ....................................................................................... 9 4.4 Manufacturing tolerance ........................................................................................ 10 4.5 Standalone MPE Result ......................................................................…
Text truncated - open the document above for the full version.
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .................... : FCC ID. ........................................... : CTA26070601201 2BXL6-MORTALX5S Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jul. 14, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Shenzhen Xinghe Video Communication Co., Ltd Address ............................................ : 2F,Bud F,Hongzhu Yongqi Technology Park,LezhujiaoVillage, Jiuwei Community,Hangcheng Street,Bao'an,District,Shenzhen, China Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : TV BOX Trade Mark ....................................... : MORTAL Manufacturer .................................... : Shenzhen Xinghe Video Communication Co., Ltd Model/Type reference ...................... : MORTAL X5S Listed Models ................................... : T1+, T1, Q7, R69-1, T1MINI, R3+, TVR3+, M1, Q8, T1 ULTRA, Q2ULTRA Modulation ....................................... : GFSK, Π/4DQPSK, 8DPSK Frequency ........................................ : From 2402MHz to 2480MHz Ratings ............................................. : Input: 5V2.0A Result ............................................... : PASS Report No.: CTA26070601201 Page 2 of 38 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : TV BOX Model /Type : MORTAL X5S Listed Models : T1+, T1, Q7, R69-1, T1MINI, R3+, TVR3+, M1, Q8, T1 ULTRA, Q2ULTRA Model difference : The PCB board, circuit, structure and internal of these models are the same, only model number and colour are different for these model. So the tests were performed on model MORTAL X5S and the test results for the main test model can cover the listed models. Applicant : Shenzhen Xinghe Video Communication Co., Ltd Address : 2F,Bud F,Hongzhu Yongqi Technology Park,LezhujiaoVillage, Jiuwei Community,Hangcheng Street,Bao'an,District,Shenzhen, China Manufacturer : Shenzhen Xinghe Video Communication Co., Ltd Address : 2F,Bud F,Hongzhu Yongqi Technology Park,LezhujiaoVillage, Jiuwei Community,Hangcheng Street,Bao'an,District,Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26070601201 Page 3 of 38 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description ........................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 6 2.6 EUT operation mode ......................................................................................................................... 6 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address…
Text truncated - open the document above for the full version.
1 FCC Appendix RF Test Data for BT FCC ID : 2BXL6-MORTALX5S Company : Shenzhen Xinghe Video Communication Co., Ltd EUT : TV BOX Model Number : MORTAL X5S Report No. : CTA26070601201 Reviewed By : Eric Wang 2 Appendix A: 20dB Emission Bandwidth Test Result TestMode Antenna Freq(MHz) 20dB EBW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.945 2401.553 2402.498 --- --- 2441 0.945 2440.544 2441.489 --- --- 2480 0.954 2479.544 2480.498 --- --- 2DH5 Ant1 2402 1.353 2401.331 2402.684 --- --- 2441 1.326 2440.343 2441.669 --- --- 2480 1.287 2479.376 2480.663 --- --- 3DH5 Ant1 2402 1.293 2401.361 2402.654 --- --- 2441 1.323 2440.352 2441.675 --- --- 2480 1.305 2479.361 2480.666 --- --- 3 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 4 2DH5_Ant1_2402 2DH5_Ant1_2441 5 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 6 3DH5_Ant1_2480 7 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.85707 2401.5822 2402.4392 --- --- 2441 0.86043 2440.5775 2441.4380 --- --- 2480 0.85515 2479.5799 2480.4350 --- --- 2DH5 Ant1 2402 1.1824 2401.4186 2402.6010 --- --- 2441 1.1935 2440.4140 2441.6075 --- --- 2480 1.1866 2479.4169 2480.6035 --- --- 3DH5 Ant1 2402 1.1951 2401.4098 2402.6049 --- --- 2441 1.1890 2440.4147 2441.6037 --- --- 2480 1.1836 2479.4196 2480.6032 --- --- 8 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 9 2DH5_Ant1_2402 2DH5_Ant1_2441 10 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 11 3DH5_Ant1_2480 12 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict DH5 Ant1 2402 -3.38 ≤20.97 PASS 2441 -3.42 ≤20.97 PASS 2480 -3.69 ≤20.97 PASS 2DH5 Ant1 2402 -0.74 ≤20.97 PASS 2441 -0.83 ≤20.97 PASS 2480 -1.01 ≤20.97 PASS 3DH5 Ant1 2402 -0.37 ≤20.97 PASS 2441 -0.50 ≤20.97 PASS 2480 -0.66 ≤20.97 PASS 13 Appendix D: Carrier frequency separation Test Result TestMode Antenna Freq(MHz) Result[MHz] Limit[MHz] Verdict DH5 Ant1 Hop 1.016 ≥0.954 PASS 2DH5 Ant1 Hop 1.062 ≥0.902 PASS 3DH5 Ant1 Hop 0.99 ≥0.882 PASS 14 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 15 16 Appendix E: Time of occupancy Test Result TestMode Antenna Freq(MHz) BurstWidth [ms] TotalHops [Num] Result[s] Limit[s] Verdict DH1 Ant1 Hop 0.407 319 0.13 ≤0.4 PASS DH3 Ant1 Hop 1.662 160 0.266 ≤0.4 PASS DH5 Ant1 Hop 2.911 107 0.311 ≤0.4 PASS 2DH1 Ant1 Hop 0.414 319 0.132 ≤0.4 PASS 2DH3 Ant1 Hop 1.668 160 0.267 ≤0.4 PASS 2DH5 Ant1 Hop 2.916 100 0.292 ≤0.4 PASS 3DH1 Ant1 Hop 0.415 317 0.132 ≤0.4 PASS 3DH3 Ant1 Hop 1.666 159 0.265 ≤0.4 PASS 3DH5 Ant1 Hop 2.917 89 0.26 ≤0.4 PASS 17 Test Graphs DH1_Ant1_Hop DH3_Ant1_Hop 18 DH5_Ant1_Hop 19 2DH1_Ant1_Hop 2DH3_Ant1_Hop 20 2DH5_Ant1_Hop 21 3DH1_Ant1_Hop 3DH3_Ant1_Hop 22 3DH5_Ant1_Hop 23 24 Appendix F: Number of hopping channels Test Result TestMode Antenna Freq(MHz) Result[Num] Limit[Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 3DH5 Ant1 Hop 79 ≥15 PASS 25 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 26 27 Appendix G: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 -4.08 -55.32 ≤-24.08 PASS High 2480 -4.30 -55.93 ≤-24.3 PASS Low Hop_2402 -5.29 -58.68 ≤-25.29 PASS High Hop_2480 -4.85 -56.84 ≤-24.85 PASS 2DH5 Ant1 Low 2402 -5.04 -57.73 ≤-25.04 PASS High 2480 -4.87 -56.05 ≤-24.87 PASS Low Hop_2402 -5.27 -57.79 ≤-25.27 PASS High Hop_2480 -6.60 -57.65 ≤-26.6 PASS 3DH5 Ant1 Low 2402 -4.73 -57.74 ≤-24.73 PASS High 2480 -4.56 -56.71 ≤-24.56 PASS Low Hop_2402 -5.41 -58.45 ≤-25.41 PASS High Hop_2480 -5.13 -57.51 ≤-25.13 PASS 28 Test Graphs DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 29 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 30 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 31 3DH5_Ant1_Low_2402 3DH5_Ant1_High_2480 32 3DH5_Ant1_Low_Hop_2402 3DH5_Ant1_High_Hop_2480 33 Appendix H: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 2402 Reference -4.56 -4.56 --- PASS 30~1000 -4.56 -68.91 ≤-24.56 PASS 1000~26500 -4.56 -45.49 ≤-24.56 PASS 2441 Reference -4.48 -4.48 --- PASS 30~1000 -4.48 -68.32 ≤-24.48 PASS 1000~26500 -4.48 -46.61 ≤-24.48 PASS 2480 Reference -3.93 -3.93 --- PASS 30~1000 -3.93 -68.31 ≤-23.93 PASS 1000~26500 -3.93 -46.26 ≤-23.93 PASS 2DH5 Ant1 2402 Reference -5.42 -5.42 --- PASS 30~1000 -5.42 -69.49 ≤-25.42 PASS 1000~26500 -5.42 -42.77 ≤-25.42 PASS 2441 Reference -5.18 -5.18 --- PASS 30~1000 -5.18 -69.19 ≤-25.18 PASS 1000~26500 -5.18 -46.54 ≤-25.18 PASS 2480 Reference -4.19 -4.19 --- PASS 30~1000 -4.19 -68.89 ≤-24.19 PASS 1000~26500 -4.19 -46.93 ≤-24.19 PASS 3DH5 Ant1 2402 Reference -6.39 -6.39 --- PASS 30~1000 -6.39 -66.25 ≤-26.39 PASS 1000~26500 -6.39 -46.85 ≤-26.39 PASS 2441 Reference -4.12 -4.12 --- PASS 30~1000 -4.12 -69.58 ≤-24.12 PASS 1000~26500 -4.12 -47.05 ≤-24.12 PASS 2480 Reference -6.76 -6.76 --- PASS 30~1000 -6.76 -69 ≤-26.76 PASS 1000~26500 -6.76 -45.14 ≤-26.76 PASS 34 Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 35 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 36 DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 37 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference
38 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference 39 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 40 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 41 3DH5_Ant1_2402_0~Reference 3DH5_Ant1_2402_30~1000 42 3DH5_Ant1_2402_1000~26500 3DH5_Ant1_2441_0~Reference 3DH5_Ant1_2441_30~1000 43 3DH5_Ant1_2441_1000~26500 3DH5_Ant1_2480_0~Reference 44 3DH5_Ant1_2480_30~1000 3DH5_Ant1_2480_1000~26500 45 Appendix I: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] DC [%] xFactor Limit Verdict DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 2DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.92 3.75 77.87 1.09 --- --- 3DH5 Ant1 2402 2.92 3.75 77.87 1.09 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.92 3.75 77.87 1.09 --- --- 46 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 47 2DH5_Ant1_2402 2DH5_Ant1_2441 48 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 49 3DH5_Ant1_2480 50 Appendix J: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict DH5 Ant1 Low 2402 AV 2310.000 -60.36 2.00 1.10 37.94 ≤54 PASS AV 2373.605 -58.94 2.00 1.10 39.36 ≤54 PASS AV 2390.000 -60.61 2.00 1.10 37.69 ≤54 PASS Peak 2310.000 -52.19 2.00 0.00 45.01 ≤74 PASS Peak 2356.595 -49.11 2.00 0.00 48.09 ≤74 PASS Peak 2390.000 -50.21 2.00 0.00 46.99 ≤74 PASS High 2480 AV 2483.500 -58.77 2.00 1.10 39.53 ≤54 PASS AV 2483.760 -58.33 2.00 1.10 39.97 ≤54 PASS AV 2500.000 -59.1 2.00 1.10 39.20 ≤54 PASS Peak 2483.500 -52 2.00 0.00 45.20 ≤74 PASS Peak 2491.680 -48.11 2.00 0.00 49.09 ≤74 PASS Peak 2500.000 -51.83 2.00 0.00 45.37 ≤74 PASS 2DH5 Ant1 Low 2402 AV 2310.000 -60.78 2.00 1.10 37.52 ≤54 PASS AV 2386.730 -58.92 2.00 1.10 39.38 ≤54 PASS AV 2390.000 -59.34 2.00 1.10 38.96 ≤54 PASS Peak 2310.000 -51.42 2.00 0.00 45.78 ≤74 PASS Peak 2383.790 -48.74 2.00 0.00 48.46 ≤74 PASS Peak 2390.000 -50.98 2.00 0.00 46.22 ≤74 PASS High 2480 AV 2483.500 -58.82 2.00 1.09 39.47 ≤54 PASS AV 2483.680 -58.56 2.00 1.09 39.73 ≤54 PASS AV 2500.000 -59.35 2.00 1.09 38.94 ≤54 PASS Peak 2483.500 -50.56 2.00 0.00 46.64 ≤74 PASS Peak 2493.040 -48.79 2.00 0.00 48.41 ≤74 PASS Peak 2500.000 -52.51 2.00 0.00 44.69 ≤74 PASS 3DH5 Ant1 Low 2402 AV 2310.000 -60.68 2.00 1.09 37.61 ≤54 PASS AV 2380.535 -59.06 2.00 1.09 39.23 ≤54 PASS AV 2390.000 -60.19 2.00 1.09 38.10 ≤54 PASS Peak 2310.000 -54.32 2.00 0.00 42.88 ≤74 PASS Peak 2388.935 -48.64 2.00 0.00 48.56 ≤74 PASS Peak 2390.000 -50.25 2.00 0.00 46.95 ≤74 PASS High 2480 AV 2483.500 -58.95 2.00 1.09 39.34 ≤54 PASS AV 2484.080 -58.45 2.00 1.09 39.84 ≤54 PASS AV 2500.000 -59.49 2.00 1.09 38.80 ≤54 PASS Peak 2483.500 -51.8 2.00 0.00 45.40 ≤74 PASS Peak 2484.560 -48.3 2.00 0.00 48.90 ≤74 PASS Peak 2500.000 -51.29 2.00 0.00 45.91 ≤74 PASS 51 Note: 1. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 52 Test Graphs DH5_Ant1_Low_2402_AV DH5_Ant1_Low_2402_Peak DH5_Ant1_High_2480_AV 53 DH5_Ant1_High_2480_Peak 2DH5_Ant1_Low_2402_AV 54 2DH5_Ant1_Low_2402_Peak 2DH5_Ant1_High_2480_AV 2DH5_Ant1_High_2480_Peak 55 3DH5_Ant1_Low_2402_AV 3DH5_Ant1_Low_2402_Peak 56 3DH5_Ant1_High_2480_AV 3DH5_Ant1_High_2480_Peak
1. Antenna Description: Antenna type Metal antenna Model MORTAL X5S Frequency range 2400-2500MHz, 5180-5240MHz, 5745-5825MHz Manufacturer Shenzhen Xinghe Video Communication Co., Ltd Address 2F,Bud F,Hongzhu Yongqi Technology Park, LezhujiaoVillage, Jiuwei Community,Hangcheng Street, Bao'an,District,Shenzhen, China ANT Peak Gain 0.73 dBi for 2400-2500MHz 1.53 dBi for 5180-5240MHz 1.23 dBi for 5745-5825MHz 2. Antenna Photo: 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz 5180MHz 5220MHz 5240MHz 5745MHz 5785MHz 5825MHz
FCC ID: 2BXL6-MORTALX5S Test Setup Photos of the EUT FCC ID: 2BXL6-MORTALX5S
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 900.00 µW |