Rev 1/26/2023 SMARTSELECT HOMETECH LIMITED Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 08-21-2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BXMR-MPH-33 [SMARTSELECT HOMETECH LIMITED] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [SMARTSELECT HOMETECH LIMITED] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name) Lemon feng Rev 1/26/2023 SMARTSELECT HOMETECH LIMITED Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 08-21-2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BXMR-MPH-33 [SMARTSELECT HOMETECH LIMITED] ce8rtifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Lemon feng
SMARTSELECT HOMETECH LIMITED U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: August 21, 2026 Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BXMR-MPH-33 SMARTSELECT HOMETECH LIMITED (“the applicant”) certifies that, as of the date of the filing of the application, CLF Import and Export Limited (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. CLF Import and Export Limited ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: CLF Import and Export Limited FRN: 0033489683 Address: 1312 17th Street #692, Denver, CO 80202, United States Signature: Contact Person: David Chen Tel: +1 949 254 2565 Email: [email protected] Applicant Company Name: SMARTSELECT HOMETECH LIMITED FRN: 0038762860 Address: UNIT 3A, 6/F., KAM HON IND, BUILDING, 8 WANG KWUN ROAD, KLN BAY, Hong Kong Signature: Contact Person: Lemon feng Tel: 18211307641 Email: [email protected]
SMARTSELECT HOMETECH LIMITED Date: August 21, 2026 Product Model Number: MPH-33 FCC ID: 2BXMR-MPH-33 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Lemon feng Contact Listed on FCC Wesbite Title: Manager Email: [email protected] Telephone: 18211307641 On behalf of: SMARTSELECT HOMETECH LIMITED
SMARTSELECT HOMETECH LIMITED Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 21, 2026 Subject; Request for Confidentiality FCC ID: 2BXMR-MPH-33 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Lemon feng Title: Manager
Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report Annex A. EUT External Photos Model: MPH-33 EUT View 1 EUT View 2 Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report EUT View 3 EUT View 4 Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report EUT View 5 EUT View 6 Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report EUT View 7
Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report Annex D. Label and Information FCC Label Sample Label Size:1.3cm*0.3cm FCC Label Specifications Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Where the EUT is constructed in two or more sections connected by wires and marketed together, the above statement is required to be affixed only to the main control unit. When the EUT is so small or for such use that it is not practicable to place the statement on it, the above information shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. FCC Label Location
Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report Annex B. EUT Internal Photos Model: MPH-33 EUT Internal View 1 EUT Internal View 2 Coil Antenna Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report EUT Internal View 3 EUT Internal View 4
Report No: SSP26070487-2 FCC Test Report Page 1 of 11 RF Exposure Report FCC ID: 2BXMR-MPH-33 Report No. : SSP26070487-2 Applicant : SMARTSELECT HOMETECH LIMITED Product Name : Magnetic Wireless Charging Phone Holder Model Name : MPH-33 Test Standard : FCC CFR 47 PART 1, 1.1310 Date of Issue : 2026-08-13 Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China; (Tel.:+86-755-23406590 website: www.zrlklab.com) This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd. Report No: SSP26070487-2 FCC Test Report Page 2 of 11 Test Report Basic Information Applicant..................................: SMARTSELECT HOMETECH LIMITED Address of Applicant...............: UNIT 3A, 6/F., KAM HON IND, BUILDING, 8 WANG KWUN ROAD, KLN BAY, Hong Kong Manufacturer..........................: Dongguan Jiamushi Electronics Co., Ltd Address of Manufacturer........: Room 201, Building 3, No. 3 Longxin 3rd Street, Huangjiang Town, Dongguan City, Guangdong Province, P.R.China Product Name.........................: 15W Wireless Charger Laptop Phone Holder Brand Name.............................: - Main Model..............................: MPH-33 Series Models..........................: - Test Standard..........................: FCC CFR 47 PART 1, 1.1310 KDB 680106 D01 Wireless Power Transfer v04 Date of Test .............................: 2026-07-24 to 2026-08-10 Test Result...............................: PASS Tested By ................................: (Coke Huang) Reviewed By............................: (Lorzix Luo) Authorized Signatory............: (Lahm Peng) Note : This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd.. All test data presented in this test report is only applicable to presented test sample. Report No: SSP26070487-2 FCC Test Report Page 3 of 11 CONTENTS 1. General Information ....................................................................................................................................................5 1.1 Product Information .............................................................................................................................................5 1.2 Test Setup Information..........................................................................................................................................6 1.3 Test Facilities ........................................................................................................................................................7 1.4 List of Measurement Instruments ..........................................................................................................................8 1.5 Measurement Uncertainty .....................................................................................................................................8 2. RF Exposure .................................................................................................................................................................9 2.1 Standard and Limit................................................................................................................................................9 2.2 Test Procedures ....................................................................................................................................................9 2.3 Test Data and Results .......................................................................................................................................... 10 Annex A. Test Photos ..................................................................................................................................................... 11 Report No: SSP26070487-2 FCC Test Report Page 4 of 11 Revision History Revision Issue Date Description Revised By V1.0 2026-08-13 Initial Release Lahm Peng Report No: SSP26070487-2 FCC Test Report Page 5 of 11 1. General Information 1.1 Product Information Product Name: 15W Wireless Charger Laptop Phone Holder Trade Name: - Test Model: MPH-33 Series Models: - Rated Voltage: Input: 5/2A, 9V/2A, 9V/3A Output: 5W, 7.5W, 10W, 15W (Wireless output) Power Adapter: - Battery: - Test Sample No: SSP26070487-1 Hardware Version: V1.0 Software Version: V1.0 Note 1: The test data is gathered from a production sample, provided by the manufacturer. Wireless Specification Wireless Standard: WPC (QI) Operating Frequency: 110.5kHz-205kHz Modulation: FSK Antenna Gain: 0dBi Type of Antenna: Coil Antenna Type of Device: Portable Device Mobile Device Report No: SSP26070487-2 FCC Test Report Page 6 of 11 1.2 Test Setup Information List of Test Modes Test Mode Description Remark TM1 Wireless charging 15W+adapter charging - TM2 Wireless charging 10W+adapter charging - TM3 Wireless charging 7.5W+adapter charging - TM4 Wireless charging 5W+adapter charging - Note1: All modes including full load, halfload and no-load have been tested, The report reflects data for the worst full load TM1 mode only. List and Details of Auxiliary Cable Description Length (cm) Shielded/Unshielded With/Without Ferrite - - - - - - - - List and Details of Auxiliary Equipment Description Manufacturer Model Serial Number Adapter CUKTECH AD1003 - Mobile phone Apple iPhone 16 HYG6PQMWK Report No: SSP26070487-2 FCC Test Report Page 7 of 11 1.3 Test Facilities Laboratory Name: Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China CNAS Laboratory No.: L18863 A2LA Certificate No.: 6983.01 FCC Registration No: 583813 ISED Registration No.: CN0164 Report No: SSP26070487-2 FCC Test Report Page 8 of 11 1.4 List of Measurement Instruments…
Text truncated - open the document above for the full version.
Report No: SSP26070487-1 FCC Test Report Page 1 of 23 FCC TEST REPORT FCC ID: 2BXMR-MPH-33 Report No. : SSP26070487-1 Applicant : SMARTSELECT HOMETECH LIMITED Product Name : Magnetic Wireless Charging Phone Holder Model Name : MPH-33 Test Standard : FCC Part 15 Subpart C Date of Issue : 2026-08-13 Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China; (Tel.:+86-755-23406590 website: www.zrlklab.com) This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd. Report No: SSP26070487-1 FCC Test Report Page 2 of 23 Test Report Basic Information Applicant..................................: SMARTSELECT HOMETECH LIMITED Address of Applicant...............: UNIT 3A, 6/F., KAM HON IND, BUILDING, 8 WANG KWUN ROAD, KLN BAY, Hong Kong Manufacturer..........................: Dongguan Jiamushi Electronics Co., Ltd Address of Manufacturer........: Room 201, Building 3, No. 3 Longxin 3rd Street, Huangjiang Town, Dongguan City, Guangdong Province, P.R.China Product Name.........................: 15W Wireless Charger Laptop Phone Holder Brand Name.............................: - Main Model..............................: MPH-33 Series Models..........................: - Test Standard..........................: FCC Part 15 Subpart C ANSI C63.4-2014 ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 Date of Test .............................: 2026-07-24 to 2026-08-10 Test Result...............................: PASS Tested By ................................: (Coke Huang) Reviewed By............................: (Lorzix Luo) Authorized Signatory............: (Lahm Peng) Note : This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd.. All test data presented in this test report is only applicable to presented test sample. Report No: SSP26070487-1 FCC Test Report Page 3 of 23 CONTENTS 1. General Information ....................................................................................................................................................5 1.1 Product Information .............................................................................................................................................5 1.2 Test Setup Information..........................................................................................................................................6 1.3 Compliance Standards ...........................................................................................................................................7 1.4 Test Facilities ........................................................................................................................................................7 1.5 List of Measurement Instruments ..........................................................................................................................8 1.6 Measurement Uncertainty .....................................................................................................................................8 2. Summary of Test Results .............................................................................................................................................9 3. Antenna Requirement ............................................................................................................................................... 10 3.1 Standard and Limit.............................................................................................................................................. 10 3.2 Test Result .......................................................................................................................................................... 10 4. Conducted Emissions ................................................................................................................................................ 11 4.1 Standard and Limit.............................................................................................................................................. 11 4.2 Test Procedure.................................................................................................................................................... 11 4.3 Test Data and Results .......................................................................................................................................... 12 5. Radiated Emissions ................................................................................................................................................... 15 5.1 Standard and Limit.............................................................................................................................................. 15 5.2 Test Procedure.................................................................................................................................................... 15 5.3 Test Data and Results .......................................................................................................................................... 17 6. Occupied Bandwidth ................................................................................................................................................. 22 6.1 Standard and Limit.............................................................................................................................................. 22 6.2 Test Procedure.................................................................................................................................................... 22 6.3 Test Data and Results .....................................................................................................…
Text truncated - open the document above for the full version.
Shenzhen Sanshengchu Electronic Technology Co., Ltd. 承 認 書 客 戶: CUSTOMER: Shenzhen Weirida Electronics Co., Ltd. 客 戶 料 號: CUST P/N: VRD-A0967 三盛创料 號: FINE P/N: G43.5-6.3uH Single coil 0.08*24P*2P*10TS 産 品 型 號: DESC: Φ43.5MMX5.3MMX0.8MM 日 期: DATE: 2024.09.06 版 本: Version: A.0 擬制 PREPARED BY 審核 CHECKED BY 批准 APPROVED BY 客戶承認 CUSTOMER APPROVE Guo Liu An Shuaiyin An Shuaiyin Shenzhen Sanshengchuang Technology Co., Ltd. Factory Address: Building 2, 2nd Floor, No. 19, Daoli Road, Yutou Community, Yutang Street, Guangming District, Shenzhen City 版本變更履歷 Version Change History 版本 Rev. 變 更 前 Before Change 變 更 後 After Change 更 改 日 期 Change Date 批 准 Approved By A.0 New release ---- 2024.09.06 An Shuaiyin SPECIFICATION 産 品 型 號: DESC Φ20.5x40-6.3uH-0.08x24P*2P-20mm 版本 Rev:A.0 客戶CUST: Verida 客户料号CUST P/N: VRD-A0659-B 一、尺寸DIMENSION:(mm) 二、原理图SCHEMATIC DIAGRAM: A 40.0±1.0 B 20.5±0.5 D 20±2 E 3±1 F 43.5±0.5 G 8.0±1.0 H 1.8 ±0.2 I 5.0±0.3 M 7.0±1.0 J 42.5±1 K 3.0±1 Note: 1. Cross-line method; 2. Apply 8mm (ref) wide heat-resistant adhesive tape at the exit position for 1-2 times; 1.3. The coil is attached to the circular hard magnetic sheet with slots. The size of the magnetic sheet is 43.5 ± 0.5mm, the inner hole is 5.3mm, and the thickness is 0.8 ± 0.1mm. 三、绕线参数Winding Specification: 序号 NO. 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 Winding Direction 1 S F Hot air line 0.08*24P 10Ts CCW 四、电气特性ELECTRICAL CHARACTERISTICS: 温度TEMPERATURE:25±10°C, 湿度RELATIVE HUMIDITY:65±20% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TEST FREQUENCY 测试仪器 TEST EQUIPMENTS 1 IND. S-F 4.0uH ±10% Single coil 100KHz/1.0V LCZ METER 1062B 2 IND. S-F 6.3uH ±10% Add magnetic chips 100KHz/1.0V LCZ METER 1062B 3 DCR S-F ≤98mΩ 100KHz/1.0V LCZ METER 502B 4 Q S-F ≧40 100KHz/1.0V LCZ METER 502B 擬制/日期PREPARED BY/DATE 審核/日期CHECKED BY/DATE Guo Liu 2024.09.06 An Shuaiyin 2024.09.06
Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report Annex C. Test Photos Conducted Emission Test View 1 Radiated Emission Test View 1 Report No: SSP26070487-1 FCC ID: 2BXMR-MPH-33 Annex of Test Report Radiated Emission Test View 2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1105 MHz - 0.205 MHz | - |