Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Voiceremotecontrolmanual UserManual 1.ProductIntroduction ThisisaBLElow-powerBluetoothvoiceremotecontrol,compatiblewith Android-TVsmarttelevisionsandTVboxes.ItsupportsBluetoothpairing,voice search,one-clickquick-accessstreaminghot-keysandfull-functionoperation.No line-of-sightalignmentisrequired.YoucancontrolyourTVfromwide-angleand long-distancepositions. ⚠ImportantNotice:ThisremoteisBluetooth-only,noIRinfraredfunction.Itcan NOTworkwithtraditionalinfrared-onlytelevisions. 2.TechnicalSpecifications ItemParameter CommunicationBLEBluetooth5.0(Low-Energy) PowerSupply2×AAABatteries(DC3V) ControlDistance≥10meters(openspacewithoutobstacles) Functions VoiceSearch,ChannelSelection,Navigation,Media Control,APPShortcutKeys Operating Temperature -10°C~+45°C 3.ButtonFunctionDescription Left-sideButtons 1.VoiceKey:Pressandholdtospeak,releasetosendvoicecommand 2.NumericKeys(0-9):Inputchannelnumbersordigits 3.-/--Key:Double-digitchannelswitch 4.RecallKey:Jumpbacktopreviouschannel 5.Netflix/YouTube/Live-TVHot-keys:One-taplaunchcorrespondingstreaming applications 6.PowerKey:TurnTVon/enterstandbymode MiddleNavigationArea Up/Down/Left/Right:Moveon-screencursor OKKey:Confirmselection ReturnKey:Gobacktopreviousmenu HomeKey:ReturntoTVmainhomescreen Right-sideFunctionButtons MenuKey:OpenTVsystemsettingsmenu Volume+/Volume-:Adjustspeakervolume CH+/CH-:SwitchTVchannels ColorButtons(Blue/Yellow/Green/Red):Expandableshortcutfunctions,follow on-screenprompts 4.BluetoothPairingSteps(Mustpairforfirst-timeuse) 1.Openthebatterycoverandinsert2×AAAbatteries,followpolaritymarksinsidethe compartment. 2.PoweronyourAndroidTV,gotoSettings>Bluetooth,turnonBluetoothandstart searchingnewdevices. 3.PressandholdHome+Returnbuttonstogetherfor5-8seconds.Theremotewillenter pairingmode. 4.SelecttheremotedevicenameonyourTV’sBluetoothlistandcompleteconnection. 5.Onceconnectedsuccessfully,allbuttonswillworknormally. Troubleshootingforfailedpairing:Removebatteries,wait 10seconds,reinstallbatteriesandrestartpairing procedure. 5.HowtoUseVoiceFunction 1.MakesuretheremotehasbeensuccessfullyconnectedoverBluetooth.Voicewillnot workunderinfraredconnection. 2.PressandholdtheVoicebutton,speakclearlytowardtheremotemicrophone. Examplevoicecommands:OpenYouTube,Playmovie,Setvolume to20,SearchAndyLauvideos 3.Releasethevoicebuttonafteryoufinishspeaking,theTVwillexecuteyourcommand. 6.TroubleshootingGuide ProblemSolution Allbuttonsno response 1.CheckAAAbatterypower&polarity;2.Re-pair Bluetooth;3.RebootTV Buttonswork,but voicefails 1.VerifyBluetoothconnectionstatus;2.Confirm yourTVsupportsbuilt-invoiceassistant;3. EnablemicrophonepermissiononTV Intermittent/ unstablecontrol 1.Keepcloserdistance,stayawayfrom2.4GHzWi-Fi routers(signalinterference);2.Replacewith brand-newbatteries APPshortcutkeyno reaction Correspondingstreamingapplicationisnot installedonyourTV,pleasedownloadandinstallthe APPmanually. 7.SafetyPrecautions 1.DoNOTmixoldandnewbatteriesordifferentbatterybrands.Removebatteriesifyou willnotusetheremoteforalongtimetoavoidbatteryleakageandcircuitcorrosion. 2.Donotdrop,submergeinwater,orstorethisremoteunderhigh-temperature&humid environment. 3.ThisremoteonlyworksforBLE-Bluetooth-enabledAndroid-TVdevices,non-Bluetooth TVsarenotcompatible. OuterBoxQuick-StartGuide QuickPairing 1.Insert2×AAAbatteries 2.TurnonTVBluetooth&startsearch 3.Hold【Home+Return】5-8sforpairing
FCCID:2BXYL-XMRM-P3 ExternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2BXYL-XMRM-P3 Fig.3 Fig.4 FCCID:2BXYL-XMRM-P3 Fig.5 Fig.6
FCCID:2BXYL-XMRM-P3 labelandlocation Fig.1 FCCID:2BXYL-XMRM-P3 REMOTECONTROL XMRM-P3 Input:DC3.0V TianchangJunlinTradingCO.,LTD
FCCID:2BXYL-XMRM-P3 InternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2BXYL-XMRM-P3 Fig.3 Fig.4 Bluetooth Antenna FCCID:2BXYL-XMRM-P3 Fig.5
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. ..................... : FCC ID. ........................................... : CTA26082400102 2BXYL-XMRM-P3 Compiled by ( position+printed name+signature) .. : File administrators Zoey Cao Supervised by ( position+printed name+signature) .. : Project Engineer Ace Chai Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Aug. 28, 2026 Testing Laboratory Name ............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................. : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ........................... : Tianchang Junlin Trading CO.,LTD Address ............................................. : Limin Street,Jinji Town,Tianchang City,Anhui Province,China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : REMOTE CONTROL Trade Mark ........................................ N/A Manufacturer ..................................... : Tianchang Junlin Trading CO.,LTD Model/Type reference ....................... : XMRM-P3 Listed Models ................................... : Refer to Page 2 Ratings .............................................. : Battery: DC 3.0V Result ................................................ : PASS Report No.: CTA26082400102 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : REMOTE CONTROL Model /Type : XMRM-P3 Listed Models : BN59-01310A, AA59-00706A, RC901V, RC902V, KM2, MR20GA, MR19BA, MR650A,MR600, MR18BA, MR21GA, MR21GC, MR22GA, XRT- 136, XRT500, RMF-TX200P,RMT-TX100A, N2QAYB000479, AKB75095312, CT-8053, EN3C39, EN2B27, ERF3I69H,RM-F01, RC43140, RC1900, RC802N, BRC0884402, HTR-A18E, L5B83H, XMRM- 00A,RC-G009, RG66A1, RM-B119P, RMT-AH300U, N2QAYC000098, NB677, AXD7692,RC024SR, RC-1168, RAV25, RC-879M, MR23GA, ERF3M90H, RMF-TX500P,RMF-TX800P, RMF-TX310P, NH800UP, HP04, HP05, HP06, HP09, DP01, DP03, TP02TP03, AM10, BP01, HP02, HP03, TP04, TP06, TP09, DP04,TP05, PH01, AM04, AM05,AM09, AM06, AM07, AM08, HP00, HP01, AM11, TP00, TP01, RMT-AH412U,GB326WJSA, GB345WJSA, GB346WJSA, RMC0133, CT-8536, HTR-U27E, G9N9N, BN59-01385A ,BN59-01432A,CT-8556,CT-8557,MR25GA, MR24GA, SKY,XMRM-00A,XMRM-010,XMRM-019,XMRM-ML,XMRM-P3,XMRM- 006,RM-F04,RC813A,RC833A,RC901V, RC902V,ERF3S90H,RMF- TX200E, RMF-TX300U,RMF-TX920U,RMF-TX810U,EN2BO27H, RC43141, N2QAYB000830, RC2101,RC201,BRC0884305, BRC0884402, BRC0884301, BRC0984501,HTR-U29A,CT-8561,H.265, V3,V5,RM- ED049, GA857WJSA,AK59-00146A,HS-7708,N2QAYB001059, SX RCU 03, SF8008,N2QAYB000715,BN59-01315N,EN2BC27, N2QAYA000127, RMT-JR01,BN59-01301A,BN59-01180A,SE-R0295, RMT-B119A, XRT270, XRT260,RMT-TX102U,CT-90325,RM-C3227,BN59-01301A, EN2A27ST,MAG254,EC40V2FA Model difference : The PCB board, circuit, structure and internal of these models are the same, only model number and colour are different for these model. So the tests were performed on model XMRM-P3 and the test results for the main test model can cover the listed models. Applicant : Tianchang Junlin Trading CO.,LTD Address : Limin Street,Jinji Town,Tianchang City,Anhui Province,China Manufacturer : Tianchang Junlin Trading CO.,LTD Address : Limin Street,Jinji Town,Tianchang City,Anhui Province,China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26082400102 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................... 4 2 S U M M A R Y .............................................................. 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Special Accessories 5 2.4 Modifications 5 3 T E S T E N V I R O N M E N T ................................................ 6 3.1 Address of the test laboratory 6 3.2 Test Facility 6 3.3 Statement of the measurement uncertainty 6 4 T E S T L I M I T ............................................................ 7 4.1 Requirement 7 4.2 Conducted Power Results 7 4.3 Manufacturing tolerance 7 4.4 Evaluation Result 8 4.5 Simultaneous Transmission for SAR Exclusion 8 5 C O N C L U S I O N .......................................................... 8 Report No.: CTA26082400102 Page 4 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.c…
Text truncated - open the document above for the full version.
Antennaspec FCCID:2BXYL-XMRM-P3 1.AntennaDescription: AntennatypePCBAntenna ModelYT002 Frequencyrange2400-2500MHz ManufacturerShenzhenTangshangTechnologyCo.,LTD Address4018,Building34,ChentianIndustrialZone,Chentian Community,XixiangStreet,BaoanDistrict,Shenzhen 2.AntennaPhoto: 3.AntennaEfficiencyandGain: Frequency(MHz)PeakGain(dBi)Effciency(%) 24001.5047.05 24501.4845.82 25001.2244.92 4.RadiationPattern
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ........................................ : CTA26082400101 2BXYL-XMRM-P3 Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Aug. 28, 2026 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ...........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: Tianchang Junlin Trading CO.,LTD Address ...........................................: Limin Street,Jinji Town,Tianchang City,Anhui Province,China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : REMOTE CONTROL Trade Mark ......................................: N/A Manufacturer ...................................: Tianchang Junlin Trading CO.,LTD Model/Type reference .....................: XMRM-P3 Listed Models ..................................: Refer to Page 2 Modulation .....................................: GFSK Frequency .......................................: From 2402MHz to 2480MHz Ratings ............................................: Battery: DC 3.0V Result ..............................................: PASS Report No.: CTA26082400101 Page 2 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : REMOTE CONTROL Model /Type : XMRM-P3 Listed Models : BN59-01310A, AA59-00706A, RC901V, RC902V, KM2, MR20GA, MR19BA, MR650A,MR600, MR18BA, MR21GA, MR21GC, MR22GA, XRT- 136, XRT500, RMF-TX200P,RMT-TX100A, N2QAYB000479, AKB75095312, CT-8053, EN3C39, EN2B27, ERF3I69H,RM-F01, RC43140, RC1900, RC802N, BRC0884402, HTR-A18E, L5B83H, XMRM- 00A,RC-G009, RG66A1, RM-B119P, RMT-AH300U, N2QAYC000098, NB677, AXD7692,RC024SR, RC-1168, RAV25, RC-879M, MR23GA, ERF3M90H, RMF-TX500P,RMF-TX800P, RMF-TX310P, NH800UP, HP04, HP05, HP06, HP09, DP01, DP03, TP02TP03, AM10, BP01, HP02, HP03, TP04, TP06, TP09, DP04,TP05, PH01, AM04, AM05,AM09, AM06, AM07, AM08, HP00, HP01, AM11, TP00, TP01, RMT-AH412U,GB326WJSA, GB345WJSA, GB346WJSA, RMC0133, CT-8536, HTR-U27E, G9N9N, BN59-01385A ,BN59-01432A,CT-8556,CT-8557,MR25GA, MR24GA, SKY,XMRM-00A,XMRM-010,XMRM-019,XMRM-ML,XMRM-P3,XMRM- 006,RM-F04,RC813A,RC833A,RC901V,RC902V,ERF3S90H,RMF- TX200E, RMF-TX300U,RMF-TX920U,RMF-TX810U,EN2BO27H, RC43141, N2QAYB000830,RC2101,RC201,BRC0884305, BRC0884402, BRC0884301,BRC0984501,HTR-U29A,CT-8561,H.265, V3,V5,RM-ED049, GA857WJSA,AK59-00146A,HS-7708,N2QAYB001059, SX RCU 03, SF8008,N2QAYB000715,BN59-01315N,EN2BC27, N2QAYA000127, RMT- JR01,BN59-01301A,BN59-01180A,SE-R0295, RMT-B119A, XRT270, XRT260,RMT-TX102U,CT-90325,RM-C3227,BN59-01301A, EN2A27ST,MAG254,EC40V2FA Model difference : The PCB board, circuit, structure and internal of these models are the same, only model number and colour are different for these model. So the tests were performed on model XMRM-P3 and the test results for the main test model can cover the listed models. Applicant : Tianchang Junlin Trading CO.,LTD Address : Limin Street,Jinji Town,Tianchang City,Anhui Province,China Manufacturer : Tianchang Junlin Trading CO.,LTD Address : Limin Street,Jinji Town,Tianchang City,Anhui Province,China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26082400101 Page 3 of 31 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description* .......................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration ..................…
Text truncated - open the document above for the full version.
1 FCC Appendix RF Test Data for BLE FCC ID : 2BXYL-XMRM-P3 Company : Tianchang Junlin Trading CO.,LTD EUT : REMOTE CONTROL Model Number : XMRM-P3 Report No. : CTA26082400101 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result Test Mode Antenna Freq(MHz) DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.632 2401.704 2402.336 0.5 PASS 2440 0.640 2439.696 2440.336 0.5 PASS 2480 0.644 2479.696 2480.340 0.5 PASS 3 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 4 5 Appendix B: Occupied Channel Bandwidth Test Result Test Mode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0052 2401.5196 2402.5248 --- --- 2440 1.0118 2439.5178 2440.5296 --- --- 2480 1.0182 2479.5143 2480.5325 --- --- 6 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 7 8 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Power[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -3.51 ≤30 PASS 2440 -3.52 ≤30 PASS 2480 -3.78 ≤30 PASS 9 Appendix D: Maximum power spectral density Test Result Test Mode Antenna Freq(MHz) Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -19.33 ≤8.00 PASS 2440 -19.27 ≤8.00 PASS 2480 -19.57 ≤8.00 PASS 10 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 11 12 Appendix E: Band edge measurements Test Result Test Mode Antenna ChName Freq(MHz) RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 -3.88 -54.27 ≤-23.88 PASS High 2480 -4.44 -55.98 ≤-24.44 PASS 13 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 14 Appendix F: Conducted Spurious Emission Test Result Test Mode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -3.69 -3.69 --- PASS 30~1000 -3.69 -67.78 ≤-23.69 PASS 1000~26500 -3.69 -45.9 ≤-23.69 PASS 2440 Reference -3.65 -3.65 --- PASS 30~1000 -3.65 -68.4 ≤-23.65 PASS 1000~26500 -3.65 -46.2 ≤-23.65 PASS 2480 Reference -5.87 -5.87 --- PASS 30~1000 -5.87 -68.52 ≤-25.87 PASS 1000~26500 -5.87 -46.59 ≤-25.87 PASS 15 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 16 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 17 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 18 BLE_1M_Ant1_2480_1000~26500 19 Appendix G: Duty Cycle Test Result Test Mode Antenna Freq(MHz) ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.41 0.62 0.6613 66.13 1.80 --- --- 2440 0.41 0.62 0.6613 66.13 1.80 --- --- 2480 0.41 0.62 0.6613 66.13 1.80 --- --- 20 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 21 22 Appendix H: Emissions in Restricted Bands Test Result Test Mode Antenn a ChNam e Freq(MH z) Detect or Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict BLE_1M Ant1 Low 2402 AV 2310.000 -60.14 2.00 1.80 38.86 ≤54 PASS AV 2372.555 -59.36 2.00 1.80 39.64 ≤54 PASS AV 2390.000 -60.34 2.00 1.80 38.66 ≤54 PASS Peak 2310.000 -53.01 2.00 0.00 44.19 ≤74 PASS Peak 2381.270 -49.65 2.00 0.00 47.55 ≤74 PASS Peak 2390.000 -52.73 2.00 0.00 44.47 ≤74 PASS High 2480 AV 2483.500 -58.93 2.00 1.80 40.07 ≤54 PASS AV 2484.400 -58.4 2.00 1.80 40.60 ≤54 PASS AV 2500.000 -59.41 2.00 1.80 39.59 ≤54 PASS Peak 2483.500 -49.93 2.00 0.00 47.27 ≤74 PASS Peak 2483.760 -49.29 2.00 0.00 47.91 ≤74 PASS Peak 2500.000 -51.67 2.00 0.00 45.53 ≤74 PASS Note: 1. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 23 Test Graphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV 24 BLE_1M_Ant1_High_2480_Peak
FCCID:2BXYL-XMRM-P3 TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 FCCID:2BXYL-XMRM-P3 TestSetupPhoto(s)ofRFMeasurement Fig.3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 400.00 µW |