Object: Date Issued: Page 1 of 3 D750V3 β SN: 1161 10/13/2025 Certification of Calibration Object D750V3 β SN: 1161 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extension Calibration date: 10/13/2025 Description: SAR Validation Dipole at 750 MHz. Calibration Equipment used: Measurement Uncertainty = Β±23% (k=2) Name Function Signature Calibrated By: ThuyTram Pham Test Engineer Approved By: Greg Snyder Executive VP of Operations, Regulatory Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent N5182A MXG Vector Signal Generator 5/30/2025 Annual 5/30/2026 MY48180366 Amplifier Research 15S1G6 Amplifier CBT N/A CBT 343971 Anritsu ML2495A Power Meter 7/3/2025 Annual 7/3/2026 1039008 Anritsu MA24106A USB Power Sensor 5/29/2025 Annual 5/29/2026 1344545 TERMOPRODUKT DT-1 Digital Thermometer 10/22/2024 Annual 10/22/2025 740621 Control Company 4052 Long Stem Thermometer 2/27/2024 Biennial 2/27/2026 240174346 MCL BW-N6W5+ 6dB Attenuator CBT N/A CBT 1139 MiniCircuits SLP-2400+ Low Pass Filter CBT N/A CBT R8979500903 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBT N/A CBT N/A Narda 4772-3 Attenuator (3dB) CBT N/A CBT 9406 Huber + Suhner 74Z-0-0-21 Torque Wrench 10/17/2023 Biennial 10/17/2025 16476 Mini-Circuits ZHDC-16-63-S+ Coupler CBT N/A CBT N/A Rohde & Schwarz ZNB40 Vector Network Analyzer 2/20/2025 Annual 2/20/2026 101412 SPEAG DAK-3.5 Dielectric Assessment Kit 10/15/2024 Annual 10/15/2025 1091 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 2/1/2024 Triennial 2/1/2027 MY53401181 SPEAG EX3DV4 SAR Probe 4/7/2025 Annual 4/7/2026 7659 SPEAG DAE4 Dasy Data Acquisition Electronics 4/10/2025 Annual 4/10/2026 1272 ELEMENT MATERIALS TECHNOLOGY (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com ThuyTram Pham Object: Date Issued: Page 2 of 3 D750V3 β SN: 1161 10/13/2025 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ξ© from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 2-year calibration period from the calibration date: Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Head (1g) W/kg @ 23.0 dBm Measured Head SAR (1g) W/kg @ 23.0 dBm Deviation 1g (%) Certificate SAR Target Head (10g) W/kg @ 23.0 dBm Measured Head SAR (10g) W/kg @ 23.0 dBm Deviation 10g (%) Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%) PASS/FAIL 10/7/2024 10/13/2025 1.037 1.67 1.63 -2.51% 1.08 1.11 2.59% 54.3 55.6 1.3 -2.2 -2 0.2 -26.8 -24.7 7.70% PASS Object: Date Issued: Page 3 of 3 D750V3 β SN: 1161 10/13/2025 Impedance & Return-Loss Measurement Plot for Head TSL SRS 03/13/25 Object: Date Issued: Page 1 of 3 D835V2 β SN: 4d133 03/10/2025 Certification of Calibration Object D835V2 β SN: 4d133 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extension Calibration date: 03/10/2025 Description: SAR Validation Dipole at 835 MHz. Calibration Equipment used: Measurement Uncertainty = Β±23% (k=2) Name Function Signature Calibrated By: Tho Tong Test Engineer Approved By: Greg Snyder Executive VP of Operations, Regulatory Manufacturer Model Description Cal Date Cal Interval Ca l Due Serial Number Agilent N5182A MXG Vector Signal Generator 3/15/2024Annual 3/15/2025MY47420651 Amplifier Research 15S1G6 Amplifier CBTN/A CBT343971 Anritsu MA24106A USB Power Sensor 3/14/2024Annual 3/14/20251349513 Control Company 4040Digital Thermometer3/27/2023Biennial 3/27/2025230208311 Control Company 4052Long Stem Thermometer 2/27/2024Biennial 2/27/2026240171059 MCL BW-N6W5+ 6dB Attenuator CBTN/A CBT1139 MiniCircuits SLP-2400+ Low Pass Filter CBTN/A CBTR8979500903 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBTN/A CBTN/A Narda 4772-3 Attenuator (3dB) CBTN/A CBT9406 Huber + Suhner74Z-0-0-21Torque Wrench 10/17/2023Biennial 10/17/202516476 Mini-CircuitsZHDC-16-63-S+Coupler CBTN/A CBTN/A Rohde & Schwarz ZNB40Vector Network Analyzer 2/20/2025Annual 2/20/2026101412 SPEAG DAK-3.5 Dielectric Assessment Kit 10/15/2024Annual 10/15/20251091 Keysight Technologies85033EStandard Mechanical Calibration Kit (DC to 9GHz, 3.5mm)2/1/2024Triennial2/1/2027MY53401181 SPEAGEX3DV 4SAR Probe5/10/2024Annual5/10/20253914 SPEAG DAE4 Dasy Data Acquisition Electronics 5/8/2024Annual5/8/2025728 ELEMENT MATERIALS TECHNOLOGY (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com Object: Date Issued: Page 2 of 3 D835V2 β SN: 4d133 03/10/2025 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of imβ¦
Text truncated - open the document above for the full version.
Object: Date Issued: Page 1 of 3 D2300V2 β SN: 1116 07/10/2025 Certification of Calibration Object D2300V2 β SN: 1116 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extension Calibration date: 07/10/2025 Description: SAR Validation Dipole at 2300 MHz. Calibration Equipment used: Measurement Uncertainty = Β±23% (k=2) Name Function Signature Calibrated By: Tho Tong Test Engineer Approved By: Greg Snyder Executive VP of Operations, Regulatory Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent N5182A MXG Vector Signal Generator 12/5/2024 Annual 12/5/2025 US46240505 Amplifier Research 15S1G6 Amplifier CBT N/A CBT 343971 Anritsu MA24106A USB Power Sensor 5/29/2025 Annual 5/29/2026 1344545 TERMOPRODUKT DT-1 Digital Thermometer 10/22/2024 Biennial 10/22/2025 740621 Control Company 4052 Long Stem Thermometer 2/27/2024 Biennial 2/27/2026 240174346 MCL BW-N6W5+ 6dB Attenuator CBT N/A CBT 1139 MiniCircuits SLP-2400+ Low Pass Filter CBT N/A CBT R8979500903 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBT N/A CBT N/A Narda 4772-3 Attenuator (3dB) CBT N/A CBT 9406 Huber + Suhner 74Z-0-0-21 Torque Wrench 10/17/2023 Biennial 10/17/2025 16476 Mini-Circuits ZHDC-16-63-S+ Coupler CBT N/A CBT N/A Rohde & Schwarz ZNB40 Vector Network Analyzer 2/20/2025 Annual 2/20/2026 101412 SPEAG DAK-3.5 Dielectric Assessment Kit 10/15/2024 Annual 10/15/2025 1091 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 2/1/2024 Triennial 2/1/2027 MY53401181 SPEAG EX3DV4 SAR Probe 12/5/2024 Annual 12/5/2025 7410 SPEAG DAE4 Dasy Data Acquisition Electronics 12/4/2024 Annual 12/4/2025 1213 ELEMENT MATERIALS TECHNOLOGY (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com Tho Tong Object: Date Issued: Page 2 of 3 D2300V2 β SN: 1116 07/10/2025 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ξ© from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 2-year calibration period from the calibration date: Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Head (1g) W/kg @ 20.0 dBm Measured Head SAR (1g) W/kg @ 20.0 dBm Deviation 1g (%) Certificate SAR Target Head (10g) W/kg @ 20.0 dBm Measured Head SAR (10g) W/kg @ 20.0 dBm Deviation 10g (%) Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%) PASS/FAIL 6/14/2024 7/10/2025 1.17 4.92 4.99 1.42% 2.39 2.39 0.00% 49.7 48.9 0.8 -2.9 -1.4 1.5 -30.6 -35.8 -17.10% PASS Object: Date Issued: Page 3 of 3 D2300V2 β SN: 1116 07/10/2025 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: Page 1 of 3 D2450V2 β SN: 719 08/07/2025 Certification of Calibration Object D2450V2 β SN: 719 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extension Calibration date: 08/07/2025 Description: SAR Validation Dipole at 2450 MHz. Calibration Equipment used: Measurement Uncertainty = Β±23% (k=2) Name Function Signature Calibrated By: Bizu Baldinazzo Test Engineer Approved By: Greg Snyder Executive VP of Operations, Regulatory Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Anritsu ML2496A Power Meter 6/27/2025 Annual 6/27/2026 1840005 Agilent N5182A MXG Vector Signal Generator 8/1/2025 Annual 8/1/2026 MY47420651 Amplifier Research 15S1G6 Amplifier CBT N/A CBT 343971 Anritsu MA24106A USB Power Sensor 5/29/2025 Annual 5/29/2026 1349511 TERMOPRODUKT DT-1 Digital Thermometer 10/22/2024 Annual 10/22/2025 740621 Control Company 4052 Long Stem Thermometer 2/27/2024 Biennial 2/27/2026 240174346 MCL BW-N6W5+ 6dB Attenuator CBT N/A CBT 1139 MiniCircuits SLP-2400+ Low Pass Filter CBT N/A CBT R8979500903 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBT N/A CBT N/A Narda 4772-3 Attenuator (3dB) CBT N/A CBT 9406 Huber + Suhner 74Z-0-0-21 Torque Wrench 10/17/2023 Biennial 10/17/2025 16476 Mini-Circuits ZHDC-16-63-S+ Coupler CBT N/A CBT N/A Rohde & Schwarz ZNB40 Vector Network Analyzer 2/20/2025 Annual 2/20/2026 101412 SPEAG DAK-3.5 Dielectric Assessment Kit 10/15/2024 Annual 10/15/2025 1091 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 2/1/2024 Triennial 2/1/2027 MY53401181 SPEAG EX3DV4 SAR Probe 12/5/2024 Annual 12/5/2025 7410 SPEAG DAE4 Dasy Data Acquisition Electronics 12/4/2024 Annual 12/4/2025 1213 ELEMENT MATERIALS TECHNOLOGY (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com Bizu Baldinazzo Object: Date Issued: Page 2 of 3 D2450V2 β SN: 719 08/07/2025 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement.β¦
Text truncated - open the document above for the full version.
FCC ID: A3LSMF776U RF EXPOSURE PART 1 TEST REPORT Approved by: Technical Manager DUT Type: Portable Handset This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX C A P P E N D I X C : P R O B E A N D D I P O L E C A L I B R A T I O N C E R T I F I C A T E S Object: Date Issued: Page 1 of 3 D1750V2 β SN: 1150 11/07/2025 Certification of Calibration Object D1750V2 β SN: 1150 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extension Calibration date: 11/07/2025 Description: SAR Validation Dipole at 1750 MHz. Calibration Equipment used: Measurement Uncertainty = Β±23% (k=2) Name Function Signature Calibrated By: ThuyTram Pham Test Engineer Approved By: Greg Snyder Executive VP of Operations, Regulatory Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent N5182A MXG Vector Signal Generator 8/1/2025 Annual 8/1/2026 MY47420651 Amplifier Research 15S1G6 Amplifier CBT N/A CBT 343971 Anritsu ML2495A Power Meter 7/3/2025 Annual 7/3/2026 1039008 Anritsu MA24106A USB Power Sensor 5/29/2025 Annual 5/29/2026 1344545 Control Company 4052 Long Stem Thermometer 2/27/2024 Biennial 2/27/2026 240174346 MCL BW-N6W5+ 6dB Attenuator CBT N/A CBT 1139 MiniCircuits SLP-2400+ Low Pass Filter CBT N/A CBT R8979500903 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBT N/A CBT N/A Narda 4772-3 Attenuator (3dB) CBT N/A CBT 9406 Huber + Suhner 8710-1765 Torque Wrench 4/2/2024 Biennial 4/2/2026 8210000633 Mini-Circuits ZHDC-16-63-S+ Coupler CBT N/A CBT N/A Rohde & Schwarz ZNB40 Vector Network Analyzer 2/20/2025 Annual 2/20/2026 101412 SPEAG DAK-3.5 Dielectric Assessment Kit 5/12/2025 Annual 5/12/2026 1070 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 2/1/2024 Triennial 2/1/2027 MY53401181 SPEAG EX3DV4 SAR Probe 1/7/2025 Annual 1/7/2026 7713 SPEAG DAE4 Dasy Data Acquisition Electronics 1/13/2025 Annual 1/13/2026 1530 ELEMENT MATERIALS TECHNOLOGY (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com ThuyTram Pham Object: Date Issued: Page 2 of 3 D1750V2 β SN: 1150 11/07/2025 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ξ© from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 2-year calibration period from the calibration date: Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Head (1g) W/kg @ 20.0 dBm Measured Head SAR (1g) W/kg @ 20.0 dBm Deviation 1g (%) Certificate SAR Target Head (10g) W/kg @ 20.0 dBm Measured Head SAR (10g) W/kg @ 20.0 dBm Deviation 10g (%) Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%) PASS/FAIL 11/7/2024 11/7/2025 1.218 3.64 3.76 3.30% 1.94 2.03 4.64% 50 50.8 0.8 1 1.2 0.2 -40.3 -40.2 0.30% PASS Object: Date Issued: Page 3 of 3 D1750V2 β SN: 1150 11/07/2025 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: Page 1 of 3 D1750V2 β SN: 1148 01/13/2026 Certification of Calibration Object D1750V2 β SN: 1148 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extension Calibration date: 01/13/2026 Description: SAR Validation Dipole at 1750 MHz Calibration Equipment used: Measurement Uncertainty = Β±23% (k=2) Name Function Signature Calibrated By: ThuyTram Pham Test Engineer Approved By: Greg Snyder Executive VP of Operations, Regulatory Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent N5182A MXG Vector Signal Generator 8/1/2025Annual 8/1/2026MY47420651 Amplifier Research 15S1G6 Amplifier CBTN/A CBT0343971 AnritsuML2496A Power Meter 8/21/2025Annual8/21/20261138001 AnritsuMA24106AUSB Power Sensor5/29/2025Annual5/29/20261344545 TERMOPRODUKTDT-1Digital Thermometer10/16/2025Annual10/16/2026740621 Control Company4052Long Stem Thermometer2/27/2024Biennial2/27/2026240174346 MCL BW-N6W5+ 6dB Attenuator CBTN/A CBT1139 MiniCircuits VLF-6000+Low Pass Filter DC to 6000 MHz CBTN/ACBTN/A Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBTN/A CBTN/A Narda 4772-3 Attenuator (3dB) CBTN/A CBT9406 Keysight8710-1765Torque Wrench 4/2/2024Biennial 4/2/20260821000633 Mini-CircuitsZHDC-16-63-S+Coupler CBTN/A CBTN/A Rohde & Schwarz ZNB40Vector Network Analyzer 2/20/2025Annual 2/20/2026101412 SPEAG DAK-3.5 Dielectric Assessment Kit 5/12/2025Annual 5/12/20261070 Keysight Technologies85033EStandard Mechanical Calibration Kit (DC to 9GHz, 3.5mm)2/1/2024Triennial2/1/2027MY53401181 SPEAGEX3DV4SAR Probe5/9/2025Annual5/9/20267660 SPEAG DAE4 Dasy Data Acquisition Electronics 5/9/2025Annual5/9/20261678 ELEMENT MATERIALS TECHNOLOGY (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com ThuyTram Pham Object: Date Issued: Page 2 of 3 D1750V2 β SN: 1148 01/13/2026 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained staβ¦
Text truncated - open the document above for the full version.
FCC ID: A3LSMF776U RF EXPOSURE PART 1 TEST REPORT Approved by: Technical Manager DUT Type: Portable Handset This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX B A P P E N D I X B : S A R D I P O L E V E R I F I C A T I O N P L O T S B1 ELEMENT DUT: Dipole 13.000 MHz; Type: CLA-13 - SN1002 Communication System: UID: 0, CW; Frequency: 13.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 13.000 MHz; cond = 0.786 S/m; perm = 53.1; density = 1000 kg/m3 Phantom Section: Flat; Space: 0 mm Test Date: 04/23/2026; Ambient Temp: 20.7Β°C; Tissue Temp: 21.3Β°C Probe: EX3DV4 - SN7570; ConvF:(19.27,21.05,18.22); Calibrated: 2026-02-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn859; Calibrated: 2026-02-09 Phantom: ELI V8.0; Serial: 2077 Measurement SW: DASY Module SAR V16.4.0.5005 13.0 MHz System Verification at 30.0 dBm (1000 mW) Area Scan (40.0 x 90.0): Measurement grid: dx=10.0 mm, dy=15.0 mm Zoom Scan (30.0 x 30.0 x 31.2): Measurement grid: dx=6.0 mm, dy=6.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 1.06 W/kg SAR(1 g) = 0.491 W/kg; SAR(10 g) = 0.300 W/kg Deviation (1 g) = -2.39%; Deviation (10 g) = -5.06% B2 ELEMENT DUT: Dipole 750.000 MHz; Type: D750V3 - SN1003 Communication System: UID: 0, CW; Frequency: 750.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 750.000 MHz; cond = 0.866 S/m; perm = 41.1; density = 1000 kg/m3 Phantom Section: Flat; Space: 15 mm Test Date: 02/25/2026; Ambient Temp: 22.7Β°C; Tissue Temp: 23.5Β°C Probe: EX3DV4 - SN7547; ConvF:(9.95,9.84,8.92); Calibrated: 2025-12-10 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1322; Calibrated: 2025-12-04 Phantom: Twin-SAM V5.0; Serial: 1759 Measurement SW: DASY Module SAR V17.0.2.6775 750.0 MHz System Verification at 23.0 dBm (200 mW) Area Scan (40.0 x 90.0): Measurement grid: dx=10.0 mm, dy=15.0 mm Zoom Scan (30.0 x 30.0 x 31.2): Measurement grid: dx=6.0 mm, dy=6.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 2.44 W/kg SAR(1 g) = 1.63 W/kg; SAR(10 g) = 1.08 W/kg Deviation (1 g) = -6.54%; Deviation (10 g) = -4.42% B3 ELEMENT DUT: Dipole 750.000 MHz; Type: D750V3 - SN1003 Communication System: UID: 0, CW; Frequency: 750.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 750.000 MHz; cond = 0.882 S/m; perm = 40.4; density = 1000 kg/m3 Phantom Section: Flat; Space: 15 mm Test Date: 03/05/2026; Ambient Temp: 22.9Β°C; Tissue Temp: 22.0Β°C Probe: EX3DV4 - SN7547; ConvF:(9.95,9.84,8.92); Calibrated: 2025-12-10 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1322; Calibrated: 2025-12-04 Phantom: Twin-SAM V5.0; Serial: 1759 Measurement SW: DASY Module SAR V17.0.2.6775 750.0 MHz System Verification at 23.0 dBm (200 mW) Area Scan (40.0 x 90.0): Measurement grid: dx=10.0 mm, dy=15.0 mm Zoom Scan (30.0 x 30.0 x 31.2): Measurement grid: dx=6.0 mm, dy=6.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 2.38 W/kg SAR(1 g) = 1.68 W/kg; SAR(10 g) = 1.12 W/kg Deviation (1 g) = -3.67%; Deviation (10 g) = -0.88% B4 ELEMENT DUT: Dipole 750.000 MHz; Type: D750V3 - SN1003 Communication System: UID: 0, CW; Frequency: 750.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 750.000 MHz; cond = 0.876 S/m; perm = 43.5; density = 1000 kg/m3 Phantom Section: Flat; Space: 15 mm Test Date: 03/09/2026; Ambient Temp: 19.0Β°C; Tissue Temp: 20.0Β°C Probe: EX3DV4 - SN7546; ConvF:(9.51,8.86,9.45); Calibrated: 2025-04-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1368; Calibrated: 2025-04-07 Phantom: Twin-SAM V5.0; Serial: 1715 Measurement SW: DASY Module SAR V17.0.2.6775 750.0 MHz System Verification at 23.0 dBm (200 mW) Area Scan (40.0 x 90.0): Measurement grid: dx=10.0 mm, dy=15.0 mm Zoom Scan (30.0 x 30.0 x 31.2): Measurement grid: dx=6.0 mm, dy=6.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 2.48 W/kg SAR(1 g) = 1.68 W/kg; SAR(10 g) = 1.13 W/kg Deviation (1 g) = -3.67%; Deviation (10 g) = 0.00% B5 ELEMENT DUT: Dipole 750.000 MHz; Type: D750V3 - SN1046 Communication System: UID: 0, CW; Frequency: 750.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 750.000 MHz; cond = 0.902 S/m; perm = 40.1; density = 1000 kg/m3 Phantom Section: Flat; Space: 15 mm Test Date: 03/16/2026; Ambient Temp: 21.0Β°C; Tissue Temp: 22.5Β°C Probe: EX3DV4 - SN7637; ConvF:(9.65,9.9,10.18); Calibrated: 2025-06-12 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1652; Calibrated: 2025-06-04 Phantom: Twin-SAM V5.0; Serial: 1797 Measurement SW: DASY Module SAR V16.4.0.5005 750.0 MHz System Verification at 23.0 dBm (200 mW) Area Scan (40.0 x 90.0): Measurement grid: dx=10.0 mm, dy=15.0 mm Zoom Scan (30.0 x 30.0 x 31.2): Measurement grid: dx=6.0 mm, dy=6.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 2.73 W/kg SAR(1 g) = 1.83 W/kg; SAR(10 g) = 1.21 W/kg Deviation (1 g) = 6.40%; Deviation (10 g) = 7.84% B6 ELEMENT DUT: Dipole 750.000 MHz; Type: D750V3 - SN1003 Communication System: UID: 0, CW; Frequency: 750.000 MHz Medium: Head Simulating Liquid; Medium parameters used: f = 750.000 MHz; cond = 0.876 S/m; perm = 41.6; density = 1000 kg/m3 Phantom Section: Flat; Space: 15 mm Test Date: 03/16/2026; Ambient Temp: 21.3Β°C; Tissue Temp: 21.5Β°C Probe: EX3DV4 - SN7546; ConvF:(9.51,8.86,9.45); Calibrated: 2025-04-11 Sensor-Surface: 1.4mm (VMS + 6p) Electronics: DAE4 Sn1368; Calibrated: 2025-04-07 Phantom: Twin-SAM V5.0; Serial: 1715 Measurement SW: DASY Module SAR V16.4.0.5005 750.0 MHz System Verification at 23.0 dBm (200 mW) Area Scan (40.0 x 90.0): Measurement grid: dx=10.0 mm, dy=15.0 mm Zoom Scan (30.0 x 30.0 x 31.2): Measurement grid: dx=6.0 mm, dy=6.0 mm, dz=1.5 mm; Graded Ratio: 1.5 Peak SAR (extrapolated) = 2.54 W/kg SAR(1 g) = 1.71 W/kg; SAR(10 g) = 1.14 W/kg Deviation (1 g) = -1.95%; Deviation (10 g) = 0.88% B7 ELEMENT DUT: Dipole 750.000 MHz; Type: D750V3 - SN1003 Communication System: UID: 0, CW; Frequency: β¦
Text truncated - open the document above for the full version.
Technical Manager This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. APPENDIX K A P P E N D I X K :FCC ID A3LSMF776U SAR TEST REPORT PART 0, PART 1 Approved by: FCC ID: A3LSMF776JPN RF EXPOSURE PART 1 TEST REPORT DUT Type: Portable Handset FCC ID: A3LSMF776U RF EXPOSURE PART 1 TEST REPORT Approved by: Technical Manager Document S/N: 1M2602190015-34.A3L(Rev2) DUT Type: Portable Handset This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. Page 1 of 198 REV 22.0 03/30/2022 Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from Element. If you have any questions or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. Applicant Name: Date of Testing: Samsung Electronics Co., Ltd. 02/25/2026 β 04/30/2026 129, Samsung-ro, Maetan dong, Test Site/Locations: Yeongtong-gu, Suwon-si Gyeonggi-do, 16677, Korea Element, Columbia, MD, USA Element, Suwon, Korea Document Serial No.: 1M2602190015-34.A3L (Rev 2) F C C I D : A3LS MF776U A P P L I C A N T : SAMS UN G ELE CT RONI CS CO., LT D. DUT Type: Portable Handset Application Type: Certification FCC Rule Part(s): CFR Β§2.1093 Model(s): Additional Model(s): SM-F776U SM-F776U1 This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE C95.1-1992 and has been tested in accordance with the measurement procedures specified in Section 2.9 of this report; for North American frequency bands only. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Test results reported herein relate only to the item(s) tested. The SAR Tick is an initiative of the Mobile & Wireless Forum (MWF). While a product may be considered eligible, use of the SAR Tick logo requires an agreement with the MWF. Further details can be obtained by emailing: [email protected]. SAR 1g Head (W/kg) 1g Body-Worn (W/kg) 1g Body (W/kg) PCE GSM/GPRS/EDGE 850 824.20 - 848.80 MHz 0.71 1.15 1.15 PCE GSM/GPRS/EDGE 1900 1850.20 - 1909.80 MHz <0.1 1.16 1.19 PCE UMTS 850 826.40 - 846.60 MHz 0.57 1.19 1.19 PCE UMTS 1750 1712.4 - 1752.6 MHz 0.11 0.83 0.90 PCE UMTS 1900 1852.4 - 1907.6 MHz 0.11 1.04 1.13 PCE LTE Band 71 665.5 - 695.5 MHz 0.82 1.15 1.15 PCE LTE Band 12 699.7 - 715.3 MHz 0.71 0.89 0.89 PCE LTE Band 13 779.5 - 784.5 MHz 0.84 1.08 1.08 PCE LTE Band 14 790.5 - 795.5 MHz 0.89 1.06 1.06 PCE LTE Band 26 814.7 - 848.3 MHz 0.83 1.15 1.15 PCE LTE Band 5 824.7 - 848.3 MHz N/A N/A N/A PCE LTE Band 66 1710.7 - 1779.3 MHz 0.77 0.89 1.13 PCE LTE Band 4 1710.7 - 1754.3 MHz N/A N/A N/A PCE LTE Band 25 1850.7 - 1914.3 MHz 0.51 1.02 1.11 PCE LTE Band 2 1850.7 - 1909.3 MHz N/A N/A N/A PCE LTE Band 30 2307.5 - 2312.5 MHz 0.65 1.20 1.20 PCE LTE Band 7 2502.5 - 2567.5 MHz 0.91 0.84 1.04 PCE LTE Band 41 2502.5 - 2687.5 MHz 0.33 1.17 1.17 PCE LTE Band 38 2572.5 - 2617.5 MHz N/A N/A N/A CBE LTE Band 48 3552.5 - 3697.5 MHz 0.40 0.39 0.80 PCE NR Band n71 665.5 - 695.5 MHz 0.66 1.19 1.19 PCE NR Band n12 701.5 - 713.5 MHz 0.75 1.17 1.17 PCE NR Band n14 790.5 - 795.5 MHz 0.51 1.19 1.19 PCE NR Band n26 816.5 - 846.5 MHz 0.77 1.19 1.19 PCE NR Band n5 826.5 - 846.5 MHz N/A N/A N/A PCE NR Band n70 1697.5 - 1707.5 MHz 0.62 0.74 0.92 PCE NR Band n66 1712.5 - 1777.5 MHz 0.63 0.63 0.91 PCE NR Band n25 1852.5 - 1912.5 MHz 0.55 1.18 1.18 PCE NR Band n2 1852.5 - 1907.5 MHz N/A N/A N/A PCE NR Band n30 2307.5 - 2312.5 MHz 0.56 1.18 1.18 PCE NR Band n7 2502.5 - 2567.5 MHz 0.90 1.20 1.20 PCE NR Band n41 2501.01 - 2685 MHz 0.60 1.16 1.16 PCE NR Band n38 2575 - 2615 MHz 0.54 N/A N/A CBE NR Band n48 3555 - 3694.98 MHz 0.46 0.63 0.98 PCE NR Band n78 3455.01 - 3544.98 MHz; 3705 - 3795 MHz N/A N/A N/A PCE NR Band n77 3455.01 - 3894.99 MHz; 3905.01 - 3975 MHz 0.58 0.76 0.90 DTS 2.4 GHz WIFI 2412 - 2462 MHz 1.05 0.74 1.06 NII 5 GHz WIFI U-NII-1: 5180 - 5240 MHz U-NII-2A: 5260 - 5320 MHz U-NII-2C: 5500 - 5720 MHz U-NII-3: 5745 - 5825 MHz U-NII-4: 5845 - 5885 MHz 0.97 0.83 1.17 6CD/6VL 6 GHz WIFI U-NII-5: 5935 - 6415 MHz U-NII-6: 6435 - 6515 MHz U-NII-7: 6535 - 6875 MHz U-NII-8: 6895 - 7115 MHz 1.09 0.58 0.58 DSS 2.4 GHz Bluetooth 2402 - 2480 MHz 0.68 0.80 0.82 TNE NTN Band 255 1629 - 1658 MHz N/A 0.31 1.03 DXX NFC 13.56 MHz N/A N/A <0.1 1.59 1.57 1.58 Tx Frequency Band & Mode Equipment Class Simultaneous SAR per KDB 690783 D01v01r03: Head Body-Worn Body 6 GHz WIFI U-NII-5: 5935 - 6415 MHz U-NII-6: 6435 - 6515 MHz U-NII-7: 6535 - 6875 MHz U-NII-8: 6895 - 7115 MHz 7.43 3.90 3.90 5.94 APD (W/m^2) Reported PD (W/m^2) Band & Mode Tx Frequency RF Exposure Position Head Body-worn Product Specific (Wireless Router) Simultaneous Transmission SAR (W/kg) 1.09 1.20 1.20 1.59 Distance (mm) 0 5 5 N/A Overall SAR Summary ELEMENT MATERIALS TECHNOLOGY, Columbia MD (formerly PCTEST) 7185 Oakland Mills Road, Columbia, MD 21046 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.element.com RF EXPOSURE PART 1 TEST REPORT FCC ID: A3LSMF776U RF EXPOSURE PART 1 TEST REPORT Approved by: Technical Manager Document S/N: 1M2602190015-34.A3L(Rev2) DUT Type: Portable Handset This report is Blockchain Verified. To verify the report authenticity, please visit HTTPS://WWW.BLOCKCHAIN-VERIFIED.COM or by clicking on the Blockchain logo. Page 2 of 198 REV 22.0 03/30/2022 Unless otherwise specified, no part of this report may be reproduceβ¦
Text truncated - open the document above for the full version.
19 Chapin Rd., Building D Β· Pine Brook, New Jersey, 07058 Β· United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 123.00 mW |
| 2 | 15E | 5.26 GHz - 5.32 GHz | 122.00 mW |
| 3 | 15E | 5.50 GHz - 5.72 GHz | 123.00 mW |
| 4 | 15E | 5.75 GHz - 5.83 GHz | 126.00 mW |
| 5 | 15E | 5.84 GHz - 5.88 GHz | 45.00 mW |
| 6 | 15E | 5.84 GHz - 5.84 GHz | 45.00 mW |
| 7 | 15E | 5.83 GHz - 5.83 GHz | 45.00 mW |
| 8 | 15E | 5.86 GHz - 5.86 GHz | 440.00 mW |
| 9 | 15E | 5.82 GHz - 5.82 GHz | 43.00 mW |
Portable Handset
Equipment Class
6VL - 15E 6 GHZ Very Low Power DeviceBT,BLE Tablet DTS,UNII a,b,g,n,ac,ax,be and digitizer
Equipment Class
DTS - Digital Transmission SystemPortable Handset
Equipment Class
6CD - 15E 6 GHz Low Power Dual ClientBT,BLE Tablet DTS,UNII a,b,g,n,ac,ax and Digitizer
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterWCDMA, LTE, 5G NR Tablet BT,BLE, DTS,UNII a b g n ac ax and Digitizer
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral