Technical Specifications
| # | Rule Parts | Frequency Range | Power Output |
|---|
| 3 | 15E | 6.54 GHz - 6.86 GHz | 46.00 mW |
Grant NotesPower listed is EIRP. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device can connect to both low power indoor and standard power access points.
This device supports 20/40/80/160/320 MHz BWs.
The highest reported SAR values for head, body-worn, product specific (hot spot), extremity (phablet), and simultaneous transmission exposure conditions are 0.33 W/kg, <0.10 W/kg, 0.16 W/kg, 0.53 W/kg (10-g) and 1.39 W/kg / 2.60 W/kg (10g simultaneous) respectively. To satisfy FCC RF exposure compliance requirements, body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.