Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SPH-A420User’s Guide Draft 2005. 12. 15 Intellectual PropertyAll Intellectual Property, as defined below, owned by or which is otherwise the property of Samsung or its respective suppliers relating to the SAMSUNG Phone, including but not limited to, accessories, parts, or software relating there to (the “Phone System”), is proprietary to Samsung and protected under federal laws, state laws, and international treaty provisions. Intellectual Property includes, but is not limited to, inventions (patentable or unpatentable), patents, trade secrets, copyrights, software, computer programs, and related documentation and other works of authorship. You may not infringe or otherwise violate the rights secured by the Intellectual Property. Moreover, you agree that you will not (and will not attempt to) modify, prepare derivative works of, reverse engineer, decompile, disassemble, or otherwise attempt to create source code from the software. No title to or ownership in the Intellectual Property is transferred to you. All applicable rights of the Intellectual Property shall remain with SAMSUNG and its suppliers. Samsung Telecommunications America (STA), Inc.Headquarters:1301 East Lookout Drive Suite 150 Richardson, TX 75082 Internet Address: http://www.samsungusa.com©2005 Samsung Telecommunications America, Inc. is a registered trademark of Samsung Electronics Amer-ica, Inc. and its related entities.Licensed by Qualcomm Incorporated under one or more of the following patents: U.S. Patent No. 4, 901, 307; 5, 056, 109; 5, 099, 204; 5,101, 501; 5, 103, 459; 5, 107, 225; 5, 109, 390.Openwave® is a registered Trademark of Openwave, Inc.RSA® is a registered TrademarSk RSA Security, Inc. Disclaimer of Warranties; Exclusion of LiabilityEXCEPT AS SET FORTH IN THE EXPRESS WARRANTY CONTAINED ON THE WARRANTY PAGE ENCLOSED WITH THE PRODUCT, THE PURCHASER TAKES THE PRODUCT "AS IS", AND SAMSUNG MAKES NO EXPRESS OR IMPLIED WARRANTY OF ANY KIND WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING BUT NOT LIMITED TO THE MERCHANTABILITY OF THE PRODUCT OR ITS FITNESS FOR ANY PARTICULAR PURPOSE OR USE; THE DESIGN, CONDITION OR QUALITY OF THE PRODUCT; THE PERFORMANCE OF THE PRODUCT; THE WORKMANSHIP OF THE PRODUCT OR THE COMPONENTS CONTAINED THEREIN; OR COMPLIANCE OF THE PRODUCT WITH THE REQUIREMENTS OF ANY LAW, RULE, SPECIFICATION OR CONTRACT PERTAINING THERETO. NOTHING CONTAINED IN THE INSTRUCTION MANUAL SHALL BE CONSTRUED TO CREATE AN EXPRESS OR IMPLIED WARRANTY OF ANY KIND WHATSOEVER WITH RESPECT TO THE PRODUCT. IN ADDITION, SAMSUNG SHALL NOT BE LIABLE FOR ANY DAMAGES OF ANY KIND RESULTING FROM THE PURCHASE OR USE OF THE PRODUCT OR ARISING FROM THE BREACH OF THE EXPRESS WARRANTY, INCLUDING INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, OR LOSS OF ANTICIPATED PROFITS OR BENEFITS. 1 Important safety precautions Failure to comply with the following precautions may be dangerous or illegal. Drive safely at all timesDo not use a hand-held phone while driving. Park the vehicle first. Switch off the phone when refuellingDo not use the phone at a refuelling point (service station) or near fuels or chemicals.Switch off in an aircraftWireless phones can cause interference. Using them in an aircraft is both illegal and dangerous.Switch off the phone near all medical equipmentHospitals or health care facilities may be using equipment that could be sensitive to external radio frequency energy. Follow any regulations or rules in force. 2 InterferenceAll wireless phones may be subject to interference, which could affect their performance. Be aware of special regulationsMeet any special regulations in force in any area and always switch off your phone whenever it is forbidden to use it, or when it may cause interference or danger.Water resistanceYour phone is not water-resistant. Keep it dry. Sensible useUse only in the normal position (held to the ear). Avoid unnecessary contact with the antenna when the phone is switched on.Emergency callKey in the emergency number for your present location, then press . Keep your phone away from small children Keep the phone and all its parts, including accessories, out of the reach of small children.Accessories and batteriesUse only Samsung-approved accessories and batteries. Use of any unauthorised accessories could damage your phone and may be dangerous.Qualified serviceOnly qualified service personnel may repair your phone.For more detailed safety information, see "Health and safety information" on page 18. • The phone could explode if the battery is replaced with an incorrect type.• Dispose of used batteries according to the manufacturer’s instructions. 3 Contents Unpack 4 Make sure you have every itemYour phone 4 Buttons, features, and locationsGet started 5 First steps to operate your phoneInstall and charge the phone ..................................... 5Power on or off........................................................ 6Keys and display ..................................................... 7Menu functions 9 All menu options listedSolve problems 16 Help and personal needsHealth and safety information 18 4 Unpack Make sure you have every itemYou can obtain the following accessories for your phone from your local Samsung dealer. Phone Travel Adapter Battery User’s Guide • Standard Battery • Extended Battery • Battery Charger • Leather Case • Portable Hands free kit • Data Cable• Car Charger/Adaptor • Headset• Travel Charger/Adapter Yo u r p h o n e Buttons, features, and locations Left soft key Volume keys Dial key Special function keys Headset jack Earpiece Display Power on/off/ Menu exit key Alphanumeric keys Right soft key Microphone Navigation keys(Up/Down/Left/Right) OK key Speaker key Back key 5 Get started Get started First steps to operate your phoneInstall and charge the phone Remove the battery cover If the phone is already on, first turn it off by holding [ ]. Install the battery. Replace the cover. Plug the travel adapter into the phone. Plug the adapter into a standard AC wall …
Text truncated - open the document above for the full version.
18600 Broadwick Street December 30, 2005 !"# $%&' ( &) "* +,- . / (0+1+//2(34 (5 /5 ///5 /4(0+1+// 2( 34(5555,4 .(5(65(5 / (5 1 # )57/(5)8 )94144 *4 1 1: ;&/ 1&19<;3<4 December 30, 2005 ! "" "" #$%" & ' ()*+ ! , ! "-) . /01# 23! . A3LSPHA420 , $ 5 5! 1 " . ! 6 2) 5 , )( /01 # 2 3! - $ 5! 5 ' +7" 7" 8 3 and Operational Description " 5 -9 %% 2 : ! " ! ! " ! $%" ! % ! ! 5 " - % ! 6 /01 # 2 3! ! - 7 % % 5! ! "! 7 ! 6 6 ! 7 %- 2 ! 7 - 5 " 6 5 7 % ! 6 /01 # 23! ! 5 " 6 !- 5- 5 "% ! ! 5 5 " ! " 6 !7 "% 5 ! 7 "+ 2 ;"<" =3- /01# " 0 December 30, 2005 ! "" "" # !$ % $&'" # ( )*+, ! - ! ".* /012$ %3!% FCC ID: A3LSPHA420 - & 5 67 " 5! 7 8 " / ! 9%*) !%* 5 -*)012$ %3!% & 6 " 5! 5 '' : ' ' ! ; " 5 ! ' % 7 ! " ! ! " ! &'" ! ' ! ! 5 " . ' ! 9 012 $ %3! ! . ' ' 5! ! "! < ! 9 9 ! < '. % ! < . 5 " 9 5 < ' ! 9 012 $ %3!5 5 " 9 !. 5. 5 "' ! ! 5 5 " ! " 9 !< "' 5! < ", % =">" ?3. 012$ " 1%
Courtenay Geraghty From: Gregory Czumak [[email protected]] Sent: Thursday, October 20, 2005 3:25 PM To: PCTEST - Courtenay Subject: FW: CDMA 2000 application Follow Up Flag: Follow up Flag Status: Red Attachments: CDMA-2000 SAR Config.doc Page 1 of 2 11/7/2005 From: Kwok Chan [mailto:[email protected]] Sent: Thursday, May 19, 2005 11:37 AM To: Gregory Czumak Cc: PCTEST - Al Cirwithian; PCTEST - Randy Ortanez Subject: RE: CDMA 2000 application Greg: According to information available to us, the attached describes the basic criteria for reviewing typical CDMA- 2000 client devices. This should be considered as a draft while we are continuing to review & identify other test and product specific issues. Please let us know if this is insufficient or if more coordination is necessary, and continue to inform us on subsequent CDMA-2000 filings. Kwok Chan -----Original Message----- From: Gregory Czumak [mailto:[email protected]] Sent: Thursday, May 19, 2005 9:10 AM To: Kwok Chan Cc: PCTEST - Al Cirwithian; PCTEST - Randy Ortanez; PCTest - Andrea Zaworski; PCTEST - Keats Ortiz; PCTEST - Steve Liu; PCTEST - Yukio Tanuma Subject: CDMA 2000 application Hi Kwok, I hope all is well with you and your family (your kids must be getting big... I know mine are!). Based on the info provided last week at the Workshop, I am contacting you to let you know that I am currently reviewing an application for a WLL PCS CDMA phone that has CDMA 2000 capabilities. As with most WLL phones that we see, it is designed to replace the phone on your desk (i.e., it sits on the desk, and looks like a regular corded phone- no RF in the handset, just a whip antenna sticking out of the back of the base portion). The lab performed body SAR measurements with a separation distance of 2.5 cm. Is there anything specific for which I should look, given its CDMA 2000 capabilities? Please let me know at your earliest convenience (of course, we are under pressure to finish the review ASAP). I appreciate your time and effort- thank you. Take care. Greg Sincerely, Gregory Czumak Quality Manager Senior Certification Engineer PCTEST Engineering Laboratory, Inc. 6660-B Dobbin Road Columbia, MD 21045 410-290-6652 410-290-6654 (Fax) [email protected] This communication and its attachments contain information from PCTEST Engineering Laboratory, Inc., and is intended for the exclusive use of the recipient (s) named above. It may contain information that is confidential and/or legally privileged. Any unauthorized use that may compromise that confidentiality via distribution or disclosure is prohibited. Please notify the sender immediately if you receive this communication in error, and delete it from your computer system. Usage of PCTEST email addresses for non-business related activities is strictly prohibited. No warranty is made that the e-mail or attachment(s) are free from computer virus or other defect. Thank you. Page 2 of 2 11/7/2005
1 of 41 SAMSUNG ELECTRONICS Co., Ltd., Regulatory Compliance Group IT R&D Center 416, Maetan-3dong, Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea 443-742 TEST REPORT ON SAR Model Tested: SPH-A420 FCC ID (Requested): A3LSPHA420 Job No: FC-155 Report No: FC-155-S1 Date issued: Dec.27, 2005 - Abstract – This document reports on SAR Tests carried out in accordance with FCC/OET Bulletin 65, Supplement C(July 2001). Prepared By Date DK LEE –Test Engineer Checked By Date SH PARK – Senior Manager Authorized By Date JK CHOI – General Manager 2005.12.27 2005.12.27 2005.12.27 Report Number: FC-155-S1 2 of 41 Contents 1. GENERAL INFORMATION............................................................................................................. 3 2. DESCRIPTION OF DEVICE ........................................................................................................... 3 3. DESCRIPTION OF TEST EQUIPMENT ......................................................................................... 4 3.1 SAR Measurement Setup ......................................................................................................4 3.3 SAM Phantom ........................................................................................................................ 8 3.4 Brain & Muscle Simulating Mixture Characterization ............................................................. 8 Table 3.1 Composition of the Brain & Muscle Tissue Equivalent Matter..................................... 9 3.5 Device Holder for Transmitters ..............................................................................................9 3.6 Validation Dipole .................................................................................................................... 9 3.7 Equipment Calibration.......................................................................................................... 10 4. SAR MEASUREMENT PROCEDURE ......................................................................................... 11 5. DESCRIPTION OF TEST POSITION ........................................................................................... 12 5.1 SAM Phantom Shape...........................................................................................................12 5.2 Cheek/Touch Position .......................................................................................................... 12 5.3 EAR/Tilt 15° Position ............................................................................................................ 14 5.4 Body Holster/Belt Clip Configurations.................................................................................. 15 6. MEASUREMENT UNCERTAINTY................................................................................................ 17 7. SYSTEM VERIFICATION ............................................................................................................. 19 7.1 Tissue Verification ................................................................................................................ 19 7.2 Test System Validation ......................................................................................................... 19 8. SAR MEASUREMENT RESULTS ................................................................................................ 20 8.1 Measurement Results(AMPS Right Head SAR - Touch) ..................................................... 21 8.2 Measurement Results(AMPS Right Head SAR - Tilt) .......................................................... 22 8.3 Measurement Results(AMPS Left Head SAR - Touch)........................................................ 23 8.4 Measurement Results(AMPS Left Head SAR - Tilt)............................................................. 24 8.5 Measurement Results(AMPS Body SAR without Holster) ................................................... 25 8.6 Measurement Results(CDMA Right Head SAR - Touch) ..................................................... 26 8.7 Measurement Results(CDMA Right Head SAR - Tilt) .......................................................... 27 8.8 Measurement Results(CDMA Left Head SAR - Touch) ....................................................... 28 8.9 Measurement Results(CDMA Left Head SAR - Tilt) ............................................................ 29 8.10 Measurement Results(CDMA Body SAR without Holster)................................................. 30 8.11 Measurement Results(PCS Right Head SAR - Touch) ...................................................... 31 8.12 Measurement Results(PCS Right Head SAR - Tilt) ........................................................... 32 8.13 Measurement Results(PCS Left Head SAR - Touch) ........................................................ 33 8.14 Measurement Results(PCS Left Head SAR - Tilt) ............................................................. 34 8.15 Measurement Results(PCS Body SAR without Holster).................................................... 35 9. CONCLUSION .............................................................................................................................. 36 10. REFERENCES ............................................................................................................................ 37 Report Number: FC-155-S1 3 of 41 1. GENERAL INFORMATION Test Sample : Tri-Mode Dual-Band Analog/PCS Phone(AMPS/CDMA) Model Number : SPH-A420 Serial Number : Identical prototype (S/N : # FC-155-I) Manufacturer : SAMSUNG ELECTRONICS Co., Ltd. Contact : JJ JUNG Phone : +82-54-479-5932 Fax : +82-54-479-5932 Test Standard : §2.1093; FCC/OET Bulletin 65, Supplement C(July 2001) FCC Classification : Licensed Portable Transmitter Held to Ear (PCE) Test Dates : Dec.23, 2005 Tested for : FCC/TCB Certification 2. DESCRIPTION OF DEVICE Tx Freq. Range : 824.04 ~ 848.9 MHz (AMPS) 824.70 ~ 848.31 MHz (CDMA) 1851.25 ~ 1908.75 MHz (PCS) Rx Freq. Range : 869.04 ~ 893.97 MHz (AMPS) 869.70…
Text truncated - open the document above for the full version.
SAMSUNG FCC ID : A3LSPHA420 835MHz AMPS Head SAR DUT: SPH-A420; Serial: FC-155-I Program Name: SPH-A420 AMPS Left (Job No. : FC-155) Procedure Name: Cheek/Touch, Ch.0799, Intenna, Bat. Standard Procedure Notes: Meas.Ambient Temp(celsius)-21.7;Tissue Temp(celsius)-21.5;Test Date-23/Dec/2005[OET Bulletin 65-Supplement C, July 2001] Communication System: AMPS; Frequency: 848.97 MHz;Duty Cycle: 1:1 Medium parameters used: f = 848.97 MHz; σ = 0.91 mho/m; ε r = 41.1; ρ = 1000 kg/m 3 Phantom section: Left Section DASY4 Configuration: - Probe: ES3DV3 - SN3080; ConvF(5.75, 5.75, 5.75); Calibrated: 2005-05-26 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn670; Calibrated: 2005-04-05 - Phantom: SAM 835/900 MHz; Type: SAM; Serial: TP-1141 - Measurement SW: DASY4, V4.6 Build 23; Postprocessing SW: SEMCAD, V1.8 Build 160 Cheek/Touch, Ch.0799, Intenna, Bat. Standard/Area Scan (51x71x1): Measurement grid: dx=20mm, dy=20mm Maximum value of SAR (interpolated) = 0.845 mW/g Cheek/Touch, Ch.0799, Intenna, Bat. Standard/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.35 V/m; Power Drift = -0.103 dB Peak SAR (extrapolated) = 1.23 W/kg SAR(1 g) = 0.816 mW/g Maximum value of SAR (measured) = 0.886 mW/g 0 dB = 0.886mW/g
SAMSUNG ELECTRONICS Co., Ltd., Regulatory Compliance Group IT R&D Center 416 Maetan3-Dong, Yeongtong-gu, Suwon city, Gyeonggi-Do, Korea 442-742 FCC CFR47 PART 22 & 24 SUBPART CERTIFICATION REPORT Model Tested: SPH-A420 FCC ID (Requested): A3LSPHA420 Report No: FC-155-R1 Job No: FC-155 Date issued: December 26, 2005 - Abstract – All measurement reported herein accordance with FCC Rules, 47CFR Part2, Part22, Part24. Prepared By Date WT JANG – Test Engineer Checked By Date SH PARK – Senior Manager Authorized By Date JK CHOI – General Manager © Copyright SAMSUNG Electronics 2005 Report Number : FC-155-R1 TABLE OF CONTENT MEASUREMENT REPORT Page 1. FCC Certification Information 3 1.1 2.1033 General Information 3 2. INTRODUCTION 4 2.1 General 4 3. MEASURING INSTRUMENT CALIBRATION 5 4. TEST EQUIPMENT LIST 6 5. DESCRIPTION OF TESTS 7 5.1 Effective Radiated Power/Equivalent Isotropic Radiated Power 7 5.2 Radiated Spurious & Harmonic Emission 8 5.3 Occupied Bandwidth 10 5.4 Spurious and Harmonic Emissions at Antenna Terminal 10 5.4.1 Occupied Bandwidth Emission Limits 10 5.4.2 Conducted Spurious Emission 11 5.5 Frequency Stability / Temperature Variation 12 6. TEST DATA 13 6.1 Effective Radiated Power(E.R.P.) 13 6.2 Equivalent Isotropic Radiated Power(E.I.R.P.) 14 6.3 Cellular CDMA Radiated Spurious & Harmonic Measurement 15 6.4 PCS CDMA Radiated Spurious & Harmonic Measurement 16 6.5 CDMA Radiated Spurious & Harmonic Conversion Table 17 6.6 PCS Radiated Spurious & Harmonic Conversion Table 18 6.7 Frequency Stability 19 6.7.1 CDMA Frequency Stability Table 19 6.7.2 PCS Frequency Stability Table 20 6.7.3 CDMA Frequency Stability Graph 21 6.7.4 PCS Frequency Stability Graph 23 7.SAMPLE CALCULATION 25 7.1 Emission Designator 8. CONCLUSION 26 9. TEST PLOTS 27 Report Number : FC-155-R1 MEASUREMENT REPORT 1. FCC Certification Information The following information is in accordance with FCC Rules, 47CFR Part2, Subpart J, Sections 2.1033 – 2.1055. 2.1033 General Information Applicant Name: SAMSUNG ELECRONICS CO., LTD. Address: 416 Maetan3-Dong, Yeongtong-gu, Suwon City Gyeonggi-Do, Korea 442-742 Attention: FCC ID: SungJoo KIM, Engineering Manager (QA Lab) A3LSPHA420 Quantity: Quantity production is planned Emission Designators: 40K0F8W, 40K0F1D (AMPS), 1M25F9W Tx Freq. Range: 824.04-848.97MHz (AMPS) 824.70-848.31MHz (CDMA) 1851.25-1908.75MHz (PCS CDMA) Rx Freq. Range: 869.04-893.97 MHz (AMPS) 869.70-893.31 MHz (CDMA) 1931.25-1988.75 MHz (PCS CDMA) Max. Power Rating: 0.146 W ERP AMPS( 21.63 dBm) 0.116 W ERP CDMA( 20.65 dBm) 0.272 W EIRP PCS CDMA ( 24.35 dBm) FCC Classification(s): Licensed Portable Tx Held to Ear (PCE) Equipment (EUT) Type: Tri-Mode Dual-Band Analog/PCS Phone(AMPS/CDMA) Modulation(s): AMPS/CDMA Frequency Tolerance: 0.00025% (2.5ppm) FCC Rule Part(s): 24(E), 22(H), 2. Dates of Test: December 22-23, 2005 Place of Test: SAMSUNG Lab, Test Report S/N: FC-155-R1 Report Number : FC-155-R1 2. INTRODUCTION General These measurement test were conducted at SAMSUNG ELECTRONICS CO., LTD(SUWON). The site address is 416 Maetan3-Dong, Yeongtong-gu, Suwon City, Gyeonggi-Do, Korea 442-742 The site have 1 Fully-anechoic chamber and measurement facility. Measurement Procedure The radiated and spurious measurements were made Fully-anechoic chamber at a 3-meter test range (see Figure2). The equipment under testing was placed on a wooden turntable 3-meters from the receive antenna. The receive antenna height and turntable rotations were adjusted for the highest reading on the receive spectrum analyzer. The substitution antenna will replace the EUT antenna it the same position and in vertical polarization. The frequency of the signal generator shall be set to the frequencies that were measured on the EUT. The test antenna shall be raised and lowered, if necessary, to ensure that the maximum signal is still being received. The signal generator, output level, shall be adjusted until an equal or a known related level to what was measured from the EUT is obtained in the spectrum analyzer. This level was recorded. For readings above 1 GHz, the above procedure is repeated using horn antennas and the difference between the gain of the horn and an isotropic antenna are taken into consideration. Figure1. Map of the Suwon City area. Fi gure2. Photograph of 3m Fully-Anechoic Chamber Report Number : FC-155-R1 3.MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer’s recommendations for utilizing calibration equipment, which is traceable to recognized national standards. - End of page - Report Number : FC-155-R1 4. TEST EQUIPMENT LIST Name of Equipment Model Serial No. Due Date ESI26 836119/010 2006-09-26 E4440A(3Hz~26.5GHz) MY41000236 2006-10-13 Spectrum Analyzer E4440A(3Hz~26.5GHz) MY41000233 2006-10-20 SMIQ03B 83824/021 2005-12-27 Signal Generator SMR20 835197/030 2006-01-18 Power Meter E4419B GB41293846 2006-09-07 8481B 3318A10325 2006-09-08 Power Sensor 8485A 3318A19924 2006-09-08 Pre-Amplifier 8449B 3008A00691 2006-01-11 8960 GB42230535 2006-10-20 Communication test set 8960 GB42360886 2006-10-17 Antenna Master MA0001 ANT0967 Not Required Controller HD100 100/756 Not Required SH-241 92000548 2006-11-22 Environmental Chamber SH-241 92000549 2006-11-22 HF906 360306/011 2006-03-17 Horn Antenna HF906 100134 2006-04-25 3121C-DB4 9007-588 2006-06-04 Dipole Antenna 3121C-DB4 9007-587 2006-12-02 HL040 353255/019 2006-08-24 Receive Antenna HL040 353255/020 2006-06-21 11636B 51941 Not Required 11636B 51942 Not Required Divider 11636B 51946 Not Required WHK1.0/15G-10SS 1 Not Required WHK1.0/15G-10SS 1 Not Required WHK/3.5/18G-10SS 3 Not Required High Pass Filter WHK/3.5/18G-10SS 4 Not Required Shielded Fully Anechoic Chamber RF0002 ANT0001 Not Required Report Number : FC-155-R1 5. DESCRIPTION OF TESTS \ 5.1 Effective Radiated Power / Equivalent Isotropic Radiated Power Test Set-up for the ERP/EIRP TEST Effective…
Text truncated - open the document above for the full version.
PCTEST PT. 22/24 SUPPLEMENT FCC MEASUREMENT SUPPLEMENT Reviewed By: Quality Manager Test Report S/N: 0512300875 Test Dates: December 30, 2005 Phone Type: Tri-Mode Dual-Band FCC ID: A3LSPHA420 Page 1 of 6 © 2005 PCTEST ENGINEERING LABORATORY, INC. 1.1 Test Data 1.2 Effective Radiated Power Output A. POWER: Low (Analog Mode) Freq. Tuned REF. LEVEL POLERPERP (MHz)(dBm)(H/V)(W)(dBm) 824.04-40.850V0.0010.423 835.89-40.220V0.0011.201 848.97-39.951V0.0011.634 B. POWER: High (Analog Mode) Freq. Tuned REF. LEVEL POLERPERPBATTERY (MHz)(dBm)(H/V)(W)(dBm) 824.04-20.850H0.11020.423Standard 836.49-20.220H0.13221.209Standard 848.97-19.951H0.14621.634Standard Note: Standard batteries are the only options for this phone NOTES: Effective Radiated Power Output Measurements by Substitution Method according to ANSI/TIA/EIA-603-A-2001, Aug. 15, 2001: The EUT was placed on a wooden turn table 3-meters from the receive antenna. The receive antenna height and turntable rotation was adjusted for the highest reading on the receive spectrum analyzer. For CDMA signals, a peak detector is used, with RBW = VBW = 3 MHz. For AMPS, GSM, and NADC TDMA signals, a peak detector is used, with RBW = VBW = 1 MHz. A half-wave dipole was substituted in place of the EUT. This dipole antenna was driven by a signal generator and the level of the signal generator was adjusted to obtain the same receive spectrum analyzer reading. The conducted power at the terminals of the dipole is measured. The ERP is recorded. PCTEST PT. 22/24 SUPPLEMENT FCC MEASUREMENT SUPPLEMENT Reviewed By: Quality Manager Test Report S/N: 0512300875 Test Dates: December 30, 2005 Phone Type: Tri-Mode Dual-Band FCC ID: A3LSPHA420 Page 2 of 6 © 2005 PCTEST ENGINEERING LABORATORY, INC. 2.1 Test Data 2.2 AMPS Radiated Measurements Field Strength of SPURIOUS Radiation OPERATING FREQUENCY: 824.04MHz CHANNEL: 0991 (Low) MEASURED OUTPUT POWER: 21.634 dBm =0.146W MODULATION SIGNAL: FM (Internal) DISTANCE: 3meters LIMIT: 43 + 10 log 10 (W) = 34.63 dBc FREQ. LEVEL @ ANTENNA SUBSTITUTE ANTENNA CORRECT GENERATOR POL (MHz)TERMINALS (dBm) GAIN (dBd) LEVEL (dBm) (H/V) 1648.08-47.386.10-41.28H 2472.12-61.686.70-54.98H 3296.16-50.086.80-43.28H 4120.20-60.786.50-54.28H 4944.24-62.687.00-55.68H NOTES: 62.9 (dBc) 64.9 76.6 77.3 75.9 Radiated Spurious Emission Measurements by Substitution Method according to ANSI/TIA/EIA-603-A-2001, Aug. 15, 2001: The EUT was placed on a wooden turn table 3-meters from the receive antenna. The receive antenna height and turntable rotation was adjusted for the highest reading on the receive spectrum analyzer. For CDMA signals, a peak detector is used, with RBW = VBW = 3 MHz. For AMPS, GSM, and NADC TDMA signals, a peak detector is used, with RBW = VBW = 1 MHz. A half-wave dipole was substituted in place of the EUT. This dipole antenna was driven by a signal generator and the level of the signal generator was adjusted to obtain the same receive spectrum analyzer reading. This spurious level is recorded. For readings above 1GHz, the above procedure is repeated using horn antennas and the difference between the gain of the horn and an isotropic or dipole antenna are taken into consideration. PCTEST PT. 22/24 SUPPLEMENT FCC MEASUREMENT SUPPLEMENT Reviewed By: Quality Manager Test Report S/N: 0512300875 Test Dates: December 30, 2005 Phone Type: Tri-Mode Dual-Band FCC ID: A3LSPHA420 Page 3 of 6 © 2005 PCTEST ENGINEERING LABORATORY, INC. 2.1 Test Data (Continued) 2.3 AMPS Radiated Measurements Field Strength of SPURIOUS Radiation OPERATING FREQUENCY: 836.52MHz CHANNEL: 0384 (Mid) MEASURED OUTPUT POWER: 21.634 dBm =0.146W MODULATION SIGNAL: FM (Internal) DISTANCE: 3meters LIMIT: 43 + 10 log 10 (W) = 34.63 dBc FREQ. LEVEL @ ANTENNA SUBSTITUTE ANTENNA CORRECT GENERATOR POL (MHz)TERMINALS (dBm) GAIN (dBd) LEVEL (dBm) (H/V) 1673.04-44.386.10-38.28H 2509.56-57.786.70-51.08H 3346.08-58.686.80-51.88H 4182.60-59.886.50-53.38H 5019.12-61.287.00-54.28H NOTES: 59.9 (dBc) 73.5 72.7 75.9 75.0 Radiated Spurious Emission Measurements by Substitution Method according to ANSI/TIA/EIA-603-A-2001, Aug. 15, 2001: The EUT was placed on a wooden turn table 3-meters from the receive antenna. The receive antenna height and turntable rotation was adjusted for the highest reading on the receive spectrum analyzer. For CDMA signals, a peak detector is used, with RBW = VBW = 3 MHz. For AMPS, GSM, and NADC TDMA signals,…
Text truncated - open the document above for the full version.
6660-B Dobbin Road · Columbia, Maryland · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 24E | 1.85 GHz - 1.91 GHz | 272.00 mW | 1M25F9W | 2.5 ppm |
Portable Handset
Equipment Class
6VL - 15E 6 GHZ Very Low Power DeviceBT,BLE Tablet DTS,UNII a,b,g,n,ac,ax,be and digitizer
Equipment Class
DTS - Digital Transmission SystemPortable Handset
Equipment Class
6CD - 15E 6 GHz Low Power Dual ClientBT,BLE Tablet DTS,UNII a,b,g,n,ac,ax and Digitizer
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterWCDMA, LTE, 5G NR Tablet BT,BLE, DTS,UNII a b g n ac ax and Digitizer
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral