Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
www.camero-tech.com This Device Complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Operation of this device is restricted to law enforcement, emergency rescue and firefighter personnel. Operation by any other party is a violation of 47 U.S.C 301 and could subject the operator to serious legal penalties. Attestation Statement Xaver TM 100 FCC ID: A42X100F Delta Building, P.O Box 3521, Grand Netter Industrial Zone Kfar Netter, Zip Code 40593 Tel:+972-73-7172333 Fax:+972-73-7172323
www.camero-tech.com FCC LABEL and location Xaver TM 100 FCC ID: A42X100F Delta Building, P.O Box 3521, Grand Netter Industrial Zone Kfar Netter, Zip Code 40593 Tel:+972-73-7172333 Fax:+972-73-7172323 60.5 mm 22.5 mm Xaver TM 100 User Manual Screen Interface 60.5 mm 22.5 mm
TTS 54116125 Page 1 of 46 Test Report for Certification of Xaver TM 100 Through Wall Imaging System Customer: Camero Tech Date: December 16, 2011 TDK Report: TTS 54116125 Test performed by: TDK R&D Corporation 1101 Cypress Creek Rd Cedar Park, TX 78613 Test Engineer Checked by Radiated 9 kHz to 40 GHz B. Hall N. Mellen Report B. Hall N. Mellen TTS 54116125 Page 2 of 46 TABLE OF CONTENTS 1 Executive Summary ............................................................................................ 3 2 Task Description ................................................................................................. 4 2.1 Scope .......................................................................................................... 4 2.2 Related Submittal(s)/Grant(s) ........................................................................ 4 2.3 Test Plan References .................................................................................... 5 2.4 Client Information ......................................................................................... 5 2.5 Equipment Under Test (EUT) ......................................................................... 5 3 Facilities and Accreditation .................................................................................. 9 3.1 Facilities and Equipment ................................................................................ 9 3.2 Laboratory Accreditations and Listings ........................................................... 9 3.3 Table of Accreditations and Listings ............................................................... 9 4 Test Equipment and Procedure ......................................................................... 10 4.1 Test and Measurement Equipment ............................................................... 10 4.2 Measuring Instrument Calibration ................................................................ 11 4.3 Measurement Uncertainty ............................................................................ 11 4.4 Test Setup for UWB Device Tests ................................................................. 11 4.5 Measurement Calculations ........................................................................... 16 5 Operational Limitations ..................................................................................... 19 5.1 FCC 47 CFR Section 15.510 (d)(1) ............................................................... 19 5.2 FCC 47 CFR Section 15.510 (d)(2) ............................................................... 19 5.3 FCC 47 CFR Section 15.510 (e) .................................................................... 19 6 Test Limits, Procedures, Results and Setups ....................................................... 20 6.1 UWB Bandwidth .......................................................................................... 20 6.2 Radiated Emissions, UWB Specific Requirements .......................................... 22 6.3 Radiated Emissions in GPS Bands ................................................................ 34 6.4 Peak Radiated Emissions in a 50 MHz RBW .................................................. 36 6.5 AC Mains LineConducted Disturbance ......................................................... 39 7 Labeling and Instruction Manual Requirements .................................................. 40 8 Certification Information ................................................................................... 41 9 Coordination Requirements ............................................................................... 45 TTS 54116125 1 Executive Summary An EMC evaluation to determine compliance of the Xaver System with the requirements of FCC 47 CFR Part 15, Subpart F Section 15.510 and the following data is presented in support of th Wall Imaging System. The client should retain a copy of this document on file for at least 5 years after the manufacturing of the product has been discontinued. Test Description Operational Limitations UWB Bandwidth Radiated Emissions Radiated Emissions in GPS Bands Peak Emissions within a 50 MHz Bandwidth Labeling Requirements Report prepared by: Bill Hall December 16, 2011 Executive Summary mine compliance of the Xaver TM 100 Through Wall Imaging System with the requirements of FCC 47 CFR Part 15, Subpart F Section 15.510 and the following data is presented in support of the Certification of the Xaver TM 1 ing System. The client should retain a copy of this document on file for at least 5 years after the manufacturing of the product has been discontinued. FCC 47 CFR Section Compliance Operational Limitations 15.510(d) The client has been notified of these limitations. 15.510(a) Yes 15.510(3), 15.209 Yes Radiated Emissions in GPS 15.510(4) Yes Peak Emissions within a 50 15.510(5) Yes 15.19/15.510(e) Yes Approved by: Neal Mellen December 16, 2011 December 19, 2011 Page 3 of 46 00 Through Wall Imaging System with the requirements of FCC 47 CFR Part 15, Subpart F Section 15.510 and the 100 Through ing System. The client should retain a copy of this document on file for at least 5 years after the manufacturing of the product has been discontinued. Compliance The client has tified of these limitations. , 2011 TTS 54116125 Page 4 of 46 2 Task Description 2.1 Scope Reference FCC 47 CFR, Part 15, Subpart F, UltraWideband Operation FCC ET Docket No. 98153, FCC 0248 First R&O, Revision of Part 15 of the Commission’s Rules Regarding UltraWideband Transmissions Systems; FCC ET Docket No. 04352, Petition for Waiver of the Part 15 UWB Regulations Filed by MBOASIG (Adopted: March 10, 2005). Purpose of Test To gain FCC Certification for technical requirements for Through Wall Imaging Systems operating between 1990 MHz and 10600 MHz. Test Procedures The tests were conducted in accordance with the following documents: • ANSI C63.4: 2009: Methods of Measurement of RadioNoise Emissions from LowVoltage Elect…
Text truncated - open the document above for the full version.
1101 Cypress Creek Rd · Cedar Park, Texas · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15F | 2.00 GHz - 6.60 GHz | - |

Xaver 400
Equipment Class
UWB - Ultra Wideband Transmitter