Use & Care Manual Models ENGLISH 3 Table of Contents Page Pay attention to these symbols present in this manual: WARNING • This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. • You can be killed or seriously injured if you don't follow these instructions. READ AND SAVE THESE INSTRUCTIONS. WARNINGS FOR ELECTRIC INSTALLATION WARNING • Installation and service must be performed by a qualified installer or service agency. • The _____ models may be powered at 240V or 208V. CAUTION • Always disconnect the electrical plug from the wall receptacle before servicing this unit. • For personal safety, this appliance must be properly grounded. Do not under any circumstances cut or remove the third (ground) prong from the power cord plug. This unit has been tested and found to comply with the limits for a class B digital device, pursuant to Part 18 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This unit generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this unit does cause harmful interference to radio or television reception, which can be determined by turning the unit off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antennae. • Increase the distance between the unit and receiver. • Connect the unit into an outlet or a circuit different from that to which the receiver is connected. CAUTION: Persons with a pacemaker or similar medical device should exercise caution when using or standing near an induction unit while it is in operation. The electromagnetic field may affect the working of the pacemaker or similar medical device. It is advisable to consult your doctor or the pacemaker manufacturer about your particular situation Use & Care Manual Models ENGLISH 4 IMPORTANT Safety Instructions Please read all instructions before using this appliance. COOKTOP SAFETY WARNING Proper Installation • Be sure your appliance is properly installed and grounded by a qualified technician. Never Use Your Appliance for Warming or Heating the Room Do Not Leave Children Alone • Children should not be left alone or unattended in area where appliance is in use. They should never be allowed to sit or stand on any part of the appliance. Wear Proper Apparel • Loose-fitting or hanging garments should never be worn while using the appliance. User Servicing • Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician. Storage in or on Appliance • Flammable materials should not be stored in an oven or near surface units. Do Not Use Water on Grease Fires • Smother fire or flame or use dry chemical or foam-type extinguisher. Use Only Dry Potholders • Moist or damp potholders on hot surfaces may result in burns from steam. Do not let potholder touch hot heating elements. Do not use a towel or other bulky cloth. Use Proper Pan Size • This appliance is equipped with one or more surface units of different size. Select utensils having flat bottoms large enough to cover the surface unit heating element. The use of undersized utensils will expose a portion of the heating element to direct contact and may result in ignition of clothing. Proper relationship of utensil to burner will also improve efficiency. Never Leave Surface Units Unattended at High Heat Settings • Boil over causes smoking and greasy spillovers that may ignite. Make Sure Reflector Pans or Drip Bowls Are in Place • Absence of these pans or bowls during cooking may subject wiring or components underneath to damage. Protective Liners • Do not use aluminum foil to line surface unit drip bowls or oven bottoms, except as suggested in the manual. Improper installation of these liners may result in a risk of electric shock, or fire. Glazed Cooking Utensils • Only certain types of glass, glass/ceramic, ceramic, earthenware, or other glazed utensils are suitable for range-top service without breaking due to the sudden change in temperature. Utensil Handles Should Be Turned Inward and Not Extend Over Adjacent Surface Units • To reduce the risk of burns, ignition of flammable materials, and spillage due to unintentional contact with the utensil, the handle of a utensil should be positioned so that it is turned inward, and does not extend over adjacent surface units. Do Not Soak Removable Heating Elements • Heating elements should never be immersed in water. Do Not Cook on Broken Cook-Top • If cook-top should break, cleaning solutions and spillovers may penetrate the broken cook- top and create a risk of electric shock. Contact a qualified technician immediately. Clean Cook-Top With Caution • If a wet sponge or cloth is used to wipe spills on a hot cooking area, be careful to avoid steam burn. Some cleaners can produce noxious fumes if applied to a hot surface. Use & Care Manual Models ENGLISH 5 PERSONAL SAFETY WARNING To reduce the risk of injury to persons, in the event of a grease fire, observe the following: • Grease is flammable and should be handled carefully. • Do not use water on grease fires. • Never pick up a flaming pan. Smother sheet or flat tray. • Flaming grease outside of utensil can be extinguished with baking soda or, if available, a multipurpose dry chemical or foam type extinguisher. • Let fat cool before attempting to handle it. • Wipe up spill over immediately. • If you are "flaming" liquors or other spirits under an exhaust, turn the fan off. The draft could cause the flames to spread out of control. • Never leave the surface area unattended at high heat setting. Boil over cause smoking an…
Text truncated - open the document above for the full version.
FU C; M ILA N O Date: 11-03-2011 Telecommunication Certification Body RFI Global Services Ltd Pavilion A Ashwood Park Ashwood Way Basingstoke Hampshire RG238BG England To whom it may concern This is to certify that Fulgor 8rl authorises RFI to act on our behalf for the application of the 812T40NP or 812T40lP to RFI Global Services Ltd. Telecommunication Certification Body. We certify that we are not subject to a denial of Federai benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. Yours sincerely FRANCESCO MAGNANI Business Unit Manager f l=ULGOR s.r.l. Via E. Checchi n. 98 21 013 GALLARATE (ilA) Partit a IV Oll42S81 0026 FULGOR S.r.l-via Egidio Checchi, 98 - 21013 Galiarate(VA) -Italy - te!. +39 0331 795266 fa x +39 0331 772826 Cod.fiscjpart. IVA IT02425610025 R.E.A. 323209 -Capita le Sociale € 115.000,00 i.v
******* Approval code: Code d'approbation: kW-240 VOLTS INDUCTION COUNTER-MOUNTED COOKING UNIT TABLE DE CUISSON A INDUCTION 11/02 ****** ********** E149099 ********* Mod:Serial N° : **** 6,20 7,20 60Hz, AC ONLY 60Hz, AC UNIQUEMENT kW-208 VOLTS Made in Italy 812T40NP LOGO FCC ID: A83-812-813
TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Fulgor srl, 812T40NP and 812T40IP To: 47CFR18.305, 47CFR18.307, FCC/OST MP-5 (1986) and ICES-001 Issue 4 June 2006 Test Report Serial No: RFI-EMC-RP80680JD04A V4.0 Version 4.0 supersedes all previous versions This test report is issued under the authority of Chris Guy, Head of Global Approvals: Checked By: Gareth Bragg Signature: Date of Issue: 28 September 2011 This report is issued in portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, Adding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested. TEST REPORT SERIAL NO: RFI-EMC-RP80680JD04A V4.0 VERSION: 4.0 ISSUE DATE: 28 SEPTEMBER 2011 Page 2 of 42 RFI Global Services Ltd. This page has been left intentionally blank. TEST REPORT SERIAL NO: RFI-EMC-RP80680JD04A V4.0 VERSION: 4.0 ISSUE DATE: 28 SEPTEMBER 2011 RFI Global Services Ltd. Page 3 of 42 TABLE OF CONTENTS 1. Customer Details .............................................................................................................. 5 2. Summary of Testing ......................................................................................................... 6 3. Equipment under Test (EUT) ........................................................................................... 7 4. Support Equipment ........................................................................................................... 8 5. Monitoring Performance .................................................................................................. 9 6. Measurement Uncertainty .............................................................................................. 10 7. Measurements, Examinations and Derived Results .................................................... 11 8. Photographs of EUT ....................................................................................................... 24 9. Graphical Test Results ................................................................................................... 27 TEST REPORT SERIAL NO: RFI-EMC-RP80680JD04A V4.0 VERSION: 4.0 ISSUE DATE: 28 SEPTEMBER 2011 Page 4 of 42 RFI Global Services Ltd. This page has been intentionally left blank. TEST REPORT SERIAL NO: RFI-EMC-RP80680JD04A V4.0 VERSION: 4.0 ISSUE DATE: 28 SEPTEMBER 2011 RFI Global Services Ltd. Page 5 of 42 1. CUSTOMER DETAILS Company Name: Fulgor srl Address: Via E. Checchi 98 Gallarate 21013 VA Italy TEST REPORT SERIAL NO: RFI-EMC-RP80680JD04A V4.0 VERSION: 4.0 ISSUE DATE: 28 SEPTEMBER 2011 Page 6 of 42 RFI Global Services Ltd. 2. SUMMARY OF TESTING 2.1. Test Specification Reference: ICES-001 Issue 4 June 2006 Title: Industrial, Scientific and Medical (ISM) Radio Frequency Generators Reference: 47CFR18.305 and 47CFR18.307 Title: Code of Federal Regulations Title 47 (Telecommunications) 2010: Part 18 (Industrial, Scientific and Medical Equipment) – Sections 18.305 and 18.307. Reference: FCC/OST MP-5 (1986) Title: FCC Methods of Measurements of Radio Noise Emissions from Industrial, Scientific, and Medical Equipment Site Registration: Industry Canada: 3245B-2 FCC: 209735 FCC Reference IC Reference Measurement Type Applicability Result 18.305 4.1 Mains terminal disturbance (AC Mains Input / Output Ports) Y 18.307 4.1 Electromagnetic radiation disturbance Y Notes 1. Not applicable. The EUT is AC powered only. KEY: = Complied = Did not comply 2.2. Location of Testing All the measurements described in this report were performed at the premises of RFI Global Services Ltd, Unit 3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, Hampshire RG24 8AH. 2.3. Deviations from Test Specification For the measurements contained within this test report, there were no deviations from, additions to, or exclusions from the test specification identified above, nor from the requirements defined in the basic standards called up within it. TEST REPORT SERIAL NO: RFI-EMC-RP80680JD04A V4.0 VERSION: 4.0 ISSUE DATE: 28 SEPTEMBER 2011 RFI Global Services Ltd. Page 7 of 42 3. EQUIPMENT UNDER TEST (EUT) 3.1. Description of EUT The EUT was an electric counter-mounted induction cooktop 3.2. Identification of Equipment under Test (EUT) ID# Description Model No Serial No 1 Induction Cooktop 812T40NP and 812T40IP None stated 3.3. Port Identification Port Description Type 1 Enclosure - 3.4. Operating Modes Mode Reference Definition Normal Operation The left rear plate of the EUT was set to maximum power and fast boil 3.5. Modifications NOTE: No modifications were made to the EUT during the course of testing 3.6. Additional Information Related to Testing Equipment Category: Induction Cooktop Intended Operating Environment: Residential Cycle Time: < 1 s Power Supply Requirement(s): 208 VAC and 240 VAC, 60 Hz Weight: 15 kg Dimensions: 764 x 536.4 x 81.2 mm Hardware Version Number: IND5NAR - Model A410 Software Version Number: (control board) IND5G_02_F01_S02 (touch board) PEACOCK_01_F03_S03 TEST REPORT SERIAL NO: RFI-EMC-RP80680JD04A V4.0 VERSION: 4.0 ISSUE DATE: 28 SEPTEMBER 2011 Page 8 of 42 RFI Global Services Ltd. 4. SUPPORT EQUIPMENT 4.1. Identification of Support Equipment Description Manufacturer Model No Serial No 208/240 VAC 60 Hz Power Supply Hewlett Packard 6843A 3531A-00149 4.2. Interconnecting Cables NOTE: No interconnecting cables were used during the course of testing. TEST REPORT SERIAL NO: RFI-EMC-RP80680JD04A V4.0 VERSION: 4.0 ISSUE DATE: 28 SEPTEMBER 2011 RFI Global Services Ltd. Page 9 of 42 5. MONITORING PERFORMANCE 5.1. Overview No immunity testing was performed; therefore performance criteria were not applicable. 5.2. Monitoring EUT Performance during Testing For the purposes of testing, the term “operate as intende…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.018 MHz - 0.052 MHz | - |