FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sony Group Corporation/
  3. AK8-HMZ-WM1

AK8-HMZ-WM1Wireless HD Sink radio module

Sony Group Corporation

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jun 04, 2013
Application Purpose
Original Equipment
Date of Application
May 20, 2013
Equipment Note
Wireless HD Sink radio module
Frequency Range
60162.75000000 - 62957.25000000
Company
Sony Group Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—
β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Manual MODEL : SII-SK63101 FCC ID:AK8-HMZ-WM1 IC : 409B-HMZWM1 1. Example of mounting to the final product. 2. Contents of the plan described in the manual of the final product. For FCC "Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which Main board Cross-section AV/Power Cable RF Boa rd BB ChipRF Chip Battery Module’s shield case Exterior case (ABS) Additional shield case / Heat sink Additional shield case / Heat sink EUT RF board R F F P C RF board R F EUT EUT Heat sink Connect to main board with FPC Assembly AV/Power Cable Battry Top cover EUT Middle cover Battery Bottom cover Screw SONY Corp. can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help." FCC WARNING You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For IC "This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device." For FCC/IC "This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65 and RSS-102 of the IC radio frequency (RF) Exposure rules. 3. Contents of the plan described in the label of the final product. For FCC Label of the end product: For SII-SK63101 module: The final end product must be labeled in a visible area with the following "Contains FCC ID:AK8-HMZ-WM1 ". For IC Label of the end product: For SII-SK63101 module: The final end product must be labeled in a visible area with the following "Contains IC:409B-HMZWM1 ".

External Photos

External MODEL : S FCC ID:A K IC : 409B-H F B l Photos II-SK63101 K8-HMZ-WM HMZWM1 Front side (w Back side (w M1 with back he with front he eat sink) eat sink) Front side Back side ( (with front/b (with front/b back heat si back heat sin SON ink) nk) NY Corp.

ID Label/Location Info

Label De MODEL : S FCC ID:A K IC : 409B-H Put a label esign and II-SK63101 K8-HMZ-WM HMZWM1 on the shie d Locatio M1 eld case on HMZWM1 SON NY Corp. 15mm

Internal Photos

Internal MODEL : S FCC ID:A K IC : 409B-H Photos II-SK63101 K8-HMZ-WM HMZWM1 M1 Front Front( w t(with shield without shie Back d case) eld case) SONNY Corp.

RF Exposure Info

Test report No. : 10005116H-C Page : 1 of 4 Issued date : May 10, 2013 FCC ID : AK8-HMZ-WM1 IC Number : 409B-HMZWM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 MPE Report: RF Exposure [FCC rule] Β§1.1310 Radiofrequency radiation exposure limits. The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Β§1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Β§2.1093 of this chapter. Table 1β€”Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz * = Plane-wave equivalent power density Note 1 to Table 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. Note 2 to Table 1: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or can not exercise control over their exposure. Test report No. : 10005116H-C Page : 2 of 4 Issued date : May 10, 2013 FCC ID : AK8-HMZ-WM1 IC Number : 409B-HMZWM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 [IC rule] RSS-102 Β§4 Exposure Limits For the purpose of this standard, Industry Canada has adopted the SAR and RF field strength limits established in Health Canada’s RF exposure guideline, Safety Code 6. Β§4.2 RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment) Frequency Range (MHz) Electric Field (V/m rms) Magnetic Field (A/m rms) Power Density (W/m 2 ) Averaging Time (minutes) 0.003-1 280 2.19 - 6 1-10 280/f 2.19/f - 6 10-30 28 2.19/f - 6 30-300 28 0.073 2 * 6 300-1500 1.585f 0.5 0.0042f 0.5 f/150 6 1500-15000 61.4 0.163 10 6 15000-150000 61.4 0.163 10 616000/f 1.2 150000-300000 0.158 f 0.5 4.21 x 10 -4 f 0.5 6.67 x 10 -5 f 616000/f 1.2 Note: f is frequency in MHz. * Power density limit is applicable at frequencies greater than 100 MHz. Test report No. : 10005116H-C Page : 3 of 4 Issued date : May 10, 2013 FCC ID : AK8-HMZ-WM1 IC Number : 409B-HMZWM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 [Results] ModeDutyAverageAverage ChannelHorizontalVerticalHorizontalVerticalFactorEIRPEIRP [dBm][dBm][mW][mW][mW][dBm][dB][dBm][mW] LRP Low29.1527.92822.5619.61442.131.59-8.6922.90194.9 ModeSeparation C ha nne lD is ta nc eR e s ultLimitR e s ultLimit [cm] [mW/c m 2 ][mW/cm 2 ][W/m 2 ][W/m 2 ] LRP Low50.62016.2010 Calculating formula: Total Peak EIRP = Horizontal Peak EIRP + Vertical Peak EIRP Average EIRP = Total Peak EIRP + Duty Factor P ower Density = Average EIRP / (4 * Pi * Separation Distance ^ 2) Total Peak EIRP Power Density (IC)P ower Density (FCC) [Duty Factor] Tx typeTx widthTimesTx time [us][us] A158.71158.7 B78.15151172.25 C24.4451098 D6.0560363 Total Tx time [ms]2.792 Period [ms]20.66 Duty [dB]-8.69 Calculating formula: Tx time = Tx width * Times Duty = 10 * log (Total Tx time / P eriod) Test report No. : 10005116H-C Page : 4 of 4 Issued date : May 10, 2013 FCC ID : AK8-HMZ-WM1 IC Number : 409B-HMZWM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 This duty cycle has maximum transmission time in actual operating conditions. It was measured in a state that the weak signal was received from Tx unit. Period Enlarged view Type A Type B, C Type D End of Report

Test Report

Test report No. : 10005116H-A-R1 Page : 1 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 13-EM-F0429 RADIO TEST REPORT Test Report No. : 10005116H-A-R1 Applicant : Sony Corporation Type of Equipment : WirelessHD Sink radio module Model No. : SII-SK63101 FCC ID : AK8-HMZ-WM1 Test regulation: FCC Part 15 Subpart C: 2012 Test Result : Complied 1. This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc. 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the above regulation. 4. The test results in this report are traceable to the national or international standards. 5. This test report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. 6. This report is a revised version of 10005116H-A. 10005116H-A is replaced with this report. Date of test: February 20 to March 6, 2013 Representative test engineer: Hironobu Ohnishi Engineer of WiSE Japan, UL Verification Service Approved by: Takahiro Hatakeda Leader of WiSE Japan, UL Verification Service NVLAP LAB CODE: 200572-0 This laboratory is accredited by the NVLAP LAB CODE 200572-0, U.S.A. The tests reported herein have been performed in accordance with its terms of accreditation. *As for the range of Accreditation in NVLAP, you may refer to the WEB address, http://www.ul.com/japan/jpn/pages/services/emc/about/ma rk1/index.jsp#nvlap Test report No. : 10005116H-A-R1 Page : 2 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 REVISION HISTORY Original Test Report No.: 10005116H-A Revision Test report No. Date Page revised Contents - (Original) 10005116H-A May 10, 2013 - - 1 10005116H-A-R1 May 16, 2013 P6 Added FCC 15B compliance statement in section 3.1 Test report No. : 10005116H-A-R1 Page : 3 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ......................................................................................................... 4 SECTION 2: Equipment under test (E.U.T.) ........................................................................................... 4 SECTION 3: Test specification, procedures & results ............................................................................ 6 SECTION 4: Operation of E.U.T. during testing .................................................................................. 10 SECTION 5: Conducted Emission .......................................................................................................... 12 SECTION 6: Radiated Emission (Spurious Emission, Power Density) ............................................... 13 SECTION 7: Frequency Stability ........................................................................................................... 15 APPENDIX 1: Data of EMI test .............................................................................................................. 16 Conducted Emission ......................................................................................................................... 16 6dB Bandwidth ................................................................................................................................. 18 26dB and 99% Bandwidth ................................................................................................................ 20 Power Density ................................................................................................................................... 22 Peak Output Power ............................................................................................................................ 24 Spurious Emission ............................................................................................................................. 25 Frequency Stability ........................................................................................................................... 29 Group Instllation ............................................................................................................................... 30 Transmitter Identification.................................................................................................................. 30 APPENDIX 2: Test instruments ............................................................................................................. 31 APPENDIX 3: Photographs of test setup ............................................................................................... 33 Conducted Emission ......................................................................................................................... 33 Spurious Emission ............................................................................................................................. 34 Carrier Frequency Measurement ....................................................................................................... 35 Worst Case Position (Horizontal: Y-axis/ Vertical:Y-axis) .............................................................. 36 Frequency Stability ........................................................................................................................... 37 Test report No. : 10005116H-A-R1 Page : 4 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-ch…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 10005116H-A-R1 Page : 33 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 APPENDIX 3: Photographs of test setup Conducted Emission Photo 1 Photo 2 Test report No. : 10005116H-A-R1 Page : 34 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Spurious Emission Photo 1 Photo 2 Test report No. : 10005116H-A-R1 Page : 35 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Carrier Frequency Measurement Photo 1 Photo 2 Test report No. : 10005116H-A-R1 Page : 36 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Worst Case Position (Horizontal: Y-axis/ Vertical:Y-axis) X-axis Y-axis Z-axis Test report No. : 10005116H-A-R1 Page : 37 of 37 Issued date : May 10, 2013 Revised date : May 16, 2013 FCC ID : AK8-HMZ-WM1 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Frequency Stability Photo 1 Photo 2 End of Report

Contact Information

Applicant

Kazuyuki Hori(Chief EMC/RF Compliance Specialist)
[email protected]81-50-3141-6220Fax: 81-50-3750-6540

Technical Contact

UL Japan, Inc.Takahiro Hatakeda
[email protected]81-596-24-8999

4383-326 Asama-cho, Ise-shi Β· Mie-ken Β· Japan

Test Firm

UL Japan, Inc. Head office EMC Lab.Tetsuya Hashimoto
[email protected]+81-596-24-8116Fax: +81-596-24-8095

Technical Specifications

#Rule PartsFrequency RangePower Output
115C60.16 GHz - 62.96 GHz72.30 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Modular Approval. Output power listed is EIRP referred KDB 662911 of Cross-Polarized Antenna. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from Sony Group Corporation

AK8WW81782

Radio Equipment

Aug 21, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
AK8CFIZCP2

Wireless Controller

Aug 03, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
AK8OEV321MUH

LCD Monitor

Apr 14, 2026

Equipment Class

JAD - Part 15 Class A Digital Device
AK8OEV431MUH

LCD Monitor

Apr 14, 2026

Equipment Class

JAD - Part 15 Class A Digital Device
AK8OEV271MUH

LCD Monitor

Apr 14, 2026

Equipment Class

JAD - Part 15 Class A Digital Device