Since this module is not sold to general end users directly, there is no user manual of module. For the details about this module, please refer to the specification sheet of module. This module should be installed in the host device according to the interface specification (installation procedure). The following information must be indicated on the host device of this module; [for FCC] Contains Transmitter Module FCC ID: AK8RCS650IA or Contains FCC ID: AK8RCS650IA This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. *If it is difficult to describe this statement on the host product due to the size, please describe in the User's manual. [for IC] Contains Transmitter Module IC: 409B-RCS650IA or C o n t a i n s I C : 409B-RCS650IA The following statements must be described on the user manual of the host device of this module; [for FCC] FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. [for IC] This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Sony EMCS Corporation 30 Ibarajima Ohya-cho Inazawa-shi, Aichi 492-8545 Japan Product Safety Section 1, Quality Assurance Department 3 Telephone +81-50-3369-5593 Fax +81-587-36-8570 Letter of Authorization Date: August 8, 2014 UL Japan, Inc. 4383-326 Asama-cho, Ise-shi, Mie 516-0021 Japan FCC ID : AK8RCS650IA Applicant : Sony Corporation To whom it may concern: Please be advised we authorize Yoshihisa Maeda of Consumer Technology Division, UL Japan, Inc. to act on our behalf, until otherwise notified, for applications submitted for Federal Communication Commission Radio equipment applications submitted to UL Japan, Inc. We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. The application for the subject equipment has not been submitted to another TCB for certification. Thank you for your attention to this matter. Sincerely, Hideo Nomura Sony EMCS Corporation
Sony EMCS Corporation 30 Ibarajima Ohya-cho Inazawa-shi, Aichi 492-8545 Japan Product Safety Section 1, Quality Assurance Department 3 Telephone +81-50-3369-5593 Fax +81-587-36-8570 Request for Modular Transmitter Approval August 8, 2014 FCC ID : AK8RCS650IA Applicant : Sony Corporation This transmitter, model: RC-S650/IA is designed by us. It complies with the modular transmitters basic requirements (Item 1 to 8) in FCC Part 15 Subpart C Section 15.212 as indicated below: Modular Approval Checklist: Modular approval requirement YesNo (1) Have its own RF shielding. (2) Have buffered modulation/data inputs. (3) Have its own power supply regulation. (4) Comply with the antenna and transmission system requirements of § 15.203, 15.204(b) and 15.204(c). (5) Tested in a stand-alone configuration. Unless the transmitter module will be battery powered, it must comply with the AC line conducted requirements found in FCC § 15.207. AC or DC power lines and data input/output lines connected to the module must not contain ferrites, unless they will be marketed with the module. The length of these lines shall be the length typical of actual use or, if that length is unknown, at least 10 centimeters to insure that there is no coupling between the case of the module and supporting equipment. Any accessories, peripherals, or support equipment connected to the module during testing shall be unmodified and commercially available. (6) Equipped with either a permanently affixed label or must be capable of electronically displaying its FCC ID. If the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. (7) Comply with any specific rules or operating requirements that ordinarily apply to a complete transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. (8) Comply with any applicable RF exposure requirements in its final configuration: The modular transmitter complies with FCC radiation exposure requirement. ________________ Hideo Nomura Sony EMCS Corporation
Sony EMCS Corporation 30 Ibarajima Ohya-cho Inazawa-shi, Aichi 492-8545 Japan Product Safety Section 1, Quality Assurance Department 3 Telephone +81-50-3369-5593 Fax +81-587-36-8570 Request for Confidentiality Date: August 8, 2014 UL Ja pan, Inc. 4383-326 Asama-cho, Ise-shi, Mie 516-0021 Japan FCC ID : AK8RCS650IA Applicant : Sony Corporation To whom it may concern: Please be advised that the following information is to be held confidential on behalf of us, referring to the FCC rules 0.457 and 0.459: Block Diagram Theory of Operation Schematics The application contains technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Sincerely, Hideo Nomura Sony EMCS Corporation
RC-S650/IA External Photograph RC-S650/IA External Photograph
fig2 : assembling label-ID fig1 : detailed label-ID RC-S650/IA Label-ID Instructions RC-S650/IA Label Location RC-S650/IA Label Location
RC-S650/IA Internal Photograph
Test report No. : 10401259S-C Page : 1 of 24 Issued date : August 8, 2014 FCC ID : AK8RCS650IA UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 RADIO TEST REPORT Test Report No.: 10401259S-C Applicant : Sony Corporation Type of Equipment : Contactless IC Card Reader/Writer Model No. : RC-S650/IA FCC ID : AK8RCS650IA Test regulation : FCC Part15 Subpart C: 2014 Test result : Complied 1. This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc. 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. The test results in this test report are traceable to the national or international standards. 5. This test report must not be used by the customer to claim product certification, approval, or endorsement by any agency of the Federal Government. 6. The opinions and the interpretations to the result of the description in this report are outside scopes where UL Japan has been accredited. Date of test: July 28 to August 4, 2014 Tested by: Makoto Hosaka Engineer Consumer Technology Division Approved by : Toyokazu Imamura Leader Consumer Technology Division RTL02610 The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan. There is no testing item of "Non-accreditation". 13-EM-F0429 Test report No. : 10401259S-C Page : 2 of 24 Issued date : August 8, 2014 FCC ID : AK8RCS650IA UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 REVISION HISTORY Original Test Report No.: 10401259S-C Revision Test report No. Date Page revised Contents - (Original) 10401259S-C August 8, 2014 - - Test report No. : 10401259S-C Page : 3 of 24 Issued date : August 8, 2014 FCC ID : AK8RCS650IA UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Contents Page SECTION 1: Customer information ....................................................................................... 4 SECTION 2: Equipment under test (E.U.T.) ......................................................................... 4 SECTION 3: Test specification, procedures & results .......................................................... 5 SECTION 4: Operation of E.U.T. during testing ................................................................... 7 SECTION 5: Conducted emission ........................................................................................... 9 SECTION 6: Radiated emission (Fundamental and Spurious emission) .......................... 10 SECTION 7: 20dB bandwidth & Occupied bandwidth (99%) ........................................... 11 SECTION 8: Frequency tolerances ....................................................................................... 11 Contents of APPENDIXES ...................................................................................................... 12 APPENDIX 1: Data of radio tests .......................................................................................... 13 APPENDIX 2: Test instruments ............................................................................................ 21 APPENDIX 3: Photographs of test setup .............................................................................. 22 Test report No. : 10401259S-C Page : 4 of 24 Issued date : August 8, 2014 FCC ID : AK8RCS650IA UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 SECTION 1: Customer information Company Name : Sony EMCS Corporation Brand Name : SONY Address : Inazawa Site, 30 Ibarajima, Ohya-cho, Inazawa-shi, Aichi, 492-8545 Japan Telephone Number : +81-050-3369-5593 Facsimile Number : +81-0587-36-8570 Contact Person : Hideo Nomura SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Contactless IC Card Reader / Writer Model Number : RC-S650/IA Serial Number : Refer to clause 4.2 Rating : DC 3.3V Country of Mass-production : Japan Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Receipt Date of Sample : July 25 and August 1, 2014 Modification of EUT : No modification by the test lab. 2.2 Product description Model: RC-S650/IA (referred to as the EUT in this report) is a Contactless IC Card Reader/Writer. Clock frequency(ies) in the system : 27.12MHz <Radio part> Equipment type : Transceiver Frequency of operation : 13.56MHz Type of modulation : ASK Antenna type : Loop Antenna connector type : FPC ITU code : A1D Operation temperature range : -10 to +40 deg.C./20 to 90%RH +40 to +60 deg.C./50%RH or lower FCC 15.31 (e) The RFID transmitter is provided the stable voltage (DC1.8V and DC3.1V) via regulator. Therefore, this EUT complies with the requirement. FCC 15.203 This module has a unique antenna coupler, FPC connector. This modular transmitter will always be used in the configuration in which it was authorized. Therefore, this EUT complies with the requirement. Test report No. : 10401259S-C Page : 5 of 24 Issued date : August 8, 2014 FCC ID : AK8RCS650IA UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 SECTION 3: Test specification, procedures & results 3.1 Test specification Test specification : FCC Part 15 Subpart C: 2014, final revised on May 1, 2014 and effective June 2, 2014 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.207 Conducted limits Section 15.209 Radiated emission limits, general requirements Section 15.215 Additional provisions to the general radiated emission limitations Section 15…
Text truncated - open the document above for the full version.
Test report No. : 10005707S-A Page : 21 of 23 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 APPENDIX 3: Photographs of test setup Conducted emission Front Side Test Report No 10401259S-C 22 of 24 Test report No. : 10005707S-A Page : 22 of 23 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Radiated emission Front Rear 9kHz-30MHz Loop antenna: Horizontal Loop antenna: Vertical 30-1000MHz Test Report No 10401259S-C 23 of 24 Test report No. : 10005707S-A Page : 23 of 23 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Pre-check of the worst case X-axis Y-axis Z-axis END OF REPORT Test Report No 10401259S-C 24 of 24
1-22-3 Megumigaoka, Hiratsuka-shi · Kanagawa-ken · Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
Radio Equipment
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterWireless Controller
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterLCD Monitor
Equipment Class
JAD - Part 15 Class A Digital DeviceLCD Monitor
Equipment Class
JAD - Part 15 Class A Digital DeviceLCD Monitor
Equipment Class
JAD - Part 15 Class A Digital Device