FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Harman International Industries, Inc/
  3. APIBAR21ESSSUB

APIBAR21ESSSUB2.1 Channel Soundbar with Wireless Subwoofer

Harman International Industries, Inc

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 28, 2026
Application Purpose
Original Equipment
Equipment Note
2.1 Channel Soundbar with Wireless Subwoofer
Frequency Range
2402.00000000 - 2480.00000000
Company
Harman International Industries, Inc
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Harman International Industries, Inc Covered Equipment Certification Attestation Letter 2026-03-10 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID:APIBAR21ESSSUB Harman International Industries, Inc (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Harman International Industries, Inc (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Harman International Industries, Inc (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Terry Shi Title: Senior Prin.Engineer,Regulatory Compliance, Quality Company Name: Harman International Industries, Inc Address: 8500 Balboa Boulevard, Northridge, CA 91329, United States Phone: 86-75523189391 E-Mail: [email protected] Date: 2026-03-10

Attestation Statements

Harman International Industries, Inc U.S. Agent Designation for Service of Process - Certification Attestation Letter Harman International Industries, Inc 8500 Balboa Boulevard, Northridge, CA 91329, United States Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 2026-03-10 Attestation Statement according to 2.911(d)(7) FCC ID: APIBAR21ESSSUB TO WHOM IT MAY CONCERN: We, Harman International Industries, Inc designate ourselves to act as U.S. agent for service of process. Harman International Industries, Inc hereby acknowledges the obligation of the U.S. agent for service of process. Further Harman International Industries, Inc accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sincerely Applicant Signed/ Designated Agent Signed: Signature: Company name: Harman International Industries, Inc FRN: 0024748147 Address: 8500 Balboa Boulevard, Northridge, CA 91329, United States Contact Person: Terry Shi Telephone No: 86-75523189391 Email: [email protected]

Cover Letter(s)

Harman International Industries, Inc 2026-03-10 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Damon Hu, Guangdong Dongdian Testing Service Co.,Ltd.( Unit 2, Building 1, No.17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808), to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Terry Shi Title: Senior Prin.Engineer,Regulatory Compliance, Quality Company Name: Harman International Industries, Inc Address: 8500 Balboa Boulevard, Northridge, CA 91329, United States Phone: 86-75523189391 E-Mail: [email protected] Date: 2026-03-10

Cover Letter(s)

Harman International Industries, Inc 2026-03-10 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY – FCC FCC ID: APIBAR21ESSSUB Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☐ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Terry Shi Title: Senior Prin.Engineer,Regulatory Compliance, Quality Company Name: Harman International Industries, Inc Address: 8500 Balboa Boulevard, Northridge, CA 91329, United States Phone: 86-75523189391 E-Mail: [email protected] Date: 2026-03-10

ID Label/Location Info

FCC ID: APIBAR21ESSSUB IC: 6132A-BAR21ESSSUB HVIN: BAR2.1ESSSUB CAN ICES(B) / NMB(B) This device complies with Part 15 of the FCC rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2.1 Channel Soundbar with Wireless Subwoofer Wireless Subwoofer Model: Bar 2.1 Essential Power Supply: AC 100-240V~ 50/60Hz 35W Harman International Industries, Incorporated 8500 Balboa Blvd, Northridge, CA 91329, UNITED STATES European Representative: Harman International Industries, Incorporated EMEA Liaison Office, Danzigerkade 16G, 1013 AP Amsterdam, The Netherlands Made in China RS0471-MY0001001

RF Exposure Info

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E06 TRF No.: RT-4-E-006Page 1 of 7 RF EXPOSURE REPORT Applicant : Harman International Industries, Inc. Address of Applicant : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Manufacturer : Harman International Industries, Inc. Address of Manufacturer : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Equipment under Test : 2.1 Channel Soundbar with Wireless Subwoofer Model No. : Bar 2.1 Essential FCC ID : APIBAR21ESSSUB Test Standard(s) : KDB447498 D01 General RF Exposure Guidance v06 Report No. : DDT-RE26012716-2E06 Issue Date : 2026/04/25 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E06 TRF No.: RT-4-E-006Page 2 of 7 Table of Contents 1.General Test Information..............................................................................................5 1.1.Description of EUT .......................................................................................................5 1.2.Accessories of EUT......................................................................................................5 1.3.Test laboratory .............................................................................................................5 2.RF Exposure evaluation for FCC .................................................................................6 2.1.Assessment procedure.................................................................................................6 2.2.Assess result ................................................................................................................7 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E06 TRF:RT-4-E-006Page 3 of 7 $!CeMetaLims!digital$ Test Report Declare Applicant : Harman International Industries, Inc. Address of Applicant : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Equipment under Test : 2.1 Channel Soundbar with Wireless Subwoofer Model No. : Bar 2.1 Essential Manufacturer : Harman International Industries, Inc. Address of Manufacturer : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Test Standard Used: KDB447498 D01 General RF Exposure Guidance v06 We Declare: The equipment described above is tested by Guangdong Dongdian Testing Service Co., Ltd. and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Guangdong Dongdian Testing Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. Report No.:DDT-RE26012716-2E06 Date of Receipt:2026/02/03Date of Test:2026/02/03~2026/03/06 Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Guangdong Dongdian Testing Service Co., Ltd. Created: Chen Ziqin Reviewed: Zoe PengApproved: Damon Hu 2026/03/062026/04/252026/04/25 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E06 TRF:RT-4-E-006Page 4 of 7 Revision History VersionRevision ContentIssue DateApproved V0Initial issue2026/04/25Damon Hu Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E06 TRF:RT-4-E-006Page 5 of 7 1. General Test Information 1.1. Description of EUT EUT Name:2.1 Channel Soundbar with Wireless Subwoofer Model Number:Bar 2.1 Essential Difference of model number:/ EUT Function Description:Please reference user manual of this device Power Supply: For Soundbar: AC 100-240V~ 50/60Hz 30W For Subwoofer: AC 100-240V~ 50/60Hz 35W Note: The above EUT information is declared by manufacturer and for more detailed features description please refer to the manufacturer's specifications or User's Manual. 1.2. Accessories of EUT AccessoriesManufacturerModel numberDescription AC cableHarmanN/ALength: 1.5m HDMI cableHarmanN/ALength: 1.2m Remote controlHarmanN/AN/A 1.3. Test laboratory Guangdong Dongdian Testing Service Co., Ltd. Add.: Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808. Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected]. CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, R-20240, G-20118 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E06 TRF:RT-4-E-006Page 6 of 7 2. RF Exposure evaluation for FCC 2.1. Assessment procedure Requirement: Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic FieldStrength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.346141.63(100)*30 1.34-30824/f2.19/f(180/f)*30 30-30027.50.0730.230 300-1500 F/150030 1500-100000 1.030 Note: f= frequency in MHz; *Plane-wave equivalent power density Calculation method From the peak EUT RF output power, the minimum mobile separation distance, d=0.2 m, as well as the gain of the used antenna, the RF power density can be obtained. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E06 TRF:RT-4-E-006Page 7 of 7 2.2. Assess result Mode Output power (d…

Text truncated - open the document above for the full version.

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E05 TRF: RT-4-E-005Page 1 of 87 RADIO TEST REPORT Applicant : Harman International Industries, Inc. Address of Applicant : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Manufacturer : Harman International Industries, Inc. Address of Manufacturer : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Equipment under Test : 2.1 Channel Soundbar with Wireless Subwoofer Model No. : Bar 2.1 Essential HVIN : BAR2.1ESSSUB FCC ID : APIBAR21ESSSUB IC : 6132A-BAR21ESSSUB Test Standard(s) : FCC Rules and Regulations Part 15 Subpart C, ANSI C63.10-2020, RSS-247 Issue 4 July 24, 2025, RSS-Gen Issue 5, Apr. 2018, Amendment 2 (February 2021), ANSI C63.10-2020+Cor.1-2023+C63.10a- 2024+Errata to C63.10a-2024 Report No. : DDT-RE26012716-2E05 Issue Date : 2026/04/25 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E05 TRF: RT-4-E-005Page 2 of 87 Table of Contents 1.Summary of Test Results .............................................................................................7 2.General Test Information..............................................................................................8 2.1.Description of EUT .......................................................................................................8 2.2.Accessories of EUT......................................................................................................9 2.3.Block diagram of EUT configuration for test.................................................................9 2.4.Decision of final test mode ...........................................................................................9 2.5.Deviations of test standard.........................................................................................10 2.6.Test environment conditions ......................................................................................10 2.7.Test laboratory ...........................................................................................................10 2.8.Measurement uncertainty...........................................................................................11 3.Equipment Used During Conductive Test ..................................................................12 4.6 dB Bandwidth ..........................................................................................................13 4.1.Block diagram of test setup ........................................................................................13 4.2.Limits ..........................................................................................................................13 4.3.Test procedure ...........................................................................................................13 4.4.Test result...................................................................................................................14 4.5.Test graphs ................................................................................................................15 5.99% Bandwidth ..........................................................................................................17 5.1.Block diagram of test setup ........................................................................................17 5.2.Limits ..........................................................................................................................17 5.3.Test procedure ...........................................................................................................17 5.4.Test result...................................................................................................................18 5.5.Test graphs ................................................................................................................19 6.Maximum Peak Output Power....................................................................................21 6.1.Block diagram of test setup ........................................................................................21 6.2.Limits ..........................................................................................................................21 6.3.Test procedure ...........................................................................................................21 6.4.Test result...................................................................................................................22 6.5.Test graphs ................................................................................................................23 7.Power Spectral Density ..............................................................................................25 7.1.Block diagram of test setup ........................................................................................25 7.2.Limits ..........................................................................................................................25 7.3.Test procedure ...........................................................................................................25 7.4.Test result...................................................................................................................26 7.5.Test graphs ................................................................................................................27 8.Band Edge Compliance (Conducted Method)............................................................29 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE26012716-2E05 TRF: RT-4-E-005Page 3 of 87 8.1.Block diagram of test setup ........................................................................................29 8.2.Limits ................................................................................................…

Text truncated - open the document above for the full version.

Test Report

V0.1 20231127 Addr: Qunle Industrial Area East ShaGang Road GangKou ZhongShan 1 / 4 Tel : +86 (760) 89923666 Fax: +86 (760) 89923669 Antenna Specification Quick Reference Date Antenna on the system board Frequency Range 2400 ~ 2500MHz Ant. Port Input Pwr. (dBm) 2 (Typ. BT class2 output power) Efficiency ((%) >50% Maximum Power (dBi) 0.64 Input Impendence (ohm) 50 Polarization Type Vertical & Horizontal V.S.W.R < 1.5 All the technical data and information contained herein are subject to change without prior notice Antenna Layout on the system board Antenna Gain V0.1 20231127 Addr: Qunle Industrial Area East ShaGang Road GangKou ZhongShan 2 / 4 Tel : +86 (760) 89923666 Fax: +86 (760) 89923669 Return Loss V0.1 20231127 Addr: Qunle Industrial Area East ShaGang Road GangKou ZhongShan 3 / 4 Tel : +86 (760) 89923666 Fax: +86 (760) 89923669 The Environment of Antenna Radiation Pattern V0.1 20231127 Addr: Qunle Industrial Area East ShaGang Road GangKou ZhongShan 4 / 4 Tel : +86 (760) 89923666 Fax: +86 (760) 89923669

Contact Information

Applicant

Terry Shi(Prin.Engineer,Regulatory Compliance, Quality)
[email protected]Fax: 818-892-0325

Technical Contact

Harman International Industries, IncTerry Shi
[email protected]

8500 Balboa Boulevard, Northridge, CA · Northridge, 91329 · United States

Test Firm

Guangdong Dongdian Testing Service Co., Ltd.Mr. Jamy Yu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz9.08 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Harman International Industries, Inc

APISB595MK2

3.1.2 Channel Soundbar with True Dolby Atmos and Wireless Subwoofer

Aug 27, 2026

Equipment Class

DTS - Digital Transmission System
APITUNEBEAM3

BLUETOOTH HEADSET

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System
APITUNEBUDS3

BLUETOOTH HEADSET

Jul 30, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
APITUNEFLEX3

BLUETOOTH HEADSET

Jul 29, 2026

Equipment Class

DTS - Digital Transmission System
APIJBLVBUDS3

BLUETOOTH HEADSET

Jul 21, 2026

Equipment Class

DTS - Digital Transmission System