Harman International Industries, Inc Covered Equipment Certification Attestation Letter 2024-06-13 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID:APIJR470NC Harman International Industries, Inc (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List , the applicant should include an explanation on why the equipment is not “covered” equipment. Harman International Industries, Inc (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Terry Shi Title: Senior Prin.Engineer,Regulatory Compliance, Quality Company Name: Harman International Industries, Inc Address: 8500 Balboa Boulevard, Northridge, CA 91329, United States Phone: 86-75523189391 E-Mail: [email protected] Date: 2024-06-13
HarmanInternationalIndustries,Inc HarmanInternationalIndustries,Inc 8500 BalboaBoulevard,Northridge,CA 91329,UnitedStates , Northridge,CA 91329,United States FederalCommunicationCommission Authorizationand EvaluationDivision 7435OaklandMillsRoad Columbia,MD 21046 USA 2024- 06 -13 AttestationStatementaccordingto 2.911(d)(7) FCC ID: APIJR470NC TO WHOMIT MAYCONCERN: We, HarmanInternationalIndustries,Inc designateourselvesto act as U.S. agentfor serviceof process. HarmanInternationalIndustries,Inc herebyacknowledgesthe obligationof the U.S. agentfor serviceof process.Further HarmanInternationalIndustries,Inc acceptsto maintainan agentfor no less thanone year afterthe granteehas terminatedall marketingand importationor the conclusionof any Commission-relatedproceedinginvolvingthe equipment. Sincerely Signature: Companyname:HarmanInternationalIndustries,Inc FRN:0024748147 Address:8500BalboaBoulevard,Northridge,CA 91329,UnitedStates ContactPerson:TerryShi TelephoneNo: 86-75523189391 Email:[email protected]
Harman International Industries, Inc 2024-06-13 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appointDamon Hu,Guangdong Dongdian Testing Service Co.,Ltd.(Unit 2, Building 1, No.17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808) , to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still residesstill resides with us. Sincerely, Printed name: Terry Shi Title: Senior Prin.Engineer,Regulatory Compliance, Quality Company Name: Harman International Industries, Inc Address: 8500 Balboa Boulevard, Northridge, CA 91329, United States Phone: 86-75523189391 E-Mail: [email protected] Date: 2024-06-13
Harman International Industries, Inc 2024-06-13 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY – FCC FCC ID: APIJR470NC Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules andFCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period ofinsert number of 180 days (cannot exceed 180 days)days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence beforethe requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. ExhibitType of Confidentiality Requested Block Diagrams ☒Permanent ☐Short Term External Photos------------------☒Short Term Internal Photos☐Permanent*☒Short Term Operation Description ☒Permanent ☐Short Term Parts List & Placement/BOM ☐Permanent☐Short Term Tune-Up Procedure ☒Permanent ☐Short Term Schematic Diagrams☒Permanent ☐ Short Term Test Setup Photos------------------☒Short Term User’s Manual ☐ Permanent* ☒Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731and review section II, 3) regarding specific information that must accompany these requests. Note:any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Terry Shi Title: Senior Prin.Engineer,Regulatory Compliance, Quality Company Name: Harman International Industries, Inc Address: 8500 Balboa Boulevard, Northridge, CA 91329, United States Phone: 86-75523189391 E-Mail: [email protected] Date: 2024-06-13
Right side Right ear-cup Left side 左/右伸缩臂,模刻凸字哑光 高度由结构确认 右耳壳,模刻凹字高光 高度由结构确认 7.5877±0.0100 31.7969±0.0100 7.5877±0.0100 31.6560±0.0100 垃圾桶实际模刻最小高度不低于5mm 总标识实际模刻的 最小高度不低于7mm 色块实际模刻高度必须大于1 mm 5.17mm 7.25mm 1mm 实际模刻最小高度不低于5mm 5.1mm 实际模刻,最小宽度、高度不低于5 mm 5mm 实际模刻最小高度不低于5mm 5.1mm 3.7mm 4.76mm 0.68mm 3.02 mm 实际模刻最小高度不低于3mm 3.93mm 4.97mm 0.84mm 5.1mm 实际模刻KCC logo 最小高度不低于5mm
JR470 BT Antenna report Applicant Tonly Technology Co., Ltd. Address Section 37, Zhongkai High-tech Development Zone, Huizhou City, Guangdong Province, 516006 China Manufacturer or Supplier Tonly Technology Co., Ltd. Address Section 37, Zhongkai High-tech Development Zone, Huizhou City, Guangdong Province, 516006 China Product PCB Brand Name Tonly Model JR470 Max. Peak Gain 3.36dBi Date of tests 2024-4-17 Tested by gan.zhou 周赣 1. Test standard Name Parameter Method Standard no. Antenna performance Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 2. Equipment list Equipment Manufacturer Model No Serial No. Last Cal. Due Date Network Aanlyzer Agilent E5071C MY46630767 2023.4.27 2024.4.26 Microwave chamber GTS GTS Maxsign- Dart7000 2023.4.27 2024.4.26 Turn table GTS Dart-700 turn table 2023.4.27 2024.4.26 turn table controller GTS Dart-700 turn table controller 2023.4.27 2024.4.26 Broad-Band Horn Antenna GTS AT-6000 MA-D0460 2023.4.27 2024.4.26 Test Software GTS Libra Version- 3.0.3.1 2023.4.27 2024.4.26 3. Antenna Size(mm) 4. Antenna photo (Please refer to Antenna photos document) 5.Test setup photo(Please refer to Antenna photos document) 6.Test configuration diagram Test step flow: 1) Maintain the test ambient temperature of 23±2 C, the instrument is powered on and preheated for more than 30 minutes; 2) Turn on the darkroom power supply, connect the test cable, and set up the sample according to the standard; 3) Outline sets the test content objectives and conducts calibration tests; 4) Run the software, when the test is completed, export the corresponding test diagram and test data, and save to the corresponding directory. 7.Antenna gain(head model) Freq(MHz) Efficiency(%) Gain(dBi) 2400 39.77 2.97 2410 42.56 3.3 2420 41.9 3.34 2430 41.71 3.36 2440 39.32 3.13 2450 37.22 2.9 2460 37.72 2.87 2470 39.55 2.92 2480 40.96 2.96 2490 43.57 3.11 2500 40.91 2.65 8.Antenna test data(3D) 8.Antenna test data(2D)
Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE24042219-2E07 TRF No.: RT-4-E-02-601 FCC SAR Test Report Ver.1.1 Page 1 of 28 FCC AND ISED SAR TEST REPORT Applicant : Harman International Industries, Inc. Address of Applicant : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Manufacturer : Harman International Industries, Inc. Address of Manufacturer : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Equipment under Test : BLUETOOTH HEADSET Model No. : JUNIOR 470NC FCC ID : APIJR470NC IC : 6132A-JR470NC Test Standard(s) : Test Standard Used: IEEE Std. 1528-2013; IEC/IEEE 62209-1528:2020 FCC Rules and Regulations: 47 CFR § 2.1093 ISED Rules and Regulations: RSS-102 Issue5, Mar. 2015 Test Procedure Used: KDB447498 D04 v01, KDB 865664 D01 v01r04, KDB 865664 D02 v01r02 Report No. : DDT-RE24042219-2E07 Issue Date : 2024/06/03 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Address of Laboratory : Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE24042219-2E07 TRF No.: RT-4-E-02-601 FCC SAR Test Report Ver.1.1 Page 2 of 28 Table of Contents 1. General test information ...................................................................................................... 6 1.1. Description of EUT .............................................................................................................. 6 1.2. Accessories of EUT ............................................................................................................. 6 1.3. Assistant equipment used for test ....................................................................................... 6 1.4. Block diagram of EUT configuration for test ....................................................................... 6 1.5. Test environment conditions ............................................................................................... 6 1.6. Test laboratory .................................................................................................................... 7 2. Summary of test results ...................................................................................................... 8 2.1. Report SAR results ............................................................................................................. 8 2.2. RF exposure limits .............................................................................................................. 8 3. SAR measurements system configuration .......................................................................... 9 3.1. The SAR measurement system .......................................................................................... 9 3.2. Isotropic E-field probe EX3DV4 ........................................................................................ 10 3.3. SAM twin phantom ............................................................................................................ 10 3.4. ELI phantom ...................................................................................................................... 11 3.5. Data acquisition electronics (DAE) ................................................................................... 11 3.6. Device holder for transmitters ........................................................................................... 12 4. Measurement procedure ................................................................................................... 13 4.1. Scanning procedure .......................................................................................................... 13 5. Description of test position ................................................................................................ 15 5.1. Body-worn accessory configurations ................................................................................ 15 5.2. Extremity exposure configurations .................................................................................... 16 6. RF exposure conditions .................................................................................................... 17 6.1. EUT Test sides .................................................................................................................. 17 6.2. Standalone SAR test exclusion considerations ................................................................ 17 7. SAR system verification procedure ................................................................................... 19 7.1. Tissue simulate liquid ........................................................................................................ 19 7.1.1. Target dielectric properties of head tissue-equivalent material ........................................ 19 7.1.2. Measurement for tissue simulate liquid ............................................................................ 19 7.2. SAR system validation ...................................................................................................... 21 7.2.1. Justification for extended SAR dipole calibrations ............................................................ 22 7.2.2. Validation test setup photograph ...................................................................................... 22 7.2.3. Summary system validation results .................................................................................. 23 7.2.4. Detailed system validation results ..................................................................................... 23 8. Equipment list .................................................................................................................... 24 9. Measurement uncertainty .................................................................................................. 25 Guangdong Dongdian Testing Service Co., Ltd. Report No.: DDT-RE24042219-2E07 TRF No.: RT-4-E-02-601 FCC SAR Test R…
Text truncated - open the document above for the full version.
Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 1 of 3 Appendix A System Validation Plots Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 2 of 3 Table of Contents 1. D2450V2-SN: 904 Validation Plot ..................................................................................... 3 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 3 of 3 1. D2450V2-SN: 904 Validation Plot
Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 1 of 3 Appendix B Highest Test Plots Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 2 of 3 Table of Contents 1. BT Head-worn 0mm SAR ....................................................................................................... 3 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 3 of 3 1. BT Head-worn 0mm SAR
Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 1 of 30 Appendix C Calibration Certification Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 2 of 30 Table of Contents 1. D2450V2-SN: 904 Calibration certification ............................................................................. 3 2. D5GHzV2-SN: 1148 Calibration certification .......................................................................... 9 3. DAE4-SN: 1366 Calibration certification............................................................................... 19 4. EX3DV4-SN: 3906 Calibration certification .......................................................................... 22 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 3 of 30 1. D2450V2-SN: 904 Calibration certification Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 4 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 5 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 6 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 7 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 8 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 9 of 30 2. D5GHzV2-SN: 1148 Calibration certification Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 10 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 11 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 12 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 13 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 14 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 15 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 16 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 17 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 18 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 19 of 30 3. DAE4-SN: 1366 Calibration certification Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 20 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 21 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 22 of 30 4. EX3DV4-SN: 3906 Calibration certification Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 23 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 24 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 25 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 26 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 27 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 28 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 29 of 30 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 30 of 30
Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 1 of 5 Appendix D Test setup photograph Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 2 of 5 Table of Contents 1. 2.4G Tissue Head-worn Photograph ...................................................................................... 3 Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 3 of 5 1. 2.4G Tissue Head-worn Photograph Top Side-0mm Bottom Side-0mm Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 4 of 5 Left Side-0mm Right Side-0mm Guangdong Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-RE24042219-2E07 Page 5 of 5 Front side-0mm Back Side-0mm
Guangdong Dongdian Testing ServiceCo.,Ltd. Page 1 of 5 Appendix E Dipole Antenna self-calibration Guangdong Dongdian Testing ServiceCo.,Ltd. Page 2 of 5 Table of Contents 1. Calibration Date ...................................................................................................................... 3 2. Calibration Items ..................................................................................................................... 3 3. Standards ................................................................................................................................ 5 4. Laboratory ............................................................................................................................... 5 5. Calibration Results .................................................................................................................. 5 Guangdong Dongdian Testing ServiceCo.,Ltd. Page 3 of 5 1. Calibration Date Calibration Date Oct.20,2023, Due to Oct.19,2024 2. Calibration Items Dipole Antenna self-calibration 1、 Calibration Method Immediate re-calibration is required for the following conditions. 1) According to KDB 865664 D01, When the most recent return-loss result, measured at least annually, deviates by more than 20% from the previous measurement (i.e. value in dB 0.2) or not meeting the required 20 dB minimum return-loss requirement. 2) When the most recent measurement of the real or imaginary parts of the impedance, measured at least annually, deviates by more than 5 Ω from the previous measurement. 3)When the measured SAR deviates from the calibrated SAR value by more than 10% due to changes in physical, mechanical, electrical or other relevant dipole conditions; i.e., the error is not introduced by incorrect measurement procedures or other issues relating to the SAR measurement system. 2、 Calibration Purpose Demonstrate that SAR target, the impedance and return loss of the dipole remain stable as required 3、 Test The Product Manufacturer Speag Name 2450MHz Dipole antenna Model number D2450V2 Environment temperature 20.8°C Look pictures As shown in figure 1 Manufacturer Speag Name 5GHz Dipole antenna Model numbe D5GHZV2 Environment temperature 20.8°C Look pictures As shown in figure 2 Guangdong Dongdian Testing ServiceCo.,Ltd. Page 4 of 5 Figure 1 Test signal source Figure 2 Test signal source Guangdong Dongdian Testing ServiceCo.,Ltd. Page 5 of 5 3. Standards This antenna calibration is conducted according to KDB 865664 D01 4. Laboratory The following personnel participated in this laboratory: Table 1: Participate in the measurement laboratory Laboratory Name Temp°C Test person Guangdong Dongdian Testing Service Co., Ltd. 20.8°C Johnson Huang 5. Calibration Results The quality control test results are shown in Table 2 and Table 3, and the detailed test data is in the attachment Table 2 Calibrated Antenna Target Return loss Test Return loss Deviation Result 2450 -28.825 -28.394 1.50% OK 5200 -24.780 -20.041 19.12% OK 5300 -24.151 -27.179 12.54% OK 5500 -23.082 -25.183 9.10% OK 5600 -22.239 -23.471 5.54% OK Table 3 Calibrated Antenna Target Impedance (Real) Target Impedance (Imaginary Test Impedance (Real) Test Impedance (Imaginary) Deviation (Real) Deviation (Imaginary) Result 2450 53.391 1.586 50.607 2.878 2.784 1.292 OK 5200 49.477 -8.009 52.310 -8.448 2.833 0.439 OK 5300 54.645 -5.723 49.946 -3.293 4.699 2.43 OK 5500 56.887 -4.538 52.061 -5.591 4.826 1.053 OK 5600 56.214 -5.378 52.520 -4.505 3.694 0.873 OK
Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE24042219-2E02 TRF No.: RT-4-E-02-001 RF test report Ver. 1.0 Page 1 of 85 FCC AND ISED CERTIFICATION TEST REPORT Applicant : Harman International Industries, Inc. Address of Applicant : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Manufacturer : Harman International Industries, Inc. Address of Manufacturer : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Equipment under Test : BLUETOOTH HEADSET Model No. : JUNIOR 470NC FCC ID : APIJR470NC IC : 6132A-JR470NC Test Standard(s) : FCC Rules and Regulations Part 15 Subpart C, RSS-247 Issue 3 August 2023, ANSI C63.10:2013, RSS-Gen Issue 5, Apr. 2018, Amendment 2 (February 2021) Report No. : DDT-RE24042219-2E02 Issue Date : 2024/06/03 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE24042219-2E02 TRF No.: RT-4-E-02-001 RF test report Ver. 1.0 Page 2 of 85 Table of Contents 1. Summary of Test Results ............................................................................................. 7 2. General Test Information .............................................................................................. 8 2.1. Description of EUT ........................................................................................................ 8 2.2. Accessories of EUT ...................................................................................................... 9 2.3. Block diagram of EUT configuration for test ................................................................. 9 2.4. Decision of final test mode ........................................................................................... 9 2.5. Deviations of test standard ......................................................................................... 10 2.6. Test environment conditions ....................................................................................... 10 2.7. Test laboratory ............................................................................................................ 10 2.8. Measurement uncertainty ........................................................................................... 11 3. Equipment Used During Conductive Test .................................................................. 12 4. 6 dB Bandwidth ........................................................................................................... 13 4.1. Block diagram of test setup ........................................................................................ 13 4.2. Limits ........................................................................................................................... 13 4.3. Test procedure ............................................................................................................ 13 4.4. Test result ................................................................................................................... 14 4.5. Test graphs ................................................................................................................. 15 5. 99% Bandwidth ........................................................................................................... 17 5.1. Block diagram of test setup ........................................................................................ 17 5.2. Limits ........................................................................................................................... 17 5.3. Test procedure ............................................................................................................ 17 5.4. Test result ................................................................................................................... 18 5.5. Test graphs ................................................................................................................. 19 6. Maximum Peak Output Power .................................................................................... 21 6.1. Block diagram of test setup ........................................................................................ 21 6.2. Limits ........................................................................................................................... 21 6.3. Test procedure ............................................................................................................ 21 6.4. Test result ................................................................................................................... 22 6.5. Test graphs ................................................................................................................. 23 7. Power Spectral Density .............................................................................................. 25 7.1. Block diagram of test setup ........................................................................................ 25 7.2. Limits ........................................................................................................................... 25 7.3. Test procedure ............................................................................................................ 25 7.4. Test result ................................................................................................................... 26 7.5. Test graphs ................................................................................................................. 27 8. Band Edge Compliance (Conducted Method) ............................................................ 29 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE24042219-2E02 TRF No.: RT-4-E-02-001 RF test report Ver. 1.0 Page 3 of 85 8.1. Block diagram of test setup ........................................................................................ 29 8.2. Limits ....…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 3.34 mW |
BLUETOOTH HEADSET
Equipment Class
DTS - Digital Transmission SystemBLUETOOTH HEADSET
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterBLUETOOTH HEADSET
Equipment Class
DTS - Digital Transmission SystemBLUETOOTH HEADSET
Equipment Class
DTS - Digital Transmission SystemPORTABLE BLUETOOTH SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter