FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Gorko Systems Inc./
  3. AUF-S1

AUF-S1BATTERY POWERED WIRELESS MULTIFUNCTION SENSOR

Gorko Systems Inc.
BATTERY POWERED WIRELESS MULTIFUNCTION SENSOR - FCC ID AUF-S1 - Gorko Systems Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 12, 2012
Application Purpose
Original Equipment
Date of Application
Jun 12, 2012
Equipment Note
BATTERY POWERED WIRELESS MULTIFUNCTION SENSOR
Frequency Range
2405.00000000 - 2480.00000000
Company
Gorko Systems Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

(((MiWSN))) Wireless Sensors Network Mi-Sensor-1 and Mi-Gateway-1 User Manual MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc 1/14 Contents Certifications (FCC and IC) ____________________________________________________ 1 1Mi-Sensor-1 ______________________________________________________________ 2 1.1Sensor Introduction ______________________________________________________ 2 1.2Battery Installation ______________________________________________________ 2 1.3Sensor Installation _______________________________________________________ 2 1.4Sensor Notifications______________________________________________________ 3 1.5Sensor Precautions ______________________________________________________ 3 2Mi-Gateway-1 ____________________________________________________________ 4 2.1Gateway Introduction ____________________________________________________ 4 2.2Gateway Installation _____________________________________________________ 4 2.3Gateway Reset __________________________________________________________ 4 2.4Gateway Repeater Function _______________________________________________ 4 2.5Gateway Web Management Interface ________________________________________ 5 2.6Gateway Login Authentication _____________________________________________ 5 2.7Setup Page _____________________________________________________________ 6 2.8Rebooting Page _________________________________________________________ 8 2.9Configure Page _________________________________________________________ 8 2.10 Configuring Page _______________________________________________________ 10 2.11 Status Page ____________________________________________________________ 11 2.12 Help Page _____________________________________________________________ 12 Warranty Information ________________________________________________________ 13 Limitation of Warranty and Remedies. ___________________________________________ 13 Certifications (FCC and IC) Contains Mi-Sensor-1 FCC ID: AUF-S1 and Mi-Gateway-1 FCC ID: AUF-G1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Contains Mi-Sensor-1 IC: 10170A-S1 and Mi-Gateway-1 IC: 10170A-G1 This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc 2/14 1Mi-Sensor-1 1.1 Sensor Introduction The Mi-Sensor-1 is a multifunction battery powered wireless sensor that is capable of simultaneously monitoring Temperature, Motion, and Moisture present or Contact closure 1.2Battery Installation Open sensor by prying case open by hand. Insert CR2032 battery in holder ensuring to observe polarity indicator on battery and battery holder. WARNING – Incorrect installation will damage sensor and void warranty. 1.3Sensor Installation Configure sensor using gateway CONFIGURE page. See gateway sensor configuring section for details. Test sensor signal strength at the location the sensor is intended to be use by pressing the test button on the sensor and viewing the sensor message signal strength (RSSI) on the gateway STATUS page. If signal strength is too low or the gateway is unable to receive the sensor test message, try adjusting the sensor and gateway orientation, and location. For temperature and motion sensing, the sensor only needs to be placed in a suitable location. If the sensor is being use to sense the presence of a liquid or contact closure, attach the supplied sensing wire to the sensor moisture/contact terminal block. Each of the two wires of one end is inserted into the two larger terminal block holes. You may use your own supplied 18- 24 AWG wire if the supplied wire is not suitable for your application. To release the wire from the terminal block, insert a pin into the two smaller slots of the terminal block. For moisture sensing, the other ends of the wire should be spaced about 3mm (1/8 inch) apart and placed in a location they can come in contact with the liquid. For contact sensing, the other ends of the wire should be attached to a dry contact closure element such as a door open/close contact containing a reed switch. Attach double sided tape to sensor and attach sensor in final sensing location. MiWSN User Manual Rev 1 – Copyright Gorko Systems Inc 3/14 1.4 Sensor Notifications The sensors will send notifications to the email account specified in the gateway Setup page. Notifications consist of alarm conditions or periodic reports as defined in the Configure Page of the gateway and configured into the sensor. Notifications are delivered as emails or phone texts with the subject line fields separated by comas and formatted as follows: FieldDescription 1Indicates the message is from a MiWSN1 network. 2Indicates the message type. Types are; Test – the test button on the sensor was pressed. Alarm – an alarm notification condition exists with Motion, Cntct, Bat, or Temp Report – send periodically if configured. Reset – the sensor battery was inserted, or a battery is very low. 3The gateway name plus the sensor name plus an event number signifying where the message came from. The event number is incremented each time the sensor sends a message. 4Motion = indicates Yes there is motion or No motion. 5Cntct = indicates Yes if there is moisture or contacts are closed and No if the contacts are dry or open. 6Bat = indicates if the battery is OK or Low. A low battery should be replaced. 7Temp = indicates the current temperature. C indicates Celsius and F indicates Fahrenheit. 8RSSI= indicates the signal strength of the message received by the gateway. The farther away from the gateway the sensor gets, the …

Text truncated - open the document above for the full version.

Block Diagram

Microcontroller WSN Sensor Block Diagram, Rev1, Gorko Systems Inc. Temperature Sensor Accelerometer 3V Battery RF Module 16Mhz 32Mhz

Cover Letter(s)

Gorko Systems Inc. 132 Southbend Cres. Winnipeg, Manitoba R3Y 1K7 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: AUF-S1 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit TypeFile Name GSI WSNS SchematicGSI WSNS Schematic.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Gord Boyechko

External Photos

FCC ID: AUF-S1 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 1 of 2 External Photos Bottom view. Top view, opening side. FCC ID: AUF-S1 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 2 of 2 Top view, opening side close-up. Top view, side 2.

ID Label/Location Info

(((WiWSN))) www.miwsn.com MODEL: Mi-Sensor-1 FCCID: AUF-S1 IC: 10170A-S1

Operational Description

Gorko Systems Inc. WSNS FCC ID: AUF-S1 872 UC12 Page 1 of 2 Report PR12-0055 Operational Description A 3V lithium battery is inserted into the sensor and the Microcontroller (MCU) receives a power on reset. The MCU initializes its functions using values stored in EEPROM. The MCU communicates with the RF Module using SPI protocol and puts it into a low power sleep mode. The Accelerometer is configured using an I2C interface to produce a wakeup on excessive shock. An ADC is done on the Temperature Sensor analog output. The MCU processor periodically wakes up and checks all of the sensors. If there is an alarm condition on a sensor, a 1ms message is sent using the RF module. The WSNS can also periodically (programmable 1- 9999 minutes) send a status message. The RF Module consists of an IEEE 802.15.4 transceiver chip, balun, and ¼ wave board printed tilted whip antenna. The antenna radiates off board printed ground plain. Wireless Sensor Network Products Battery powered sensors monitor temperature, motion, moisture, and contact closure. The sensors send notifications to the gateway wirelessly. Using an Ethernet connection, the gateway relays notifications to an email account or text phone via the Internet. All sensors and gateway administration is done via web browser. The system is self-monitored and there are no monthly fees or special server software required. All that is required is at least one Mi-Sensor-1, at least one Mi-Gateway-1, an Internet connection, and an email account to perform your own asset monitoring. Mi-Sensor-1 Specifications User configurable notifications of Temperature exceeded, Motion present, Moisture present or Contact closure, and low battery condition. User configurable periodic reporting interval of 0 to 9999 minutes. User configurable sensor name. User accessible test button for sending test message and configuring sensor. Moisture/Contact sensing wire may be 2m long. 16 channel 2.4Ghz operating frequency with FCC and IC approvals. Integrated antenna with up to 100m open air operating range. Size 4cm x 4cm x 1.5cm and Weight 15g. User replaceable CR2032 battery with approximately 4 year life. Gorko Systems Inc. WSNS FCC ID: AUF-S1 872 UC12 Page 2 of 2 Report PR12-0055 Mi-Gateway-1 Specifications Unlimited Sensors per Gateway. Web interface for user administration and status. Setup screen for Network IP, Host name, MAC address, Email parameters, RF channel and key. Configuration screen for setup of Sensor parameters. Status screen displays log of last 10 sensor notifications. SSL email delivery of encrypted wireless sensor notifications. User accessible test button for resetting network parameters. 16 channel 2.4Ghz operating frequency with FCC and IC approvals. Integrated antenna with up to 100m open air operating range. RJ45 Ethernet interface to LAN. Size 4cm x 8cm x 2cm and Weight 30g. 5V 200mA power requirement (AC/DC adapter supplied). Copyright – Gorko Systems Inc

Test Report

Record of Measurements Rev 1.5 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 1 of 16 Gorko Systems WSNS Sensor Record of Measurements FCC CFR47 Part 15 Subpart C §15.247 & IC RSS-210 Revision 1.5 June 8, 2012 June 8, 2012 Protocol Data Systems Inc, EMC Lab, Abbotsford BC, Canada. SCC ISO/17025 (CAN-P-4E) Accredited Laboratory No. 631 FCC O.A.T.S. Registration Number 96437 Industry Canada O.A.T.S. Registration Number IC3384A-1 This report is for the exclusive use of Protocol Data Systems Customer and is provided pursuant to the agreement between Protocol and its Customer. Protocol's responsibility and liability are limited to the terms and conditions of the agreement. Protocol assumes no liability to any party, other than to the Customer in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Customer is authorized to copy or distribute this report and then only in its entirety. Any use of the Protocol Data Systems name for the sale or advertisement of the tested material, product or service must first be approved in writing by Protocol Data Systems. The observations and test results in this report are relevant only to the sample/s tested. Record of Measurements Rev 1.5 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 2 of 16 Index Section I: Report of Measurements Testing Information ..................................................................... 3 Section II: Report of Measurements Test Procedure ........................................................................... 5 Section III: Maximum Conducted Output Power .................................................................................... 8 Section IV: Measurements of Power Spectral Density ........................................................................... 9 Section V: Measurement of 6dB Bandwidth ........................................................................................ 10 Section VI: Measurement of Band Edges ............................................................................................ 11 Section VII: Restricted Bands of Operation........................................................................................... 13 Section VIII: Measurements of Transmitter Spurious Emissions ........................................................... 15 Record of Measurements Rev 1.5 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 3 of 16 Section I: Report of Measurements Testing Information GENERAL INFORMATION: Applicant Company Name Gorko Systems Address 132 Southbend Crescent Winnipeg, MB R3Y 1K7 Phone: 204-228-5703 Contact Person Mr. Gordon Boyechko Email [email protected] Product Name WSNS Wireless Sensor FRN 0021455464 Applicable Standard FCC Part 15.247 Test Results Pass Statement of Compliance This equipment has been tested in accordance with the standards identified in the referenced test report. To the best of our knowledge and belief, these tests were performed using the measurement procedures described in this report and demonstrate that the equipment complies with the appropriate standards. – Signature on Front Cover Page. EQUIPMENT UNDER TEST SPECIFCATIONS: Manufacturer Gorko Systems Product Description Wireless Temperatiure Sensor FCC ID AUF-S1 IC Number 10170A-S1 Model Number WSNS Name Wireless Temperatiure Sensor Operating Frequency 2.405- 2.480 GHz Emission Designator 760KK7D EUT Power Source 3 V Coin Cell Test Item Production Unit Type of Equipment Fixed Test Voltage 3 Vdc TEST FACILITY: Test Facility Protocol Data Systems Inc. 4741 Olund Rd. Abbotsford, BC V4X 1V6 Phone: 604-504-0091 Fax: 604-554-0091 Email: [email protected] Website: www.protocol-emc.com Test Facility ID’s SCC ISO/17025 (CAN-P-4E) Accredited Laboratory No. 612 FCC O.A.T.S. Registration Number 627740 Industry Canada O.A.T.S. Registration Number IC3384 Dates Tested February 23, 29, March 4, May 12, 2012 Tested By Rob Stirling Record of Measurements Rev 1.5 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 4 of 16 TEST SET-UP: Test Exercise E.g. software description, test signal, etc. The EUT was set for continuous transmit mode of operation. Deviation from Standard/s No deviation from Standard Modification to the EUT No modifications were made. TEST EQUIPMENT LIST Manufacturer Model Equipment Description Serial No. Next Cal HP 85650A CDN Quasi-Peak Adapter 2811A01080 12/08/12 HP 85662A Spectrum Analyzer Display 2152A03569 11/08/12 HP 8566B Spectrum Analyzer RF Section 2241A02102 11/08/12 HP 85685A RF-Preselector 3107A01222 11/08/12 EMCO 3146 Ant Log Periodic 200-1000MHZ 9611-4699 08/08/12 EMCO 3110B Ant Biconical 20-300MHz 9401-1850 08/08/12 EMCO 3115 Horn Antenna 1-18GHz 9403-4251 20/08/12 EMCO 3825/2 LISN 2470 20/07/12 Rhientech Custom Antenna Mast N/A N/A Protocol EMC Custom Turntable N/A N/A HP 362 Controller 6452A40248 N/A EMCO 6502 Loop Antenna 9kHz-30MHz 9002-2489 18/6/12 HP 11970K Mixer 3003A0SSSA N/A MI Technologies Horn Antenna 18-26.5 GHz N/A HP 11975A Amplifier 2517A00440 MEASUREMENT UNCERTAINTY Parameter Uncertainty Radio Frequency ±1 x 10-5 Total RF power, conducted ±1,5 dB RF power density, conducted ±3 dB Spurious emissions, conducted ±3 dB All emissions, radiated ±3 dB Temperature Humidity ±5 % DC and low frequency voltages ±3 % Record of Measurements Rev 1.5 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 5 of 16 Equipment Under Test THE TEST SYSTEM: EUT: Wireless Remote Temperature Sensor Manufacturer: Gorko Serial Number: Test1 Part Number WSNS WSNS Record of Measurements Rev 1.5 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 6 of 16 Section II: Report of Measurements Test Procedure RADIATION INTERFERENCE: The measurement was made per ANSI C63.4-2003 using an Agilent model 8566B spectrum analyzer, a model 85685A Preselector, a model 85650A quasi-peak adapter, and the appropriate antenna. The analyzer was calibrated in dB above a microvolt at the output of the antenna. The resolutio…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: AUF-S1 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 1 of 3 Test Setup Photos Test Setup for Spurious Radiated Emissions Frequencies below 30 MHz. FCC ID: AUF-S1 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 2 of 3 Test Setup for Spurious Radiated Emissions on OATS. Test Setup for Spurious Radiated Emissions 1 to 18 GHz. FCC ID: AUF-S1 Gorko Systems WSNS Sensor Report Number: PR12-0055 Page 3 of 3 Test Setup for Spurious Radiated Emissions Frequencies above 18 GHz.

Contact Information

Applicant

Gordon Boyechko(CEO)
[email protected]204-228-5703Fax: 204-228-5703

Test Firm

Protocol Data Systems Inc.Robert Stirling
[email protected]6042181762

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz100.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Gorko Systems Inc.

5VDC POWERED WIRELESS TO INTERNET GATEWAY - FCC ID AUF-G1 - Gorko Systems Inc.
AUF-G1

5VDC POWERED WIRELESS TO INTERNET GATEWAY

Jun 12, 2012

Equipment Class