Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Request for Confidentiality September 14, 2001 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID:AZPFP-T3FR-72 Please be advised that the following information is to be held confidential and behalf of Futaba Corporation: • Block Diagram • Schematics • Description of Operation The application contains technical information which Futaba Corporation deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Signatory Johann Roidt
FCC ID: AZPFP-T3FR-72External Photos Page 1 of 2 FCC ID AZPFP-T3FR-72 External Photographs FCC ID: AZPFP-T3FR-72External Photos Page 2 of 2
EMV-PrüfzentrumEMI/EMC-Testcenter FCC ID: AZPFP-T3FR-72 Label Information
FCC ID: AZPFP-T3FR-72Internal Photos Page 1 of 3 FCC ID AZPFP-T3FR-72 Internal Photographs FCC ID: AZPFP-T3FR-72Internal Photos Page 2 of 3 FCC ID: AZPFP-T3FR-72Internal Photos Page 3 of 3
EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: AZPFP-T3FR-72Test Report No. 55503-10420-1 Page 1 of 59 Pages Straubing, July 30, 2001 T E S T - R E P O R T No. 55503-10420-1 for T3FR-72 R/C Transmitter Variant covered by this test report: T2FR-72 Applicant:Futaba Corporation Purpose of testing:To show compliance with - FCC Code of Federal Regulations, CFR 47, Part 95 - FCC Code of Federal Regulations, CFR 47, Part 2, Subpart J Note: The test data of this report relate only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: AZPFP-T3FR-72Test Report No. 55503-10420-1 Page 2 of 59 Pages Table of Contents 1. Administrative Data ..............................................................................................3 2. Identification of Test Laboratory ...........................................................................4 3. Summary of Test Results.....................................................................................5 4. Operation Mode of EUT .......................................................................................6 5. Configuration of EUT and Peripheral Devices ......................................................7 6. Measuring Methods..............................................................................................8 6.1. Maximum Transmitter Power (ß95.639) ........................................................8 6.2. Frequency tolerance (ß95.623) ...................................................................10 6.3. Emission Bandwidth (ß95.633) ....................................................................12 6.4. Unwanted Emission 30 MHz - 1 GHz (ß95.635, ß95.639) ...........................13 7. Equipment List ...................................................................................................15 8. Referenced Regulations.....................................................................................17 9. List of Measurements.........................................................................................18 10. List of Measurements.........................................................................................19 11. Test Results .......................................................................................................20 12. Additional Results ..............................................................................................30 EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: AZPFP-T3FR-72Test Report No. 55503-10420-1 Page 3 of 59 Pages 1.Administrative Data Equipment Under Test (EUT):T3FR-72 Variant covered by this report:T2FR-72 Serial number(s):01043 Type of equipment:R/C Transmitter Type of emission:A1D Parts/accessories:--- FCC-ID:AZPFP-T3FR-72 Applicant:Futaba Corporation (full address)R/C Engineering Unit 1 1080, Yabutsuka Chosei-son, Chosei-gun, Chiba-ken, 299-4395 Japan Contract identification:--- Contact person:Mr. Nobumitsu Kanetsuna Manufacturer:Futaba Corporation Receipt of EUT:June19, 2000 Dates of test:July 18 to 20, 2001 Note:--- Responsible for testing:Thomas Eberl Responsible for test report:Thomas Eberl EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: AZPFP-T3FR-72Test Report No. 55503-10420-1 Page 4 of 59 Pages 2.Identification of Test Laboratory Test Laboratory:Senton GmbH EMI/EMC Test Center (full address):Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Contact person:Mr. Johann Roidt Communication:Telephone(+49) 0 94 21 / 55 22-0 Fax (+49) 0 94 21 / 55 22-99 eMail:[email protected] FCC registration number:90926 Industry Canada file number:IC 3050 EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: AZPFP-T3FR-72Test Report No. 55503-10420-1 Page 5 of 59 Pages 3.Summary of Test Results The tested sample complies with the requirements for set forth in the The Code of Federal Regulations 47, Part 95, Subpart C & E and The Code of Federal Regulations 47 Part 2, Subpart J. of the Federal Communication Commission (FCC). Johann RoidtThomas Eberl Technical ManagerTest Engineer EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: AZPFP-T3FR-72Test Report No. 55503-10420-1 Page 6 of 59 Pages 4.Operation Mode of EUT • transmitting continuously 1 • with battery supply nominal 12.0 V DC (8 x 1.5 AA cel) 2 • antenna extended to maximum 3 • operating with f = 72.550 MHz For conducted measurements a dummy load was used as delivered by applicant. A short description of the circuit and the method to stop modulation can be found in the following figure. 1 Modulation as indicated on appropriate test record 2 For conducted measurements replaced by external DC supply 3 For radiated emissions only EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: AZPFP-T3FR-72Test Report No. 55503-10420-1 Page 7 of 59 Pages 5.Configuration of EUT and Peripheral Devices EUT is configured as stand-alone device Configuration of cables of EUT Not applicable Configuration of peripheral devices connected to EUT Not applicable EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: AZPFP-T3FR-72Test Report No. 55503-10420-1 Page 8 of 59 Pages 6.Measuring Methods 6.1. Maximum Transmitter Power (ß95.639) The maximum transmitter power was measured conducted and radiated. 6.1.1.Conducted Maximum Transmitter Power A spectrum analyzer / EMI test receiver was connected to the output of the transmitter power amplifier (conducted measurement) via dummy load while EUT was operating in transmit mode using the assigned frequency. The trace mode of the spectrum analyzer was set to max hold with: RBW = 100 kHz, VBW = 100 kHz, span = 1 MHz, sweep = 20 ms (auto mode) See figure 1 for the measurement setup. Test equipment used (see equipment list for details): 02, 18, 51, 69, 70, 71 5 8 3 1 6 4 7 2 Figure 1: Measurement setup for testing on antenna connector 1 Transmitter (EUT) 5 Test cable 2 Dummy load 6 DC-block 3 Wooden table 7 Attenuator 4 DC power supply 8 Spectrum analyzer EMV-Pr ̧fzentrum EMI…
Text truncated - open the document above for the full version.
Radiated Power Test 30 MHz - 300 MHz according to FCC Part 95 Subpart C/E Model: T2(3)FR-AM Serial no.: -- Applicant: Futaba Corporation Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 07/18/2001 Operator: T. Eberl Test performed: automatically File name: Detector: Peak List of values: Selected by hand Mode: - TX mode f = 72.550 MHz - EUT in vertical position - antenna vertical 30 100300 MHz dBm 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 Limit1: FCC §95.639b3 Transducer: Substitution (H) Result: Limit kept Project file: 55503-10420 Page 36 of 59 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Power Test 30 MHz - 300 MHz according to FCC Part 95 Subpart C/E Model: T2(3)FR-AM Serial no.: -- Applicant: Futaba Corporation Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 07/18/2001 Operator: T. Eberl Test performed: automatically File name: Detector: Peak List of values: Selected by hand Mode: - TX mode f = 72.550 MHz - EUT in vertical position - antenna vertical Frequency MHz 72.55 145.10 217.65 Reading dBm -23.0 -78.5 -91.4 Correction factor dB 18.7 23.9 30.4 Value dBm -4.3 -54.6 -61.0 Limit dBm -27.3 -27.3 -27.3 Limit exceeded * Result: Limit kept Project file: 55503-10420 Page 37 of 59 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Power Test 30 MHz - 300 MHz according to FCC Part 95 Subpart C/E Model: T2(3)FR-AM Serial no.: -- Applicant: Futaba Corporation Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 07/18/2001 Operator: T. Eberl Test performed: automatically File name: Detector: Peak List of values: Selected by hand Mode: - TX mode f = 72.550 MHz - EUT in horizontal position - antenna horizontal 30 100300 MHz dBm 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 Limit1: FCC §95.639b3 Transducer: Substitution (H) Result: Limit kept Project file: 55503-10420 Page 38 of 59 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Power Test 30 MHz - 300 MHz according to FCC Part 95 Subpart C/E Model: T2(3)FR-AM Serial no.: -- Applicant: Futaba Corporation Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 07/18/2001 Operator: T. Eberl Test performed: automatically File name: Detector: Peak List of values: Selected by hand Mode: - TX mode f = 72.550 MHz - EUT in horizontal position - antenna horizontal Frequency MHz 72.55 145.10 217.65 290.20 Reading dBm -2.4 -58.5 -93.4 -92.0 Correction factor dB 18.7 23.9 30.4 34.0 Value dBm 16.3 -34.6 -63.0 -58.0 Limit dBm -27.3 -27.3 -27.3 -27.3 Limit exceeded * Result: Limit kept Project file: 55503-10420 Page 39 of 59 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Power Test 30 MHz - 300 MHz according to FCC Part 95 Subpart C/E Model: T2(3) FR Serial no.: -- Applicant: Futaba corporation Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 07/18/2001 Operator: T. Eberl Test performed: automatically File name: Detector: Peak List of values: Selected by hand Mode: - TX mode f = 72.550 Mhz - EUT in horizontal position- antenna horizontal ( right side on table ) 30 100300 MHz dBm 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 Limit1: FCC §95.639b3 Transducer: Substitution (H) Result: Limit kept Project file: 55503-10420 Page 40 of 59 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Power Test 30 MHz - 300 MHz according to FCC Part 95 Subpart C/E Model: T2(3) FR Serial no.: -- Applicant: Futaba corporation Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 meters Horizontal Polarization Date of test: 07/18/2001 Operator: T. Eberl Test performed: automatically File name: Detector: Peak List of values: Selected by hand Mode: - TX mode f = 72.550 Mhz - EUT in horizontal position- antenna horizontal ( right side on table ) Frequency MHz 72.55 145.10 217.65 290.20 Reading dBm -1.1 -57.9 -83.4 -93.0 Correction factor dB 18.7 23.9 30.4 34.0 Value dBm 17.6 -34.0 -53.0 -59.0 Limit dBm -27.3 -27.3 -27.3 -27.3 Limit exceeded * Result: Limit kept Project file: 55503-10420 Page 41 of 59 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Power Test 30 MHz - 300 MHz according to FCC Part 95 Subpart C/E Model: T2(3)FR-AM Serial no.: -- Applicant: Futaba Corporation Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 metres Vertical Polarization Date of test: 07/18/2001 Operator: T. Eberl Test performed: automatically File name: Detector: Peak List of values: Selected by hand Mode: - TX mode f = 72.550 MHz - EUT in vertical position - antenna vertical 30 100300 MHz dBm 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 Limit1: FCC §95.639b3 Transducer: Substitution (V) Result: Limit kept Project file: 55503-10420 Page 42 of 59 Pages Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220 Radiated Power Test 30 MHz - 300 MHz according to FCC Part 95 Subpart C/E Model: T2(3)FR-AM Serial no.: -- Applicant: Futaba Corporation Test site: Semi anechoic room, cabin no. 3 Tested on: Test distance 3 metres Vertical Polarization Date of test: 07/18/2001 Operator: T. Eberl Test performed: automatically File name: Detector: Peak List of values: Selected by hand Mode: - TX mode f = 72.550 MHz - EUT in vertical position - antenna vertical Frequency MHz 72.55 145.10 217.65 290.20 Reading dBm -6.4 -64.7 -88.7 -95.9 Correction factor dB 25.7 29.4 31.7 35.9 Value…
Text truncated - open the document above for the full version.
Aeussere Fruehlingstrasse 45 · Straubing · Germany
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 95C | 72.55 MHz - 72.55 MHz | 172.00 mW | 10K0F3D | 0.0005000000 % |

2.4GHz band Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Radio Control
Equipment Class
DTS - Digital Transmission SystemRadio Control
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterRadio Control
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Receiver
Equipment Class
DTS - Digital Transmission System