FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Futaba Corporation/
  3. AZPT2PG-75A

AZPT2PG-75ARadio Control Transmitter

Futaba Corporation
Radio Control Transmitter - FCC ID AZPT2PG-75A - Futaba Corporation
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
May 15, 2007
Application Purpose
Original Equipment
Date of Application
May 15, 2007
Equipment Note
Radio Control Transmitter
Frequency Range
75.41000000 - 75.99000000
Company
Futaba Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Futaba Corporation PHOENIX TEST-LAB GmbH Product Certification Königswinkel 10 D 32825 Blomberg AGENT AUTHORIZATION / FCC ID: AZPT2PG-75A To Whom It May Concern: Please be advised that Futaba Corporation authorizes Senton GmbH to act on our behalf, until otherwise notified, for applications submitted to PHOENIX TEST-LAB GmbH (PTL). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C.862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Date: 20 April 2007 ______________________________________ Signatory Nobumitsu Kanetsuna ______________________________________ Name printed

Cover Letter(s)

Ersteller: U. Rodemeier Revision: 03 Erstelldatum: 03.08.01 Datum: 4.10.2006 Seite 1 von 1 Request for Confidentiality PHOENIX TESTLAB GmbH Date: April 24, 2007 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: AZPT2PG-75A Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • Schematics • Block Diagram • Technical Description • Parts List The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : Senton GmbH address : Auessere Fruehlingstrasse 45, D-94315 Straubing Signature : Johann Roidt Job Title and Dept. : Technical Director

External Photos

FCC ID: AZPT2PG-75A FCC ID: AZPT2PG-75A FCC ID: AZPT2PG-75A FCC ID: AZPT2PG-75A

ID Label/Location Info

FCC ID: AZPT2PG-75A

Internal Photos

FCC ID: AZPT2PG-75A FCC ID: AZPT2PG-75A FCC ID: AZPT2PG-75A

Test Report

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 55503-061090 (Edition 2) Page 1 of 34 Pages (Einstellungen für den Prüfbericht) Straubing, 09 May 2007 T E S T - R E P O R T No. 55503-061090 (Edition 2) for T2PG 75 MHz Transmitter for model control Applicant: Futaba Corporation Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 95, Subpart C&E FCC Code of Federal Regulations, CFR 47, Part 2, Subpart J Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 2) Page 2 of 34 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ........................................................ 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory ........................................................................... 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT................................................................. 7 6 Measurement Procedures........................................................................................... 8 6.1 Maximum Transmitter Power................................................................................ 8 6.2 Frequency tolerance........................................................................................... 11 6.3 Emission Bandwidth ........................................................................................... 13 6.4 Unwanted Emission 30 MHz - 1 GHz ................................................................. 14 7 Photographs Taken During Testing .......................................................................... 16 8 Test Results .............................................................................................................. 20 8.1 Maximum transmitter power ............................................................................... 21 9 Carrier Frequency Stability........................................................................................ 23 9.2 Emission Bandwidth ........................................................................................... 26 9.3 Unwanted Radiation 30 MHz - 1 GHz................................................................. 28 10 Referenced Regulations ........................................................................................... 32 11 Additional Information supplementary to the Test Report......................................... 33 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 2) Page 3 of 34 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : T2PG 75 MHz Parts 2 : Serial number(s): Manufacturer: Futaba Corporation Type of equipment: Transmitter for model control Version: As delivered FCC ID: AZPT2PG-75A Additional parts/accessories: Technical data of EUT Application frequency range: 75.410 MHz - 75.990 MHz Frequency range: 75.410 MHz - 75.990 MHz Operating frequency: 75.710 MHz Type of modulation: AM Pulse train: Pulse width: Number of RF-channels: 60 Channel spacing: 10 kHz Designation of emissions 3 : 5K0A1D Type of antenna: Telescope antenna Size/length of antenna: 83 cm Connection of antenna: detachable not detachable Type of power supply: Battery supply Specifications for power supply: nominal voltage: 12.0 V minimum voltage: 10.2 V maximum voltage: 13.8 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 2) Page 4 of 34 Pages 2 Administrative Data Application details Applicant (full address): Futaba Corporation 1080, Yabutsuka Chosei-mura, Chosei-gun, Chiba-ken299-4395 Japan Contact person: Mr. Susumu Sakuma Contract identification: Receipt of EUT: 20. December 2007 Date(s) of test: January 2007 Note(s): Report details Report number: 55503-061090 Edition: 2 Issue date: 09 May 2007 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 2) Page 5 of 34 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory accreditation: DAR-Registration No. DAT-P-171/94-02 FCC test site registration number 90926 Industry Canada test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 2) Page 6 of 34 Pages 4 Summary Summary of test results The tested sample complies with the requirements set forth in the Code of Federal Regulations CFR 47, Part 95, Subpart C & E and the Code of Federal Regulations CFR 47 Part 2, Subpart J of the Federal Communication Commission (FCC). Personnel involved in this report Laboratory Manager: Mr. Johann Roidt Responsible for testing: Mr. Thomas Eberl Responsible for test report: Mr. Thomas Eberl Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 2) Page 7 of 34 Pages 5 Operation Mode and Configuration of EUT Operation Mode(s) - Transmitting continuously with 75.710 MHz, modulation as indicated in appropriate test record. - Antenna extended to maximum. 4 - It was not possible to deactivate modulation completely, thus the frequency-error-measurement was done with PPM-modulation. The appl…

Text truncated - open the document above for the full version.

Test Setup Photos

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 1) Page 17 of 33 Pages Test setup for radiated emission measurement (fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 1) Page 18 of 33 Pages Test setup for radiated emission measurement (fully anechoic room) - continued - Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503-061090 (Edition 1) Page 19 of 33 Pages Test setup for carrier frequency stability measurement

Contact Information

Applicant

Toshikazu Hama(Manager)
[email protected]+81-475-30-1061Fax: +81-475-32-6203

Technical Contact

Senton GmbHJohann Roidt
[email protected]49 9421 55 22 13

Aeussere Fruehlingstrasse 45 · Straubing · Germany

Non-Technical Contact

Senton GmbHJohann Roidt
[email protected]49 9421 55 22 13

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
195C75.41 MHz - 75.99 MHz224.00 mW8K00A1D0.0010000000 %
Confidentiality
Long Term
Grant Notes
Power is conducted.

Other Applications from Futaba Corporation

2.4GHz band Module - FCC ID AZP-FEX11T - Futaba Corporation
AZP-FEX11T

2.4GHz band Module

Jan 22, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Radio Control - FCC ID AZPCGY770R-24G - Futaba Corporation
AZPCGY770R-24G

Radio Control

Aug 19, 2024

Equipment Class

DTS - Digital Transmission System
AZPTM18

Radio Control

Jan 21, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
AZPR9001SB

Radio Control

Jan 17, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Receiver - FCC ID AZPR7201SB-24G - Futaba Corporation
AZPR7201SB-24G

Receiver

Jan 14, 2024

Equipment Class

DTS - Digital Transmission System