FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Futaba Corporation/
  3. AZPT3PN-75

AZPT3PN-75Radio Control Transmitter

Futaba Corporation
Radio Control Transmitter - FCC ID AZPT3PN-75 - Futaba Corporation
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Feb 19, 2006
Application Purpose
Original Equipment
Date of Application
Feb 19, 2006
Equipment Note
Radio Control Transmitter
Frequency Range
75.41000000 - 75.99000000
Company
Futaba Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thank you for purchasing a Futaba 3PN. Before using your 3PN, read this manual carefully and use your R/C set safely. After reading this manual, store it in a safe place. Application, Export, and Modification 1. This product may be used for models only. It is not intended for use in any application other than the control of models for hobby and recreational purposes. The product is subject to regulations of the Ministry of Radio/Telecommunications and is restricted under Japanese law to such purposes. 2. Exportation precautions: (a) When this product is exported from the country of manufacture, its use is to be approved by the laws governing the country of destination which govern devices that emit radio frequencies. If this product is then re-exported to other countries, it may be subject to restrictions on such export. Prior approval of the appropriate goverment authorities may be required. If you have purchased this product from an exporter outside your country, and not the authorized Futaba distributor in your country, please contact the seller immediately to determine if such export regulations have been met. (b) Use of this product with other than models may be restricted by Export and Trade Control Regula- tions, and an application for export approval must be submitted. In the US, use of 72MHz (aircraft only), 75MHz (ground models only) and 27MHz (both) frequency bands are strictly regulated by the FCC. This equipment must not be utilized to operate equipment other than radio controlled models. Similarly, other frequencies (except 50MHz, for HAM operators) must not be used to operate models. 3. Modification, adjustment, and replacement of parts: Futaba is not responsible for unauthorized modification, adjustment, and replacement of parts on this product. Any such changes may void the warranty. Compliance Information Statement (for U.S.A.) This device, trade name Futaba Corporation of America, model number R153F complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The responsible party of this device compliance is; Futaba Corporation of America 2865 Wall Triana Highway, Huntsville, Alabama 35824, U.S.A. TEL (256) 461 - 7348 Battery Recycling (for U.S.A.) The RBRC TM SEAL on the (easily removable) nickel-cadmium battery contained in Futaba products indicates that Futaba Corporation of America is voluntarily participating in an industry program to collect and recycle these batteries at the end of their useful lives, when taken out of service within the United States. The RBRC TM program provides a convenient alternative to placing used nickel-cadmium batteries into the trash or mu- nicipal waste system, which is illegal in some areas. You may contact your local recycling center for information on where to return the spent battery. Please call 1-800-8-BATTERY for information on Ni-Cd battery recycling in your area. Futaba Cor- poration of America's involvement in this program is part of its commitment to protecting our environ- ment and conserving natural resources. NOTE:Our instruction manuals encourage our customers to return spent batteries to a local recycling center in order to keep a healthy environment. RBRC TM is a trademark of the Rechargeable Battery Recycling Corporation. Warning: This product contains a chemical known to cause cancer and birth defects (or other reproductive harm). •No part of this manual may be reproduced in any form without prior permission. •The contents of this manual are subject to change without prior notice. •This manual has been carefully written. Please write to Futaba if you feel that any corrections or clarifications should be made. •Futaba is not responsible for the use of this product. 1 Before Operation ........................................................................ 6 System Contents ................................................................................................................... 6 Nomenclature / Handling ..................................................................................................... 7 Assembly / Adjustment .............................................................. 9 Receiver and Servo Connection .......................................................................................... 9 Assembly Precautions ...........................................................................................................9 Transmitter Set-Up Procedures ........................................................................................ 11 Safety Precautions ...................................................................... 2 Definition of Symbols ............................................................................................................ 2 Running Preparations Safety Precautions .......................................................................... 2 Running Safety Precautions ................................................................................................. 3 Storage and Disposal Safety Precautions ........................................................................... 4 Other Safety Precautions ..................................................................................................... 5 Description of 3PN Functions .................................................. 12 Steering Trim (TRM-CH1) ................................................................................................. 12 Throttle Trim (TRM-CH2) ................................................................................................. 12 Steering Dual Rates (D/R-CH1) ......................................................................................... 13 Model Selection/Model Reset (MDL) ....................................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

Federal Communications Commission 445 12 th Street SW Washington, DC 20554 USA Request for Confidentiality in accordance with CFR 0.457 and 0.459 11 January 2006 EMCCert DR. RAäEK - Certification Institute - Boelwiese 5 D-91320 Ebermannstadt RE: Certification Application FCC ID: AZPT3PN-75 Please be advised that the following information is to be held confidential on behalf of Futaba Corporation: • Schematics • Parts List • Block Diagram • Technical Description The application contains technical information which Futaba Corporation deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter.

External Photos

FCC ID: AZPT3PN-75 FCC ID: AZPT3PN-75 FCC ID: AZPT3PN-75 FCC ID: AZPT3PN-75 FCC ID: AZPT3PN-75 FCC ID: AZPT3PN-75

ID Label/Location Info

FCC ID: AZPT3PN-75

Internal Photos

FCC ID: AZPT3PN-75 FCC ID: AZPT3PN-75 FCC ID: AZPT3PN-75

Test Report

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 55503- 050777 (Edition 1) Page 1 of 34 Pages Straubing, 20 December 2005 T E S T - R E P O R T No. 55503- 050777 (Edition 1) for T3PN 75 MHz Transmitter for Model Control Applicant: Futaba Corporation Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 95, Subpart C&E FCC Code of Federal Regulations, CFR 47, Part 2, Subpart J Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 2 of 34 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ........................................................ 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory ........................................................................... 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT................................................................. 7 6 Measurement Procedures........................................................................................... 9 6.1 Maximum Transmitter Power................................................................................ 9 6.2 Frequency tolerance........................................................................................... 12 6.3 Emission Bandwidth ........................................................................................... 14 6.4 Unwanted Emission 30 MHz - 1 GHz ................................................................. 15 7 Photographs Taken During Testing .......................................................................... 17 8 Test Results .............................................................................................................. 21 8.1 Maximum transmitter power ............................................................................... 22 8.2 Carrier Frequency Stability ................................................................................. 24 8.3 Emission Bandwidth ........................................................................................... 27 8.4 Unwanted Radiation 30 MHz - 1 GHz................................................................. 29 9 Referenced Regulations ........................................................................................... 33 10 Charts taken during testing ....................................................................................... 34 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 3 of 34 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : T3PN 75 MHz Parts 2 : Serial number(s): 0001 Manufacturer: Futaba Corporation Type of equipment: Transmitter for Model Control Version: FCC ID: AZPT3PN-75 Additional parts/accessories: Technical data of EUT Application frequency range: 75.41 - 75.99 MHz Frequency range: 75.41 ñ 75.99 MHz Operating frequency: 75.71 MHz Type of modulation: FSK Pulse train: --- Pulse width: --- Number of RF-channels: 1 Channel spacing: 20 kHz Designation of emissions 3 : 5K0F1D Type of antenna: Telescope Antenna Size/length of antenna: 83 cm Connection of antenna: detachable not detachable Type of power supply: Battery supply Specifications for power supply: nominal voltage: 12.0 V minimum voltage: 10.2 V maximum voltage: 13.8 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 4 of 34 Pages 2 Administrative Data Application details Applicant (full address): Futaba Corporation 1080, Yabutsuka Chosei-mura Chosei-gun, Chiba-ken 299-4395 JAPAN Contact person: Mr. Michio Yamamoto Contract identification: --- Receipt of EUT: 13 December 2005 Date(s) of test: December 2005 Note(s): Report details Report number: 55503- 050777 Edition: 1 Issue date: 20 December 2005 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 5 of 34 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory accreditation: DAR-Registration No. DAT-P-171/94-02 FCC test site registration number 90926 Industry Canada test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 6 of 34 Pages 4 Summary Summary of test results The tested sample complies with the requirements set forth in the Code of Federal Regulations CFR 47, Part 95, Subpart C & E and the Code of Federal Regulations CFR 47 Part 2, Subpart J of the Federal Communication Commission (FCC). Personnel involved in this report Laboratory Manager: Mr. Johann Roidt Responsible for testing: Mr. Martin Steindl Responsible for test report: Mr. Martin Steindl Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 7 of 34 Pages 5 Operation Mode and Configuration of EUT Operation Mode(s) - Transmitting continuously, modulation as indicated on appropriate test report. Data signal for modulated signal:PPM - With battery supply, nominal 12.0 V. 4 - Antenna extended to maximum. 5 - Operating frequency: 75.710 MHz - For conducted measurements a dummy load was…

Text truncated - open the document above for the full version.

Test Setup Photos

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 18 of 34 Pages Test setup for radiated emission measurement (fully anechoic room) Figure 1: EUT in upright position Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 19 of 34 Pages Test setup for radiated emission measurement (fully anechoic room) - continued - Figure 2: EUT on rear side Figure 3: EUT on left side Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55503- 050777 (Edition 1) Page 20 of 34 Pages Test setup for carrier frequency stability measurement

Contact Information

Applicant

Toshikazu Hama(Manager)
[email protected]+81-475-30-1061Fax: +81-475-32-6203

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
195C75.41 MHz - 75.99 MHz224.00 mW5K0F1D4.9000000000 ppm
Confidentiality
Long Term
Grant Notes
Crystal Access panel must be permanently glued shut in manufacturing.

Other Applications from Futaba Corporation

2.4GHz band Module - FCC ID AZP-FEX11T - Futaba Corporation
AZP-FEX11T

2.4GHz band Module

Jan 22, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Radio Control - FCC ID AZPCGY770R-24G - Futaba Corporation
AZPCGY770R-24G

Radio Control

Aug 19, 2024

Equipment Class

DTS - Digital Transmission System
AZPTM18

Radio Control

Jan 21, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
AZPR9001SB

Radio Control

Jan 17, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Receiver - FCC ID AZPR7201SB-24G - Futaba Corporation
AZPR7201SB-24G

Receiver

Jan 14, 2024

Equipment Class

DTS - Digital Transmission System