Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Exhibit D T7YFK Instruntion Manual FCC ID AZPT7YFK-72
Exhibit D T7YFK Instruntion Manual FCC ID AZPT7YFK-72
Exhibit D T7YFK Instruntion Manual FCC ID AZPT7YFK-72
Exhibit D T7YFK Instruntion Manual FCC ID AZPT7YFK-72
Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility June 21, 1999 Subject: Correction of Equipment Classification To Whom It May Concern: This letter is to correct the equipment classification for the R/C transmitter Model No T7YFK. The transmitter was originally electronically filed on May 20, 1999 (FCC ID AZPT7YFK-72, Form 731 Confirmation Number EA94309). The equipment classification for the transmitter needs to be changed from its original classification to TNB (Non-Broadcast Transmitter). The following communications reference number 8328 was assigned to this matter. Thank you, Arnie Tapia EMC Sr. Technician Garwood Laboratories, Inc.
Garwood Laboratories, Inc. Garwood Laboratories, Inc.Garwood Laboratories, Inc. Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No. FR1111 EUT: T7YFK R/C Xmitter Date: May 19, 1999Page 1 of 30 EMC Measurement / Technical Report FCC Test Specification : FCC Part 95, Subpart C Radio Control (R/C) Radio Service Equipment Authorization : Certification Manufacturer : Futaba Corporation of America Equipment Under Test : T7YFK 72 โ 76 MHz Radio Control Transmitter Test Report No. : FR1111 Purchase Order No. : Verbal P.O. Document History RevisionIssue DateAffected Pages Description of ModificationsRevised By Approved By N/C19 May, 1999 Initial release Garwood Laboratories, Inc. Garwood Laboratories, Inc.Garwood Laboratories, Inc. Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No.FR1111EUT: T7YFK R/C Xmitter Date: May19, 1999Page 2 of 30 EMC Measurement / Technical Report Document No. FR1111 From Garwood Laboratories, Inc. World Compliance Division Test for Futaba Corporation of America T7YFK 72 โ 76 MHz Radio Control Transmitter Test PersonnelTest Dates Arnulfo Tapia- EMC Technician 7,11 May 1999 Test Facility Address City, State, Zip Code Phone Fax Garwood Laboratories, Inc.-OC 565 Porter Way Placentia, CA 92870 (714) 572-2027 (714) 572-2025 This report may be reproduced in full, partial reproduction may only be made with the written consent of the laboratory. The results in this report apply only to the equipment tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. government . Garwood Laboratories, Inc. Garwood Laboratories, Inc.Garwood Laboratories, Inc. Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No.FR1111EUT: T7YFK R/C Xmitter Date: May19, 1999Page 3 of 30 TABLE OF CONTENTS MEASUREMENT/TECHNICAL REPORT SUMMARY ............................................................... 4 1. GENERAL INFORMATION ........................................................................................................... 5 1.1 Product Description ...................................................................................................................... 5 1.2 Configuration of Tested System ................................................................................................... 5 1.3 Test Facility................................................................................................................................... 6 2. TECHNICAL INFORMATION ....................................................................................................... 7 2.1 Circuit Diagram ........................................................................................................................... 7 2.2 Function of Each Active Device .................................................................................................... 7 2.3 Tune-up Alignment Procedure ..................................................................................................... 7 2.4 Frequency Stabilization Circuitry ................................................................................................ 7 2.5 Additional Circuit Information .................................................................................................... 8 3. PRODUCT LABELING ................................................................................................................... 9 3.1 FCC ID Label................................................................................................................................ 9 3.2 Location of Label on EUT............................................................................................................. 9 3.3 Information to the User ................................................................................................................. 9 4. BLOCK DIAGRAMS OF EUT ....................................................................................................... 10 5. TEST RESULTS ............................................................................................................................. 11 5.1 RF Power Output ....................................................................................................................... 11 5.2 Occupied Bandwidth ................................................................................................................... 12 5.3 Field Strength of Spurious Radiation ......................................................................................... 13 5.4 Frequency Stabilty ...................................................................................................................... 15 6. PHOTOGRAPHS OF TEST ARRANGEMENTS & EUT CONSTRUCTION ........................... 18 APPENDIX A - TEST EQUIPMENT USED ................................................................................... 26 APPENDIX B -SUPPLEMENTAL TEST DATA ............................................................................. 27 ATTACHMENTS ................................................................................................................................. 30 Garwood Laboratories, Inc. Garwood Laboratories, Inc.Garwood Laboratories, Inc. Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No.FR1111EUT: T7YFK R/C Xmitter Date: May19, 1999Page 4 of 30 M EASUREMENT / T ECHNICAL R EPORT S UMMARY Manufacturer Comโฆ
Text truncated - open the document above for the full version.
Garwood Laboratories, Inc. Garwood Laboratories, Inc.Garwood Laboratories, Inc. Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No. FR1111 EUT: T7YFK R/C Xmitter Date: May 19, 1999Page 1 of 30 EMC Measurement / Technical Report FCC Test Specification : FCC Part 95, Subpart C Radio Control (R/C) Radio Service Equipment Authorization : Certification Manufacturer : Futaba Corporation of America Equipment Under Test : T7YFK 72 โ 76 MHz Radio Control Transmitter Test Report No. : FR1111 Purchase Order No. : Verbal P.O. Document History RevisionIssue DateAffected Pages Description of ModificationsRevised By Approved By N/C19 May, 1999 Initial release Garwood Laboratories, Inc. Garwood Laboratories, Inc.Garwood Laboratories, Inc. Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No.FR1111EUT: T7YFK R/C Xmitter Date: May19, 1999Page 2 of 30 EMC Measurement / Technical Report Document No. FR1111 From Garwood Laboratories, Inc. World Compliance Division Test for Futaba Corporation of America T7YFK 72 โ 76 MHz Radio Control Transmitter Test PersonnelTest Dates Arnulfo Tapia- EMC Technician 7,11 May 1999 Test Facility Address City, State, Zip Code Phone Fax Garwood Laboratories, Inc.-OC 565 Porter Way Placentia, CA 92870 (714) 572-2027 (714) 572-2025 This report may be reproduced in full, partial reproduction may only be made with the written consent of the laboratory. The results in this report apply only to the equipment tested. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. government . Garwood Laboratories, Inc. Garwood Laboratories, Inc.Garwood Laboratories, Inc. Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No.FR1111EUT: T7YFK R/C Xmitter Date: May19, 1999Page 3 of 30 TABLE OF CONTENTS MEASUREMENT/TECHNICAL REPORT SUMMARY ............................................................... 4 1. GENERAL INFORMATION ........................................................................................................... 5 1.1 Product Description ...................................................................................................................... 5 1.2 Configuration of Tested System ................................................................................................... 5 1.3 Test Facility................................................................................................................................... 6 2. TECHNICAL INFORMATION ....................................................................................................... 7 2.1 Circuit Diagram ........................................................................................................................... 7 2.2 Function of Each Active Device .................................................................................................... 7 2.3 Tune-up Alignment Procedure ..................................................................................................... 7 2.4 Frequency Stabilization Circuitry ................................................................................................ 7 2.5 Additional Circuit Information .................................................................................................... 8 3. PRODUCT LABELING ................................................................................................................... 9 3.1 FCC ID Label................................................................................................................................ 9 3.2 Location of Label on EUT............................................................................................................. 9 3.3 Information to the User ................................................................................................................. 9 4. BLOCK DIAGRAMS OF EUT ....................................................................................................... 10 5. TEST RESULTS ............................................................................................................................. 11 5.1 RF Power Output ....................................................................................................................... 11 5.2 Occupied Bandwidth ................................................................................................................... 12 5.3 Field Strength of Spurious Radiation ......................................................................................... 13 5.4 Frequency Stabilty ...................................................................................................................... 15 6. PHOTOGRAPHS OF TEST ARRANGEMENTS & EUT CONSTRUCTION ........................... 18 APPENDIX A - TEST EQUIPMENT USED ................................................................................... 26 APPENDIX B -SUPPLEMENTAL TEST DATA ............................................................................. 27 ATTACHMENTS ................................................................................................................................. 30 Garwood Laboratories, Inc. Garwood Laboratories, Inc.Garwood Laboratories, Inc. Garwood Laboratories, Inc. - World Compliance Division Electromagnetic Compatibility Document No.FR1111EUT: T7YFK R/C Xmitter Date: May19, 1999Page 4 of 30 M EASUREMENT / T ECHNICAL R EPORT S UMMARY Manufacturer Comโฆ
Text truncated - open the document above for the full version.
565 Porter Way ยท Placentia, California ยท United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 95 | 72 MHz - 76 MHz | 321.00 mW | 8K00F1D | 0.0020000000 % |

2.4GHz band Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Radio Control
Equipment Class
DTS - Digital Transmission SystemRadio Control
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterRadio Control
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Receiver
Equipment Class
DTS - Digital Transmission System