Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 Panic Button Installation Instructions Preliminary 4/7/00 Product Summary This panic button can be used throughout the premises for police, medical, or auxiliary alarm activation. When the sensor button is pressed, the built-in transmitter sends a sig- nal to the panel. The water-resistant design helps prevent damage in case the sensor accidently gets wet. The sensor can be worn using the belt clip or as a watch or as a pendant. Installation Considerations Use the following guidelines when installing this button. qThe transmitter in the button has an open-air range of up to 500 ft., but the installation environment may influence this range. qThe 3.0 VDC lithium battery will last at least 12 months. Programming the Sensor This section describes the steps for adding the sensor to panel memory. For complete instructions, refer to the spe- cific panel’s installation instructions. 1.Set the panel in the program mode. 2.When prompted by the panel, enter the appropriate group number (groups 00 through 07). 3.When prompted by the panel, select the desired sensor number. 4.When prompted by the panel, trip the sensor by press- ing the sensor button. 5.Exit from program mode. Testing the Sensor 1.Set the system to the Dealer Sensor Test mode. 2.Press the button on the sensor. 3.Count the number of signals received by the panel, indicated by interior siren beeps. Seven to eight beeps is considered acceptable. 4.Test the sensor from several locations within the pre- mises to check for consistent response. Replacing the Sensor Battery 1.Disassemble the sensor by removing the four screws on the back of the sensor and separate the front and back plastic. CAUTION You must be free of all static electricity before handling the transmitter circuit board. Touch a grounded, bare metal surface before touching the circuit board, or wear a grounding strap. 2.Remove the old battery from its holder and install the new battery, observing polarity. Note Install only the same size and type battery. Do not substitute another size or type battery. 3.Reassemble the sensor. CAUTION Be sure to assemble the sensor correctly to ensure water resistance. Be especially careful not to nick or damage the rubber gasket lining. 4.Test the sensor as described in the section “Testing the Sensor.” Lithium Battery Disposal Lithium batteries that are no longer usable are considered hazardous waste. Be sure to properly dispose of the old bat- tery. Contact your local city government for hazardous waste disposal laws. Specifications Compatibility: All ITI Learn Mode Panels Power Source: 3 Volt Duracell (DL2032) Enclosure: Water-Resistant and Shock-Resis- tant Dimensions: (L x W x D): 1.5” x 1.25” x .4” ITI Part No. 60-XXX Document Number: L66-1815 Rev. A PRELIMINARY April 2000 2 Panic Button Notices Preliminary 4/7/00 Notices US Patents 4,855,713, 4,864,636, and others pending. This device complies with FCC Rules Parts 15 and 68. Operation is subject to the following two conditions. 1.This device may not cause harmful interference. 2.This device must accept any interference that may be received, including interference that may cause undes- ired operation. FCC ID: B4Z-781A-PANIC Changes or modifications not expressly approved by Inter- active Technologies, Inc. can void the user’s authority to operate the equipment. 651-777-2690 651-779-4890 ITI is a registered trademark of Interactive Technologies, Inc.
Interactive Technologies Inc 04/07/00 9:52 AM FCC ID: B4Z-781A-PANIC E:\PROJECTS\Wrist_panic\FCC\BLOCK.DOC EXHIBIT C Block Diagram of Product 106.5MHz Osc RF Amp ITI Transmitter ASIC Manual Switch
Interactive Technologies Inc 04/12/00 2:32 PM FCC ID: B4Z-781A-PANIC E:\PROJECTS\Wrist_panic\FCC\extern.DOC EXHIBIT B External Photographs
Interactive Technologies Inc 04/12/00 2:36 PM FCC ID: B4Z-781A-PANIC E:\PROJECTS\Wrist_panic\FCC\id_label.DOC Note: FCC ID will be added to tooling as soon as approval granted. No units will be shipped without the ID. EXHIBIT A ID Label / Location
Interactive Technologies Inc 04/12/00 2:38 PM FCC ID: B4Z-781A-PANIC E:\PROJECTS\Wrist_panic\FCC\intern.DOC EXHIBIT H Internal Photographs
Interactive Technologies Inc 04/12/00 3:05 PM FCC ID: B4Z-781A-PANIC E:\PROJECTS\Wrist_panic\FCC\pcs\OP_DESC.DOC Product Description The product is a wireless wrist-band panic transmitter used in conjunction with a wireless security alarm system. When the panic button is depressed, the transmitter sends and alarm signal to the control panel. The control panel, depending on the configuration thereof, takes appropriate action. The panic transmitter can be factory programmed to send supervisory transmissions once per hour. The RF circuit consists of a 106.5 MHz oscillator followed by an amplifier. The amplifier is turned on and off to modulate the carrier. EXHIBIT I Operational Description
Interactive Technologies Inc 04/12/00 2:50 PM FCC ID: B4Z-781A-PANIC Page 1 of 22 E:\PROJECTS\Wrist_panic\FCC\FCC_REPT.DOC Interactive Technologies, Inc. ITI Wireless Wrist Panic Transmitter B4Z-781A-PANIC Certification Interactive Technologies Inc FCC_REPT.DOC 04/12/00 2:50 PM FCC ID: B4Z-781A-PANIC Page 2 of 22 ITI Wireless Wrist Panic Transmitter B4Z-781A-PANIC 4/12/2000 Interactive Technologies, Inc. 2266 North Second Street North Saint Paul, MN 55109 (651) 777-2690 Interactive Technologies Inc FCC_REPT.DOC 04/12/00 2:50 PM FCC ID: B4Z-781A-PANIC Page 3 of 22 1. INTRODUCTION4 2. STATEMENT OF COMPLIANCE4 3. LAB MEASUREMENTS DISCUSSION / TEST NOTES7 3.1 Test Notes 7 3.1.1 Transmissions shall cease within 5 seconds of activation [ §15.231(a)(2) ]7 3.1.2 Supervisory Calculation [ §15.231(a)(3) ]9 3.1.3 Duty Cycle Correction Factor [§15.231(b)(2) and §15.35(c)]9 3.1.4 Bandwidth Measurement [ §15.231(c) ]12 3.1.5 Emissions Measurements16 3.1.5.1 Radiated Emissions Summary16 3.1.5.2 FCC Emissions Calculation16 3.1.5.2.1 Terms16 3.1.5.2.2 Example Calculation16 3.1.5.3 Radiated Emissions17 3.1.5.4 Forbidden Bands17 Interactive Technologies Inc FCC_REPT.DOC 04/12/00 2:50 PM FCC ID: B4Z-781A-PANIC Page 4 of 22 1. Introduction This device is a wireless wrist panic transmitter for use in a wireless security system. The unit is self-contained and powered by a 3.0 Volt Lithium Coin Cell battery. The transmitter’s frequency is crystal controlled and is not adjustable by the user. The device (without wrist band) measures approximately 1.5 ′′ in length, 1.25 ′′ in width, and 0.375 ′′ in height. The unit weighs approximately0.7 ounces with battery. We are requesting Certification under FCC Rules, Part 15, Subpart C, Paragraph 15.231. Please send comments/suggestions on the report format to [email protected]. 2. Statement of Compliance §2.907Certification This is an application for certification §2.911Application a)This is an application and has been filed electronically with form 731. b)All information required has been supplied. c)The applicant has signed the application (electronically). d)The technical data has been signed. (See Radiated Emissions) e)Applicant signature block on electronic form 731 completed by officer of the company or authorized company personnel. f) The appropriate fee has been paid electronically with VISA on 4/12/00. §2.915Grant This application demonstrates that all applicable technical standards have been met and a grant of this application will serve the public interest. §2.925Label Each piece of equipment for which authorization will be granted will be uniquely identified with “FCC ID: B4Z-781A-PANIC.” The required statement will appear with the FCC ID on the product and, although not required, in the installation instructions. See Exhibit A, PDF file id_label.pdf Interactive Technologies Inc FCC_REPT.DOC 04/12/00 2:50 PM FCC ID: B4Z-781A-PANIC Page 5 of 22 §2.947Measurement Procedure a)The measurement procedure follows ANSI C63.4 procedure. Procedural notes are contained in the laboratory report. d)A list of test equipment used is contained in the laboratory report. §2.948Description of Measurement Facilities Measurements were performed at TUV Testing Services Open Test Site. The FCC keeps a full description of the measurement facilities on file. TUV’s acceptance and approval is dated as December 5, 1993 in a letter received from the FCC. The address of the test facility is: TUV Product Service 19035 Wild Mountain Road Taylors Falls, MN 55084-1758 Phone: 651-638-0297 Contact:Joel Schneider Test Engineer in Charge See Exhibit F, PDF file test_pho.pdf for sketch of measurement setup §2.1033Application for Certification a)Form 731 has been electronically filed on 4/12/00. Items that did not apply were left blank. b)This technical report contains the following information where applicable. 1)Full name and mailing address of manufacturer and applicant for certification: Interactive Technologies Inc 2266 North Second Street North Saint Paul, MN 55109 2)FCC Identifier: B4Z-781A-PANIC 3)Copy of installation instructions: See Exhibit G, PDF file: user_man.pdf 4)Brief Description of circuit functions and device operation: See Exhibit I, PDF file op_desc.pdf See Exhibit D, PDF file schemat.pdf for schematics (page 1) and parts placement (page 2) diagrams. 5) Block Diagram Interactive Technologies Inc FCC_REPT.DOC 04/12/00 2:50 PM FCC ID: B4Z-781A-PANIC Page 6 of 22 See Exhibit C, PDF file block.pdf . 6)Report of the measurements of radiation and conducted emissions: This document. 7)Photographs External: See Exhibit B, PDF file extern.pdf Internal: See Exhibit H, PDF file intern.pdf 8)Peripheral or Accessory devices: This is not applicable since this device is stand-a- lone product. 9) Transition Rules This application is not pursuant to the transition rules of §15.37 10)Emergency Broadcast decoding: This is not applicable to device in this application. 11)Application for direct sequence spread spectrum devices... This is not applicable to device in this application. 12)Application for scanning receivers... This is not applicable to device in this application. c)Composite Systems This is not applicable to device in this application. Interactive Technologies Inc FCC_REPT.DOC 04/12/00 2:50 PM FCC ID: B4Z-781A-PANIC Page 7 of 22 3. Lab Measurements Discussion / Test Notes 3.1 Test Notes 3.1.1 Transmissions shall cease within 5 seconds of activation [ §15.231(a)(2) ] In the event of a panic alarm, 8 packets are sent in the transmission. The packet duration is, at most, 30 mS, see Duty Cycle Correction Factor [§15.231(b)(2) and §15.35(c)] . The time between packets random between 100 mS and 450 mS so the length of the longest transmission is: 8*30mS + 7*450mS = 3.39 seconds. The following plot shows an 8-packet transmission that concludes in less than 5 seconds. Interactive Technologies Inc FCC_REPT.DOC 04/12/00 2:50 PM FCC ID: B4Z-781A-PANIC Page 9 of 22 3.1.2 Supervisory Calculat…
Text truncated - open the document above for the full version.
2266 North 2nd Street · North Saint Paul, Minnesota · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 319.5 MHz - 319.5 MHz | - |

AV-3G
Equipment Class
PCB - PCS Licensed Transmitter
AVO-BT
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
AVO-ZW
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
AVO-BTWIFI
Equipment Class
DTS - Digital Transmission System
PIR Security System Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter