B4Z-787E-SIMONcontrol panel

UTC Fire & Security Americas Corporation, Inc.
control panel - FCC ID B4Z-787E-SIMON - UTC Fire & Security Americas Corporation, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 20, 2002
Application Purpose
Original Equipment
Date of Application
May 07, 2002
Equipment Note
control panel
Frequency Range
319.50000000 - 319.50000000
Company
UTC Fire & Security Americas Corporation, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Contents Tv€‚"Trpˆ…v‡’ T’†‡r€8‚‡…‚y Qhry Installation Instructions Document Number: 466-1873 Rev. C PRELIMINARY May 2002 Test Weekly C O D E Status System 9 / 0 Windows Doors & Sensors Motion Disarm 5 / 6 Arm 3 / 47 / 8 On Off AUX SensorMotionTime FIRE POLICE Lights Special H O M E C O N T R O L E M E R G E N C Y H O M E S E C U R I T Y Doors Chime 1 / 2 ITI Part Nos. 60-875 60-910 About This Manual 1 Special Installation Requirements 1 UL Listed Installations 1 Central Station Reporting 1 UL Canada Listed Installations 1 California State Fire Marshall Listed Installations 2 Planning the Installation 2 Standard Panel 2 Interrogator 200 Audio Verification Module 2 Installing the System 2 System Components 2 Control Panel 2 System Devices 3 Planning Sensor Types & Locations 3 Device Locations 4 Control Panel 4 Remote Handheld Touchpad 4 Keychain Touchpad 4 X-10 Modules 4 House Code and Unit Numbers 4 Installing the System 5 Materials Needed 5 Opening the Panel Cover and Chassis 5 Mounting the Panel 5 Connecting Hardwire Devices 6 AC Terminals 6 HWIN1, HWIN2, and DCOUT Terminals 6 Wiring Interior Sirens 6 LD105 Hardwire Interior Siren 6 Wiring Exterior Sirens 7 Hardwire Exterior Siren with Supervision 7 Hardwire Exterior Siren without Supervision 7 Wiring Hardwire Contacts 7 Wiring a Phone Line to the Panel 7 Full Line Seizure 7 No Line Seizure 8 Wiring the Power Transformer 9 Powering Up the Panel 9 Installing the Panel Backup Battery 9 Applying AC Power 9 Installing X-10 Modules 9 Lamp and Appliance Modules 9 Universal Module 10 Sensor Installation 10 Programming 10 Entering Program Mode 10 Closing the Cover 10 Reset Memory to the Factory Defaults 10 Set the Clock 10 Adding (Learning) Sensors 10 Deleting Sensors 12 X-10 Module Operation 12 Numbered Options 12 Option 01: Panel Piezo Beeps 13 Option 02: Panel Voice 13 Option 03: Latchkey 13 Option 04: Primary Phone Number 13 Option 05: Secondary Phone Number 13 Option 06: Downloader Phone Number 14 Option 07: Account Number 14 Option 08: Phone Lock 14 Option 09: Downloader Code 14 Option 10: Entry Delay 14 Option 11: Exit Delay 14 Option 12: Phone Mod 1 15 Option 13: Phone Mod 2 15 Option 14: DTMF Dialing 15 Option 15: No Activity Time-out 15 Option 16: Auto Phone Test 16 Option 17: Dialer Delay 16 Option 18: Alarm Cancel Report 16 Option 19: RF Timeout 16 Option 20: Manual Phone Test 16 Option 21: Opening Reports 17 Option 22: Closing Reports 17 Option 23: Force Armed Report 17 Option 24: AC Power Failure Report 17 Option 25: CPU Low Battery Report 17 Option 26: Fail to Communicate 17 Option 27: Ring/Hang/Ring 17 Option 28: No Delay from Keychain Touchpad 18 Option 29: Panel Piezo Alarms 18 Option 30: Panel Panic Alarms 18 Option 31: Downloader Enable 18 Option 32: 300 Baud 18 Option 33: Audio Verification 18 Option 34: Fail to Open Report 18 Option 35: Fail to Close Report 19 i Option 36: Sensor Activated Light Lockout Start Time 19 Option 37: Sensor Activated Light Lockout Stop Time 19 Option 38: Auto Arm 19 Option 39: Siren Timeout 19 Option 40: Trouble Beeps 20 Option 41: Chime Voice 20 Option 42: Speaker Level 20 Option 43: Numeric Pager/Voice Event Notification Phone Number 20 Option 44: Numeric Pager/Voice Event Notification Phone Mod 3 20 Option 45: Sensor Alarm Restoral Report 21 Option 46: Fire Shutdown - AVM 21 Option 47: AVM Mode 21 Option 48: Panic Talk - AVM 21 Option 49: Arming LEDs Shutdown 21 Option 50: RF Jam Detect 21 Option 51: 24 Hour Tamper 21 Option 52: Unvacated Premises 22 Option 53: Hardwire Siren Supervision 22 Option 54: Access Code Length 22 Option 55: Status Beep Volume 22 Option 56: Call Waiting 22 Option 57: Supervisory/Tamper Report 23 Option 58: Remote Touchpad Arming 23 Option 59: Exit Extension 23 Option 60: Secure Arming 23 Option 61: Demo Mode 23 Option 62: Supervisory Protest 23 Option 63: 24 Hour Time 23 Option 64: No Arm on Panel Low Battery 24 Option 65: No Usage Report 24 Option 66: External Siren Delay 24 Option 67: Quick Exit 24 Option 68: Swinger Shutdown 24 Option 69: SIA Limits 24 Option 70: Not Available Option 71: Programming Report 25 Option 72: Supervisory Time 25 Option 73: Modem Sensitivity 25 Option 74: Silent Panel Police Panic 25 Option 75: VOX Mic Gain 25 Option 76: VOX Gain Range 25 Option 77: Manual Mic Gain 25 Option 78: VOX Receiver Gain 26 Option 79: Panel Cover Tamper 26 Option 80: Alarm Report Verification 26 Programming System Access Codes 26 Testing the System 26 Control Panel 26 Sensors 27 Improving Sensor/Panel Communication 28 Antenna 28 If a Sensor Fails the Sensor Test 28 Phone Communication 28 Off-Site Phone Operation 29 Central Station Communication 29 Pager Communication 29 2-Way Voice Operation 29 Voice Event Notification 30 X-10 Operation 30 Manual Lamp Module Control 30 X-10 Siren and Lamp Module Functions 30 Emergency Planning 31 Appendix A: Troubleshooting 32 System Status 32 Control Panel 32 Options (Programmable by the homeowner) 32 Sensors 32 X-10 Modules 32 Appendix B: System Configuration 33 Alphabetical Listing of Sensor Names 33 Sensor Assignments/Locations 33 Sensor Group Characteristics 34 Home Control Planning 35 System Access Codes 35 Option Settings 36 Specifications 39 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by Interlogix Inc. can void the user’s authority to operate the equipment. FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio o…

Text truncated - open the document above for the full version.

Block Diagram

Interactive Technologies Inc 05/08/02 1:27 PM FCC ID: B4Z-787E-SIMON C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Simon III\peices\BLOCK.DOC EXHIBIT C Block Diagram of Product

External Photos

Interactive Technologies Inc 05/08/02 2:31 PM FCC ID: B4Z-787E-SIMON C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Simon III\peices\extern.DOC EXHIBIT B External Photographs

ID Label/Location Info

Interactive Technologies Inc 05/08/02 2:33 PM FCC ID: B4Z-787E-SIMON C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Simon III\peices\id_label.DOC EXHIBIT A ID Label / Location

ID Label/Location Info

Interactive Technologies Inc 05/23/02 2:12 PM FCC ID: B4Z-787E-SIMON W:\iti2vol2\PRJ\DEG\ACTIVE\60-875-95R Simon 3 Domestic\Approvals-Listings-Technical File\FCC\Part 15 Submittle\peices\id_label.DOC EXHIBIT A ID Label / Location

Internal Photos

Interactive Technologies Inc 05/08/02 1:28 PM FCC ID: B4Z-787E-SIMON C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Simon III\peices\intern.DOC EXHIBIT H Internal Photographs

Operational Description

Interactive Technologies Inc 05/08/02 1:28 PM FCC ID: B4Z-787E-SIMON C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Simon III\peices\OP_DESC.doc Product Description SIMON III is a self-contained security system that includes a keypad, hardwire zone input, siren, receiver and transmitter. The keypad is for user control and feedback. The hardwire zone input works in conjunction with common magnetic contacts. The RF receiver is used to monitor any of several sensor/transmitter products. These sensors may indicate the states of doors, windows, or whether or not a smoke detector is tripped. The siren is a piezo type that can give status beeps or sound full volume tones in the event of an alarm. The microcontroller used is Mitsubishi M30620FCAFP. The RF transmitter is a 106.5 MHz oscillator. The third harmonic is filtered off and fed into an amplifier. The amplifier is turned on and off to modulate the carrier. The transmission frequency is 319.5MHz. The receiver receives 319.5MHz. EXHIBIT I Operational Description

Test Report

Interactive Technologies Inc 05/08/02 1:24 PM FCC ID: B4Z-787E-SIMON Page 1 of 24 C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Simon III\peices\FCC_REPT.DOC Interactive Technologies, Inc. SIMON III Security Control Panel B4Z-787E-SIMON Certification Interactive Technologies Inc FCC_REPT.DOC 05/08/02 1:24 PM FCC ID: B4Z-787E-SIMON Page 2 of 24 ALLEGRO Security Control Panel B4Z-785B-ALGRO 5/8/2002 Interactive Technologies, Inc. 2266 North Second Street North Saint Paul, MN 55109 (651) 777-2690 Interactive Technologies Inc FCC_REPT.DOC 05/08/02 1:24 PM FCC ID: B4Z-787E-SIMON Page 3 of 24 1. INTRODUCTION4 2. STATEMENT OF COMPLIANCE4 3. LAB MEASUREMENTS DISCUSSION / TEST NOTES7 3.1 Test Notes7 3.1.1 Transmissions shall cease within 5 seconds of activation [ §15.231(a)(2) ]7 3.1.2 Supervisory Calculation [ §15.231(a)(3) ]9 3.1.3 Duty Cycle Correction Factor [§15.231(b)(2) and §15.35(c)]9 3.1.4 Bandwidth Measurement [ §15.231(c) ]12 3.1.5 Emissions Measurements16 3.1.5.1 Radiated Emissions Summary16 3.1.5.2 FCC Emissions Calculation16 3.1.5.2.1 Terms16 3.1.5.2.2 Example Calculation17 3.1.5.3 Radiated Emissions18 3.1.5.4 Forbidden Bands18 Interactive Technologies Inc FCC_REPT.DOC 05/08/02 1:24 PM FCC ID: B4Z-787E-SIMON Page 4 of 24 1. Introduction This device is a wireless Control Panel with a transmitter for use in a wireless security system. The unit is self-contained and powered by a 9VAC Class 2 transformer, and a 6VDC battery, used as a back up power supply. The transmitter’s frequency is crystal controlled and is not adjustable by the user. The device measures approximately 6.5” in width, 1.75” in depth and 7.5′′ in height. The unit weighs approximately 1 pound, 2 ounces without the battery. We are requesting Certification under FCC Rules, Part 15, Subpart C, Paragraph 15.231. Please send comments/suggestions on the report format to: [email protected]. 2. Statement of Compliance §2.907Certification This is an application for certification §2.911Application a)This is an application and has been filed electronically with form 731. b)All information required has been supplied. c)The applicant has signed the application (electronically). d)The technical data has been signed. (See Radiated Emissions) e)Applicant signature block on electronic form 731 completed by officer of the company or authorized company personnel. f) The appropriate fee has been paid electronically with VISA on 5/8/02. §2.915Grant This application demonstrates that all applicable technical standards have been met and a grant of this application will serve the public interest. §2.925Label Each piece of equipment for which authorization will be granted will be uniquely identified with “FCC ID: B4Z-787E-SIMON.” The required statement will appear with the FCC ID on the product and, although not required, in the installation instructions. See Exhibit A, PDF file id_label.pdf Interactive Technologies Inc FCC_REPT.DOC 05/08/02 1:24 PM FCC ID: B4Z-787E-SIMON Page 5 of 24 §2.947Measurement Procedure a)The measurement procedure follows ANSI C63.4 procedure. Procedural notes are contained in the laboratory report. d)A list of test equipment used is contained in the laboratory report. §2.948Description of Measurement Facilities Measurements were performed at TUV Testing Services Open Test Site. The FCC keeps a full description of the measurement facilities on file. TUV’s acceptance and approval is dated as December 5, 1993 in a letter received from the FCC. The address of the test facility is: TUV Product Service 19035 Wild Mountain Road Taylors Falls, MN 55084-1758 Phone: 651-638-0297 Contact:Joel Schneider Test Engineer in Charge See Exhibit F, PDF file test_pho.pdf for sketch of measurement setup §2.1033Application for Certification a)Form 731 has been electronically filed on 5/8/02. Items that did not apply were left blank. b)This technical report contains the following information where applicable. 1)Full name and mailing address of manufacturer and applicant for certification: Interactive Technologies Inc 2266 North Second Street North Saint Paul, MN 55109 2)FCC Identifier: B4Z-787E-SIMON 3)Copy of installation instructions: See Exhibit G, PDF file: user_man.pdf 4)Brief Description of circuit functions and device operation: See Exhibit I, PDF file op_desc.pdf Interactive Technologies Inc FCC_REPT.DOC 05/08/02 1:24 PM FCC ID: B4Z-787E-SIMON Page 6 of 24 See Exhibit D, PDF file schemat.pdf for schematics (page 1) and parts placement (page 2) diagrams. 5) Block Diagram See Exhibit C, PDF file block.pdf. 6)Report of the measurements of radiation and conducted emissions: This document. 7)Photographs External: See Exhibit B, PDF file extern.pdf Internal: See Exhibit H, PDF file intern.pdf 8)Peripheral or Accessory devices: This is not applicable since this device is stand-a- lone product. 9) Transition Rules This application is not pursuant to the transition rules of §15.37 10)Emergency Broadcast decoding: This is not applicable to device in this application. 11)Application for direct sequence spread spectrum devices... This is not applicable to device in this application. 12)Application for scanning receivers... This is not applicable to device in this application. c)Composite Systems This is not applicable to device in this application. Interactive Technologies Inc FCC_REPT.DOC 05/08/02 1:24 PM FCC ID: B4Z-787E-SIMON Page 7 of 24 3. Lab Measurements Discussion / Test Notes 3.1 Test Notes 3.1.1 Transmissions shall cease within 5 seconds of activation [ §15.231(a)(2) ] In the event of an alarm, 6 packet is sent. The packet duration is, at most, 30 mS, see Duty Cycle Correction Factor [§15.231(b)(2) and §15.35(c)]. The time between packets random between 100 mS and 450 mS so the length of the longest transmission is: 6*30mS + 5*450mS = 2.43 seconds. The following plot shows a 6 packet transmission that concludes in less than 5 seconds. Interactive Technologies Inc FCC_REPT.DOC 05/08/02 1:24 PM FCC ID: …

Text truncated - open the document above for the full version.

Test Setup Photos

Interactive Technologies Inc 05/08/02 1:29 PM FCC ID: B4Z-787E-SIMON C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Simon III\peices\TEST_PHO.DOC 0.8 Meters EUT Receiving Antenna 3 Meters EXHIBIT F Test Setup Sketch for Radiated Emissions 1 Meter

Contact Information

Applicant

Konstantin Khrustov(Compliance Leader)
[email protected]949-737-7815Fax: 949-737-7882

Technical Contact

GE InterlogixKen L Nelson
[email protected]651-779-4825

2266 North Second Street · North St. Paul, Minnesota · United States

Test Firm

TUV SUD America - Product ServiceJoel Schneider
[email protected]651-604-4582Fax: 651-638-0298

Technical Specifications

#Rule PartsFrequency RangePower Output
115C319.5 MHz - 319.5 MHz-

Other Applications from UTC Fire & Security Americas Corporation, Inc.

AV-3G - FCC ID B4Z-944-3G - UTC Fire & Security Americas Corporation, Inc.
B4Z-944-3G

AV-3G

May 04, 2015

Equipment Class

PCB - PCS Licensed Transmitter
AVO-BT - FCC ID B4Z-962-BT - UTC Fire & Security Americas Corporation, Inc.
B4Z-962-BT

AVO-BT

May 04, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
AVO-ZW - FCC ID B4Z-959-ZW - UTC Fire & Security Americas Corporation, Inc.
B4Z-959-ZW

AVO-ZW

Apr 29, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
AVO-BTWIFI - FCC ID B4Z-958-BTWI - UTC Fire & Security Americas Corporation, Inc.
B4Z-958-BTWI

AVO-BTWIFI

Apr 29, 2015

Equipment Class

DTS - Digital Transmission System
PIR Security System Transmitter - FCC ID B4Z-680F-PIR - UTC Fire & Security Americas Corporation, Inc.
B4Z-680F-PIR

PIR Security System Transmitter

Dec 01, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter