B4Z-802A-SHOCKShock Sensor

UTC Fire & Security Americas Corporation, Inc.
Shock Sensor - FCC ID B4Z-802A-SHOCK - UTC Fire & Security Americas Corporation, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 10, 2002
Application Purpose
Original Equipment
Date of Application
Dec 12, 2001
Equipment Note
Shock Sensor
Frequency Range
319.50000000 - 319.50000000
Company
UTC Fire & Security Americas Corporation, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

Internal Photos

Operational Description

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

8394g09b.dsf 1 Grh…H‚qrTu‚px Tr†‚… ITI Part No. 60-886-95 60-886-11-95 Installation Instructions Product Summary The Learn Mode Shock Sensor has the following three main functions: ❑To detect the vibrations made by an intruder trying to break a window or door. ❑To detect a window or door opening. ❑To detect tamper situations, such as an intruder remov- ing the sensor cover. Vibrations cause a momentary open circuit in the shock ele- ment of the sensor. The circuit closes again when the vibra- tion stops. The sensor microcontroller “sees” the open/close action as a pulse, causing the sensor to transmit an alarm signal. The sensor has two different detection modes: ❑Gross Attack - detect a violent blow sufficient in length to trip sensor. ❑Pulse Count - detect a sufficient number of less violent blows (rapping or tapping). The sensor includes an internal magnetic reed switch that must be disabled if it is not used. A cover tamper provides additional security if an intruder tries to disable or damage the sensor. Figure 1. Shock Sensor Main Components Installation Guidelines ❑Learn the sensor before adjusting the shock sensitivity. The sensor is shipped with the reed switch enabled and open, and this is how it must be learned. ❑Before permanently mounting the sensor, test it at the intended location to make sure that the panel can receive sensor signal transmissions. The sensor is an RF device and there may be blind or non-operational locations within the installation. Normally, these can be overcome by moving the sensor or receiver. ❑Always mount the shock sensor so that the detector is on the frame and not on glass, solid, or hollow-core doors. See Figure 2 for mounting locations. Figure 2. Mounting Options for Door/Window Styles ❑Mount the sensor in a location where the structure can transmit vibrations to the sensor. ❑The sensor can be mounted on a vertical surface or on a horizontal (flat) surface. ❑Make sure the window fits snugly in the frame and doesn’t move or rattle. ❑Hold the sensor against the frame to make sure the sen- sor base fits on the surface area of the frame and doesn’t extend over the surface edges. Shock Sensor Orientation There are two types of shock sensor mounting orientations; on a vertical surface or on a horizontal surface (sill or ledge). On a vertical surface, there are two orientations (see Figure 3). Note On a vertical surface, the shock sensor element must always be oriented with its screw terminals down , or the writing on the shock element horizontal. 1 2 3 4 5 6 ON Reed Switch Cover Tamper Switch Battery Holder Shock Element DIP Switches LOGO 8394g10b.dsf 9HU WLFDO 6XUIDFH0RXQWLQJ +RUL]RQWDO )O DW 6 XUIDFH0RXQWLQJ Shock Sensor Shock SensorShock Sensor Shock Sensor Document Number: 466-1925 Rev. A December 2001 2 Installation Figure 3. Positioning shock element according to mounting orientation on a vertical surface On a horizontal surface (sill or ledge), any orientation is allowed, but certain sensor element orientations are better than others. The element is much better at detecting hori- zontal vibrations perpendicular to its writing than parallel (see Figure 4). Figure 4. Positioning shock elements for horizontal surface mounting Tools and Supplies ❑Control panel installation instructions ❑Phillips screwdriver ❑Slotted screwdriver (to pry off the cover) ❑Two #6 x 3/4” flathead screws for mounting the sensor (included) ❑Two #6 x 5/8” screws for mounting the magnet (included) Installation Caution! You must be free of all static electricity when handling electronic components. Touch a grounded, bare metal surface before touching a circuit board or wear a grounded wrist strap. 1. Insert a slotted screwdriver into the slot at the top end of the unit and remove the cover (see Figure 5). Figure 5. Remove the sensor cover 2. Using the flathead mounting screws, secure the base to the mounting surface either vertically or horizontally as required (see Figure 6). Figure 6. Sensor base mounting holes 3. Position the shock element and press it firmly into its socket (see Figure 7). 4. If using the reed switch, use the two remaining screws to mount the magnet so that its arrow is aligned with the arrow on the sensor case (see Figure 7). Figure 7. Magnet alignment Important! You must disable the reed switch if you are not using it. If the reed switch is enabled but no magnet is installed, the sensor will be in a continuous alarm state. 1 2 3 4 5 6 ON 1 2 3 4 5 6 O N Shock Element Shock Element Screw Terminals Screw Terminals LOGO LOGO 1 2 3 4 5 6 O N 1 2 3 4 5 6 O N Shock Element Shock Element Screw Terminals Screw Terminals Parallel Perpendicular (Bad) (Good) LOGO LOGO Direction of Vibration 8394g02b.dsf Top End Slot 1 2 3 4 5 6 ON Shock Element Mounting Hole Mounting Hole (Located Under Shock Element) LOGO Magnet Arrows 3 Reed Switch Setting Adjusting the Shock Sensor DIP Switches The following describes the DIP switch functions: ❑DIP Switches 1 and 2—adjust the Pulse Count. ❑DIP Switches 3 and 4—adjust the sensitivity setting of Gross Attack detection. ❑DIP Switch 5—enable/disable reed switch. ❑DIP Switch 6—not used. Note In order for the LED to indicate shock detection while adjusting the sensitivity, be sure the reed switch is dis- abled (DIP switch 5 OFF) or that the magnet is lined up with the reed switch if DIP switch 5 is ON. Gross Attack Adjustment 1. To adjust the sensor for Gross Attack, set DIP switches 1 and 2 to the ON position. This disables the Pulse Count so that the unit can only be activated by a Gross Attack. 2. Apply high level shocks to the mounting structure, using the LED as a guide to when the alarm trips (LED on for 4 seconds). The LED will blink for 1 second every time the sensor detects a pulse. A shock that is severe enough to cause an alarm will cause the LED to light for approximately 4 seconds. 3. Use switches 3 and 4 to adjust the Gross Attack sensitiv- ity of the sensor (see Table 1). 4. Repeat step 2 each time you make a…

Text truncated - open the document above for the full version.

Block Diagram

Interactive Technologies Inc 12/13/01 6:16 AM FCC ID: B4Z-802A-SHOCK C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Us Shock\peices\BLOCK.DOC EXHIBIT C Block Diagram of Product Shock Circuitry 106.5MHz Osc RF Amp Micro Controller Shock SensorITI Transmitter

External Photos

Interactive Technologies Inc 12/13/01 1:53 PM FCC ID: B4Z-802A-SHOCK C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Us Shock\peices\extern.DOC EXHIBIT B External Photographs

Test Report

Interactive Technologies Inc 12/13/01 10:50 AM FCC ID: B4Z-802A-SHOCK Page 1 of 23 C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Us Shock\peices\FCC_REPT.DOC Interactive Technologies, Inc. Shock Sensor B4Z-802A-SHOCK Certification Interactive Technologies Inc FCC_REPT.DOC 12/13/01 10:50 AM FCC ID: B4Z-802A-SHOCK Page 2 of 23 Shock Sensor B4Z-802A-SHOCK 12/13/2001 Interactive Technologies, Inc. 2266 North Second Street North Saint Paul, MN 55109 (651) 777-2690 Interactive Technologies Inc FCC_REPT.DOC 12/13/01 10:50 AM FCC ID: B4Z-802A-SHOCK Page 3 of 23 1. INTRODUCTION4 2. STATEMENT OF COMPLIANCE4 3. LAB MEASUREMENTS DISCUSSION / TEST NOTES7 3.1 Test Notes7 3.1.1 Transmissions shall cease within 5 seconds of activation [ §15.231(a)(2) ]7 3.1.2 Supervisory Calculation [ §15.231(a)(3) ]9 3.1.3 Duty Cycle Correction Factor [§15.231(b)(2) and §15.35(c)]9 3.1.4 Bandwidth Measurement [ §15.231(c) ]12 3.1.5 Emissions Measurements16 3.1.5.1 Radiated Emissions Summary16 3.1.5.2 FCC Emissions Calculation16 3.1.5.2.1 Terms16 3.1.5.2.2 Example Calculation16 3.1.5.3 Radiated Emissions17 3.1.5.4 Forbidden Bands17 Interactive Technologies Inc FCC_REPT.DOC 12/13/01 10:50 AM FCC ID: B4Z-802A-SHOCK Page 4 of 23 1. Introduction This device is a shock sensor with a transmitter for use in a wireless security system. The unit is powered by one 3V battery. The transmitter’s frequency is crystal controlled and is not adjustable by the user. The device measures approximately 5” in width, 1.5” in depth and 1.25′′ in height. The unit weighs approximately 2.6 ounces with out the battery. We are requesting Certification under FCC Rules, Part 15, Subpart C, Paragraph 15.231. Please send comments/suggestions on the report format to: [email protected]. 2. Statement of Compliance §2.907Certification This is an application for certification §2.911Application a)This is an application and has been filed electronically with form 731. b)All information required has been supplied. c)The applicant has signed the application (electronically). d)The technical data has been signed. (See Radiated Emissions) e)Applicant signature block on electronic form 731 completed by officer of the company or authorized company personnel. f) The appropriate fee has been paid electronically with VISA on 12/13/01. §2.915Grant This application demonstrates that all applicable technical standards have been met and a grant of this application will serve the public interest. §2.925Label Each piece of equipment for which authorization will be granted will be uniquely identified with “FCC ID: B4Z-802A-SHOCK.” The required statement will appear with the FCC ID on the product and, although not required, in the installation instructions. See Exhibit A, PDF file id_label.pdf Interactive Technologies Inc FCC_REPT.DOC 12/13/01 10:50 AM FCC ID: B4Z-802A-SHOCK Page 5 of 23 §2.947Measurement Procedure a)The measurement procedure follows ANSI C63.4 procedure. Procedural notes are contained in the laboratory report. d)A list of test equipment used is contained in the laboratory report. §2.948Description of Measurement Facilities Measurements were performed at TUV Testing Services Open Test Site. The FCC keeps a full description of the measurement facilities on file. TUV’s acceptance and approval is dated as December 5, 1993 in a letter received from the FCC. The address of the test facility is: TUV Product Service 19035 Wild Mountain Road Taylors Falls, MN 55084-1758 Phone: 651-638-0297 Contact:Joel Schneider Test Engineer in Charge See Exhibit F, PDF file test_pho.pdf for sketch of measurement setup §2.1033Application for Certification a)Form 731 has been electronically filed on 12/13/01. Items that did not apply were left blank. b)This technical report contains the following information where applicable. 1)Full name and mailing address of manufacturer and applicant for certification: Interactive Technologies Inc 2266 North Second Street North Saint Paul, MN 55109 2)FCC Identifier: B4Z-802A-SHOCK 3)Copy of installation instructions: See Exhibit G, PDF file: user_man.pdf 4)Brief Description of circuit functions and device operation: See Exhibit I, PDF file op_desc.pdf See Exhibit D, PDF file schemat.pdf for schematics (page 1) and parts placement (page 2) diagrams. Interactive Technologies Inc FCC_REPT.DOC 12/13/01 10:50 AM FCC ID: B4Z-802A-SHOCK Page 6 of 23 5) Block Diagram See Exhibit C, PDF file block.pdf. 6)Report of the measurements of radiation and conducted emissions: This document. 7)Photographs External: See Exhibit B, PDF file extern.pdf Internal: See Exhibit H, PDF file intern.pdf 8)Peripheral or Accessory devices: This is not applicable since this device is stand-a- lone product. 9) Transition Rules This application is not pursuant to the transition rules of §15.37 10)Emergency Broadcast decoding: This is not applicable to device in this application. 11)Application for direct sequence spread spectrum devices... This is not applicable to device in this application. 12)Application for scanning receivers... This is not applicable to device in this application. c)Composite Systems This is not applicable to device in this application. Interactive Technologies Inc FCC_REPT.DOC 12/13/01 10:50 AM FCC ID: B4Z-802A-SHOCK Page 7 of 23 3. Lab Measurements Discussion / Test Notes 3.1 Test Notes 3.1.1 Transmissions shall cease within 5 seconds of activation [ §15.231(a)(2) ] In the event of an alarm, 8 packets are sent in a transmission. The packet duration is, at most, 30 mS, see Duty Cycle Correction Factor [§15.231(b)(2) and §15.35(c)]. The time between packets random between 100 mS and 450 mS so the length of the longest transmission is: 8*30mS + 7*450mS = 3.39 seconds. The following plot shows a packet transmission that concludes in less than 5 seconds. Interactive Technologies Inc FCC_REPT.DOC 12/13/01 10:50 AM FCC ID: B4Z-802A-SHOCK Page 9 of 23 3.1.2 Supervisory Calculation [ §15.231(a)(3) ] As permitted, this device will t…

Text truncated - open the document above for the full version.

Test Setup Photos

Interactive Technologies Inc 12/13/01 6:14 AM FCC ID: B4Z-802A-SHOCK C:\WINNT\Profiles\Kenl.Nelson\Desktop\FCC Documintation\Submittles\Us Shock\peices\TEST_PHO.DOC 0.8 Meters EUT Receiving Antenna 3 Meters EXHIBIT F Test Setup Sketch for Radiated Emissions 1 Meter

Contact Information

Applicant

Konstantin Khrustov(Compliance Leader)
[email protected]949-737-7815Fax: 949-737-7882

Technical Contact

Interactive Technologies Inc.Ken L Nelson
[email protected]651-779-4825

2266 North Second Street · North St. Paul, Minnesota · United States

Test Firm

TUV SUD America - Product ServiceJoel Schneider
[email protected]651-604-4582Fax: 651-638-0298

Technical Specifications

#Rule PartsFrequency RangePower Output
115C319.5 MHz - 319.5 MHz-

Other Applications from UTC Fire & Security Americas Corporation, Inc.

AV-3G - FCC ID B4Z-944-3G - UTC Fire & Security Americas Corporation, Inc.
B4Z-944-3G

AV-3G

May 04, 2015

Equipment Class

PCB - PCS Licensed Transmitter
AVO-BT - FCC ID B4Z-962-BT - UTC Fire & Security Americas Corporation, Inc.
B4Z-962-BT

AVO-BT

May 04, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
AVO-ZW - FCC ID B4Z-959-ZW - UTC Fire & Security Americas Corporation, Inc.
B4Z-959-ZW

AVO-ZW

Apr 29, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
AVO-BTWIFI - FCC ID B4Z-958-BTWI - UTC Fire & Security Americas Corporation, Inc.
B4Z-958-BTWI

AVO-BTWIFI

Apr 29, 2015

Equipment Class

DTS - Digital Transmission System
PIR Security System Transmitter - FCC ID B4Z-680F-PIR - UTC Fire & Security Americas Corporation, Inc.
B4Z-680F-PIR

PIR Security System Transmitter

Dec 01, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter