Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
May 09, 2011
Application Purpose
Original Equipment
Date of Application
May 09, 2011
Equipment Note
Phone
Frequency Range
1850.20000000 - 1909.80000000
Company
HP Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Guide Intellectual property notices © 2009–2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Adobe and Adobe Acrobat are trademarks of Adobe Systems Incorporated. Amazon, Amazon MP3, and the Amazon MP3 logo are trademarks of Amazon.com, Inc. or its affiliates. Bluetooth is a trademark owned by its proprietor and used by Hewlett-Packard Company under license. Facebook is a registered trademark of Facebook, Inc. Google, Gmail, Google Maps, and YouTube are trademarks of Google, Inc. LinkedIn and the LinkedIn logo are registered trademarks of LinkedIn Corporation in the United States and/or other countries. Microsoft, Windows, Windows Vista, ActiveSync, Excel, and PowerPoint are trademarks of the Microsoft group of companies. PDF View is provided by Documents To Go ® , a product of DataViz, Inc. (dataviz.com). Quickoffice is a registered trademark of Quickoffice, Inc. Yahoo! and Yahoo! Mail are registered trademarks of Yahoo! Inc. All other brand and product names are or may be trademarks of their respective owners. All screen images simulated. Disclaimer and limitation of liability Hewlett-Packard, Inc. and its suppliers assume no responsibility for any damage or loss resulting from the use of this guide. Hewlett-Packard, Inc. and its suppliers assume no responsibility for any loss or claims by third parties that may arise through the use of this software. Hewlett-Packard, Inc. and its suppliers assume no responsibility for any damage or loss caused by deletion of data as a result of malfunction, dead battery, or repairs. Be sure to make backup copies of all important data on other media to protect against data loss. Patent pending. This product also is licensed under United States patent 6,058,304. Email, mobile number, and related information required for setup and activation. Actual speeds may vary. Required data services sold separately; unlimited plan recommended and may be required. Not all web content may be available. Open Source License information You can view the Open Source License terms on your smartphone. Tap the center of the gesture area and then tap the Launcher icon. Swipe left until the PDF View icon appears. Tap PDF View and then tap Open Source Information.pdf. You can also view the file on your computer. Connect your smartphone to your computer with the USB cable. On your smartphone, tap USB Drive. On your computer, locate and double-click the removable drive named for your smartphone. To locate the drive, do the following for your operating system: • Windows Vista/Windows 7: Open Computer. • Windows XP: Open My Computer. • Mac: Open Finder. • Linux (Ubuntu): The drive is displayed on the desktop. • Other Linux distribution: The location of the drive may vary by system. After you open the drive, double-click the file Open Source Information.pdf. Recycling and disposal This symbol indicates that HP products should be recycled and not be disposed of in unsorted municipal waste. HP products should be sent to a facility that properly recycles electrical and electronic equipment. For information on environmental programs visit hp.com/environment or recyclewirelessphones.com/. As part of HP’s corporate commitment to be a good steward of the environment, we strive to use environmentally friendly materials, reduce waste, and develop the highest standards in electronics recycling. v. 0.0 Contents3 Contents Chapter 3Basics 6Get to know your smartphone 8Set up your smartphone 8Turn your smartphone on/off Chapter 4Just Type 12Just Type overview 12Get in touch with a contact Chapter 5Work with applications 14Open applications 15Use the menus 16Enter and save information 17View and work with notifications Chapter 6Phone 20Make calls 21Receive calls 21Use voicemail 22What can I do during a call? 22Use a phone headset Chapter 7Email, text, multimedia, and instant messaging 26Email 27Messaging: Text and multimedia messaging 28Messaging: Instant messaging Chapter 8Contacts, Calendar, and other personal information 32Contacts 34Calendar Chapter 9Photos, videos, and music 36Camera 36Photos 37Videos 37Music 39Amazon MP3 Chapter 10 Web and wireless connections 42Wi-Fi 42Web 42Bluetooth ® wireless technology 4Contents Chapter 11 Documents 46PDF View Chapter 12 Preferences 48Screen & Lock 48Sounds & Ringtones Chapter 13 Learn More 52While using your phone Regulatory and safety information Index Chapter 3 : Basics5 Basics You’re about to discover the many things about your HP XXX that will help you better manage your life and have fun, too. Read this chapter to learn about your smartphone and take the few easy steps to set it up and get it running. Then learn about the gestures that make moving around on your smartphone easy. Later, after you’re familiar with your smartphone, you’ll want to personalize the settings and add applications to make it uniquely yours. In this chapter 6Get to know your smartphone 8Set up your smartphone 8Turn your smartphone on/off 6Chapter 3 : Basics Get to know your smartphone Slide out the keyboard • Hold the smartphone as shown below and gently push up. Front view 1Earpiece: When you hold your smartphone up to your ear when on a call, the screen darkens. 2Volume 3Gesture area: Make the back gesture and begin other gestures here. 4Keyboard: 5Speaker (on back) 6Camera lens: For live video calling only. 7Charger/microUSB connector: Connect the small end of the USB cable to charge your smartphone battery or copy files. 8Microphone (on front) 9Touchscreen: Tap and make other gestures directly on the screen. TIP When you are on a call or using data services to check email, browse the web, and so on, you may experience better sound or connection quality if you keep the keyboard slid out. Chapter 3 : Basics7 NOTE The volume you set for each individual audio component is saved automatically, whether the audio component is the earpiece of your smartphone, a wired headset, a wireless headset that uses B…

Text truncated - open the document above for the full version.

Cover Letter(s)

Hewlett‐Packard Company ∗ (408) 617‐7000 ∗ 950 W. Maude Ave. Sunnyvale, Ca. 94085 March 31, 2011 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: B94HHF30CV To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Block Diagram Schematic Diagram Theory of Operation Tune-Up Procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments for 180 days from the date of the Grant of Equipment Authorization: External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and such information will be available for public review once the grant of equipment authorization is issued. Sincerely, Helen Zhao Sr. Regulatory Compliance Engineer [email protected] Office: 408-617-6508 Hewlett Packard Company, Palm GBU 950 W. Maude Avenue Sunnyvale, CA 94085-2801 USA

Cover Letter(s)

Authorizationon Behalf of Hewlett-Packard Company For the US Federal Communications Commission Office of Engineering and TechnologyandOther FCC Programs and Offices 1. I, David P. Adams, am Canada/USA Technical Regulations Manager for Hewlett-Packard Company (“Hewlett-Packard”) and Applicant/Grantee Contact of Recordfor Hewlett-Packard together with its subsidiaries and affiliates worldwide (collectively,“HP”) for HP’s dealings withthe United States Federal Communications Commission (“FCC”). I am duly authorized by HP to make this Authorization on HP’s behalf. 2. This Authorization will designate the person named below to act on my behalf and HP’s behalf as authorized agent and representative, until further notice, with the additional power to designate one or more third party agents for HP with regard to particular matters and applications. Allacts carried out and requests made by this named representativerelating to any matter before the FCC, including requests for confidentiality,shall have the same effect as mine. Name:Helen Zhao Title:Sr. RegulatoryCompliance Engineer Address:Hewlett-Packard Company, Palm GBU 950 WestMaude Avenue Sunnyvale, CA 94805 Telephone:408-617-6508 E-mail:[email protected] 3. Questions aboutthe scope and effect ofthis Authorization should be addressed as follows: David P. Adams Canada/USA Region Technical Regulations Manager 1501 Page Mill Road, MS1222 Palo Alto, CA 94304-1126 650.857.4423 Telephone 650.857.4882 Fax [email protected] 4. I declare under penalty of perjury that the foregoing is true and correct, and that this Authorization was executed atPalo Alto, California, on the date indicated below my signature. ____________________________ Signature David P. Adams Canada/USA Technical Regulations Manager Hewlett-Packard Company _March 31, 2011_______________ Date

ID Label/Location Info

FCC ID and Location The FCC ID is located on a label inside the battery compartment. FCC ID label inside Battery Compartment

RF Exposure Info

FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE STD 1528:2003 IC RSS-102 ISSUE 4 SAR EVALUATION REPORT For PHONE MODEL: HSTNH-F30CV FCC ID: B94HHF30CV IC: 3905A-HHF30CV REPORT NUMBER: 11U13622-1, Revision A ISSUE DATE: April 27, 2011 Prepared for HEWLETT PACKARD COMPANY, PALM GBU 950 MAUDE AVENUE SUNNYVALE, CA. 94085 UNITED STATES Prepared by COMPLIANCE CERTIFICATION SERVICES (UL CCS) 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 REPORT NO: 11U13622-1A DATE: April 27, 2011 FCC ID: B94HHF30CV IC: 3905A-HHF30CV Page 2 of 113 COMPLIANCE CERTIFICATION SERVICES (UL CCS) FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL CCS. Revision History Rev. Issue Date Revisions Revised By -- April 25, 2011 Initial Issue -- A April 27, 2011 Revised IC ID Aliza Zaffar REPORT NO: 11U13622-1A DATE: April 27, 2011 FCC ID: B94HHF30CV IC: 3905A-HHF30CV Page 3 of 113 COMPLIANCE CERTIFICATION SERVICES (UL CCS) FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL CCS. TABLE OF CONTENTS FCC OET BULLETIN 65 SUPPLEMENT C 01-01 ....................................................................................... 1 1. ATTESTATION OF TEST RESULTS.................................................................................................. 5 2. TEST METHODOLOGY ...................................................................................................................... 6 3. FACILITIES AND ACCREDITATION.................................................................................................. 6 4. CALIBRATION AND UNCERTAINTY................................................................................................. 7 4.1. MEASURING INSTRUMENT CALIBRATION ............................................................................. 7 4.2. MEASUREMENT UNCERTAINTY .............................................................................................. 8 5. EQUIPMENT UNDER TEST ............................................................................................................... 9 6. SYSTEM SPECIFICATIONS ............................................................................................................. 10 7. LIQUID PARAMETERS..................................................................................................................... 11 7.1. LIQUID CHECK RESULTS ....................................................................................................... 12 8. SYSTEM VERIFICATION.................................................................................................................. 32 8.1. SYSTEM CHECK RESULTS .................................................................................................... 33 9. SAR MEASUREMENT PROCEDURES............................................................................................ 35 10. KDB 941225 TEST REDUCTION CONSIDERATION.................................................................. 36 11. RF OUTPUT POWER VERIFICATION......................................................................................... 37 11.1. GSM .......................................................................................................................................... 37 11.2. CDMA2000 1xRTT .................................................................................................................... 38 11.3. CDMA200 1xEv-Do ................................................................................................................... 39 11.3.1. Release 0 (Rel. 0)..............................................................................................................39 11.3.2. Revision A (Rev. A) ........................................................................................................... 40 11.4. WIFI RF OUTPUT POWER....................................................................................................... 41 11.5. BLUETOOTH RF OUTPUT POWER ........................................................................................ 43 12. SUMMARY OF SAR TEST RESULTS ......................................................................................... 44 12.1. GSM850 .................................................................................................................................... 45 12.2. GSM1900 .................................................................................................................................. 47 12.3. CDMA2000 CELL BAND........................................................................................................... 49 12.4. CDMA2000 PCS BAND ............................................................................................................ 52 12.5. WIFI 2.4 GHz BAND.................................................................................................................. 55 12.6. WIFI 5 GHz BANDS .................................................................................................................. 57 REPORT NO: 11U13622-1A DATE: April 27, 2011 FCC ID: B94HHF30CV IC: 3905A-HHF30CV Page 4 of 113 COMPLIANCE CERTIFICATION SERVICES (UL CCS) FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL CCS. 13. Worst-case SAR Plots................................................................................................................. 59 14. KDB 648474 SIMULTANEOUS TRANSMISSION CONSIDERATION ........................................ 95 15. SIMULTANEOUS SAR TEST DATA SUMMARY ............................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Date/Time: 3/11/2011 9:04:19 AM Test Laboratory: UL CCS System Check_D1900V2_SN 5d043 DUT: Dipole D1900V2; Type: D1900V2; Serial: 5d043 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1900 MHz; σ = 1.351 mho/m; ε r = 41.356; ρ = 1000 kg/m 3 Phantom section: Flat Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(7.42, 7.42, 7.42); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: SAM with CRP; Type: SAM; Serial: 1602 - Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595) D1900V2/Pin=100 mW/Area Scan (5x6x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 5.051 mW/g D1900V2/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 62.704 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 7.091 W/kg SAR(1 g) = 3.92 mW/g; SAR(10 g) = 2.09 mW/g Maximum value of SAR (measured) = 5.248 mW/g Date/Time: 3/11/2011 9:19:06 AM Test Laboratory: UL CCS System Check_D1900V2_SN 5d043 DUT: Dipole D1900V2; Type: D1900V2; Serial: 5d043 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 D1900V2/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 5.245 mW/g Date/Time: 3/14/2011 10:35:58 AM Test Laboratory: UL CCS System Check_D1900V2_SN 5d043 DUT: Dipole D1900V2; Type: D1900V2; Serial: 5d043 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1900 MHz; σ = 1.392 mho/m; ε r = 40.801; ρ = 1000 kg/m 3 Phantom section: Flat Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(7.42, 7.42, 7.42); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: SAM with CRP; Type: SAM; Serial: 1602 - Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595) D1900V2/Pin=100 mW/Area Scan (5x6x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 5.247 mW/g D1900V2/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 61.832 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 7.370 W/kg SAR(1 g) = 4.07 mW/g; SAR(10 g) = 2.17 mW/g Maximum value of SAR (measured) = 5.426 mW/g 0 dB = 5.430mW/g Date/Time: 3/14/2011 11:08:23 AM Test Laboratory: UL CCS System Check_D1900V2_SN 5d043 DUT: Dipole D1900V2; Type: D1900V2; Serial: 5d043 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 D1900V2/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 5.430 mW/g Date/Time: 3/15/2011 10:52:48 AM Test Laboratory: The name of your organization System Check_D835V2_SN 4d002 DUT: D835V2; Type: D835V2; Serial: 4d002 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.982 mho/m; ε r = 53.5; ρ = 1000 kg/m 3 Phantom section: Flat Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(8.78, 8.78, 8.78); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: ELI 4.0; Type: QDOVA001BA; Serial: xxxx - Measurement SW: DASY52, V52.2 Build 0;Postprocessing SW: SEMCAD X, V14.2 Build 2Version 14.2.2 (1685) (Deployment Build) D835V2/Pin=100 mW/Area Scan (5x6x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.15 mW/g D835V2/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 34.8 V/m; Power Drift = -0.025 dB Peak SAR (extrapolated) = 1.44 W/kg SAR(1 g) = 0.961 mW/g; SAR(10 g) = 0.631 mW/g Maximum value of SAR (measured) = 1.17 mW/g 0 dB = 1.17mW/g Date/Time: 3/15/2011 11:07:19 AM Test Laboratory: The name of your organization System Check_D835V2_SN 4d002 DUT: D835V2; Type: D835V2; Serial: 4d002 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 D835V2/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 1.17 mW/g Date/Time: 3/16/2011 8:39:26 AM Test Laboratory: UL CCS System Check_D835V2_SN 4d002 DUT: D835V2; Type: D835V2; Serial: 4d002 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.986 mho/m; ε r = 53.891; ρ = 1000 kg/m 3 Phantom section: Flat Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(8.78, 8.78, 8.78); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: ELI 4.0; Type: QDOVA001BA; Serial: xxxx - Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595) D835V2/Pin=100 mW/Area Scan (5x6x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.247 mW/g D835V2/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 36.018 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.560 W/kg SAR(1 g) = 1.03 mW/g; SAR(10 g) = 0.677 mW/g Maximum value of SAR (measured) = 1.261 mW/g Date/Time: 3/16/2011 8:54:13 AM Test Laboratory: UL CCS System Check_D835V2_SN 4d002 DUT: D835V2; Type: D835V2; Serial: 4d002 Communication Sys…

Text truncated - open the document above for the full version.

RF Exposure Info

Date/Time: 3/17/2011 9:35:01 PM Test Laboratory: UL CCS GSM850_Head DUT: Plam; Type: n/a; Serial: n/a Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8.00018 Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; ε r = 42.008; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: SAM with CRP; Type: SAM; Serial: 1602 - Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595) LHS_open/Touch_M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.481 mW/g LHS_open/Touch_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm Reference Value = 22.604 V/m; Power Drift = 0.0072 dB Peak SAR (extrapolated) = 0.508 W/kg SAR(1 g) = 0.405 mW/g; SAR(10 g) = 0.307 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.453 mW/g Date/Time: 3/17/2011 10:03:15 PM Test Laboratory: UL CCS GSM850_Head DUT: Plam; Type: n/a; Serial: n/a Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8.00018 Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; ε r = 42.008; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: SAM with CRP; Type: SAM; Serial: 1602 - Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595) LHS_open/Tilt_M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.232 mW/g LHS_open/Tilt_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm Reference Value = 16.166 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 0.273 W/kg SAR(1 g) = 0.208 mW/g; SAR(10 g) = 0.159 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.239 mW/g Date/Time: 3/17/2011 6:34:10 PM Test Laboratory: UL CCS GSM850_Head DUT: Plam; Type: n/a; Serial: n/a Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8.00018 Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; ε r = 42.008; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: SAM with CRP; Type: SAM; Serial: 1602 - Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595) LHS_closed/Touch_M-ch/Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.461 mW/g LHS_closed/Touch_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm Reference Value = 22.830 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.548 W/kg SAR(1 g) = 0.428 mW/g; SAR(10 g) = 0.317 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.482 mW/g Date/Time: 3/17/2011 7:01:24 PM Test Laboratory: UL CCS GSM850_Head DUT: Plam; Type: n/a; Serial: n/a Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8.00018 Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; ε r = 42.008; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: SAM with CRP; Type: SAM; Serial: 1602 - Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595) LHS_closed/Tilt_M-ch/Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.396 mW/g LHS_closed/Tilt_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm Reference Value = 21.127 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 0.464 W/kg SAR(1 g) = 0.361 mW/g; SAR(10 g) = 0.270 mW/g Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.410 mW/g Date/Time: 3/17/2011 10:57:22 PM Test Laboratory: UL CCS GSM850_Head DUT: Plam; Type: n/a; Serial: n/a Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8.00018 Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; ε r = 42.008; ρ = 1000 kg/m 3 Phantom section: Right Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: SAM with…

Text truncated - open the document above for the full version.

RF Exposure Info

Date/Time: 3/14/2011 8:04:22 PM Test Laboratory: UL CCS GSM1900_Head DUT: Plam; Type: n/a; Serial: n/a Communication System: GSM1900; Frequency: 1880 MHz;Duty Cycle: 1:8.00018 Medium parameters used: f = 1880 MHz; σ = 1.374 mho/m; ε r = 40.966; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(7.42, 7.42, 7.42); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 - Phantom: SAM with CRP; Type: SAM; Serial: 1602 - Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595) LHS_open/Touch_M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.278 mW/g LHS_open/Touch_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm Reference Value = 14.385 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.374 W/kg SAR(1 g) = 0.242 mW/g; SAR(10 g) = 0.153 mW/g Maximum value of SAR (measured) = 0.295 mW/g Date/Time: 3/14/2011 8:22:39 PM Test Laboratory: UL CCS GSM1900_Head DUT: Plam; Type: n/a; Serial: n/a Communication System: GSM1900; Frequency: 1880 MHz;Duty Cycle: 1:8.00018 LHS_open/Touch_M-ch/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 0.034 mW/g Date/Time: 3/14/2011 8:34:28 PM Test Laboratory: UL CCS GSM1900_Head DUT: Plam; Type: n/a; Serial: n/a Communication System: GSM1900; Frequency: 1880 MHz;Duty Cycle: 1:8.00018 Medium parameters used: f = 1880 MHz; σ = 1.374 mho/m; ε r = 40.966; ρ = 1000 kg/m 3 Phantom section: Left Section Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C DASY5 Configuration: - Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Probe: EX3DV4 - SN3686; ConvF(7.42, 7.42, 7.42); Calibrated: 1/24/2011 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1239; Calibrated: 11/17/2010 …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Richard P Tarsio(US Canada Technical Regulations)
[email protected]970-898-8713Fax: 000-000-0000

Technical Contact

Hewlett Packard Company, Palm GBUHelen Zhao
[email protected](408) 617-6508

950 W. Maude Ave. · Sunnyvale, California

Non-Technical Contact

Hewlett Packard Company, Palm GBUHelen Zhao
[email protected](408) 617-6508

Test Firm

Compliance Certification ServicesThu Chan
[email protected]510-771-1122Fax: 510-661-0888

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
624E1.85 GHz - 1.91 GHz1.22 W244KG7W2.5 ppm
Confidentiality
Long Term
Grant Notes
Output power is ERP for Part 22 and EIRP for Part 24. This device contains functions that are not operational in U.S Territories. Filings under this FCC ID are applicable only for US operations. SAR compliance for body operating configurations is limited to the specific configurations tested under this FCC ID. For satisfying FCC RF exposure compliance requirements, near-body operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna, and the user's body. End-users must be informed of the near-body operating requirements for satisfying RF exposure compliance. The highest reported SAR values for filings under this FCC ID are: 800 MHz: head 0.54 W/kg, body 1.13 W/kg; 1900 MHz: head 0.42 W/kg, body 1.40 W/kg. HAC Rating: M3/T4-2007

Other Applications from HP Inc.

B94HNI70CBVN

Model HSN-I70C

Aug 14, 2026

Equipment Class

CBE - Citizens Band End User Devices
B94HNQ38C3BEK

Notebook PC

Jun 03, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
B94HNI65C4BLV

Notebook Computer HSN-I65C-4

Apr 23, 2026

Equipment Class

PCB - PCS Licensed Transmitter
B94HNI67C4BLV

Notebook Computer HSN-I67C-4

Apr 23, 2026

Equipment Class

CBE - Citizens Band End User Devices
B94HNI66C4SPY

Model HSN-I66C-4

Feb 03, 2026

Equipment Class

PCB - PCS Licensed Transmitter