FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. MOTREX CO., LTD./
  3. BP9-RESARMT

BP9-RESARMTRemote Engine Start Assembly

MOTREX CO., LTD.
Remote Engine Start Assembly - FCC ID BP9-RESARMT - MOTREX CO., LTD.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 15, 2013
Application Purpose
Original Equipment
Date of Application
Sep 15, 2013
Equipment Note
Remote Engine Start Assembly
Frequency Range
433.92000000 - 433.92000000
Company
MOTREX CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

COVER  USER’S  GUIDE RESA (Remote  Engine  Start  Assembly) *  %HIRUHXVLQJWKHSURGXFWUHDGWKHVDIHW\FDXWLRQVDQGZDUQLQJV FDUHIXOO\ DQGXVHWKLVSURGXFWVDIHO\*  Images  shown  within  this  user’s  guide  may  appear  slightly  different  as  they  do  in  real  life. *  7KHGHVLJQDQGVSHFLILFDWLRQRIWKLVSURGXFWPD\FKDQJHZLWKRXW SULRU QRWLILFDWLRQIRUSURGXFWLPSURYHPHQW *  RESA  may  not  operate  in  the  following  conditions.  Driver  caution  is  required.  Ͳ When  driving  near  or  between  high Ͳ rise  buildings Ͳ When  in  underground  parking  structures,  tunnels  and  other  enclosed  environments Ͳ In  bad  weather  conditions,  such  as  fog,  heavy  rain,  or  heavy  snow Ͳ When  there  are  strong  radio  waves  in  the  vicinity Ͳ When  the  battery  life  is  low Ͳ When  the  distance  with  the  vehicle  is  too  far Ͳ When  the  vehicle  is  at  a  busy  intersection Ͳ When  the  vehicle  has  thick  window  tints  or  heated  windows [Warnings]Ͳ The  LOCK  function  on  RESA  is  used  to  prevent  states  of  improper  operation.  The  driver  is  fully  responsible  to  perform  operations  to  safely  drive  the  vehicle.  Ͳ Take  caution  so  that  liquids  are  not  introduced  into  RESA. Ͳ RESA  may  not  properly  operate  if  the  distance  with  the  vehicle  is  too  far. Ͳ RESA  may  not  properly  operate  if  the  battery  life  is  insufficient.  Ͳ Do  not  dissemble  the  RESA  and  its  components  or  subject  it  to  severe  chock. Ͳ Excessively  operating  RESA  may  cause  battery  life  to  be  consumed  quickly. Ͳ When  not  properly  operating,  check  the  Lock/Unlock  button  on  RESA. Ͳ Make  sure  to  fully  understand  the  functions  of  this  product  so  that  the  product  and  its  use  does  not  impede  vehicle  driving.  Ͳ When  parking  after  using  this  product,  the  gear  position  must  be  shifted  to  P.  For  safety,  do  not  use  the  remote  engine  start  function  when  parking  on  roads  on  a  slant  or  incline.  Ͳ If  the  engine  does  not  start  due  to  product  malfunction,  use  the  genuine  KEY  to  start  the  engine  and  visit  your  place  of  installatio n  or  maintenance  center  to  receive  repair/inspection. Ͳ When  assigning  or  transferring  this  product  to  a  third  party,  make  sure  to  transfer  the  product  with  its  functions  disabled  and  that  the  driver  fully  understands  the  functions  of  this  product. Ͳ When  storing  this  product  for  a  prolonged  period  of  time,  make  sure  to  store  it  in  a  moisture Ͳ less  environment. Ͳ The  duration  of  remote  ignition  time  is  up  to  10  minutes.  The  customer  must  check  whether  the  product  is  properly  operating  at  all  times. Safety  Warnings  and  Cautions Ͳ This  product  shall  only  be  used  as  an  assistance  tool  equipped  with  convenience  features.  The  driver  shall  be  responsible  for  any  and  all  forms  of  theft  and  damage  and  the  manufacturer  shall  have  no  consequential  civil  or  criminal  responsibility. Ͳ You  must  carry  your  genuine  key  at  all  times  in  order  to  automatical ly  open  doors  and  switch  back  to  normal  engine  start  mode.  Ͳ This  product  is  not  waterproof. Ͳ Do  not  use  this  product  in  ways  not  directly  expressed  within  this  User’s  Guide. Ͳ Store  this  product  in  places  that  are  out  of  reach  of  infants  and  children. Ͳ When  storing  this  product  for  a  prolonged  period  of  time,  make  sure  to  store  it  in  a  moisture Ͳ less  environment. Ͳ The  duration  of  remote  ignition  time  is  up  to  10  minutes.  The  customer  must  check  whether  the  product  is  properly  operating  at  all  times. Ͳ This  product  is  highly  sensitive  to  temperatures  and  surrounding  environments.  Severe  changes  in  temperature  may  result  in  discharge  of  the  internal  battery. Ͳ If  the  alarm  sound  does  not  occur  and  the  product  does  not  properly  operate  due  to  product  defects  or  errors,  please  visit  your  place  of  purchase  to  receive  inspections.  Ͳ Upon  loss  of  the  remote  controller,  visit  your  place  of  purchase.  Ͳ Upon  replacing  your  product  due  to  loss  of  remote  controller  or  device  malfunctio n  the  vehicle  may  be  reset  and  contents  stores  in  the  memory  may  be  erased. Verifying  Components <Remote  Controller>  <Vehicle  RF  Module> Model:  RESA Ͳ Remote  Model:  RESA Ͳ Module <  Module  Power  Cable> <RF  Antenna  Cable> <RF  Antenna> Operating  Conditions  of  RESA  System Vehicle  Conditions  Ͳ The  vehicle  must  be  parked  with  the  gear  positioned  to  P. Ͳ All  vehicle  doors,  including  the  hood  and  trunk,  must  be  closed  and  the  doors  must  be  locked.  Ͳ The  product  will  not  operate  if  the  gear  is  not  positioned  to  P  or  when  the  vehicle  is  in  motion. Operating  C onditions Ͳ The  duration  of  remote  ignition  time  is  up  to  10  minutes.  Ͳ If  the  doors  are  opened  by  force  in  a  state  when  the  door  lock  is  in  boundary  mode,  then  remote  engine  start  is  automatically  disabled. Normal  Engine  Start  Swit…

Text truncated - open the document above for the full version.

Cover Letter(s)

1-1103, Ace Hi-Tech City Bldg., 55-20, Mullae-dong 3ga, Yeongdeungpo-gu, Seoul, Korea 150-972 T: +82 (707) 123 1374 / F: +82 (2) 3439 1360 Date: July 2, 2013 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, MOTREX CO., LTD., hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project : - Product : Remote Engine Start Assembly - Model name : RESA-Remote - FCC ID : BP9-RESARMT We affirm that between SIEMIC and MOTREX CO., LTD., any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This authorization is valid until further written notice from the applicant. Sincerely Yours, _____________________________________ Hyoung-hwan Lee /Representative /MOTREX CO., LTD.

Cover Letter(s)

1-1103, Ace Hi-Tech City Bldg., 55-20, Mullae-dong 3ga, Yeongdeungpo-gu, Seoul, Korea 150-972 T: +82 (707) 123 1374 / F: +82 (2) 3439 1360 FCC Confidentiality Request Letter Date: July 2, 2013 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia MD 21046 Subject: Permanent Confidentiality Request for FCC ID: BP9-RESARMT We hereby request confidential treatment of information accompanying this application as outlined below:  Block diagram  Schematics  Operation Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely Yours, _____________________________________ Hyoung-hwan Lee /Representative /MOTREX CO., LTD.

External Photos

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0119 EMC compliance Ltd. Page: 20 of 20 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea, 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. External photos of EUT

ID Label/Location Info

FCC ID LABEL 1. FCC ID label drawing 2. FCC ID label location MOTREX CO., LTD. Model : RESA-Remote FCC ID : BP9-RESARMT Made in Korea

Internal Photos

http://www.emc2000.co.kr EMCComplianceLtd.480-5 Sin-dong, Yeongtong-gu, Suwon-city, Gyeonggi-do, 443-390, Korea TEL: 82 31 336 9919FAX: 82 505 299 8311 This test report shall not be reproduced, except in full, without the written approval. Report No.: EMC-CE-4176 Page: 25 of 26 Inside http://www.emc2000.co.kr EMCComplianceLtd.480-5 Sin-dong, Yeongtong-gu, Suwon-city, Gyeonggi-do, 443-390, Korea TEL: 82 31 336 9919FAX: 82 505 299 8311 This test report shall not be reproduced, except in full, without the written approval. Report No.: EMC-CE-4176 Page: 26 of 26 Main Board

Test Report

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0119 EMC compliance Ltd. Page: 1 of 21 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea, 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. FCC TEST REPORT Test report No: EMC- FCC- R0119 FCC ID: BP9-RESARMT Type of equipment: Remote Engine Start Assembly Model Name: RESA-Remote Applicant: MOTREX CO., LTD. FCC Rule Part(s): FCC Part 15 Subpart C Section 15.209, Section 15.231 Frequency Range: 433.92 MHz Test result: Complied The above equipment was tested by EMC compliance Testing Laboratory for compliance with the requirements of FCC Rules and Regulations. The results of testing in this report apply to the product/system which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Date of test: July 10, 2013 ~ July 12, 2013 Issued date: July 15, 2013 Tested by: Approved by: . SON, MIN GI YU, SANG HOON http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0119 EMC compliance Ltd. Page: 2 of 21 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea, 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. [ Contents ] 1. Client information.................................................................................................. 3 2. Laboratory information ........................................................................................... 4 3. Description of E.U.T. ............................................................................................... 5 3.1 Basic description ................................................................................................ 5 3.2 General description ............................................................................................. 5 3.3 Test frequency ................................................................................................... 6 3.4 Test Voltage ..................................................................................................... 6 4. Summary of test results ............................................................................................ 7 4.1 Standards & results ............................................................................................. 7 4.2 Uncertainty ...................................................................................................... 7 5. Test results .......................................................................................................... 8 5.1 Antenna Requirement ........................................................................................... 8 5.2 Field strength of Fundamental ................................................................................. 9 5.3 Spurious Emission ............................................................................................. 11 5.4 Receiver Spurious Emission .................................................................................. 14 5.5 Bandwidth of Operation Frequency........................................................................... 16 5.6 Transmission Time ............................................................................................. 17 5.7 Occupied Bandwidth .......................................................................................... 18 6. Test equipment used for test .................................................................................... 19 http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0119 EMC compliance Ltd. Page: 3 of 21 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea, 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. 1. Client information Applicant: MOTREX CO., LTD. Address: 1-1103, Ace Hi-Tech City B/D, 55-20, Mullae-dong 3-ga, Yeongdeungpo- gu, Seoul, Korea 150-972 Telephone number: 82-70-7123-1374 Facsimile number : 82-2-3439-1360 Contact person: Hyoung-hwan Lee Manufacturer: PLK TECHNOLOGY Address: 12th Floor, INNOPLEX Bldg, 57-5, Yangsan-ro, Yeongdeungpo-Gu, Seoul 150-103, Korea http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0119 EMC compliance Ltd. Page: 4 of 21 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea, 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. 2. Laboratory information Address EMC Compliance Ltd. 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea, Telephone Number: 82 31 336 9919 Facsimile Number: 82 31 336 4767 Certificate CBTL Testing Laboratory, KOLAS NO.: 231 FCC Filing No.: 508758 IC Filing No.: 8035A-2 VCCI Registration No.: C-1713, R-1606, T-258 SITE MAP SUWON-CITY EMC Compliance Ltd. http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0119 EMC compliance Ltd. Page: 5 of 21 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea, 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. 3. Description of E.U.T. 3.1 Basic description Applicant : MOTREX CO., LTD. Address of Applicant: 1-1103, Ace Hi-Tech City B/D, 55-20, Mullae-dong 3-ga, Yeongdeungpo-gu, Seoul, Korea 150-972 Manufacturer: PLK TECHNOLOGY Address of Manufacturer: 12th Floor, INNOPLEX Bldg, 57-5, Yangsan-ro, Yeongdeungpo-Gu, Seoul 150-103, Korea Type of equipment: Remote Engine Start Assembly Basic Model: RESA-Module Serial number: N/A 3.2 General description Frequency Range 433.92 MHz Type of Modulation GFSK Number of Channels 1 channel Antenna Gain -11.7 dBi Power supply DC 12 V Dimension 65 x 56 x 26 mm http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0119 EMC compliance Ltd. Page…

Text truncated - open the document above for the full version.

Test Setup Photos

http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0119 EMC compliance Ltd. Page: 19 of 20 480-5 Shin-dong, Yeongtong-gu, Suwon-city, Gyunggi-do, 443-390, Korea, 82 31 336 9919 (Main) 82 31 336 4767 (Fax) This test report shall not be reproduced except in full, Without the written approval. Test setup photos

Contact Information

Applicant

Chan Hyeon Kim(Senior Researcher)
[email protected]+82-10-5606-9233Fax: +82-2-6280-1170

Test Firm

EMC Compliance Ltdchangmin kim
[email protected]82313369919Fax: 82313364767

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from MOTREX CO., LTD.

BP9-MS500AK01

SMART DISPLAY

Jan 18, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
BP9-MS400AH01

SMART DISPLAY

Jan 17, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
BP9-MS400AK01

SMART DISPLAY

Jan 17, 2024

Equipment Class

DTS - Digital Transmission System
SMART DISPLAY - FCC ID BP9-MH300LK01 - MOTREX CO., LTD.
BP9-MH300LK01

SMART DISPLAY

Jan 04, 2024

Equipment Class

DTS - Digital Transmission System
Rear Seat Entertainment - FCC ID BP9-RS210A - MOTREX CO., LTD.
BP9-RS210A

Rear Seat Entertainment

Oct 17, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter