FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Salco Industries Inc/
  3. BZD-SST011198

BZD-SST011198

Salco Industries Inc
DSC - Part 15 Security/Remote Control Transmitter - FCC ID BZD-SST011198 - Salco Industries Inc
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 16, 1999
Application Purpose
Original Equipment
Date of Application
Jan 28, 1999
Frequency Range
303.87500000 - 303.87500000
Company
Salco Industries Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Operational Description

β†—

Schematics

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 31 of 48 Exhibit 8 Exhibit 8: User’s Manual MODEL SST SUPERVISED WIRELESS TRANSMITTER SALCO INDUSTRIES 263 FIELD END ROAD SARASOTA , FL 34240 12/01/98 COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 32 of 48 Exhibit 8 Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: β€’ Reorient or relocate the receiving antenna. β€’ Increase the separation between the equipment and receiver. β€’ Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. β€’ Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by SALCO INDUSTRIES can void the user's authority to operate the equipment. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 0004-0000-00345-4. Β© 1998 Salco Industries. FCC ID: BZD-SST011198 SALCO INDUSTRIES ___________________________________________________________________ This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: (1.0) This device may not cause harmful interference and (2.0) this device must accept any interference that may be received, including interference that may cause undesired operation. COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 33 of 48 Exhibit 8 I M P O R T A N T! ! This manual should be read and understood in its entirety before attempting to install or program the system. This manual has been developed by SALCO INDUSTRIES and this manual is intended for use only by its industrial and commercial trade customers and service personnel. The information presented in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. SALCO reserves the rights to make changes without further notice to the products specified herein to improve reliability, function, or design. SALCO radio controls provide a reliable communications link and fill an important need in portable or wireless signaling. However, there are some limitations, which must be observed. β€’ The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited ranges. β€’ Receivers may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. β€’ A receiver cannot respond to more than one transmitted signal at a time. β€’ Infrequently used radio links should be tested regularly to protect against undetected interference or fault. β€’ A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor, dealer, or private installer, and these facts should be communicated to the ultimate users. C A U T I O N ! The manufacturer strongly recommends that you test security equipment frequently. Over a period of time, no electronic products are better than the inspection and maintenance they receive. Therefore, from the time of installation, it is a good idea to test the supervised security system at least once a week. COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 34 of 48 Exhibit 8 TABLE OF CONTENTS 1.0 General Description 2.0Internal Controls A. User Modes 3.0System Power up and Test 4.0Maintenance 5.0Warning Notices 6.0Specifications 7.0Warranty COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 35 of 48 Exhibit 8 1.0 GENERAL DESCRIPTION The model SST supervised-wireless transmitter provides a reliable and cost-effective means of transmitting condition or event data from two external sensors to an associated wireless SALCO receiver processor system located up to 500 feet. The SST transmitter supervises the RF link hourly to maintain a high degree of readiness and reliability. In addition, the real time signaling capability of each SST transmitter allows for individual real time sensor status display at the receiver processor. The SST transmitter incorporates advanced microcomputer design with Nonvolatile memory, which allows user programmability of many features. Among the notable programmable features are single external sensor input activation or dual external sensor input activation with discrete reporting on each individual sensor. An internal proximity sensor is also incorporated for ease of activation or testing with an external magnet. The internal sensor can be programmed to activate zone 1, zone 2, or as a test zone. COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 36 of 48 Exhibit 8 2.0 INTERNAL CONTROLS Internal View 1. Sensor Input Port 2. Transmit Indicator 3. Magnetic Reed Sensor 4. Magnet 5. Battery 6. Programming Port - Used to connect transmitter to external sensors with dry contact closure of either normally open or normally closed contact type. - Illuminates when transmitter transmits a wireless alarm or test signal. - May be used i…

Text truncated - open the document above for the full version.

Block Diagram

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 6 of 48 Exhibit 4 Exhibit 4: Block Diagrams

External Photos

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 4 of 48 Exhibit 3 Exhibit 3: Photographs of Overall Appearance Front View of the SST COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 5 of 48 Exhibit 3 Back View of the SST

ID Label/Location Info

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 1 of 48 Exhibit 1 Exhibit 1: FCC ID Label Equipment Identification Label In accordance with the requirements of Sections 15.19 (a), 2.925 and 2.926 of the FCC Rules, the following information will be permanently affixed to the Salco Industries Model SST as shown in the photograph below. COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 2 of 48 Exhibit 1 Photograph showing label placement

Internal Photos

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 43 of 48 Exhibit 9 Exhibit 9: Internal Photographs Side A COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 44 of 48 Exhibit 9 Side B

Operational Description

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 47 of 48 Exhibit 12 Exhibit 12: Operational Description '' 15.203 Antenna Requirements The SST uses an antenna that is soldered directly to the main board. The same type as specified by the manufacturer can only replace this antenna.

Schematics

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 7 of 48 Exhibit 5 Exhibit 5: Schematic Diagrams

Test Report

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 8 of 48 Exhibit 6 Exhibit 6: Test Report TEST REPORT FROM: COMMUNICATION CERTIFICATION LABORATORY 1940 W. Alexander Street Salt Lake City, Utah 84119-2039 Type of Report: Certification TEST OF: SST FCC ID: BZD-SST011198 To FCC PART 15, Subpart C Section 15.231 Test Report Serial No: 73-6741 Applicant: Salco Industries 263 Field End Road Sarasota, Florida 34240 Date of Test: January 22, 1999 Issue Date: January 28, 1999 COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 9 of 48 Exhibit 6 CERTIFICATION OF ENGINEERING REPORT This report has been prepared by Communication Certification Laboratory to determine compliance of the device described below with the notification requirements of FCC Part 15, Subpart C Section 15.231. This report may be reproduced in full, partial reproduction may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. -Applicant:Salco Industries - Manufacturer:Salco Industries -Brand Name:SALCO -Model Number:SST -FCC ID:BZD-SST011198 On this 28 th day of January 1999, I, individually, and for Communication Certification Laboratory, certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge, and are made in good faith. Although NVLAP has recognized that the Communication Certification Laboratory EMC testing facilities are in good standing, NVLAP does not endorse the product described in this report. COMMUNICATION CERTIFICATION LABORATORY Checked by: Roger J. Midgley EMC Engineering Manager Tested by: Jeffrey L. Draney EMC Technician COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 10 of 48 Exhibit 6 SECTION 1.0 CLIENT INFORMATION 1.1 Client Information: Company Name: Salco Industries 263 Field End Road Sarasota, Florida 34240 Contact Name:Vincent Caputo Title:Director COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 11 of 48 Exhibit 6 SECTION 2.0 EQUIPMENT UNDER TEST (EUT) 2.1 Identification of EUT: Trade Name:SALCO Model Name or Number:SST Serial Number:N/A Options Fitted:N/A Country of Manufacture:U.S.A. 2.2 Description of EUT: The SST transmitter is designed to send a coded transmission to a SALCO model SR768 or model WZ8PD receiver. The SST transmitter provides two connections for monitoring the status of a normally open or normally closed alarm contact switch. The transmitter receives power from a 9-volt battery. 2.3 Modification Incorporated/Special Accessories on EUT: The following modifications were made to the SST by CCL during testing to comply with the specification. These modifications will be implemented during manufacturing. 1. R26 was tuned to 21.3 K Ω . Signature: Typed Name: Vincent Caputo Title: Director COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 12 of 48 Exhibit 6 SECTION 3.0 TEST SPECIFICATION, METHODS & PROCEDURES 3.1 Test Specification: Title:FCC PART 15, Subpart C (47 CFR 15). Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz. Purpose of Test: The tests were performed to demonstrate Initial compliance. 3.2 Methods & Procedures: 3.2.1 '' 15.231 (a) The provision of this section are restricted to periodic operation within the band 40.66-40.70 MHz and above 70 MHz. Except as Shown in paragraph (e) of this section, the intentional radiator is restricted to the transmission of a control signal such as those used with alarm systems, door openers, remote switches, etc. Radio control of toys in not permitted. Continuous transmissions, such as voice or video, and data transmissions are not permitted. The prohibition against data transmissions does not preclude the use of recognition codes. Those codes are used to identify the sensor that is activated or to identify the particular component as being part of the system. The following conditions shall be met to comply with the provisions for this periodic operation: (1) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. (2) A transmitter activated automatically shall cease transmission within 5 seconds after activation. (3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision transmission to determine system integrity of transmitters used in security or safety applications are allowed if the periodic rate of transmission does not exceed one transmission of not more than one second duration per hour for each transmitter. (4) Intentional radiators which are employed for radio control COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 13 of 48 Exhibit 6 purposes during emergencies involving fire, security, and safety of life, when activated to signal an alarm, may operated during the pendency of the alarm condition. (b) In addition to the provisions of ' 15.205, the field strength of emission from intentional radiators operated under this section shall not exceed the following: Fundamental frequency (MHz) Field strength of fundamental (microvolts/meter) Field strength of spurious emissions (microvolts/meter) 40.66 - 40.702,250225 70 –1301,250125 130 – 1741,250 to 3,750 **125 to 375 ** 174 – 2603,750375 260 – 4703,750 to 12,500 **375 to 1,250 ** Above 47012,5001,250 ** Linear interpolations (1) the above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the band edges. (2) Intentional radiators operating under the provisions of this section shall demonstrate compliance with the limits on the field strength of emissions, as shown in the above table, based on the average value of the measured emissions. As an alternative, compliance with the limits in the above table may be based on the use of measur…

Text truncated - open the document above for the full version.

Test Setup Photos

COMMUNICATION CERTIFICATION LABORATORYTEST REPORT: 73-6741 FCC ID: BZD-SST011198 Page 30 of 48 Exhibit 7 Exhibit 7: Test Set-Up Photographs

Contact Information

Applicant

Vincent Caputo
941 377-7717Fax: 941 379-9680

Technical Contact

Communication Certification LaboratoryRoger J Midgley
[email protected](801) 972-6146

1940 W. Alexander Street Β· Salt Lake City, Utah Β· United States

Test Firm

Nemko-CCL, IncThomas Jackson
[email protected]801-972-6146Fax: 801-972-8432

Technical Specifications

#Rule PartsFrequency RangePower Output
115C303.875 MHz - 303.875 MHz-

Other Applications from Salco Industries Inc

BZD0S2

Perimeter protection system must be professionally installed.

Mar 03, 1993

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
BZDST-PRO

Perimeter protection system must be professionally installed.

Mar 03, 1993

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
BZD8R7DX4000

DSC - Part 15 Security/Remote Control Transmitter

Mar 29, 1989

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
BZD8R7RDU-1

CYY - Communications Receiver used w/Pt 15 Transmitter

Nov 03, 1987

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
BZD8R7SR-768

CRR - Superregenerative Receiver

Jan 02, 1985

Equipment Class

CRR - Superregenerative Receiver