CM676A90343-0490343/90347 Digital Telemetry Transmitter

Spacelabs Healthcare, Inc.
90343/90347 Digital Telemetry Transmitter - FCC ID CM676A90343-04 - Spacelabs Healthcare, Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 13, 2000
Application Purpose
Original Equipment
Date of Application
Oct 03, 2000
Equipment Note
90343/90347 Digital Telemetry Transmitter
Frequency Range
602.00000000 - 620.00000000
Company
Spacelabs Healthcare, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗

Block Diagram

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗
↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Operational Description

↗

Schematics

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

EXHIBIT C – User Manual 1 FCC ID CM676A90343-04 1 ! •Based on features purchased, more or fewer keys may appear here than on your menu screens. 1Ultraview Digital Telemetry SCREEN FORMAT TONES MONITOR CONFIGURATION PRIVILEGED ACCESS. MONITOR SETUP CONTRASTBRIGHTNESS ADMIT CHANGE DATA DISCHARGE SCALED DISPLAY TIME/ DATE REMOTE ALARMS ALARM WATCH KEY TONE CLINICAL LEVEL: Select Parameter MONITOR CONFIGURATION ADMIT/DISCHARGE - Select Function (see Admit/Discharge) MONITOR SETUP - Select type of tone to change (see Alarms) MONITOR SETUP E C G CLEAR MEMORY SAVE MEMORY ECG - RELEARN 2nd LEAD ON OFF RATE SOURCE SWEEP SPEED QRS MONITOR PA C E D YES NO CONFIG TONE EXTENDED ADULT INFANT Select primary heart rate source ECG - CHANNEL FORMAT ECG - SETUP ECG - CONFIG ALARM LIMITS SIZESETUP LEAD SELECT CHANNEL FORMAT SUSPEND PROCESSING PRINT ECG MENU - (Multi-Lead) (MultiView TM II option with Arrhythmia and Review ON - used with 90343/90347 transmitter) REVIEW 2nd LEAD xx 1st LEAD xx ON OFF ECGARTUASPO2 Enable alternate rate source(s) ARR ON OFF UA ON OFF ART ON OFF SPO2 ON OFF TM SETUP RESTORE SETTINGS AUTO LEAD SWITCH ASSIGN TM BED PT RECORD YES NO LO BAT ON OFF SET TM CHAN ECG - TM SETUP Central only Bedside only Bedside monitors only select bed (or subnet, then bed) RELEARN SpO2 ON OFF NIBP ON OFF SpO2(IABP)(NEO) (RATE)(AVG) 90343 ECG ALM ON OFF ST LIMITS CH 1 ABN IN ROW=XX ABN PER MIN=XX ↑↓ ST LIMITS CH 2 ABN IN ROW=XX HI= XXX LO= XXX SPO2 ALM ON OFF ALM DELAY =XXs MSG ALM DELAY =XXs ↑ ↓ HI= XXX LO= XXX NIBP ALM ON OFF SYS MEAN ↑ ↓ HI= XXX LO= XXX DIA NIBP ACTIVE (NO CABLE) 90343 only SPO2 ALARM LIMITS NIBP ALARM LIMITS LIMITS 90347 (and 90343 with SpO 2 and NIBP turned OFF) 90343 select ECG 1 Select zone waveform select bed (or subnet, then bed) RECORDER DESTINATION ECG - LEAD SELECT ON OFF SINGLE LEAD ALARM only ECG ALARM CLOCK ON OFF ACTIVATE SCREEN SAVER PRESELECTED RECORDINGS UNITS OF MEASURE USER ACCESS ENABLE ALARM SETUP ADMIT/ DISCHARGE Directory of Keys - UCW and Ultraview 1700 2 Contents 1 Ultraview Digital Telemetry General Telemetry Overview...............................................................................3 Cleaning .................................................................................................................9 Assigning a Telemetry Channel .............................................................................9 Tuning a Receiver for a Bedside............................................................................9 Entering Patient Information.................................................................................10 Discharging a Patient ...........................................................................................10 Acknowledging Signal Loss .................................................................................11 Setting Battery Status Alarms ..............................................................................11 Controlling Patient-Initiated Recordings...............................................................11 Telemetry Alarm Message Summary...................................................................11 ECG Overview ....................................................................................................12 Setting Up ECG Monitoring..................................................................................12 Display Detail .......................................................................................................14 Monitoring Paced ECG Patients ..........................................................................15 Restoring Default Settings ...................................................................................16 Changing the Display Resolution .........................................................................16 Selecting Options for Lead Display ......................................................................16 ECG Alarm Message Summary ...........................................................................17 ECG Troubleshooting Guide ................................................................................20 SpO2 Overview (90343 only) .............................................................................22 Setting Up SpO2 Monitoring ................................................................................22 Ensuring Accurate Monitoring ..............................................................................24 Setting or Adjusting Alarm Limits .........................................................................24 Setting SpO2 Data Averaging Period and Sampling Interval...............................26 Viewing Pulse Rate ..............................................................................................27 SpO2 with Intra-Aortic Balloon Pumps.................................................................27 Using SpO2 with Neonates ..................................................................................28 SpO2 Alarm Message Summary..........................................................................28 SpO2 Troubleshooting Guide...............................................................................30 NIBP Overview (90343 only)..............................................................................32 Setting Up NIBP Monitoring .................................................................................32 Setting Up the ABP Monitor .................................................................................33 Setting or Adjusting Alarm Limits .........................................................................37 Displaying New or Previous Readings .................................................................38 NIBP Alarm Message Summary ..........................................................................39 NIBP Troubleshooting Guide ...............................................................................42 Alarm Message Summa…

Text truncated - open the document above for the full version.

Users Manual

EXHIBIT G – User Manual 2 FCC ID CM676A90343-04 SPECIFICATIONS PARAMETER CHARACTERISTICS ECG Maximum Input — ±4 mV ( ±10%) DC Offset — Up to ±300 mV, with no more than 2% signal amplitude degradation Overdrive Recovery Time — < 1 second circuit settling time with offset voltage < 500 mV Noise — < 30 μV p-p, refered to input (rti), at 30 Hz bandwidth CMRR — > 85 dB (monitor mode) QRS Detection — Detects QRS complexes with amplitudes of 0.2 to 4.0 mV (adult) or 0.15 to 4.0 mV (neonatal) Defibrillator Protection — Meets IEC 60601-2-27, AAMI EC-13 Resolution — 2.5 μV per LSB, rti Input Impedance — > 10 MΩ minimum differential at 10 Hz Gain Accuracy — ±5 % Pacer Rejection — Baseline shift < 0.2 mV (measured at ECG x 1,000 output) Pacer Detection — Detects pacer pulses of ±2 mV to ±700 mV with pulse widths of 0.2 to 2 msec and rise times 10% of width not to exceed 100 μsec Signal Bandwidth — 0.05 to 30 Hz ±10% (-3 dB) Sample Rate — 120 samples per second Ultraview ™ Digital Telemetry 90343, 90347, 90478-Q,-T,-V, 90479-A 602-620 MHz frequency operation, including 608-614 MHz Wireless Medical Telemetry Service (WMTS) band Touchscreen control of all module functions and compatible with all Ultraview Care Network ™ monitors Multi-parameter telemetry monitoring ECG, SpO 2 , and NIBP (optional) Lightweight, water resistant transmitters Diversity antenna system Tunable modular receiver Modular receiver converts bedside monitors to telemetry operation Multi-lead ECG with ST segment analysis option; comprehensive arrhythmia and ST trending Module Configuration Manager enables the hospital to customize the receiver’s ECG patient monitoring functions to specific patient populations, clinical protocols, or operating preferences Graded alarm functions enables the hospital to define high, medium, or low alarm tones according to critical, warning, or advisory event severity Diversity Antenna System 90217 ABP Monitor 90478 Modular Receiver 90479-A Modular Receiver Housing 90343 Digital Telemetry Multi-parameter Transmitter 90347 Digital Telemetry ECG Transmitter (options Q, T, and V) mmHg mmHg model 90217 • Install three , fresh “ AA ” cells ( 1.5 Alkaline or NiCad). Obser ve polar ities . SPECIFICATIONS Ultraview Digital Telemetry 90343, 90347, 90478-Q, 90478-T, 90478-V, 90479-A SpO 2 SpO 2 Sensor Interface — Red LED drive (max): 175 mA peak at 10% duty cycle IR LED drive (max): 105 mA peak at 10% duty cycle SpO 2 Measurement Method — Functional saturation (oxygen saturation of functional hemoglobin) SpO 2 Measurement Mode — Continuous, episodic (2 minutes, 5 minutes, and 30 minutes) sampling intervals; factory default setting is continuous ST Segment Analysis Resolution — 0.08 mm Range — ±9 mm (1 mV = 10 mm) Leads — ST Segment Analysis continously performed on up to seven leads Alarms — Single lead or multiple leads; individual leads can be deselected Trends — Up to 24 hours of trend data can be displayed in 1.5-, 3-, 6-, 12-, or 24-hour time tracks DISPLAY CHARACTERISTICS ECG Display Heart Rate Range — 30 to 300 bpm; heart rates > 300 bpm are displayed as “+++” Heart Rate Alarm Limits — High: 5 to 300 bpm, Low: 0 to 200 bpm; alarms automatically enabled over a range of 40 (adult) or 100 (neonatal) to 300 bpm Accuracy — ±1% or ±2 beats per minute (whichever is greater) Numeric Update Rate — Every 3 seconds or immediately at the onset of an alarm Trace Sweep Speeds — 50, 25, 12.5 mm/sec SpO 2 Display Measurement Range — 30 to 100% O 2 Saturation Saturation Accuracy: — Sensor Dependent Saturation Resolution — ±1% Pulse Rate Range — 30 to 250 bpm Pulse Rate Resolution — 1 bpm Alarms — High and low saturation values; factory default limits are: high 100%; low 85% High range: 31% – 100% Low range: 30% – 99% Numeric Update Rate — Every 2 seconds for continuous SpO 2 readings NIBP Display (Refer to specifications for the 90217 ABP Monitor) Measurement Range (adult only) — Systolic: 8.0 – 35.0 kPa (60 – 260 mmHg) Diastolic: 9.0 – 27.0 kPa (30 – 200 mmHg) Mean: 5.3 – 31.0 kPa (40 – 230 mmHg) Pressure Accuracy — ±2% or ±3 mmHg (whichever is greater) Resolution — 1 mmHg Time Between Readings — selectable, from 6 to 120 minutes Alarms — High and low alarms for all measured parameters High range: 8.0 – 35.0 kPa (60 – 260 mmHg) Low range: 4.0 – 27.0 kPa (30 – 200 mmHg) TRANSMITTERS (90343, 90347) ECG Transmission — View 2 of 7 available leads from four vectors (90343, 90347) synchronized RF digital signal Electrode Configuration — Individually replaceable DIN standard safety lead wires Multi-parameter Transmission (90343) — SpO 2 (saturation, SpO 2 sensor status, pulse rate) and optional NIBP (systolic, diastolic, mean pressure, measurement time, alarm conditions) with the model 90217 ABP monitor Additional Data Transmitted — Patient record, low battery indicator, pacer flag, patient ID code, and electrode connection status Output Power — 4 mW ERP, typical Spectral Efficiency — 0.11 bps/Hz External Indicator — Yellow LED flashes when battery level is low Battery — 9 V battery; refer to Table 1 for battery life expectancy Frequency Band Option — -04:602-608 MHz -05:608-614 MHz -06:614-620 MHz TRANSMITTER PHYSICAL DIMENSIONS 90343 (Multi-Parameter) Height:5.25 in(13.3 cm) Width:2.85 in(7.2 cm) Depth:1.18 in(2.9 cm) Weight (w/out battery): 8.5 oz (241.0 gm) 90347 (ECG-only) Height:5.25 in(13.3 cm) Width:2.85 in(7.2 cm) Depth:0.98 in(2.5 cm) Weight (w/out battery): 6.78 oz (192.7 gm) SPECIFICATIONS Ultraview Digital Telemetry 90343, 90347, 90478-Q, 90478-T, 90478-V, 90479-A MODULAR RECEIVER (90478 Options Q, T, and V) Module Configuration Manager capability (refer to the Module Configuration Manager chapter of the Ultraview Care Network Operations Manual for complete feature specifications) Trends — (with appropriate mainframe option) 24 hours of trended data can be displayed in 1.5-, 3-, 6-, 12-, or 24-hour segments; data is stored in 1-minute resolution High Level Analog Output — ECG 1: Used for defibrillator syn…

Text truncated - open the document above for the full version.

Attestation Statements

EXHIBIT P – Equipment Modifications Attestation Letter FCC ID CM676A90343-04

Block Diagram

EXHIBIT H – Frequency Block Diagram FCC ID CM676A90343-04

Block Diagram

EXHIBIT O – System Block Diagram FCC ID CM676A90343-04

Cover Letter(s)

EXHIBIT A – Agent Authorization Letter FCC ID CM676A90343-04

Cover Letter(s)

EXHIBIT Q – Anti-Drug Letter FCC ID CM676A90343-04

Cover Letter(s)

Exhibits for the FCC application for 90343/90347 Digital Telemetry Transmitter FCC ID: CM676A90343-04 Exhibit Description File Name Exhibit A Agent Authorization Letter Agent Authorization Letter.pdf Exhibit B Technical Report Technical Report.pdf Exhibit C User Manual 1 User Manual 1.pdf Exhibit D FCC ID Label FCC ID Label.pdf Exhibit E Spurious Radiated Emissions Test Data Spurious Radiated Emissions.pdf Exhibit F Schematics Schematics.pdf Exhibit G User Manual 2 User Manual 2.pdf Exhibit H Frequency Block Diagram Frequency Block Diagram.pdf Exhibit I External Photos – 90343 External Photos-90343.pdf Exhibit J External Photos – 90347 External Photos-90347.pdf Exhibit K Internal Photos – 90343 Internal Photos – 90343.pdf Exhibit L Internal Photos - 90347 Internal Photos – 90347.pdf Exhibit M Test Setup Photos Test Setup Photos.pdf Exhibit N Patient Lead Photos Patient Lead Photos.pdf Exhibit O System Block Diagram System Block Diagram.pdf Exhibit P Equipment Modifications Letter Equipment Modifications Attestation Letter.pdf Exhibit Q Anti-Drug Letter Anti-Drug Letter.pdf Exhibit R Operational Description Operational Description.pdf Exhibit S Exhibit T

Cover Letter(s)

NORTHWEST EMC, INC. 22975 NW Evergreen Parkway, Suite 400 Hillsboro, OR 97124 October 4, 2000 Dear Application Examiner: On behalf of Spacelabs Medical, Northwest EMC, Inc is submitting this application for the certification of Model 90343/90347 Digital Telemetry Transmitter, FCC ID: CM676A90343-04. It is a biomedical telemetry transmitter operating in the 602-620 MHz band. It utilizes frequency shift keying modulation and operates on a 50 kHz system channel spacing. Concurrent with the filing of this application, a second application (FCC ID: CM67A90343-WMTS) for this same device has been filed for authorization under the Wireless Medical Telemetry Service (47 CFR 95.1115). The technical report and exhibits included with this application demonstrate compliance with FCC rules 47 CFR 15.242. To facilitate the review process, an index of exhibits has been provided (see file “Index of exhibits.pdf”). Please note that the field strength data of the fundamental emission is included in the same file as the spurious radiated emissions data (see file “Spurious Radiated Emissions.pdf”). Your efforts in reviewing this application are greatly appreciated. Best regards, Greg Kiemel Northwest EMC, Inc.

External Photos

EXHIBIT I – External Photos - 90343 FCC ID CM676A90343-04

External Photos

EXHIBIT L – Internal Photos - 90347 FCC ID CM676A90343-04

External Photos

EXHIBIT N – Patient Lead Photos FCC ID CM676A90343-04 Patient RA ECG Lead acts as the Antenna Snap fastener for the ECG Pad at the patient end of antenna DIN-Safety molded rubber plug at the Transmitter End of antenna Shorting Board Shorting Board

ID Label/Location Info

EXHIBIT D – FCC ID Label FCC ID CM676A90343-04 FCC ID: CM676A90343-04 Manufactured by Spacelabs Medical, Inc. Redmond, WA DIGITAL TELEMETRY MULTI-PARAMETER TRANSMITTER 90343 Made In USA 1-800-522-7025425-882-3700 334-2157-02 FCC ID: CM676A90343-04 Manufactured by Spacelabs Medical, Inc. Redmond, WA DIGITAL TELEMETRY ECG TRANSMITTER 90347 Made In USA 1-800-522-7025425-882-3700 334-2305-02 Location of FCC ID Label

Internal Photos

EXHIBIT K – Internal Photos - 90343 FCC ID CM676A90343-04

Internal Photos

EXHIBIT L – Internal Photos - 90347 FCC ID CM676A90343-04

Operational Description

EXHIBIT R – Operational Description FCC ID CM676A90343-04 Operational Description The model 90343 consists of three major printed circuit board assemblies (PCBAs). The ECG PCBA (part number 670-0285-02) acquires the patient’s ECG via skin electrodes that are interconnected to this PCBA through 5 lead wires. The ECG analog signal is conditioned and band-limited, and then routed to the RF PCBA (part numbers 670-0969-00 through 670-0972-00). The Model 90343 also includes a PCBA for acquiring and computing the patient’s blood oxygen saturation value (SpO2). This SpO2 PCBA (part number 670-0916-00) interfaces with selected standard pulse oximetry sensors which emit red and infrared (Ir) light through a patient tissue bed that includes arterial blood flow. These light sources are detected by photodiodes embedded in the same sensor. The ration of the amount of absorbed red light to the amount of absorbed Ir light is used to compute the patient’s blood oxygen saturation value and arterial pulse value. This PCBA is also used to communicate with a separate SMI patient monitoring product, the Model 90217 Ambulatory Blood Pressure (ABP) Monitor. The Model 90217 ABP monitor can be programmed to episodically or on demand, measure the patient’s blood pressure non-invasively. This non-invasive blood pressure (NIBP) value is stored in the Model 90217. This NIBP value can also be transferred to the Model 90343 via a communications port on each product. The Model 90347 is identical to the Model 90343, except it does not include the SpO2 PCBA. All other PCBAs area the same between both products. The diagnostics software executes on the CPU (Motorola 68CK16Z4) of the Transmitter’s SpO2 printed circuit board assembly (PCBA) at a clock rate of 4.194 MHz via the internal Phase Locked Loop (PLL) on the CPU. The clock to the CPU is a standard watch crystal (32.768 kHz). A pulse width modulator (PWM) is used to drive the SpO2 red and infrared diodes at 2.048 Hz rate. The CPU buses used for drive, gain, baseband signal output (numerical SpO2 and NIBP data), and SpO2 sampling operate at 2.097 MHz. These buses control the digital-to-analog converters (DACs) for drive current, gain, baseband signal output to the RF modulator. With simulated ECG waveform data inputted into the ECG PCBA, all functions are activated in the diagnostics software and represent a worst case data scenario. Under normal operation, the analog-to-digital converter (A/D) and drive circuitry will power down momentarily to conserve power-this does not occur in the test software.

Schematics

EXHIBIT F – Schematics FCC ID CM676A90343-04

Test Report

EXHIBIT B – Technical Report FCC ID CM676A90343-04 Measurement/Technical Report Spacelabs Medical Model 90343/90347 Digital Telemetry Transmitter FCC ID: CM676A90343-04 August 23, 2000 This report concerns (check one): Original Grant X Class II Change____ Equipment Type: Part 15 Low Power Communication Device Transmitter Rule Part: 47 CFR 15.242 Notes: Biomedical Telemetry Transmitter Deferred grant requested per 47 CFR 0.457 (d)(1)(ii)? Yes_____ no__X__ If yes, defer until: ______N/A______ Date Spacelabs Medical agrees to notify the Commission by: ______N/A______ Date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37: yes_____ no__X__ If no, assumed Part 15, Subpart C for intentional radiators – new 47 CFR [10-1-92] provision. Report prepared by: Northwest EMC, Inc. 22975 NW Evergreen Pkwy. Ste 400 Hillsboro, OR 97124 (503) 844-4066 Fax: (503) 844-3826 Report No. SPAC0246.1 FCC ID: CM676A90343-04 Northwest EMC, Inc. Report No. SPAC0246.1 Page 2 Table of Contents Section Description Page 1.0 General Information 3 1.1 Product Description 3 1.2 Related Submittals/Grants 5 1.3 Tested System Details 5 Figure 1 Configuration of Tested System 6 1.4 Test Methodology 7 1.5 Test Facility 7 2.0 System Test Configuration 8 2.1 Justification 8 2.2 EUT Exercise Software 8 2.3 Special Accessories 8 2.4 Equipment Modifications 8 3.0 Antenna Information 9 4.0 RF Exposure Compliance Requirements 9 5.0 AC Powerline Conducted Emissions Data 10 6.0 Spurious Radiated Emissions Data 11 7.0 Field Strength Calculations 12 7.1 Measurement Bandwidths 12 8.0 Measurement Equipment 13 FCC ID: CM676A90343-04 Northwest EMC, Inc. Report No. SPAC0246.1 Page 3 1.0 General Information 1.1 Product Description Manufactured By...................................................................................................Spacelabs Medical Address........................................................................15220 NE 40 th Street, Redmond, WA 98073 Test Requested By: .................................................................................................... Steve Cantwell Model ...................................................................Model 90343/90347 Digital Telemetry Transmitter FCC ID...................................................................................................................CM676A90343-04 Serial Number(s) .................................................................. 343-001201, 343-001239, 347-001337 Date of Test ..............................................................................................................August 23, 2000 Job Number ................................................................................................................... SPAC0246.1 Prepared By: Vicki Albertson, Technical Report and Documentation Manager Technical Review By: Approved By: Greg Kiemel, Director of Engineering Dean Ghizzone, President FCC ID: CM676A90343-04 Northwest EMC, Inc. Report No. SPAC0246.1 Page 4 1.1 Product Description - continued This application is being submitted in support of an equipment authorization request for the Spacelabs Medical Model 90343 and 90347 Enhanced Digital Telemetry Transmitter (FCC ID CM676A90343-04), in accordance with Part 15.242 of the Federal Communication Commission’s Rules and Regulations. The Model 90343 is a multi-parameter biomedical telemetry transmitter that is used for the transmission of a patient’s vital signs data, including the electrocardiogram (ECG), blood oxygen saturation (SpO2), and non-invasive blood pressure (NIBP). This physiological data is encoded in a digital format and used to FSK-modulate a crystal controlled, RF carrier. This device is intended for use within the confines of medical facilities. It is not intended for off-premise vehicular use. The Model 90347 transmitter is a lesser version of the 90343. It utilizes the same RF and ECG circuit boards, but lacks the SpO2 circuit board and the NIBP interface, making it a singular parameter (ECG only) device. This battery (9 volt alkaline type) powered UHF transmitter is worn by the patient. It operates on a 50 kHz system channel spacing. It utilizes unused UHF television channels from 602 to 620 MHz in accordance with 47 CFR 15.242. The RF signal from this transmitter is radiated on one of the patient ECG lead wires, which, at a 3 meter distance, produces a field strength of approximately 64 millivolts per meter. . The allowable field strength for this class of device as authorized under the FCC Rules is 200 millivolts per meter at 3 meters. This transmitter’s RF design is based on Spacelabs Medical’s Model 90340 UHF telemetry transmitter (FCC ID: CM676A90340), and has had the RF passive components sized for the higher UHF operation. The transmitted RF signal is received by a Model 90478 digital telemetry receiver. The receiver down-converts and demodulates the vital signs information to base band. Whereby they are processed for display in any of the Spacelabs Medical (SMI) Patient Care Management System (PCMS™) patient monitors. Clocks/Oscillators Frequencies RF BOARD (90343/90347) • RF Carrier: 602 MHz to 620 MHz • Fixed Crystal Oscillator: 150.5 to 155.0 MHz • Watch Crystal 32 kHz • Frame Rate 120 Hz • Super Frame 2.5 Hz • Low battery warning lamp 0.5 Hz SpO2 Board (90343 only) • Processor crystal 32 kHz • Processor clock 4.194 MHz • A to D converter 2.45 MHz • SpO2 drive 1.024 kHz • SpO2 sample rate 1.048 MHz FCC ID: CM676A90343-04 Northwest EMC, Inc. Report No. SPAC0246.1 Page 5 1.2 Related Submittals/Grants This product belongs to the same family of telemetry transmitters as the FCC ID CM67690340 and CM690343-05. The differences lie in the operating frequency range and increase of the output power to overcome a predicted increased path loss. 1.3 Tested System Details EUT and Peripherals Item FCC ID Description and Serial No. EUT CM676A90343-04 Spacelabs Medical Mode…

Text truncated - open the document above for the full version.

Test Report

EXHIBIT E – Spurious Radiated Emissions Data FCC ID CM676A90343-04 Rev 3.3 10/09/99 Comments: Frequency Meter ReadingDetector Antenna Factor Antenna PolarityPreamp GainCable Loss Table Azimuth Antenna Height Adjusted LevelSpec. LimitMargin (MHz)(dBuV)(dB/m)(dB)(dB)(degrees)(meters)(dBuV/m)(dBuV/m)(dB) 301.02058.2QP18.1HBLG34.83.550.01.345.046.0-1.0 301.00352.0QP15.1VLPA34.83.590.01.435.846.0-10.2 602.064106.0QP19.0HLPA34.75.460.01.695.7106.0-10.3 903.04139.7QP22.8HLPA34.26.360.01.034.646.0-11.4 602.038104.6QP19.0VLPA34.75.470.01.794.3106.0-11.7 903.03739.1QP22.8VLPA34.26.395.01.034.046.0-12.0 FCC Part 15.242c (3 Meter Limit) Northwest EMC, Inc., Radiated and Conducted Emissions Data Sheets EUT:Serial Number:Job Number:Date: Manufacturer:Test Engineer:Job Site: SU02 Customer Reference Number:Software:Power: Application Specific Temperature (°C):% Humidity: Test System See system details Test Equipment APAABDALHADDAAIAQB 08/23/00 Jim Theabolt 2257 9VDC, patient leads shorted, R7 = 4.99K ohm. 90347 configuration343-001201 (602) Spacelabs SPAC0246 0.0 20.0 40.0 60.0 80.0 100.0 120.0 101001000 Frequency (MHz) dBuV/meter Rev 3.3 10/09/99 Comments: Frequency Meter ReadingDetector Antenna Factor Antenna PolarityPreamp GainCable Loss Table Azimuth Antenna Height Adjusted LevelSpec. LimitMargin (MHz)(dBuV)(dB/m)(dB)(dB)(degrees)(meters)(dBuV/m)(dBuV/m)(dB) 309.97558.4QP18.4HBLG34.83.6310.01.145.646.0-0.4 619.949106.1QP19.2HLPA34.75.5290.01.396.1106.0-9.9 929.91240.2PK23.2VLPA34.06.5275.01.035.946.0-10.1 619.952105.1QP19.2VLPA34.75.5240.01.395.1106.0-10.9 309.95951.1QP14.9VLPA34.83.6260.01.234.846.0-11.2 929.91138.9PK23.2HLPA34.06.5280.01.034.646.0-11.4 FCC Part 15.242c (3 Meter Limit) Northwest EMC, Inc., Radiated and Conducted Emissions Data Sheets EUT:Serial Number:Job Number:Date: Manufacturer:Test Engineer:Job Site: SU02 Customer Reference Number:Software:Power: Application Specific Temperature (°C):% Humidity: Test System See system details Test Equipment APAABDALHADDAAIAQB 08/23/00 Jim Theabolt 2254 9VDC, patient leads shorted 90343343-001239 (620) Spacelabs SPAC0246 0.0 20.0 40.0 60.0 80.0 100.0 120.0 101001000 Frequency (MHz) dBuV/meter Rev 3.3 10/09/99 Comments: Frequency Meter ReadingDetector Antenna Factor Antenna PolarityPreamp GainCable Loss Table Azimuth Antenna Height Adjusted LevelSpec. LimitMargin (MHz)(dBuV)(dB/m)(dB)(dB)(degrees)(meters)(dBuV/m)(dBuV/m)(dB) 305.49654.6QP15.0HLPA34.83.5220.01.038.346.0-7.7 611.029104.4QP19.1HLPA34.75.4240.01.294.2106.0-11.8 611.03098.5QP19.1VLPA34.75.4285.01.188.3106.0-17.7 916.54832.3QP23.0VLPA34.16.460.01.227.646.0-18.4 916.54832.2QP23.0HLPA34.16.430.01.027.546.0-18.5 305.49843.5QP15.0VLPA34.83.5270.01.127.246.0-18.8 FCC Part 15.242c (3 Meter Limit) Northwest EMC, Inc., Radiated and Conducted Emissions Data Sheets EUT:Serial Number:Job Number:Date: Manufacturer:Test Engineer:Job Site: SU02 Customer Reference Number:Software:Power: Application Specific Temperature (°C):% Humidity: Test System See system details Test Equipment APAABDALHADDAAIAQB 08/23/00 Jim Theabolt 2254 9VDC, patient leads shorted 90347 Configuration347-001337 (611) Spacelabs SPAC0246 0.0 20.0 40.0 60.0 80.0 100.0 120.0 101001000 Frequency (MHz) dBuV/meter Rev 3.3 10/09/99 Comments: Frequency Meter ReadingDetector Antenna Factor Antenna PolarityPreamp GainCable Loss Table Azimuth Antenna Height Adjusted LevelSpec. LimitMargin (MHz)(dBuV)(dB/m)(dB)(dB)(degrees)(meters)(dBuV/m)(dBuV/m)(dB) 300.99957.4QP15.1HLPA34.83.535.01.141.246.0-4.8 602.040105.2QP19.0HLPA34.75.465.01.294.9106.0-11.1 301.00847.2QP15.1VLPA34.83.575.01.231.046.0-15.0 903.05433.5QP22.8VLPA34.26.395.01.328.446.0-17.6 903.05432.9QP22.8HLPA34.26.3175.01.127.846.0-18.2 602.07497.6QP19.0VLPA34.75.490.01.387.3106.0-18.7 602.03893.6QP19.0HLPA34.75.4250.01.183.3106.0-22.7 602.03891.8QP19.0VLPA34.75.4240.01.381.5106.0-24.5 FCC Part 15.242c (3 Meter Limit) Northwest EMC, Inc., Radiated and Conducted Emissions Data Sheets EUT:Serial Number:Job Number:Date: Manufacturer:Test Engineer:Job Site: SU02 Customer Reference Number:Software:Power: Application Specific Temperature (°C):% Humidity: Test System See system details Test Equipment APAABDALHADDAAIAQB 08/23/00 Jim Theabolt 2250 9VDC, patient leads shorted, R7 = 6.98K ohm resistor. 90343 Configuration343-001201 (602) Spacelabs SPAC0246 0.0 20.0 40.0 60.0 80.0 100.0 120.0 101001000 Frequency (MHz) dBuV/meter Rev 3.3 10/09/99 Comments: Frequency Meter ReadingDetector Antenna Factor Antenna PolarityPreamp GainCable Loss Table Azimuth Antenna Height Adjusted LevelSpec. LimitMargin (MHz)(dBuV)(dB/m)(dB)(dB)(degrees)(meters)(dBuV/m)(dBuV/m)(dB) 305.50154.3QP15.0HLPA34.83.535.01.138.046.0-8.0 611.035104.4QP19.1HLPA34.75.460.01.194.2106.0-11.8 611.035104.1QP19.1VLPA34.75.4270.01.093.9106.0-12.1 916.54033.6QP23.0VLPA34.16.4240.01.428.946.0-17.1 916.54032.5QP23.0HLPA34.16.4240.01.027.846.0-18.2 611.07097.3QP19.1HLPA34.75.4215.01.387.1106.0-18.9 305.51742.5QP15.0VLPA34.83.5215.01.226.246.0-19.8 611.01694.1QP19.1VLPA34.75.4265.01.283.9106.0-22.1 FCC Part 15.242c (3 Meter Limit) Northwest EMC, Inc., Radiated and Conducted Emissions Data Sheets EUT:Serial Number:Job Number:Date: Manufacturer:Test Engineer:Job Site: SU02 Customer Reference Number:Software:Power: Application Specific Temperature (°C):% Humidity: Test System See system details Test Equipment APAABDALHADDAAIAQB 08/23/00 Jim Theabolt 2250 9VDC, patient leads shorted 90343 Configuration347-001337 (611) Spacelabs SPAC0246 0.0 20.0 40.0 60.0 80.0 100.0 120.0 101001000 Frequency (MHz) dBuV/meter Rev 3.3 10/09/99 Comments: Frequency Meter ReadingDetector Antenna Factor Antenna PolarityPreamp GainCable Loss Table Azimuth Antenna Height Adjusted LevelSpec. LimitMargin (MHz)(dBuV)(dB/m)(dB)(dB)(degrees)(meters)(dBuV/m)(dBuV/m)(dB) 309.97559.5QP14.9HLPA34.83.6320.01…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Steve Cantwell(Product Safety Engineer)
[email protected]425-363-5728Fax: 425-363-5754

Technical Contact

Northwest EMC, Inc.Greg V Kiemel
[email protected]503-844-4066

22975 NW Evergreen Parkway · Hillsoboro, Oregon · United States

Non-Technical Contact

Northwest EMC, Inc.Vicki L Albertson
[email protected]503-844-4066

Test Firm

Northwest EMC, Inc.Greg Kiemel
[email protected]503-844-4066Fax: 503-844-3826

Technical Specifications

#Rule PartsFrequency RangePower Output
115C602 MHz - 620 MHz-

Other Applications from Spacelabs Healthcare, Inc.

96281-A09N, 96281-A09W, 96281-B09N, 96281-B09W, 96281-C09W - FCC ID CM6-670-1632-1400 - Spacelabs Healthcare, Inc.
CM6-670-1632-1400

96281-A09N, 96281-A09W, 96281-B09N, 96281-B09W, 96281-C09W

May 20, 2014

Equipment Class

TNT - Licensed Non-Broadcast Transmitter Worn on Body
010-1927-00 - FCC ID CM6-WT12 - Spacelabs Healthcare, Inc.
CM6-WT12

010-1927-00

Jul 24, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
96281-A05N, 96281-A05W, 96281-B05N, 96281-B05W, 96281-C05W - FCC ID CM6-670-1187-608 - Spacelabs Healthcare, Inc.
CM6-670-1187-608

96281-A05N, 96281-A05W, 96281-B05N, 96281-B05W, 96281-C05W

Jul 16, 2012

Equipment Class

TNT - Licensed Non-Broadcast Transmitter Worn on Body
91343-09/91347-09 - FCC ID CM676A91343-1400 - Spacelabs Healthcare, Inc.
CM676A91343-1400

91343-09/91347-09

Sep 06, 2006

Equipment Class

TNT - Licensed Non-Broadcast Transmitter Worn on Body
91341-09 - FCC ID CM676A91341-1400 - Spacelabs Healthcare, Inc.
CM676A91341-1400

91341-09

Oct 27, 2003

Equipment Class

TNT - Licensed Non-Broadcast Transmitter Worn on Body