FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. DONGGUAN QIANFENG ELECTRONICS CO.,LTD./
  3. COXADAMIHKT31UB

COXADAMIHKT31UBINDUCTION COOK TOP

DONGGUAN QIANFENG ELECTRONICS CO.,LTD.
INDUCTION COOK TOP - FCC ID COXADAMIHKT31UB - DONGGUAN QIANFENG ELECTRONICS CO.,LTD.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Nov 02, 2014
Application Purpose
Original Equipment
Date of Application
Nov 02, 2014
Equipment Note
INDUCTION COOK TOP
Frequency Range
0.01900000 - 0.02800000
Company
DONGGUAN QIANFENG ELECTRONICS CO.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 IMPORTANT SAFEGUARDS Basic safety precautions should always be followed when using electrical appliances, including the fol lowing: 1. Important: Read all instructions carefully befor e first use. 2. Do not touch hot surface. Use handles or knobs. 3. Use only a level, dry, and heat-resistant surfac e. 4. To protect against electrical shock, do not imme rse the cord, plug or the appliance itself in water or any other liquid. 5. Close supervision is necessary when the applianc e is used by or near children. 6. Unplug from the outlet when not in use and befor e cleaning. Allow unit to cool completely before pu tting on or taking off parts and before cleaning. 7. If a wet sponge or cloth is used to wipe spills on a hot cooking area, exercise caution to avoid st eam burns. Some cleaners can produce noxious fumes if applied to a hot surface. 8. Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner. Contact IRIS USA, Inc customer service for examinat ion, repair or adjustment. 9. The use of accessory attachments not recommended by IRIS USA, Inc may result in fire, electrical sh ock or injury. 10. Do not use outdoors. 11. Do not allow the power cord to touch hot surfac es or to hang over the edge of the counter or table . 12. Do not place on or near a hot burner or in a he ated oven. 13. Do not use the appliance for other than its int ended use. 14. Extreme caution must be used when moving the ap pliance containing hot oil or other hot liquids. 15. To disconnect, turn any controls to "Off" or “S tand by”, then remove plug from the outlet. 16. Use only with a 120V AC power outlet. 17. Always unplug from the base of the wall outelt. Never pull on the cord. 18. Do not cook on the induction cooktop if any cra cks in the glass surface occur. Cleaning solutions or spills may leak through crack s and create a risk of electric shock. Contact IRIS USA, Inc customer service is this occurs. 19. If the cooktop surface is cracked, turn off the appliance immediately to avoid the possibility of electric shock and contact IRIS USA, Inc customer s ervice. 20. Metallic objets such as knives, forks, spoons a nd lids should not be placed on the cook top to avo id heating. 21. This appliance is not intended to be operated w ith an external timer or separate control system. 22. Changes or modifications not expressly approved by IRIS USA, Inc may void the user's authority to operate this appliance. 23. Any other servicing should be performed by IRIS USA, Inc or an authorized service representative. 24. NOTE: This equipment has been tested and found to comply with the limits for a consumer ISM equipm ent, pursuant to Part 18 of the FCC Rules. These li mits are designed to provide reasonable protection against h armful interference in a residential installation. This equipment generates, uses and can radiate radi o frequent energy and, if not installed and used in accordance with t he instructions, may cause harmful interference to radio communications. However, there is no guarante e that interference will not occur in a particular installation. 25. If this equipment does cause harmful interferen ce to radio or television reception, which can be d etermined by turning the equipmentoff and on, the u ser is encouraged to try to correct the interference by one or more of t he following measures: 1) Reoriant or relocate the receiving antenna. 2) Increase the separation between the equipment an d receiver. 3) Connect the equipment into an oulet on a circuit different from that to which the receiver is conne cted. 4) Consult IRIS USA, Inc customer service or an exp erienced radio/TV technician for further help. 26. This equipment has been tested and found to com ply with Part 18 of the FCC Rules. Operation is sub ject to the following two conditions: (1) This devi ce may not cause harmful interference, and (2) this device must acce pt any interference received, including interferenc e that may cause undesired operation. 27. Although current studies have shown induction c ooktops pose no health problems, persons with pacem akers or similar medical devices should use caution and keep a minimum of at least two feet from the induction coo ktop when using as to avoid possible interference f rom the magnetic field. It's advised to check with a doctor regarding your particular situation before first use. SAVE THESE INSTRUCTIONS 2 IMPORTANT SAFEGUARDS Short Cord Instructions 1. A short power-supply cord is provided to reduce the risks resulting from becoming entangled in or t ripping over a longer cord. 2. Longer extension cords are available and may be used if care is exercised in their use. 3. If a longer extension cord is used: a. The marked electrical rating of the extension co rd should be at least as great as the electrical ra ting of the appliance. b. The longer cord should be arranged so that it wil not drape over the counter top or t abletop where it can be pulled by children or tripp ed over unintentionally. DO NOT DRAPE CORD. KEEP AWAY FROM CHILDREN. Polarized Plug This appliance has a polarized plug (one blade is w ider than the other); follow the instructions below : To reduce the risk of electric shock, this plug is intended to fit into a polarized outlet only one wa y. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician . Do not attempt to modify the plug in any way. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similar ly qualified person in order to avoid a hazard. THIS APPLIANCE IS FOR HOUSEHOLD USE ONLY. 3 PARTS INDENTIFICATION Control Panel

Cover Letter(s)

Dongguan qianfeng electronics co., ltd. Authority to Act as Agent Date: _2014/10/28__ American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: _____ SGS-CSTC Standards Technical Services Co., Ltd._____ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b) , to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: _____(Typically 8 – 12 months)_____ By: __________________________ ____Adam Wen____________________ (Signature 1 ) (Print name) Title: ___Marketing Manager_______________________ On behalf of: _____Dongguan qianfeng electronics co., ltd._____ (Company Name) Telephone: __0769-88480078______________ 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

Cover Letter(s)

Dongguan Qianfeng Electronics Co., Ltd American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 Conf identiality Request regarding application for certification of FCC ID: COXADAMIHKT31UB. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram Block Diagram.pdf Schematics Schematics.pdf Operational Description Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, ---- ---------------------------------- Name/Title Adam Wen/Marketing Manager Company Name: Dongguan Qianfeng Electronics Co., Ltd Address: No 380, Xinfeng Road, Shijie Town, Dongguan City, Guangdong Tel: 0769-88480078 Fax: 0769-88480011 Email:[email protected]

External Photos

External Photos

ID Label/Location Info

流水号

Internal Photos

Internal Photos

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. 198 Kezhu Road, Scientech Park, Guangzhou Ec onomic & Technol ogical D evel opment District, Guangzhou, Chi na 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: ee.guangzhou@s gs.com FEDERAL COMMUNICATIONS COMMISSION Registration number: 282399 Report No.: GZEM140400147201 Page: 1 of 16 FCC ID: COXADAMIHKT31UB Authorized Signature: Richard Li Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only 1 Cover Page TEST REPORT Application No.: GZEM1404001472HS Applicant: DONGGUAN QIANFENG ELECTRONICS CO., LTD. FCC ID: COXADAMIHKT31UB Product Name: INDUCTION COOK TOP Product Description: INDUCTION COOKER Model No.: IHK-T31U-B Trade Mark: IRIS OHYAMA, QIANFENG Standards: FCC CFR 47 PART 18: 2013 Date of Receipt: 2014-04-08 Date of Test: 2014-04-11 to 2014-09-20 Date of Issue: 2014-10-10 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Report No.: GZEM140400147201 Page: 2 of 16 FCC ID: COXADAMIHKT31UB This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 2 Version Revision Record Version Chapter Date Modifier Remark 00 2014-10-10 Original Authorized for issue by: Tested By 2014-04-11 to 2014-09-20 (Michael Huang) / Project Engineer Date Prepared By 2014-09-28 (Millie Li) / Clerk Date Checked By 2014-10-10 (Kobe Jian)/ Reviewer Date SGS-CSTC Standards Technical Services Co., Ltd. Report No.: GZEM140400147201 Page: 3 of 16 FCC ID: COXADAMIHKT31UB This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 3 Test Summary Electromagnetic Interference (EMI) Test Test Requirement Test Method Class / Severity Result Conducted Emission (9 kHz to 30 MHz) FCC PART 18: 2013 FCC OST/ MP-5:1986 18.307(a) PASS Radiated Emission (9 kHz to 30 MHz) FCC PART 18: 2013 FCC OST/ MP-5:1986 18.305(b) PASS ** Remark : EUT: In this wh…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup Photos 1.1 CON DU CTED EM ISSI ON S, 9 KHZ TO 30 MHZ TEST SET UP 1.2 RADI ATE D EM ISS IO NS, 9 KHZ T O 30 MHZ TE S T SETU P

Contact Information

Applicant

ADAM WEN(MARKETING MANAGER)
[email protected]+86 0769-88480078Fax: +86 0769-88480011

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Michael Huang
86-20-82155333

198 KEZHU Road, Scientech Park, Guangzhou · Guangzhou, Guangdong · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.June Chen
[email protected]86-20-82155318

Test Firm

SGS-CSTC Standards Technical Services Co., LtdJerry Chan
[email protected]860-208215-5331Fax: 860-208207-5059

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.019 MHz - 0.028 MHz-
Confidentiality
Long Term

Other Applications from DONGGUAN QIANFENG ELECTRONICS CO.,LTD.

Induction Cooker - FCC ID COXIHQF151BQF12 - DONGGUAN QIANFENG ELECTRONICS CO.,LTD.
COXIHQF151BQF12

Induction Cooker

Nov 14, 2012

Equipment Class

8CC - Part 18 Consumer Device
Induction Cooker - FCC ID COXIHAID507QF12 - DONGGUAN QIANFENG ELECTRONICS CO.,LTD.
COXIHAID507QF12

Induction Cooker

Jul 10, 2012

Equipment Class

8CC - Part 18 Consumer Device
INDUCTION COOKETOP - FCC ID COXIHCPIC14QF12 - DONGGUAN QIANFENG ELECTRONICS CO.,LTD.
COXIHCPIC14QF12

INDUCTION COOKETOP

May 03, 2012

Equipment Class

8CC - Part 18 Consumer Device