FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shure Incorporated/
  3. DD4MXW1

DD4MXW1BodyPack Transmitter

Shure Incorporated
BodyPack Transmitter - FCC ID DD4MXW1 - Shure Incorporated
Click to zoom

Application Details

Equipment Class
PUT - Part 15 Unlicensed PCS portable Tx worn on body
Date of Grant
Oct 09, 2012
Application Purpose
Original Equipment
Date of Application
Oct 08, 2012
Equipment Note
BodyPack Transmitter
Frequency Range
1921.53600000 - 1928.44800000
Company
Shure Incorporated
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

©2012 Shure Incorporated 27WG20831 (Rev. 1) MXW Wireless Conference System 10/02/12 10/02/12 IMPORTANT SAFETY INSTRUCTIONS 1. READ these instructions. 2. KEEP these instructions. 3. HEED all warnings. 4. FOLLOW all instructions. 5. DO NOT use this apparatus near water. 6. CLEAN ONLY with dry cloth. 7. DO NOT block any ventilation openings. Allow sufficient distances for adequate ventila- tion and install in accordance with the manufacturer’s instructions. 8. DO NOT install near any heat sources such as open flames, radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not place any open flame sources on the product. 9. DO NOT defeat the safety purpose of the polarized or groundingtype plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replace- ment of the obsolete outlet. 10. PROTECT the power cord from being walked on or pinched, particularly at plugs, conve- nience receptacles, and the point where they exit from the apparatus. 11. ONLY USE attachments/accessories specified by the manufacturer. 12. USE only with a cart, stand, tripod, bracket, or table specified by the manu- facturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. UNPLUG this apparatus during lightning storms or when unused for long periods of time. 14. REFER all servicing to qualified service personnel. Servicing is required when the ap- paratus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with liquids, such as vases, on the apparatus. 16. The MAINS plug or an appliance coupler shall remain readily operable. 17. The airborne noise of the Apparatus does not exceed 70dB (A). 18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection. 19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 20. Do not attempt to modify this product. Doing so could result in personal injury and/or product failure. 21. Operate this product within its specified operating temperature range. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and mainte- nance instructions in the literature accompanying this unit. WARNING: This product contains a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. INSTRUCCIONES IMPORTANTES DE SEGURIDAD 1. LEA estas instrucciones. 2. CONSERVE estas instrucciones. 3. PRESTE ATENCION a todas las advertencias. 4. SIGA todas las instrucciones. 5. NO utilice este aparato cerca del agua. 6. LIMPIE UNICAMENTE con un trapo seco. 7. NO obstruya ninguna de las aberturas de ventilación. Deje espacio suficiente para proporcionar ventilación adecuada e instale los equipos según las instrucciones del fabricante. 8. NO instale el aparato cerca de fuentes de calor tales como llamas descubiertas, radiad- ores, registros de calefacción, estufas u otros aparatos (incluyendo amplificadores) que produzcan calor. No coloque artículos con llamas descubiertas en el producto. 9. NO anule la función de seguridad del enchufe polarizado o con clavija de puesta a tierra. Un enchufe polarizado tiene dos patas, una más ancha que la otra. Un enchufe con pu- esta a tierra tiene dos patas y una tercera clavija con puesta a tierra. La pata más ancha o la tercera clavija se proporciona para su seguridad. Si el tomacorriente no es del tipo apropiado para el enchufe, consulte a un electricista para que sustituya el tomacorriente de estilo anticuado. 10. PROTEJA el cable eléctrico para evitar que personas lo pisen o estrujen, particularmente en sus enchufes, en los tomacorrientes y en el punto en el cual sale del aparato. 11. UTILICE únicamente los accesorios especificados por el fabricante. 12. UTILICE únicamente con un carro, pedestal, trípode, escuadra o mesa del tipo especificado por el fabricante o vendido con el aparato. Si se usa un carro, el mismo debe moverse con sumo cuidado para evitar que se vuelque con el aparato. 13. DESENCHUFE el aparato durante las tormentas eléctricas, o si no va a ser utilizado por un lapso prolongado. 14. TODA reparación debe ser llevada a cabo por técnicos calificados. El aparato requiere reparación si ha sufrido cualquier tipo de daño, incluyendo los daños al cordón o enchufe eléctrico, si se derrama líquido sobre el aparato o si caen objetos en su interior, si ha sido expuesto a la lluvia o la humedad, si no funciona de modo normal, o si se ha caído. 15. NO exponga este aparato a chorros o salpicaduras de líquidos. NO coloque objetos llenos con líquido, tales como floreros, sobre el aparato. 16. El enchufe de alimentación o un acoplador para otros aparatos deberá permanecer en buenas condiciones de funcionamiento. 17. El nivel de ruido transmitido por el aire del aparato no excede de 70 dB(A). 18. Los aparatos de fabricación CLASE I deberán conectarse a un tomacorriente de ALI- MENTACION con clavija de puesta a tierra protectora. 19. Para reducir el riesgo de causar un incendio o sacudidas eléctricas, no exponga este aparato a la lluvia ni a humedad. 20. No intente modificar este producto. Hacerlo podría causar lesiones personales y/o la falla del producto. 21. Utilice este producto únicamente dentro de la gama de temperaturas de funcionamiento especificadas. Este símbolo indica que la unidad contiene nivel…

Text truncated - open the document above for the full version.

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 September 25, 2012 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission's Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCCID Model name DD4MXW1 MXW110Z10 For the product stated above, we request permanent confidentiality for exhibits which contain Operational Description, Block Diagram, Schematics, Parts Lists or Tune Up Information. The above exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact me at the address shown below. Sincerely, t,~/; I" .. ~ Name: Craig Kozokar Company: Shure Incorporated Address: 5800 W. Touhy Ave. Niles, IL 60714 Phone: 847-600-8652 Fax: Email: [email protected]

External Photos

Test report no.: 1-4439/12-02-06 2012-09-03 Page 56 of 63 Annex B: External Photographs of the EUT Photo 1: Photo 2: Test report no.: 1-4439/12-02-06 2012-09-03 Page 57 of 63 Photo 3: Photo 4: Test report no.: 1-4439/12-02-06 2012-09-03 Page 58 of 63 Photo 5: Photo 6:

ID Label/Location Info

MXW1/O Z10 – Label Location

Internal Photos

Test report no.: 1-4439/12-02-06 2012-09-03 Page 59 of 63 Annex C: Internal Photographs of the EUT Photo 1: Photo 2: Test report no.: 1-4439/12-02-06 2012-09-03 Page 60 of 63 Photo 3: Photo 4:

RF Exposure Info

Page 1 of 30 TEST REPORT Test Report No.: 1-4439/12-02-08-B Testing Laboratory Applicant CETECOM ICT Services GmbH UntertĂĽrkheimer StraĂźe 6 – 10 66117 SaarbrĂĽcken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Test Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 SHURE Inc. 5800 West Touhy Avenue Niles, IL 60714-4608/UNITED STATES Phone: 1- 847-600-2000 Contact: Geoff Lange e-mail: [email protected] Phone: 1- 847-600-8923 Fax: 1- 847-600-1212 Manufacturer SHURE Inc. 5800 West Touhy Avenue Niles, IL 60714-4608/UNITED STATES Test Standard/s OET Bulletin 65 Supplement C Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields RSS-102 Issue 4 Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Wireless Audio Conferencing Device type: portable device Model name: Micro-Flex Wireless (MXW1/O Z10) Hybrid Body- pack, with Omni mic S/N serial number: 4121370018 FCC-ID: DD4MXW1 IC: 616A-MXW1 Hardware status: 01 Software status: 0.1.0.0 Frequency: see technical details Antenna: integrated antenna Battery option: integrated battery Accessories: --- Test sample status: identical prototype Exposure category: general population / uncontrolled environment This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test Report authorised: Test performed: Thomas Vogler Oleksandr Hnatovskiy Senior Testing Manager Testing Manager Test report no.: 1-4439/12-02-08-B Page 2 of 30 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2 General information .................................................................................................................................. 3 2.1 Notes and disclaimer ..................................................................................................................... 3 2.2 Application details ......................................................................................................................... 3 2.3 Statement of compliance ............................................................................................................... 3 2.4 Technical details............................................................................................................................. 4 3 Test standards/ procedures references .................................................................................................. 5 3.1 RF exposure limits ......................................................................................................................... 6 4 Summary of Measurement Results ......................................................................................................... 7 5 Test Environment ...................................................................................................................................... 7 6 Test Set-up ................................................................................................................................................. 8 6.1 Measurement system ..................................................................................................................... 8 6.1.1 System Description ................................................................................................................ 8 6.1.2 Test environment ................................................................................................................... 9 6.1.3 Probe description ................................................................................................................... 9 6.1.4 Phantom description ............................................................................................................ 10 6.1.5 Device holder description .................................................................................................... 10 6.1.6 Scanning procedure ............................................................................................................ 11 6.1.7 Spatial Peak SAR Evaluation .............................................................................................. 12 6.1.8 Data Storage and Evaluation............................................................................................... 13 6.1.9 Tissue simulating liquids: dielectric properties .................................................................... 15 6.1.10 Tissue simulating liquids: parameters ................................................................................. 15 6.1.11 Measurement uncertainty evaluation for the test ................................................................ 16 6.1.12 Measurement uncertainty evaluation for system check ...................................................... 17 6.1.13 System check ...................................................................................................................... 18 6.1.14 System check procedure ..................................................................................................... 18 7 Detailed Test Results .............................................................................................................................. 19 7.1 Conducted power measurements DECT 1925 MHz .................................................................. 19 …

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 29 Annex E Appendix to Test Report No.: 1-4439/12-02-08-B Testing Laboratory CETECOM ICT Services GmbH UntertĂĽrkheimer StraĂźe 6 – 10 66117 SaarbrĂĽcken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Test Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 Appendix with Calibration data, Phantom certificate and system check information Annex E to Test report no.: 1-4439/12-02-08-B Page 2 of 29 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2 Calibration report “Probe ET3DV6” ......................................................................................................... 3 3 Calibration report “1900 MHz System validation dipole” .................................................................... 14 4 Calibration certificate of Data Acquisition Unit (DAE) ........................................................................ 22 5 Certificate of “SAM Twin Phantom V4.0/V4.0C’’ ................................................................................. 23 6 Application Note System Performance Check ..................................................................................... 24 6.1 Purpose of system performance check ..................................................................................... 24 6.2 System Performance check procedure ...................................................................................... 24 6.3 Uncertainty Budget ...................................................................................................................... 25 6.4 Power set-up for validation ......................................................................................................... 28 6.5 Laboratory reflection ................................................................................................................... 29 6.6 Additional system checks ........................................................................................................... 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 3 of 29 2 Calibration report “Probe ET3DV6” Annex E to Test report no.: 1-4439/12-02-08-B Page 4 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 5 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 6 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 7 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 8 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 9 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 10 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 11 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 12 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 13 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 14 of 29 3 Calibration report “1900 MHz System validation dipole” Annex E to Test report no.: 1-4439/12-02-08-B Page 15 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 16 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 17 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 18 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 19 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 20 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 21 of 29 Annex E to Test report no.: 1-4439/12-02-08-B Page 22 of 29 4 Calibration certificate of Data Acquisition Unit (DAE) Annex E to Test report no.: 1-4439/12-02-08-B Page 23 of 29 5 Certificate of “SAM Twin Phantom V4.0/V4.0C’’ Annex E to Test report no.: 1-4439/12-02-08-B Page 24 of 29 6 Application Note System Performance Check 6.1 Purpose of system performance check The system performance check verifies that the system operates within its specifications. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper functioning of many components and the correct settings of many parameters. Faulty results due to drift, failures or incorrect parameters might not be recognized, since they often look similar in distribution to the correct ones. The Dosimetric Assessment System DASY4 incorporates a system performance check procedure to test the proper functioning of the system. The system performance check uses normal SAR measurements in a simplified setup (the flat section of the SAM Twin Phantom) with a well characterized source (a matched dipole at a specified distance). This setup was selected to give a high sensitivity to all parameters that might fail or vary over time (e.g., probe, liquid parameters, and software settings) and a low sensitivity to external effects inherent in the system (e.g., positioning uncertainty of the device holder). The system performance check does not replace the calibration of the components. The accuracy of the system performance check is not sufficient for calibration purposes. It is possible to calculate the field quite accurately in this simple setup; however, due to the open field situation some factors (e.g., laboratory reflections) cannot be accounted for. Calibrations in the flat phantom are possible with transfer calibration methods, using either temperature probes or calibrated E-field probes. The system performance check also does not test the system performance for arbitrary field situations encountered during real measurements of mobile phones. These checks are performed at SPEAG by testing the components under various co…

Text truncated - open the document above for the full version.

Test Report

2012-09-03 Page 1 of 63 TEST REPORT Test Report No.: 1-4439/12-02-06 Testing Laboratory Applicant CETECOM ICT Services GmbH UntertĂĽrkheimer StraĂźe 6 – 10 66117 SaarbrĂĽcken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Test Laboratory: The testing laboratory (FCC part 15 D) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-01 Shure 5800 Touhy Avenue Niles, IL USA 60714 Phone: + 1-847-600-2000 Fax: + 1-847-600-1212 Contact: Mr. Geoff Lange e-mail: [email protected] Phone: + 1-847-600-8923 Manufacturer Shure 5800 Touhy Avenue Niles, IL USA 60714 Test Standard/s FCC Part 15, subpart D Isochronous UPCS Device 1920 – 1930 MHz Industry Canada RSS-213, Issue 2 2 GHz Licence-exempt Personal Communication Service Devices (LE-PCS) Test Item Kind of test item: DECT Portable Part Model name: MXW1/O Z10 BILD FCC ID: DD4MXW1 IC: 616A-MXW1 S/N serial number: 4121370038 HW hardware status: 01 SW software status: 0.1.0.0 Frequency [MHz]: 1920 -1930 Type of Modulation: Digital (Gaussian Frequency Shift Keying) Number of channels: 5 RF Channels, 5x12 = 60 TDMA Duplex Channels Antenna: 2 permanently attached chip antennas Power Supply: 3.7 V DC Temperature Range: -20°C to 50°C Test Report authorised: Test performed: 2012-09-03 Lenjoint, Marco 2012-09-03 Wolf, Joachim Testing Manager Senior Consultant cn=Joachim Wolf, o=CETECOM ICT Services GmbH, ou=WOL-110131, email=Joachim.Wolf@cetecom. com, c=DE 2012.10.01 13:28:02 +02'00' cn=Marco Lenjoint, o=CETECOM ICT Services GmbH, ou=LEJ-100721, email=marco.lenjoint@cetec om.com, c=DE 2012.10.02 07:13:57 +02'00' Test report no.: 1-4439/12-02-06 2012-09-03 Page 2 of 63 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2General information .................................................................................................................................. 4 2.1Notes and disclaimer ..................................................................................................................... 4 2.2Application details ......................................................................................................................... 4 3Test standard/s: ......................................................................................................................................... 4 4Test Environment ...................................................................................................................................... 5 5Test Item ..................................................................................................................................................... 5 6RSP100 Test report Cover Sheet/Performance Test Data ..................................................................... 6 7Summary of Measurement Results ......................................................................................................... 7 8Test Set-up ................................................................................................................................................. 8 8.1Frequency Measurements ............................................................................................................. 8 8.2Timing Measurements ................................................................................................................... 8 8.3Conducted Emission Test ............................................................................................................. 8 8.4Radiated Emission Test ................................................................................................................. 9 8.5Power Line Conducted Emissions Test ....................................................................................... 9 8.6Monitoring Tests........................................................................................................................... 10 8.7Radiated Output Power Test ....................................................................................................... 10 9Detailed Test Results .............................................................................................................................. 11 9.1Power Line Conducted Emissions ............................................................................................. 11 9.2Coordination with fixed microwave ............................................................................................ 14 9.3Digital Modulation Techniques ................................................................................................... 14 9.4Labeling Requirements ................................................................................................................ 14 9.5Antenna Requirements ................................................................................................................ 15 9.6Channel Frequencies ................................................................................................................... 15 9.7Automatic Discontinuation of Transmission ............................................................................. 16 9.8Peak Power Output ...................................................................................................................... 17 9.9E m i s s i o n B a n d w i d t h B ......................................................................................................... 22 9.10Power Spectral Density ............................................................................................................ 25 9.11In…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report no.: 1-4439/12-02-06 2012-09-03 Page 55 of 63 Annex A: Photographs of the Test Set-up Photo 1: Power Line Conducted Emission Test Photo 2: Radiated Emission

Contact Information

Applicant

Craig Kozokar(EMC Project Engineer)
[email protected]847-600-8652Fax: 847-600-8505

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115D1.92 GHz - 1.93 GHz71.00 mW4.5000000000 ppm
Confidentiality
Long Term
Grant Notes
Power listed is peak conducted. Device has been tested for SAR compliance for body-worn configurations. This device must transmit with a source-based time-averaging duty factor as described in this filing. The highest reported SAR value is <0.1 W/kg.

Other Applications from Shure Incorporated

DD4IMXBP

UC Wall

Dec 24, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX
DD4SLXD3EG57

Plug-on Wireless Transmitter

Jul 25, 2025

Equipment Class

DTS - Digital Transmission System
Wireless Gooseneck Transmitter - FCC ID DD4ULXD8G50 - Shure Incorporated
DD4ULXD8G50

Wireless Gooseneck Transmitter

Sep 18, 2024

Equipment Class

DWM - Part 15 Wireless Microphone
Wireless Gooseneck Transmitter - FCC ID DD4ULXD8H50 - Shure Incorporated
DD4ULXD8H50

Wireless Gooseneck Transmitter

Sep 18, 2024

Equipment Class

DWM - Part 15 Wireless Microphone
Wireless Boundary Transmitter - FCC ID DD4ULXD6G50 - Shure Incorporated
DD4ULXD6G50

Wireless Boundary Transmitter

Sep 08, 2024

Equipment Class

TLD - Licensed LPAS Device