FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Fluidmaster Inc./
  3. DNX13D4011936X

DNX13D4011936XSoft Spa 9500

Fluidmaster Inc.
Soft Spa 9500 - FCC ID DNX13D4011936X - Fluidmaster Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 23, 2020
Application Purpose
Original Equipment
Date of Application
Sep 23, 2020
Equipment Note
Soft Spa 9500
Frequency Range
2405.00000000 - 2470.00000000
Company
Fluidmaster Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WIP IMAGE LEGEND soft spa 9500 instructions NEED IMAGE Already taken NEED IMAGE Need to shoot REFERENCE Use attached as reference EDIT TEXT Need to edit text/directions IMAGE TEXT Image requires text explanation 5($'$//,16758&7,216%()25(,167$//$7,21$1'86( ,03257$176$)(*8$5'6 When using the electronic product, especially in the presence of children, basic safety precautions should always be followed, including the following. Please read all instructions before use DANGER-Reduce the risk of electric shock 1. Do not use while bathing 2. Do not place or store the product where it may fall or be dragged into a bathtub or sink. 3. Do not place in or drop into water or other liquid. 4. Do not touch the product if it falls into the water and unplug the power supply immediately. WARNING-Reduce the risk of burns, electric shock, fire or personal injury 1. Please keep a close watch when children or disabled persons are using or near the products in use. 2. Children should not use the product without adult supervision. 3. Be sure to adjust the toilet seat’s temperature for children, elders, handicapped persons or people with sensitive skin. 4. This product is used only for the intended purpose described in this manual. Do not use accessories not recommended by the manufacturer. 5. Install the unit properly by following the installation procedures in the instruction manual. 6. Never operate this product if it has a damaged cord or plug or if it is not working properly, if it has been dropped or damaged, or dropped int o water. Return the product to a service center for examination and repair. 7. Keep the power cord away from the heating surface. 8. Do not clog the pores of the product, or place the product on a soft surface, such as a bed or sofa, where the pores may be blocked. Keep the air unblocked and no cotton wool or hair, etc.in the pores. 9. Don't use products while sleeping or drowsy. 10. Do not put or insert any object into any opening or hose. 11. Do not use outdoors or operate where aerosol (spray) products are being used or when oxidized products are being administered 12. Unplug this product before filling. Fill (reservoir) with water. Do not overfill (or specify filling instructions) 13. Only authorized persons can install or repair the unit. Do not attempt to service this appliance by yourself. 14. Always follow the grounding instructions in this manual before plugging in the unit. ISED Warning Statements ISED 7KLVGHYLFHFRQWDLQVOLFHQFHH[HPSWWUDQVPLWWHU V UHFHLYHU V WKDWFRPSO\ZLWK,QQRYDWLRQ6FLHQFHDQG(FRQRPLF'HYHORSPHQW&DQDGD·VOLFHQFH H[HPSW566 V 2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV  7KLVGHYLFHPD\QRWFDXVHLQWHUIHUHQFH  7KLVGHYLFHPXVWDFFHSWDQ\LQWHUIHUHQFHLQFOXGLQJLQWHUIHUHQFHWKDWPD\FDXVHXQGHVLUHGRSHUDWLRQRIWKHGHYLFH /·pPHWWHXUUpFHSWHXUH[HPSWGHOLFHQFHFRQWHQXGDQVOHSUpVHQWDSSDUHLOHVWFRQIRUPHDX[&15G·,QQRYDWLRQ6FLHQFHVHW'pYHORSSHPHQW pFRQRPLTXH&DQDGDDSSOLFDEOHVDX[DSSDUHLOVUDGLRH[HPSWVGHOLFHQFH/·H[SORLWDWLRQHVWDXWRULVpHDX[GHX[FRQGLWLRQVVXLYDQWHV  /·DSSDUHLOQHGRLWSDVSURGXLUHGHEURXLOODJH  /·DSSDUHLOGRLWDFFHSWHUWRXWEURXLOODJHUDGLRpOHFWULTXHVXELPrPHVLOHEURXLOODJHHVW VXVFHSWLEOHG·HQFRPSURPHWWUHOHIRQFWLRQQHPHQW. FCC Warning statements in User Manual This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. CAUTIONS BEFORE INSTALLATION WIRING REQUIREMENTS THIS PRODUCT MUST BE PLUGGED into a regular voltage Grounded GFCI outlet (North America 120V AC, 60Hz). The rated power consumption is W. WARNING: This Product must be on a separated circuit. No other appliance should share the circuit with this product. Sharing a circuit could cause the branch circuit fuse to blow or the circuit breaker to trip. Continuous usage under these conditions may result in fire or property damage. GROUNDING INSTRUCTIONS – This appliance has to be grounded. This product should be grounded. In the case of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape path for the current. This product is equipped with a power cord with a ground wire. DANGER: Improper use of the grounding plug may result in electric shock. If the power cord or plug needs to be repaired or replaced, do not connect the ground wire to any of the flat pins. The conductor with green strip or without yellow stripe on the outer insulation surface is grounding wire. If you do not fully understand the grounding instructions or if you have…

Text truncated - open the document above for the full version.

Cover Letter(s)

30800 Rancho Viejo Road  San Juan Capistrano, California 92675 Phone: (949) 728-2000 www.fluidmaster.com 2020 September 03 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Verification Services Inc. as our representative, we still recognize that we are responsible to: a) Comply with the relevant provisions of the certification program; b) Make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) Make claims regarding certification only in respect of the scope for which certification has been granted; d) Do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) Upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) Use certification only to indicate the products are certified as being in conformity with specified standards; 30800 Rancho Viejo Road  San Juan Capistrano, California 92675 Phone: (949) 728-2000 www.fluidmaster.com g) Endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) Ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) Keep a record of all complaints made known to us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the when requested; j) Take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) Document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signed by: Company Name: Fluidmaster Inc. Contact Name: David L Marbry Title of Person: Senior Engineer, Global Codes and Standards Address: 30800 Rancho Viejo Road, San Juan Capistrano, CA 92675 United States

Cover Letter(s)

30800 Rancho Viejo Road  San Juan Capistrano, California 92675 Phone: (949) 728-2000 www.fluidmaster.com 2020 September 11 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: DNX13D4011936X To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards Company Name: Fluidmaster Inc. Contact Name: David L Marbry Title of Person: Senior Engineer, Global Codes and Standards Address: 30800 Rancho Viejo Road, San Juan Capistrano, CA 92675 United States Date: 09/11/2020

External Photos

Appendix I External Photographs Page 2 of 2 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. View of EUT-1 View of EUT-2

ID Label/Location Info

Label: 13D401-1936X FCC ID :DNX13D4011936X IC:26416-13D4011936X

Internal Photos

Appendix II Internal Photographs Page 2 of 5 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-1 Internal View of EUT-2 Page 3 of 5 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-3 Internal View of EUT-4 Page 4 of 5 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-5 Internal View of EUT-6 Antenna Page 5 of 5 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-7

Test Report

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 15 SUBPART C ISED RSS-210 ISSUE 10 TEST REPORT For Soft Spa 9500 MODEL NUMBER: 13D401-1936X FCC ID: DNX13D4011936X IC: 26416-13D4011936X REPORT NUMBER: 4789569971-2 ISSUE DATE: August 25, 2020 Prepared for Fluidmaster Inc. 30800 Rancho Viejo Road,San Juan Capistrano,CA 92675 USA Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Building 10, Innovation Technology Park, No. 1, Li Bin Road, Song Shan Lake Hi- Tech Development Zone Dongguan, 523808, People’s Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4789569971-2 Page 2 of 50 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0058 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 08/25/2020 Initial Issue REPORT NO.: 4789569971-2 Page 3 of 50 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0058 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Clause Test Items FCC/ISED Rules Test Results 1 20dB Bandwidth and 99% Occupied Bandwidth CFR 47 FCC §15.215 (d ) ISED RSS-Gen Clause 6.7 Pass 2 Radiated Emission CFR 47 FCC §15.249 (a)(d)(e) ISED RSS-210 Annex B B.10 CFR 47 FCC §15.205 and §15.209 RSS-GEN Clause 8.9 RSS-GEN Clause 8.10 Pass 3 Antenna Requirement CFR 47 FCC §15.203 ISED RSS-Gen Clause 6.3 Pass Note 1: This test report is only published to and used by the applicant, and it is not for evidence purpose in China. Note 2: The measurement result for the sample received is <Pass> according to < CFR 47 FCC PART 15 SUBPART C, ISED RSS-210 Issue 10 and ISED RSS-GEN Issue 5 > when <Accuracy Method> decision rule is applied. REPORT NO.: 4789569971-2 Page 4 of 50 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0058 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS .................................................................................... 5 2. TEST METHODOLOGY ........................................................................................................ 6 3. FACILITIES AND ACCREDITATION .................................................................................... 6 4. CALIBRATION AND UNCERTAINTY .................................................................................. 7 4.1. MEASURING INSTRUMENT CALIBRATION ................................................................ 7 4.2. MEASUREMENT UNCERTAINTY ................................................................................. 7 5. EQUIPMENT UNDER TEST ................................................................................................. 8 5.1. DESCRIPTION OF EUT ................................................................................................. 8 5.2. MAXIMUM FIELD STRENGTH ...................................................................................... 8 5.3. CHANNEL LIST .............................................................................................................. 8 5.4. DESCRIPTION OF AVAILABLE ANTENNAS ................................................................ 8 5.5. TEST CHANNEL CONFIGURATION ............................................................................. 8 5.6. THE WORSE CASE POWER SETTING PARAMETER ................................................. 9 5.7. TEST ENVIRONMENT ................................................................................................... 9 5.8. DESCRIPTION OF TEST SETUP ................................................................................ 10 5.9. MEASURING INSTRUMENT AND SOFTWARE USED .............................................. 11 6. ANTENNA PORT TEST RESULTS .................................................................................... 12 6.1. ON TIME AND DUTY CYCLE ...................................................................................... 12 6.2. 20 dB BANDWIDTH AND 99% OCCUPIED BANDWIDTH .......................................... 14 7. RADIATED TEST RESULTS .............................................................................................. 18 7.1. LIMITS AND PROCEDURE ......................................................................................... 18 7.2. RESTRICTED BANDEDGE AND FIELD STRENGTH OF INTENTIONAL EMISSIONS 25 7.3. SPURIOUS EMISSIONS (1~3GHz) ............................................................................. 31 7.4. SPURIOUS EMISSIONS (3~18GHz) ........................................................................... 37 7.5. SPURIOUS EMISSIONS (18~26GHz) ......................................................................... 43 7.6. SPURIOUS EMISSIONS BELOW 30MHz ................................................................... 45 7.7. SPURIOUS EMISSIONS BELOW 1GHz AND ABOVE 30MHz ................................... 48 8. ANTENNA REQUIREMENTS ............................................................................................. 50 REPORT NO.: 4789569971-2 Page 5 of 50 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0058 This report shall not be reproduced except in full, without the written approval of UL …

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix II Setup Photographs RADIATED RF MEASUREMENT SETUP (30MHz ~ 1 GHz) RADIATED RF MEASUREMENT SETUP (Below 30MHz) RADIATED RF MEASUREMENT SETUP (Above 1G – X axis) RADIATED RF MEASUREMENT SETUP (Above 1G – Y axis) RADIATED RF MEASUREMENT SETUP (Above 1G – Z axis)

Contact Information

Applicant

David Marbry
[email protected]9497282736

Test Firm

UL Verification Services (Guangzhou) Co., Ltd.Stephen Guo
[email protected]+86 0769 33817120

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.47 GHz-
Confidentiality
Long Term