E5MDS-EL805MDS TransNet 900

GE MDS, LLC
MDS TransNet 900 - FCC ID E5MDS-EL805 - GE MDS, LLC
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 30, 2002
Application Purpose
Original Equipment
Date of Application
Mar 18, 2002
Equipment Note
MDS TransNet 900
Frequency Range
902.20000000 - 927.80000000
Company
GE MDS, LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MDS 05-2708A01, Rev. APage 1 of 2 MDS TransNET 900 Transceiver ADDENDUM Addendum to MDS 05-2708A01, Rev. AApril 19, 2002 Microwave Data Systems Inc., 175 Science Parkway, Rochester, NY 14620 U.S.A. General Business +1 (585) 242-9600, FAX +1 (585) 242-9620 This addendum contains corrections and additions to the MDS TransNET 900 Installation Guide (MDS P/N 05- 2708A01, Rev. A) published in March 2002. The Bolded text below indicates new or revised material. You may wish to make these pen & ink changes directly to your manual or include a reference to this addendum in the appropriate sections. ITEM 1—Command Changes Page 19, Data Buffer Setting: Default setting is OFF. Page 25, BUFF [ON, OFF]: Default setting is OFF. Page 26, CTSHOLD [0-6000]: Should read CTSHOLD [0-60000]. Page 28, RSSI description: Change reference to minimum output range from “-50 dBm” to “-40 dBm.” Page 30, SKIP [NONE, 1...8] description: Delete text reference to “128 frequency.” Page 31, TX [xxxx] description: Default Transmit Frequencies are Master—902.200 MHz, Remote—927.800 MHz. ITEM 2—Table 8. Alarm Codes, Page 34 For Alarm Code 30, delete second sentence that reads “Bit errors are likely to be present in the data.” ITEM 3—Internal Fuse Replacement, Page 35 Reverse polarity will not cause the fuse to blow. ITEM 4—Technical Specifications, Page 38 Change Temperature Range from “-30C to +60C” to “-40 to +70C.” Change Current Draw (Receive) rating from “125 mA @ 13.8 Vdc” to “100 mA @ 13.8 Vdc.” Delete “TTL/” reference. Change Data Latency from “10 ms typical” to “7 ms typical.” ITEM 5—Table 10. Data connector pin descriptions—RS/EIA-232, Page 40 Delete entire text description for Pin 9 and replace with “Not Used.” ITEM 6— Table 11. Data connector pin descriptions—RS/EIA-232, Page 41 Change table title to “Data connector pin descriptions—RS/EIA-485.” In Pin 2 description, change heading from “RXD/Y” to “RXD/+.” Also, replace the words “Non-inverted driver output” with “non-inverted receive data.” In Pin 3 description, change heading from “TXD/A” to “TXD/+.” Also, replace the words “Non-inverted receiver input” with “non-inverted transmit data” Page 2 of 2MDS 05-2708A01, Rev. A In Pin 7 description, change heading from “RTS/B—Request-to-Send” to “TXD/-.” Also, replace the words “Inverted receiver input” with “Inverted transmit data.” In Pin 8 description, change heading from “CTS/Z—Clear-to-Send” to “RXD/-.” Also, delete all descriptive text and replace with “Inverted receive data.” ITEM 7— New PORT Command The transceiver’s DATA port configuration (RS-232 or RS-485) may be read by entering the PORT command. The port may be configured for RS-232 or RS-485 operation using the following commands: PORT RS232—RS-232 operation PORT RS485—RS-485 operation ITEM 8— Wiring for RS-485 systems When wiring the transceiver’s DATA connector for RS-485 2-wire or 4-wire operation, use one of the following arrangements : TXD/+ RXD/+ 2 3 7 DATA CONNECTOR 8 RXD/- TXD/- 4-WIRE CONNECTIONS RX/TX+ 2 3 7 DATA CONNECTOR 8 2-WIRE CONNECTIONS RX/TX- ITEM 9— Antenna & Feedline Selection, Page 9 Currently, the transceiver is only authorized for use in the USA with an MDS Clearwave antenna, Part Number 97-3662A13 and a 3-meter feedline. Check with MDS for the status on additional approvals that are pending. End of Document

Cover Letter(s)

March 18, 2002 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: FCC Certification Authorization Application Under FCC PART 15, Subpart C, Section 15.247 - Frequency Hopping Spread Spectrum Transmitters Operating in the Frequency Band 902.2 - 927.8 MHz. Product: TransNet Model No.: EL805 FCC ID: E5MDS-EL805 Dear Sir/Madam As appointed agent for Microwave Data Systems Inc., we would like to submit the application to the Federal Communications Commission for certification of the above product. Please review all necessary files uploaded to FCC OET website for detailed information. The above product was certified under FCC ID: E5M-TRANSNET900 by FCC TCB and inspected by FCC under surveillance program, complied with a separation distance of 2 meters from persons. We are resubmitting the same product and test results that was filed under FCC TCB for a new application for mobile with a separation distance of 21 cm for satisfying RF exposure requirements (see section 6.8 of this test report for MPE evaluation). This device required professional installation; installers and end-users will be provided with the appropriate information for satisfying RF exposure compliance and can only be used in enclosures designed by Microwave Data Systems, Inc. such that compliance of the end product is assured. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering UltraTech Group of Labs 31040/SIT A96/TH/0093 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected]

Cover Letter(s)

175 Science Parkway, Rochester, New York 14620 USA (585) 242-9600 Phone (585) 242-9620 Fax January 18, 2002 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject: Request for withholding from public disclosure the schematic diagrams and system block diagrams pursuant to an application for certification. Applicant: Microwave Data Systems Inc. Product: TransNet Model: EL805 FCC ID: E5MDS-EL805 Dear Sir/Madam, We, Microwave Data Systems, would like to request that the schematic diagrams, system block diagram, Theory of Operation and Bill of Materials submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457(d) of the Commission's Rules, and Section 552(b)(4) of the Freedom of Information Act. These sections authorize as a withholding from public inspection materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. If you have any queries, please do not hesitate to contact us at 716 242-9600 Yours truly, Dennis McCarthy Agency Compliance Engineer Microwave Data Systems 175 Science Parkway Rochester NY 14620 Phone (585) 242-8440 Email [email protected]

Cover Letter(s)

175 Science Parkway, Rochester, New York 14620 USA (585) 242-9600 Phone (585) 242-9620 Fax January 18, 2002 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject: Authority to Act as an Agent to FCC Applicant: Microwave Data Systems Inc. Product: TransNet Model: EL850 FCC ID: E5MDS-EL805 Dear Sir/Madam, I hereby appoint UltraTech Engineering Labs Inc. (UltraTech) to act as my agent in preparation of this application to F.C.C. for authorization of equipment under F.C.C. Rules. I also certify that the information provided, properly described the device or system for which authorization is required. Regards Dennis McCarthy Dennis McCarthy Agency Compliance Engineer Microwave Data Systems 175 Science Parkway Rochester NY 14620 Phone (585) 242-8440 Email [email protected]

External Photos

ANNEX 3 – EXTERNAL PHOTOS OF EUT Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A3 - 1 ANNEX 3 – EXTERNAL PHOTOS OF EUT Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A3 - 2 ANNEX 3 – EXTERNAL PHOTOS OF EUT Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A3 - 3 ANNEX 3 – EXTERNAL PHOTOS OF EUT Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A3 - 4 ANNEX 3 – EXTERNAL PHOTOS OF EUT Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A3 - 5

ID Label/Location Info

FCC ID Label Location of Label on Device

Internal Photos

ANNEX 4 – INTERNAL PHOTOS OF EUT Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A4 - 1 ANNEX 4 – INTERNAL PHOTOS OF EUT Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A4 - 2 ANNEX 4 – INTERNAL PHOTOS OF EUT Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A4 - 3

Test Report

ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 1 Plot # 1 20 dB Occupied Bandwidth ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 2 Plot # 2 20 dB Occupied Bandwidth ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 3 Plot # 3 20 dB Occupied Bandwidth ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 4 Plot # 4 Channel Hopping Frequency Separation ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 5 Plot # 5 Average Time of Occupancy Low End of Frequency Band ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 6 Plot # 6 Average Time of Occupancy Low End of Frequency Band ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 7 Plot # 7 Average Time of Occupancy Middle of Frequency Band ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 8 Plot # 8 Average Time of Occupancy Middle of Frequency Band ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 9 Plot # 9 Average Time of Occupancy High End of Frequency Band ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 10 Plot # 10 Average Time of Occupancy High End of Frequency Band ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 11 Plot # 11 Band-Edge Spurious Emissions at Antenna Terminals Low End of Frequency Band Single Frequency Mode ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 12 Plot # 12 Band-Edge Spurious Emissions at Antenna Terminals Low End of Frequency Band Pseudorandom Channel Hopping Mode ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 13 Plot # 13 Band-Edge Spurious Emissions at Antenna Terminals High End of Frequency Band Single Frequency Mode ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 14 Plot # 14 Band-Edge Spurious Emissions at Antenna Terminals High End of Frequency Band Pseudorandom Channel Hopping Mode

Test Report

ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 15 Plot # 15 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 16 Plot # 16 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 17 Plot # 17 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 18 Plot # 18 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 19 Plot # 19 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 20 Plot # 20 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 21 Plot # 21 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 22 Plot # 22 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 23 Plot # 23 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 24 Plot # 24 Spurious Emissions at Antenna Terminals ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 25 Plot # 25 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 26 Plot # 26 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 27 Plot # 27 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 28 Plot # 28 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 29 Plot # 29 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 30 Plot # 30 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 31 Plot # 31 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 32 Plot # 32 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 33 Plot # 33 Radiated Emissions ANNEX 1 - TEST DATA PLOTS Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A1 - 34 Plot # 34 Radiated Emissions

Test Report

TransNet Model No.: EL805 FCC ID: E5MDS-EL805 Applicant: Microwave Data Systems Inc. 175 Science Parkway Rochester, NY USA, 14620 In Accordance With FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15, SUBPART C, SECTION 15.247 Frequency Hopping Spread Spectrum Transmitters Operating in the Frequency band 902.2 - 927.8 MHz UltraTech's File No.: MIC57-FTX This Test report is Issued under the Authority of Tri M. Luu, Professional Engineer, Vice President of Engineering UltraTech Group of Labs Date: March 18, 2002 Report Prepared by: Dan Huynh Tested by: Mr. Hung Trinh, EMI/RFI Technician Issued Date: March 18, 2002 Test Dates: January 2 - 4, 2002 The results in this Test Report apply only to the sample(s) tested, and the sample tested is randomly selected. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] FCC Part 15, Subpart C, Section 15.247 - Frequency Hopping Spread Spectrum Transmitters Contents i TransNet, Model EL805 FCC ID: E5MDS-EL805 ULTRATECH GROUP OF LABS File #: MIC57-FTX 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 February 26, 2002 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) TABLE OF CONTENTS EXHIBIT 1. SUBMITTAL CHECK LIST................................................................................................................... 1 EXHIBIT 2. INTRODUCTION .................................................................................................................................... 2 2.1. SCOPE.................................................................................................................................................................... 2 2.2. RELATED SUBMITTAL ( S )/ GRANT ( S ) .......................................................................................................................... 2 2.3. NORMATIVE REFERENCES .............................................................................................................................. 2 EXHIBIT 3. PERFORMANCE ASSESSMENT .........................................................................................................3 3.1. CLIENT INFORMATION ........................................................................................................................................ 3 3.2. E QUIPMENT UNDER T EST (EUT) INFORMATION................................................................................................. 3 3.3. EUT’S TECHNICAL SPECIFICATIONS............................................................................................................. 4 3.4. L IST OF EUT’ S P ORTS ............................................................................................................................................. 4 3.5. A NCILLARY EQUIPMENT .......................................................................................................................................... 5 EXHIBIT 4. EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS .......................... 6 4.1. C LIMATE TEST CONDITIONS ..................................................................................................................................... 6 4.2. O PERATIONAL TEST CONDITIONS & ARRANGEMENT FOR TEST S .............................................................................. 6 EXHIBIT 5. SUMMARY OF TEST RESULTS .......................................................................................................... 7 5.1. LOCATION OF TESTS ......................................................................................................................................... 7 5.2. APPLICABILITY & S UMMARY OF EMC E MISSION T EST R ESULTS ...................................................................... 7 5.3. MODIFICATIONS INCORPORATED IN THE EUT FOR COMPLIANCE PURPOSES ............................................................... 7 EXHIBIT 6. MEASUREMENTS, EXAMINATIONS & TEST DATA FOR EMC EMISSIONS.......................... 8 6.1. T EST P ROCEDURES .................................................................................................................................................. 8 6.2. MEASUREMENT UNCERTAINTIES .............................................................................................................................. 8 6.3. MEASUREMENT EQUIPMENT USED ............................................................................................................................ 8 6.4. ESSENTIAL/PRIMARY FUNCTIONS AS DECLARED BY THE MANUACTURER ..................................... 8 6.5. COMPLI A NCE WITH FCC PART 15 – GENERAL TECHNICAL REQUIREMENTS ..................................... 9 6.6. H OPPING C HANNEL C ARRIER F REQUENCY C HARACTERISTICS [47 CFR §§ 15.247( A )(1) & ( A )(1)( I )] ................. 13 6.6.1. Limits ............................................................................................................................................................ 13 6.6.2. Method of Measurements.............................................................................................................................. 13 6.6.3. Test Arrangement ......................................................................................................................................... 14 6.6.4. Test Equipment List ...................................................................................................................................... …

Text truncated - open the document above for the full version.

Test Report

FCC Part 15, Subpart C, Section 15.247 - Frequency Hopping Spread Spectrum Transmitters Page 4 TransNet, Model EL805 FCC ID: E5MDS-EL805 ULTRATECH GROUP OF LABS File #: MIC57-FTX 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 March 18, 2002 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) 3.3. EUT’S TECHNICAL SPECIFICATIONS TRANSMITTER Equipment Type: [ ] Portable [ x ] Mobile [ x ] Base Station (fixed use) Intended Operating Environment: [ ] Residential [ x ] Commercial, light industry & heavy industry Power Supply Requirement: 13.8 Vdc nominal RF Output Power Rating: 1 Watt Operating Frequency Range: 902.2 - 927.8 MHz RF Output Impedance: 50 Ohms Channel Spacing: 200 kHz Duty Cycle: Continuous 20 dB Bandwidth: 118.6 kHz Modulation Type: CPFSK Channel Occupancy: 23 msec within 20 second period Emission Designation: Frequency Hopping Spread Spectrum Oscillator Frequency(ies): TCXO 16MHz, L.O. – 110.7MHz, 2 nd L.O. 100MHz Antenna Connector Type: Non-integral, Standard TNC connector (Professional Installation). Please refer to User Manual for detailed instruction of antenna installation and RF Exposure Warning. Antenna Description: Manufacturer: MDS ClearWave Antennas Type: Yagi P/N: 97-3662A13 Frequency Range: 890 – 960 MHz In/Out Impedance: 50 Ohms Gain: 4 dBd 3.4. LIST OF EUT’S PORTS Port Number EUT’s Port Description Number of Identical Ports Connector Type Cable Type (Shielded/Non-shielded) 1 LAN 1 RJ-45 Ethernet Non-Shielded 2 COM 1 DB9 Female Shielded 3 Antenna 1 TNC Shielded 4 Power 1 2 Pin Inline Non-Shielded

Test Setup Photos

ANNEX 2 - TEST SETUP PHOTOGRAPHS (Radiated Emissions at 3 Meters Distance) Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A2 - 1 ANNEX 2 - TEST SETUP PHOTOGRAPHS (Radiated Emissions at 3 Meters Distance) Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A2 - 2 ANNEX 2 - TEST SETUP PHOTOGRAPHS (Radiated Emissions at 3 Meters Distance) Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A2 - 3 ANNEX 2 - TEST SETUP PHOTOGRAPHS (Radiated Emissions at 3 Meters Distance) Microwave Data Systems Inc. TransNet, Model EL805 FCC ID: E5MDS-EL805 A2 - 4

Contact Information

Applicant

John Barenys(Senior Operations Manager)
[email protected]585-683-4254Fax: 585-241-5590

Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-765-4173

3000 Bristol Circle · Oakville, Ontario · Canada

Non-Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-765-4173

Test Firm

UltraTech Engineering Labs Inc.Tri Luu
[email protected]877-747-6381Fax: 905-829-8050

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.2 MHz - 927.8 MHz795.00 mW
Confidentiality
Long Term

Other Applications from GE MDS, LLC

Frequency Hopping Radio - FCC ID E5MDS-NET9S - GE MDS, LLC
E5MDS-NET9S

Frequency Hopping Radio

Jul 13, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Frequency Hopping Radio - FCC ID E5MDS-NET9L - GE MDS, LLC
E5MDS-NET9L

Frequency Hopping Radio

Jul 11, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Industrial Radio Module - FCC ID E5MDS-LN900 - GE MDS, LLC
E5MDS-LN900

Industrial Radio Module

Jan 27, 2016

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
MDS SDM4 Licensed Spectrum Module - FCC ID E5MDS-SDM4 - GE MDS, LLC
E5MDS-SDM4

MDS SDM4 Licensed Spectrum Module

Aug 20, 2015

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Industrial Radio Module - FCC ID E5MDS-LN400 - GE MDS, LLC
E5MDS-LN400

Industrial Radio Module

Jul 09, 2015

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter