FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nice North America LLC/
  3. EF400118

EF400118Security/Remote Control Transmitter

Nice North America LLC
Security/Remote Control Transmitter - FCC ID EF400118 - Nice North America LLC
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 04, 2014
Application Purpose
Original Equipment
Date of Application
Mar 03, 2014
Equipment Note
Security/Remote Control Transmitter
Frequency Range
345.00000000 - 345.00000000
Company
Nice North America LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GD00Z-1GARAGE DOOR OPENERREMOTE COMMANDCONTROLLERwith TILT SENSORInstallation Instructions 1. PRODUCT DESCRIPTIONThe Model GD00Z-1 is a garage door opener Remote Command Controller with built-in Z-Wave ® interoperable two-way RF mesh networking technology designed for use with Lowe’s Iris ® hub. A garage door opener connected to the Controller can be remotely activated using the Iris web interface or Iris mobile applications.The GD00Z-1 Controller connects to the garage door opener’s pushbutton wall console terminals and communicates with the Iris hub using Z-Wave radio signals. A wireless tilt sensor mounts on the garage door and reports the door’s position to the Controller. When the Controller receives a command from the Iris hub, it will open or close the garage door.Anytime the garage door opener is activated remotely by the Controller, a warning indicator fl ashes and a beeper sounds for fi ve seconds before the door begins to move.If, due to an obstruction or other cause, the door does not completely open or close when it is activated remotely, the Controller will pause for 30 seconds. After the delay, a second remote activation can be attempted. If the door does not complete its motion on the second attempt, the Controller will suspend operation until the door is operated locally with the opener’s pushbutton wall console.The Controller is powered by a plug-in power supply. The Model TILT 345 tilt sensor is powered by a 2032 lithium battery. If the tilt sensor battery is low, it will be reported to the Iris hub by the Controller. A link button and status light are provided on the Controller for adding or removing the device with the Iris hub.Four screws and anchors are provided for mounting the Controller. An adjustable controller mounting bracket with hardware is supplied for installing the unit onto the door opener’s hanging hardware. The wireless tilt sensor mounts with double sided tape or the two screws supplied. 2. SAFETY NOTES 3. PRODUCT FEATURES 4. TILT SENSOR INSTALLATION AND BATTERY 5. PAIRING WITH IRIS USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340 www.linearcorp.com PRINTER’S INSTRUCTIONS: INSTR,INSTL,GD00Z-1 - LINEAR P/N: 235686 X21 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1 - FOLDING: 2-FOLD ALTERNATE - SIDE 1 OF 2 WARNING This operator system is equipped with an unattended operation feature. This door could move unexpectedly. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR! WARNING This system can be installed on sectional type (roll up) doors only per (UL-325). DO NOT INSTALL ON ONE-PIECE DOORS! WARNING Do not install the Remote Command Controller on garage door operators manufactured prior to 1993 (models without an operational safety beam entrapment detection system). WARNING The Remote Command Controller must be mounted in the garage, in sight of the garage door, where the visual and audible movement warning indicators can be clearly seen and heard. Z-Wave ® is a registered trademark of Sigma Designs Inc. and/or its subsidiaries. CONTROLLER PO W ER I N PUT JACK W AR N I N G LIGHT LI N K BUTTO N CO N TROLLER CO NN ECTIO N W IRES DOUBLE SIDED MOU N TI N G TAPE, SCRE W S A N D A N CHORS POWER SUPPLY TILT SENSOR STATUS I N DICATOR ADJUSTABLE MOUNTING BRACKET (OPTIO N AL) POWER SUPPLY RETAINING BRACKET PARING THE CONTROLLER REMOVING THE CONTROLLER TO PAIR WITHTHE IRIS HUB TO REMOVE FROM THE IRIS HUB FROM THE IRIS W EB SITE, CLICK "DEVICES", THE N CLICK THE "ADD DEVICES" BUTTO N FOLLO W THE O N -SCREE N I N STRUCTIO N S TO PAIR THE CO N TROLLER W ITH THE HUB SELECT GARAGE DOORCO N TROLLER FROM THE LIST 1 2 3 124 FROM THE IRIS W EB SITE, CLICK "DEVICES" O N THE GARAGE DOOR CO N TROLLER DEVICE CLICK "MA N AGE", THE N CLICK "REMOVE" FOLLO W THE O N -SCREE N I N STRUCTIO N S TO U N -PAIR THE CO N TROLLER W ITH THE HUB 3 W ALL OUTLET PO W ER SUPPLY PO W ER I N PUT JACK LI N K BUTTO N CO N TROLLER W HE N I N STRUCTED, PRESS THE LI N K BUTTO N O N THE CO N TROLLER 4 W HE N I N STRUCTED, PRESS THE LI N K BUTTO N O N THE CO N TROLLER www.lowes.com/iris CR2032 PLUS SIDE UP !!! IRIS WILL NOTIFY YOU WHENTHE BATTERY IS LOW,REPLACE THE BATTERY WITHA TYPE CR2032 COIN CELL I N SERT THE BATTERYI N TO THE TRA N SMITTER TO OPE N THE CASE, T W IST A SMALL SCRE W DRIVER I N CASE SLOT SLOT ATTACH MOU N TI N G PLATE TO TOP PANEL OF THE DOOR USE DOUBLE SIDED TAPE OR THE T W O MOU N TI N G SCRE W S SUPPLIED (DRILL 1/16" PILOT HOLES IF REQUIRED) POST O N BOTTOM "UP" ARRO W S S N AP SE N SOR O N TO THE MOU N TI N G PLATE TO ACTIVATE THE TILT SENSOR, REMOVE THE BATTERY PROTECTION PULL STRIP ARROWS ON PLATE & SENSOR POINT UP 6. CONTROLLER MOUNTING 7. CONTROLLER CONNECTIONS 8. SYSTEM OPERATION 9. OPERATION NOTES1. The warning light will fl ash and the warning beeper will sound fi ve seconds before the door opener is activated. STAY CLEAR OF THE DOOR, AND DOOR OPENER. THEY ARE ABOUT TO MOVE! 2. If the door does not completely open or close after remote activation, the Controller will allow user to try to operate the door one more time. If the second attempt fails, the Controller will go into lock-out mode and blink the status indicator. See Note #3. 3. If the status indicator is blinking, the Controller is in lock-out mode and will not accept remote commands. Activate the door from the pushbutton wall console then check that the status indicator stops blinking. 10. TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION The Controller does not fl ash or beep when activated. No power to the Controller. 1. Make sure the power supply is plugged in securely to a live outlet. 2. Make sure the power cord is plugged in securely to the Controller. The Controller fl ashes and beeps when activated but the door does not move. Obstruction blocking the door or incorrect wiring. 1. Make sure that there are no obstacles preventing the door from moving. 2. Make sure that the Controller’s connection wires are connected to the proper ter…

Text truncated - open the document above for the full version.

Cover Letter(s)

LINEAR LLC 1950 CAMINO VIDA ROBLE, SUITE 150, CARLSBAD, CA 92008-6517 PHONE (760) 438-7000 ● (800) 421-1587 ● ENG. FAX (760) 438-7043 MAIL: P.O. BOX 9003 ● CARLSBAD, CA 92018-9003 22 January 2014 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification FCC ID#: EF400118 Authority to Act as Agent On our behalf, I appoint Alan Laudani of Nemko USA Inc., 2210 Faraday Ave, STE 150, Carlsbad, CA, USA to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in Federal Communication Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with Linear L:LC, 1950 Camino Vida Roble, Suite 150, Carlsbad, CA. 92008-6517, USA. This appointment is in effect until December 31, 2014. Sincerely, John W. Kuivinen, P.E. Regulatory Compliance Engineer

Cover Letter(s)

LINEAR LLC 1950 CAMINO VIDA ROBLE, SUITE 150, CARLSBAD, CA 92008-6517 PHONE (760) 438-7000 ● (800) 421-1587 ● ENG. FAX (760) 438-7043 MAIL: P.O. BOX 9003 ● CARLSBAD, CA 92018-9003 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Re: Request of Confidentiality for FCC ID: EF400118 Pursuant to Sections 0.457(d)(I)(ii) and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying as outlined below: NONE The Applicant understands that pursuant to Rule 0.457(d)(I)(ii), disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Dated this 22 Day of January 2014 Sincerely, John W. Kuivinen, P.E. Regulatory Compliance Engineer, Linear LLC

Cover Letter(s)

LINEAR LLC 1950 CAMINO VIDA ROBLE, SUITE 150, CARLSBAD, CA 92008-6517 PHONE (760) 438-7000 ● (800) 421-1587 ● ENG. FAX (760) 438-7043 MAIL: P.O. BOX 9003 ● CARLSBAD, CA 92018-9003 22 January 2014 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 IC: 1078A-00116 Model Number: GD00Z-1 FCC ID#: EF400116 IC: 1078A-00118 Model Number: TILT 345 FCC ID#: EF400118 The Tilt 345 is sold as part of a system with the GD00Z-1 controller. See installation instructions. Sincerely, John W. Kuivinen, P.E. Regulatory Compliance Engineer Linear LLC

ID Label/Location Info

LABEL,FCC,ID,LNRTLT01 LINEAR P/N: 236141 X4 MFG. PROCESS: PRINTED LABEL OR PAD PRINTING LABEL MATERIAL: 60 LB. WHITE COATED, ADHESIVE BACKED LABEL INK: PERMANENT BLACK, RoHS COMPLIANT PAD PRINTING INK: BLACK, LINEAR P/N 213337-002 SCALE: 1-1 Linear LLC Model: TILT 345 FCC ID: EF4 00118 IC: 1078A-00118 Made in China .750” .500”

Test Report

Nemko Test Report: 2014 1247315 FCC Applicant: Linear LLC 1950 Camino Vida Roble Carlsbad, CA 92008 USA Equipment Under Test: TILT 345 (E.U.T.) FCC Identifier: EF400118 Industry Canada Identifier: 1078A-00118 In Accordance With: FCC Part 15, Subpart C and Industry Canada RSS-210 Issue 8 For Low Power Transmitters Operating Periodically In The Band 40.66 - 40.77 MHz and Above 70 MHz Tested By: Nemko USA, Inc. 2210 Faraday Ave. Suite 150 Carlsbad, CA 92008 TESTED BY: DATE: 15 January 2014 David Light, Wireless Engineer APPROVED BY: DATE: Alan Laudani Senior RF/EMC Engineer Test Report Verificator 22 January 2014 Total Number of Pages: 19 Nemko USA, Inc. FCC Part 15, Subpart C and Industry Canada RSS-210 Issue 8 PERIODICALLY OPERATED LOW POWER TRANSMITTERS FCC ID: EF400118 IC: 1078A-00118 REPORT NO.:2014 1247315 FCC Page 2 of 18 TABLE OF CONTENTS SECTION 1. SUMMARY OF TEST RESULTS 3 SECTION 2. EQUIPMENT UNDER TEST (E.U.T.) 5 SECTION 3. TRANSMISSION REQUIREMENTS 6 SECTION 4. RADIATED EMISSIONS 8 SECTION 5. OCCUPIED BANDWIDTH 12 SECTION 6. BLOCK DIAGRAMS 15 ANNEX A - RESTRICTED BANDS 17 Nemko USA, Inc. FCC Part 15, Subpart C and Industry Canada RSS-210 Issue 8 PERIODICALLY OPERATED LOW POWER TRANSMITTERS FCC ID: EF400118 IC: 1078A-00118 REPORT NO.:2014 1247315 FCC Page 3 of 18 Section 1. Summary of Test Results Manufacturer: Linear Corporation Model No.: Tilt 345 General: All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15, Subpart C, Paragraph 15.231 and Industry Canada RSS-210 Issue 8. All tests were conducted using measurement procedure ANSI C63.4-2003. Radiated emissions are made on an open area test site. A description of the test facility is on file with the FCC and Industry Canada. New Submission Production Unit Class II Permissive Change Pre-Production Unit THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. See “ Summary of Test Data”. NVLAP Lab Code 200116-0 This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Nemko USA, Inc. is a NVLAP accredited laboratory. Nemko USA Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko USA Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. Nemko USA, Inc. FCC Part 15, Subpart C and Industry Canada RSS-210 Issue 8 PERIODICALLY OPERATED LOW POWER TRANSMITTERS FCC ID: EF400118 IC: 1078A-00118 REPORT NO.:2014 1247315 FCC Page 4 of 18 Summary Of Test Data Name of Test Paragraph No. Results Transmission Requirements 15.231(a) / A1.1.1 Complies Radiated Emissions 15.231(b) / A1.1 Complies Occupied Bandwidth 15.231(c) / A1.1.3 Complies Frequency Tolerance 15.231(d) / A1.1.4 NA Alternate Field Strength Requirements 15.231(e) / A1.1.5 NA Powerline Conducted Emissions 15.207 / RSS-Gen 7.2.4 NA Receiver Spurious Emissions RSS-Gen 6.1 NA Footnotes: 1) The device does not operate between 40.66 to 40.70 MHz 2) The device is battery powered. 3) The device is not a receiver. Nemko USA, Inc. FCC Part 15, Subpart C and Industry Canada RSS-210 Issue 8 PERIODICALLY OPERATED LOW POWER TRANSMITTERS FCC ID: EF400118 IC: 1078A-00118 REPORT NO.:2014 1247315 FCC Page 5 of 18 Section 2. Equipment Under Test (E.U.T.) General Equipment Information Frequency Range: 345.0 MHz Operating Frequency(ies) of Sample: 345.0 MHz Type of Emission: ASK Supply Power Requirement: 3 Vdc battery (Lithium Ion battery) Antenna Requirement: Antenna fixed wire on PCB Description of E.U.T. The tilt sensor TILT 345 is a low power wireless entry detection device which operates on a single fixed frequency of 345 MHz. The device operates from a single 3V lithium battery. Nemko USA, Inc. FCC Part 15, Subpart C and Industry Canada RSS-210 Issue 8 PERIODICALLY OPERATED LOW POWER TRANSMITTERS FCC ID: EF400118 IC: 1078A-00118 REPORT NO.:2014 1247315 FCC Page 6 of 18 Section 3. Transmission Requirements NAME OF TEST: Transmission Requirements PARA. NO.: FCC 15.231(a) RSS-210 A1.1.1 TESTED BY: David Light DATE: 16 December 2013 Minimum Standard: 15.231(a) Continuous transmissions such as voice, video or data transmissions are not permitted. 15.231(a)(1) / A1.1.1(a) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds after being released. 15.231(a)(2) / A1.1.1(b) A transmitter activated automatically shall cease transmission within 5 seconds of activation. 15.231(a)(3) / A1.1.1(c) Periodic transmissions at regular pre-determined intervals are not permitted. However polling or supervisory transmissions to determine system integrity of transmitters used in security or safety applications are allowed if the periodic rate of transmission does not exceed one transmission of not more than one second duration per hour for each transmitter. 15.231(a)(4) /A1.1.1(d) Intentional radiators which are employed for radio control purposes during emergencies involving fire, security, and safety of life, when activated to signal an alarm, may operate during the pendency of the alarm. Test Results: Complies. Test Data: Compliance was determined by verification of technical specifications and a functional test on the equipment. Nemko USA, Inc. FCC Part 15, Subpart C and Industry Canada RSS-210 Issue 8 PERIODICALLY OPERATED LOW POWER TRANSMITTERS FCC ID: EF400118 IC: 1078A-00118 REPORT NO.:2014 1247315 FCC Page 7 of 18 Rationale for Compliance with Transmi…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Josh Hansen(Engineering Manager, Regulatory & Compliance)
[email protected]800-421-1587Fax: 760-438-7043

Technical Contact

Linear LLCJohn William Kuivinen
[email protected]

1950 Camino Vida Roble, Suite 150 · Carlsbad · United States

Test Firm

Nemko USA, Inc. - San Diego EMC DivisionJan Blomgren
[email protected]760-444-3500

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231345 MHz - 345 MHz-

Other Applications from Nice North America LLC

EF400267

Edge II Security Panel

May 19, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
EF400266

Wireless KVM Extender TX+RX

Mar 12, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
EF400265

Wireless KVM Extender TX+RX

Mar 12, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
EF4-FGS223US

DoubleDimmer-Control

Dec 18, 2025

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
EF400247

Digital Transmitter

Jul 01, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter