EMOIBT100APortable Bluetooth Candle Speaker

SDI Technologies Inc.
Portable Bluetooth Candle Speaker - FCC ID EMOIBT100A - SDI Technologies Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 12, 2024
Application Purpose
Original Equipment
Date of Application
Jun 12, 2024
Equipment Note
Portable Bluetooth Candle Speaker
Frequency Range
2402.00000000 - 2480.00000000
Company
SDI Technologies Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev1/26/2023 (SDITechnologiesInc.) EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 USA Date:2024.06.04 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:EMOIBT100A [SDITechnologiesInc.](“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtis not“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection 2.903oftheFCCrules. Sincerely, (Applicantsignature) (DavidStetin) Rev1/26/2023 (SDITechnologiesInc.) EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 USA Date:2024.06.04 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:EMOIBT100A [SDITechnologiesInc.](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesor affiliates)asanentityproducing“covered” equipment. Sincerely, (Applicantsignature) (DavidStetin)

Attestation Statements

SDITechnologiesInc. AttestationStatements Jun04,2024 TO:FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046,USA RE:AttestationStatementsPart2.911(d)(7)requestforFCCID:EMOIBT100A SDITechnologiesInc.,theundersigned,herebyauthorizeSDITechnologiesInc.toactas ourdesignatedU.S.agentforserviceofprocess,SDITechnologiesInc.acceptsto maintainanagentfornolessthanoneyearafterthegranteehasterminatedall marketingandimportationortheconclusionofanyCommission-relatedproceeding involvingtheequipment. SDITechnologiesInc.acceptstheresponsibilitytoactasdesignatedU.S.agentfor serviceofprocess,providesanagentfornolessthanoneyearafterthegranteehas terminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipment. ApplicantInformation: Companyname:SDITechnologiesInc. ContactName:DavidStetin Address:1299,MainStreet,Rahway,NJ07065,U.S.A. TelephoneNo:732574-9000 Email:[email protected] U.S.AgentInformation: CompanyName:SDITechnologiesInc. ContactName:DavidStetin Address:1299,MainStreet,Rahway,NJ07065,U.S.A. TelephoneNo:732574-9000 Email:[email protected] FRN:0003786449 ApplicantSignature:AgentSignature: (iftheagentisdifferentfromtheapplicant) Applicantprintedname:DavidStetinAgentprintedname:DavidStetin

Cover Letter(s)

SDITechnologiesInc. Declarationonmodeldifference Wetheundersignedherebyconfirmthatthesemodelsareidentical,andallmodelshavethesame RFmodule,PCBlayout,Antenna,schematicsandcomponent.Onlydifferentonmodel number,yearversion,buyersandcolor. ProductionnameTrademarkFCCModelno. PortableBluetooth CandleSpeaker iHomeEMOIBT100AiBT100,iBT100X(Xcould besingleormultipledigits byanyalphabetsand punctuationmarks denotingdifferentcabinet colors,yearversionsand clients) Confirmedby: DavidStetin SDITechnologiesInc. 2024.06.04

Cover Letter(s)

SDITechnologiesInc. 2024.06.04 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:CONFIDENTIALITYREQUESTFOR( ProductName:PortableBluetoothCandleSpeaker ModelNumber : iBT100,iBT100X(Xcouldbesingleormultiple digitsbyanyalphabetsandpunctuationmarks denotingdifferentcabinetcolors,year versionsandclients) FCCID:EMOIBT100A Applicant:SDITechnologiesInc. Address:1299MainStreet,Rahway,NJ07065,U.S.A ) ToWhomItMayConcern: Thisletterservesasanofficialrequestforconfidentialityundersections0.457and0.459 ofCFR47.Wehaverequestedthatthe(BlockDiagram,Schematics,Operational Description)requiredtobesubmittedwiththisapplicationbepermanentlywithheld frompublicreview. SPECIFYREASONFORREQUEST(Theabovematerialscontaintradesecrets andproprietaryinformationnotcustomarilyreleasedtothepublic.Thepublic disclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors.) Pleasecontactmeifthereisanyinformationyoumayneed. Sincerely, DavidStetin Mustbesignedbytheapplicantcontactcitedastechnicalornon-technicalcontactonthe 731formprovidedtoEurofinsMETLabs,orbytheauthorizedagentifanappropriate authorizedagentletterhasbeenprovided.Letterssignedbytheapplicantshouldbe placedonapplicantletterhead.

Cover Letter(s)

SDITechnologiesInc. 2024.06.04 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorizeSamLvatEMTEK(DONGGUAN)CO.,LTD.toacton ourbehalfinallmattersrelatingtoapplicationforequipmentauthorization,includingthesigning ofalldocumentsrelatingtothesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderissubjecttothe denialofbenefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseAct of1988,21U.S.C.853(a). Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, DavidStetin Mustbesignedbytheapplicantcontactcitedastechnicalornon-technicalcontactonthe 731formprovidedtoEurofinsMETLabs,orbytheauthorizedagentifanappropriate authorizedagentletterhasbeenprovided.Letterssignedbytheapplicantshouldbe placedonapplicantletterhead.

External Photos

ReportNo.EDG2405070234E004Page1of3Ver.1.0 FCCID:EMOIBT100A ReportNo.EDG2405070234E004Page2of3Ver.1.0 ReportNo.EDG2405070234E004Page3of3Ver.1.0

Internal Photos

ReportNo.EDG2405070234E004Page1of3Ver.1.0 FCCID:EMOIBT100A ReportNo.EDG2405070234E004Page2of3Ver.1.0 BTANT ReportNo.EDG2405070234E004Page3of3Ver.1.0

RF Exposure Info

ReportNo.EDG2405070234E00402RPage1of7Ver.1.0 TESTREPORT ProductName:PortableBluetoothCandleSpeaker ModelNumber: iBT100,iBT100X(Xcouldbesingleor multipledigitsbyanyalphabetsand punctuationmarksdenotingdifferentcabinet colors,yearversionsandclients) FCCID:EMOIBT100A Preparedfor:SDITechnologiesInc. Address:1299MainStreet,Rahway,NJ07065,U.S.A Preparedby:EMTEK(DONGGUAN)CO.,LTD. Address:-1&2/F.,Building2,ZoneA,ZhongdaMarineBiotechnology ResearchandDevelopmentBase,No.9,XinchengAvenue, SongshanhuHigh-technologyIndustrialDevelopmentZone, Dongguan,Guangdong,China TEL:+86-0769-22807078 FAX:+86-0769-22807079 ReportNumber:EDG2405070234E00402R Date(s)ofTests:May07,2024toMay21,2024 Dateofissue:May22,2024 $二维码$ ReportNo.EDG2405070234E00402RPage2of7Ver.1.0 TableofContents 1.TESTRESULTCERTIFICATION...............................................................................................................................................3 2.EUTSPECIFICATION.................................................................................................................................................................5 3.TESTREQUIREMENT................................................................................................................................................................6 4.MEASUREMENTRESULT.........................................................................................................................................................6 ReportNo.EDG2405070234E00402RPage3of7Ver.1.0 1.TESTRESULTCERTIFICATION Applicant:SDITechnologiesInc. Address:1299MainStreet,Rahway,NJ07065,U.S.A Manufacturer:eKids,LLC./KIDDESIGNSINC. Address:1299MainStreet,Rahway,NJ07065,U.S.A Factory:DongshunTechDevelopmentLimited Address: 2F,building7,HuayishengIndustrialPark,FenghuangCommunity,Fuyong Street,Bao'andistrict,Shenzhen,China EUT:PortableBluetoothCandleSpeaker ModelName: iBT100,iBT100X(Xcouldbesingleormultipledigitsbyanyalphabetsand punctuationmarksdenotingdifferentcabinetcolors,yearversionsandclients) Trademark:iHome MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT §15.247(i),§2.1093 PASS TheaboveequipmentwastestedbyEMTEK(DONGGUAN)CO.,LTD.Thetestdata,dataevaluation,test procedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththeprocedures giveninANSIC63.10(2013)andtheenergyemittedbythesampleEUTtestedasdescribedinthisreportisin compliancewiththerequirementsofFCCRules FCC§15.247(i),§2.1093 . Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport DateofTest: May07,2024toMay21,2024 Preparedby: WarrenDeng/ Editor Reviewer: TimDong/ Supervisor Approve&AuthorizedSigner: SamLv/Manager ReportNo.EDG2405070234E00402RPage4of7Ver.1.0 ModifiedHistory VersionReportNo.RevisionDateSummary EDG2405070234E00402R/OriginalReport ReportNo.EDG2405070234E00402RPage5of7Ver.1.0 2. EUTSpecification CharacteristicsDescription Product:PortableBluetoothCandleSpeaker ModelNumber: iBT100,iBT100X(Xcouldbesingleormultipledigitsbyanyalphabetsand punctuationmarksdenotingdifferentcabinetcolors,yearversionsand clients) Allproductsarethesame,onlythemodelnumber,yearversion,buyersand coloraredifferent.HereweselectediBT100forallthetest. Sample:1# DataRate: 1MbpsforGFSKmodulation 2Mbpsforπ/4-DQPSKmodulation 3Mbpsfor8DPSKmodulation Modulation: GFSK,π/4-DQPSK,8DPSK OperatingFrequency Range(s): 2402-2480MHz NumberofChannels: 79channels TransmitPowerMax: 0.63dBm(0.001156W) AntennaGain:-0.60dBi Powersupply: DC5VfromUSB DC3.7Vfrombattery Evaluationapplied:MPEEvaluation SAREvaluation ReportNo.EDG2405070234E00402RPage6of7Ver.1.0 3. TestRequirement SAREvaluation Accordingto447498D01V06,systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannerthatensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission’sguidelines. RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,usingmeasurementsorcomputer simulation.WhenroutineSARevaluationisnotrequired,portabletransmitterswithoutputpowergreaterthan theapplicablelowthresholdrequireSARevaluationtoqualityforTCBapproval. OneantennaisavailablefortheEUT.Theminimumseparationdistanceis5mm. ReportNo.EDG2405070234E00402RPage7of7Ver.1.0 4. MeasurementResult Antennagain:-0.60dBi Transmit Frequency (MHz) Mode Measured Power (dBm) Tune upPower (dBm) Maxtuneup power (dBm) Calculation Result 1-gSAR 2402GFSK-0.99-1±100.31003 2441GFSK-0.420±110.39343 2480GFSK-0.470±110.39653 2402Π/4-DQPSK-0.340±110.39023 2441Π/4-DQPSK0.200±110.39343 2480Π/4-DQPSK0.210±110.39653 24028DPSK-0.060±110.39023 24418DPSK0.510±110.39343 24808DPSK0.631±120.49923 AccordingtoKDB447498D01V06,nostand-alonerequiredforBTantenna,andnosimultaneousSAR measurementisrequired. ***EndofReport***

Test Report

InvertedFAntennaSpecification Summary ITEM ANTSPEC ModelName 2.4GANT Center Frequency HorizontalVertical 2400MHz2450MHz2500MHz2400MHz2450MHz2500MHz -1.26-0.76-0.6-5.25-2.46-1.86 MAX.Gain -0.6dBi PolarizationHorizontalandVertical AzimuthBeam Pattern Omni-directional Impedance 15.2Ohm AntennaLength 5.7mm Manufacture:Shenzhen hua zicheng Technology Co., LTD. 3 / F, Building 9, Longwangmiao Industrial Zone, Baishixia Community, Fuyong Street, Baoan District, Shenzhen Horizontal:2400MHz2450MHz2500MHz Power(dBm) Max:0Min:-40Scale:5/div Frequency (MHz) Gain(dBi) MaxMin Avg 2400-1.26174-30.0801-718716 2450-0.765802-36.5604-7.48023 2500-0.585582-22.0315-6.59127 Vertical:2400MHz2450MHz2500MHz Power(dBm) Max:0Min:-30Scale:5/div Frequency (MHz) Gain(dBi) MaxMin Avg 2400-5.2537 -22.1424-12.4294 2450-2.4652-24.5837-10.4702 2500-1.86120-29.5214-9.20432

Test Report

ReportNo.EDG2405070234E00401RPage1of71Ver.1.0 TESTREPORT ProductName:PortableBluetoothCandleSpeaker ModelNumber: iBT100,iBT100X(Xcouldbesingleor multipledigitsbyanyalphabetsand punctuationmarksdenotingdifferentcabinet colors,yearversionsandclients) FCCID:EMOIBT100A Preparedfor:SDITechnologiesInc. Address:1299MainStreet,Rahway,NJ07065,U.S.A Preparedby:EMTEK(DONGGUAN)CO.,LTD. Address:-1&2/F.,Building2,ZoneA,ZhongdaMarineBiotechnology ResearchandDevelopmentBase,No.9,XinchengAvenue, SongshanhuHigh-technologyIndustrialDevelopmentZone, Dongguan,Guangdong,China TEL:+86-0769-22807078 FAX:+86-0769-22807079 ReportNumber:EDG2405070234E00401R Date(s)ofTests:May07,2024toMay21,2024 Dateofissue:May22,2024 ReportNo.EDG2405070234E00401RPage2of71Ver.1.0 TableofContents 1TESTRESULTCERTIFICATION..................................................................................................................................................3 2EUTTECHNICALDESCRIPTION.................................................................................................................................................5 3SUMMARYOFTESTRESULT.....................................................................................................................................................6 4TESTMETHODOLOGY.................................................................................................................................................................7 4.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS......................................................................................................7 4.2MEASUREMENTEQUIPMENTUSED..................................................................................................................................7 4.3DESCRIPTIONOFTESTMODES..........................................................................................................................................8 5FACILITIESANDACCREDITATIONS........................................................................................................................................9 5.1FACILITIES..............................................................................................................................................................................9 5.2EQUIPMENT............................................................................................................................................................................9 5.3LABORATORYACCREDITATIONSANDLISTINGS.........................................................................................................9 6TESTSYSTEMUNCERTAINTY.................................................................................................................................................10 7SETUPOFEQUIPMENTUNDERTEST.....................................................................................................................................11 7.1RADIOFREQUENCYTESTSETUP1.................................................................................................................................11 7.2RADIOFREQUENCYTESTSETUP2.................................................................................................................................11 7.3CONDUCTEDEMISSIONTESTSETUP.............................................................................................................................13 7.4BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM.............................................................................................14 7.5SUPPORTEQUIPMENT........................................................................................................................................................14 8FREQUENCYHOPPINGSYSTEMREQUIREMENTS...............................................................................................................15 8.1StandardApplicable.................................................................................................................................................................15 8.2EUTPseudorandomFrequencyHoppingSequence................................................................................................................15 8.3EqualHoppingFrequencyUse................................................................................................................................................16 8.4FrequencyHoppingSystem.....................................................................................................................................................16 9TESTREQUIREMENTS...............................................................................................................................................................17 9.120DB&99%BANDWIDTH.....................................................................................................................................................17 9.2CARRIERFREQUENCYSEPARATION..............................................................................................................................29 9.3NUMBEROFHOPPINGFREQUENCIES............................................................................................................................32 9.4AVERAGETIMEOFOCCUPANCY(DWELLTIME)........................................................................................................35 9.5MAXIMUMPEAKCONDUCTEDOUTPUTPOWER.........................................................................................................41 9.6CONDUCTEDSUPRIOUSEMISSION.................................................................................................................................47 9.7RADIATEDSPURIOUSEMISSION.....................................................................................................................................57 9.8CONDUCTEDEMISSIONTEST........................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

ReportNo.EDG2405070234E00401RPage41of71Ver.1.0 9.5MAXIMUMPEAKCONDUCTEDOUTPUTPOWER 9.5.1ApplicableStandard AccordingtoFCCPart15.247(b)(1)andKDB558074D0115.247MEASGUIDANCEv05r02 AccordingtoICRSS-247.5.4andRSS-Gen6.12 9.5.2ConformanceLimit ThemaxForfrequencyhoppingsystemsoperatinginthe2400-2483.5MHzbandemployingatleast75 non-overlappinghoppingchannels:1watt.Forallotherfrequencyhoppingsystemsinthe2400-2483.5MHzband: 0.125watts. 9.5.3TestConfiguration Testaccordingtoclause7.1radiofrequencytestsetup1 9.5.4TestProcedure Asanalternativetoapeakpowermeasurement,compliancewiththelimitcanbebasedonameasurementofthe maximumconductedoutputpower. Usethefollowingspectrumanalyzersettings: SetSpan=approximately5timesthe20dBbandwidth,centeredonahoppingchannel(about8MHz) SetRBW>the20dBbandwidthoftheemissionbeingmeasured(about3MHz) SetVBW  RBW SetSweep=auto SetDetectorfunction=peak SetTrace=maxhold Allowthetracetostabilize.Usethemarker-to-peakfunctiontosetthemarkertothepeakoftheemissionto determinethepeakamplitudelevel. TestResults Temperature: 25 ̊C RelativeHumidity:45% ATMPressure:1011mbar Note:N/A Test Mode AntennaFrequency[MHz] ConductedPeak Powert[dBm] Conducted Limit[dBm] Verdict DH5Ant12402-0.99≤20.97PASS DH5Ant12441-0.42≤20.97PASS DH5Ant12480-0.47≤20.97PASS 2DH5Ant12402-0.34≤20.97PASS 2DH5Ant124410.20≤20.97PASS 2DH5Ant124800.21≤20.97PASS 3DH5Ant12402-0.06≤20.97PASS 3DH5Ant124410.51≤20.97PASS 3DH5Ant124800.63≤20.97PASS ReportNo.EDG2405070234E00401RPage42of71Ver.1.0 DH5-Ant1-2402-PASS DH5-Ant1-2441-PASS ReportNo.EDG2405070234E00401RPage43of71Ver.1.0 DH5-Ant1-2480-PASS 2DH5-Ant1-2402-PASS ReportNo.EDG2405070234E00401RPage44of71Ver.1.0 2DH5-Ant1-2441-PASS 2DH5-Ant1-2480-PASS ReportNo.EDG2405070234E00401RPage45of71Ver.1.0 3DH5-Ant1-2402-PASS 3DH5-Ant1-2441-PASS ReportNo.EDG2405070234E00401RPage46of71Ver.1.0 3DH5-Ant1-2480-PASS ReportNo.EDG2405070234E00401RPage47of71Ver.1.0 9.6CONDUCTEDSUPRIOUSEMISSION 9.6.1ApplicableStandard AccordingtoFCCPart15.247(d)andKDB558074D0115.247MEASGUIDANCEv05r02 AccordingtoICRSS-2475.5 9.6.2ConformanceLimit Inany100kHzbandwidthoutsidethefrequencybandinwhichthespreadspectrumintentionalradiatoris operating,theradiofrequencypowerthatisproducedbytheintentionalradiatorshallbeatleast20dBbelowthat inthe100kHzbandwidthwithinthebandthatcontainsthehighestlevelofthedesiredpower,basedoneitheran RFconducted,providedthetransmitterdemonstratescompliancewiththepeakconductedpowerlimits. 9.6.3TestConfiguration Testaccordingtoclause7.1radiofrequencytestsetup1 9.6.4TestProcedure Thetransmitteroutput(antennaport)wasconnectedtothespectrumanalyzer Referencelevelmeasurement Establishareferencelevelbyusingthefollowingprocedure: SetinstrumentcenterfrequencytoDSSchannelcenterfrequency. SetSpan=approximately5timesthe20dBbandwidth,centeredonahoppingchannel. SettheRBW=100kHz.SettheVBW≥3xRBW. SetDetector=peak.SetSweeptime=autocouple. SetTracemode=maxhold.Allowtracetofullystabilize. UsethepeakmarkerfunctiontodeterminethemaximumMaximumconducetedlevel. Notethatthechannelfoundtocontainthemaximumconducetedlevelcanbeusedtoestablishthereference level. Band-edgemeasurement Usethefollowingspectrumanalyzersettings: Span=wideenoughtocapturethepeakleveloftheemissionoperatingonthechannelclosesttotheband-edge, aswellasanymodulationproductswhichfalloutsideoftheauthorizedbandofoperation SetRBW  1%ofthespan=100kHzSetVBW  3xRBW SetSweep=autoSetDetectorfunction=peakSetTrace=maxhold Allowthetracetostabilize.Setthemarkerontheemissionatthebandedge,oronthehighestmodulation productoutsideoftheband,ifthislevelisgreaterthanthatatthebandedge.Enablethemarker-deltafunction, thenusethemarker-to-peakfunctiontomovethemarkertothepeakofthein-bandemission.Themarker-delta valuenowdisplayedmustcomplywiththelimitspecifiedinthisSection. Now,usingthesameinstrumentsettings,enablethehoppingfunctionoftheEUT.Allowthetracetostabilize. Followthesameprocedurelistedabovetodetermineifanyspuriousemissionscausedbythehoppingfunction alsocomplywiththespecifiedlimit. Emissionlevelmeasurement Usethefollowingspectrumanalyzersettings: Span=wideenoughtocapturethepeaklevelofthein-bandemissionandallspuriousemissions(e.g.,harmonics) fromthelowestfrequencygeneratedintheEUTupthroughthe10thharmonic.(30MHzto25GHz).SetRBW= 100kHzSetVBW  RBW SetSweep=autoSetDetectorfunction=peakSetTrace=maxhold Allowthetracetostabilize.Setthemarkeronthepeakofanyspuriousemissionrecorded.Theleveldisplayed mustcomplywiththelimitspecifiedinthisSection. ReportNo.EDG2405070234E00401RPage48of71Ver.1.0 9.6.5TestResults Temperature: 25 ̊ C RelativeHumidity:45% ATMPressure:1011mbar Note:N/A Alltheantennaandmodesmodehavebeentested,andtheworstresultrecordedwasreportasbelow: Bandedgemeasurements TestModeAntennaChNameFrequency[MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1Low2402-1.87-41.67≤-21.87PASS DH5Ant1High2480-1.74-46.44≤-21.74PASS DH5Ant1LowHop_2402-2.51-41.95≤-22.51PASS DH5Ant1HighHop_2480-1.16-44.48≤-21.16PASS ReportNo.EDG2405070234E00401RPage49of71Ver.1.0 DH5-Ant1-2402-PASS DH5-Ant1-2480-PASS ReportNo.EDG2405070234E00401RPage50of71Ver.1.0 DH5-Ant1-Hop_2402-PASS DH5-Ant1-Hop_2480-PASS ReportNo.EDG2405070234E00401RPage51of71Ver.1.0 ConductedSpuriousEmission TestModeAntennaFrequency[MHz] FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant124020~Reference-1.99-1.99---PASS DH5Ant1240230~1000-1.99-60.34≤-21.99PASS DH5Ant124021000~26500-1.99-50.13≤-21.99PASS DH5Ant124410~Reference-1.75-1.75---PASS DH5Ant1244130~1000-1.75-60.48≤-21.75PASS DH5Ant124411000~26500-1.75-50.5≤-21.75PASS DH5Ant124800~Reference-1.39-1.39---PASS DH5Ant1248030~1000-1.39-59.08≤-21.39PASS DH5Ant124801000~26500-1.39-47.98≤-21.39PASS ReportNo.EDG2405070234E00401RPage52of71Ver.1.0 DH5-Ant1-2402-0~Reference-PASS DH5-Ant1-2402-30~1000-PASS ReportNo.EDG2405070234E00401RPage53of71Ver.1.0 DH5-Ant1-2402-1000~26500-PASS DH5-Ant1-2441-0~Reference-PASS ReportNo.EDG2405070234E00401RPage54of71Ver.1.0 DH5-Ant1-2441-30~1000-PASS DH5-Ant1-2441-1000~26500-PASS ReportNo.EDG2405070234E00401RPage55of71Ver.1.0 D…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.EDG2405070234E004Page1of2Ver.1.0 FCCID:EMOIBT100A ReportNo.EDG2405070234E004Page2of2Ver.1.0

Contact Information

Applicant

David Stetin(Compliance Officer)
[email protected]732 574-9000Fax: 732 574-2634

Test Firm

EMTEK (Dongguan) Co., Ltd.Sam Lv
[email protected]886-0769-22807078

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.16 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

Other Applications from SDI Technologies Inc.

Magnetic Wallet Power Bank - FCC ID EMOIPCV3A - SDI Technologies Inc.
EMOIPCV3A

Magnetic Wallet Power Bank

May 27, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
ALARM CLOCK WITH NIGHTLIGHT AND FAST WIRELESS CHARGING - FCC ID EMOTW502A - SDI Technologies Inc.
EMOTW502A

ALARM CLOCK WITH NIGHTLIGHT AND FAST WIRELESS CHARGING

Apr 22, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Bluetooth Karaoke - FCC ID EMO555B - SDI Technologies Inc.
EMO555B

Bluetooth Karaoke

Nov 23, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Karaoke - FCC ID EMO555BM - SDI Technologies Inc.
EMO555BM

Bluetooth Karaoke

Nov 23, 2025

Equipment Class

DTS - Digital Transmission System
Bluetooth Alarm Clock with wireless and USB charging - FCC ID EMOIBTW112A - SDI Technologies Inc.
EMOIBTW112A

Bluetooth Alarm Clock with wireless and USB charging

Sep 07, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter