FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SDI Technologies Inc./
  3. EMOIZBT110A

EMOIZBT110APortable Meditative Light & Sound Therapy Candle

SDI Technologies Inc.
Portable Meditative Light & Sound Therapy Candle - FCC ID EMOIZBT110A - SDI Technologies Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 23, 2020
Application Purpose
Original Equipment
Date of Application
Jun 23, 2020
Equipment Note
Portable Meditative Light & Sound Therapy Candle
Frequency Range
2402.00000000 - 2480.00000000
Company
SDI Technologies Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

- Press the Power Button to turn the unit ON. - Press and hold the Bluetooth Pairing Button until the blue LED flashes to enter pairing mode. - Select ‘iHome iZBT110’ on your device’s Bluetooth menu to connect. USING LIGHT THERAPY Color light therapy can enhance the home through ambient or night-time lighting to help improve mood, energy and sleep. 1. Press the Light Therapy Button to access Light Therapy mode. Continue to press as needed to cycle to each mode, including OFF: Candle: Provides the ambiance of a calming candle flicker without the safety risks posed by a real flame Nightlight: Deal for illuminating a small space Glow: A gentle fading spectrum of solid colors creates a beautiful atmosphere for day or night mood lighting One Color: Select the current color Pulse: Light pulses to Bluetooth audio ADJUSTING THE BRIGHTNESS When you turn on Light Therapy or change a light mode, press the - or + Buttons within 5 seconds to adjust the brightness level. Press and hold the Light Therapy Button for 2 seconds to exit light therapy mode. Press the Light Therapy Button again to resume mode at the last light pattern used. USING SOUND THERAPY Sound Therapy uses specially recorded and engineered sounds to cancel out distractions and allow your mind to calm. 1. Press the Sound Therapy Button to access Sound Therapy mode. Continue to press to cycle to each mode: Sound Therapy Modes: 4-7-8 Breathing Coach Zen Dream Peace Meditation Trance Ocean Storm Nature River Wind Chimes Air Focus Quiet Drive O USING THE SLEEP TIMER The programmable timer mode lets you set any combination of light and sound therapy for a set duration. The light and sound levels will gradually decrease over the last 15 minutes (fade begins right away if timer is set to 10 minutes or less) until the unit shuts o. Press the Sleep Timer Button as needed to cycle to the desired timer duration: 10 minutes, 30 minutes, 1 hour, 2 hours, 4 hours, 6 hours, 8 hours, or OFF. Timer mode is first indicated by a voice guide and the Timer LED next to the Timer button. Green indicates more than 60 minutes remaining, yellow indicates 30 minutes or less remaining and red indicates 10 minutes or less remaining. Press and hold the Timer Button for 2 seconds to cancel timer mode. Timer mode is inactive when no timer indicator is lit. CONNECTING + PLAYING BLUETOOTH AUDIO Stream Bluetooth audio through the speaker in the unit: 1. Press and hold the Bluetooth Pairing Button to enter pairing mode. The Bluetooth LED will flash. 2. Select ‘iHome iZBT110’ on your Bluetooth device to connect. 3. The Bluetooth LED will glow solid to confirm a device is connected. 4. Use the controls on your device to Play, Pause, and navigate tracks. 5. Use the + and - Buttons on the unit to control volume. RESETTING THE UNIT In the event of interrupted operation, use the extended tip of a paper clip or other thin tool to press in the Reset Button pinhole located on the back of the unit. MAINTENANCE • Place the unit on a level surface away from sources of direct sunlight or excessive heat. • Protect your furniture when placing your unit on a natural wood and lacquered finish. A cloth or other protective material should be placed between it and the furniture. • Clean your unit with a soft cloth moistened only with mild soap and water. Stronger cleaning agents such as thinner or similar materials can damage the surface of the unit. WARNING/DISPOSAL OF UNIT Do NOT attempt to change the battery. Doing so will void the warranty and could cause injury and damage to your device. To dispose of the unit, follow the instructions below: • Never dispose of used batteries/electronics with ordinary solid wastes, since they contain toxic substances. • Always dispose of used batteries/electronics in accordance with the prevailing community regulations. • Many electronics retailers now recycle batteries and other electronic components at no charge FCC Information This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device complies with Part 15 of the FCC Rules, operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. • NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. ISEDC Statement This equipment complies with ISEDC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the fol…

Text truncated - open the document above for the full version.

Attestation Statements

SDI Technologies Inc. Address: 1299 Main St. Rahway, NJ 07065, United States Email: [email protected] Tel: 732 5749000‐ Fax: 735 5742634‐ Date: 2020/06/11 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: The RF chip, model ATS2819S, which installed in our product Portable Meditative Light & Sound Therapy Candle, Model: iZBT110, FCC ID: EMOIZBT110A, supports BDR (GFSK), EDR (π/4-DQPSK, 8DPSK), and BLE functions. For use in America and this chip will not support/enable BLE. The BLE function has been shielded by the manufacturer using the software. Sincerely Yours, Signature: David Stetin Compliance Officer

Cover Letter(s)

SDI Technologies Inc. ADD: 1299 Main St. Rahway NJ 07065, United States Tel: 732 574-9000 Fax: 732 574-2634 Email: [email protected] Product Similarity Declaration 2020-05-12 To Whom It May Concern, We, SDI Technologies Inc., hereby declare that we have a product named as Portable Meditative Light & Sound Therapy Candle (Model number: iZBT110) (FCC ID: EMOIZBT110A) was tested by BACL, meanwhile, for our marketing purpose, we would like to list series models (iZBT110WFT, iZBT110X (where X would be any 1 to 3 alphabets combination denote the color/type of cabinet)) on reports and certificate, all the models are electrically identical. The only difference is the color and model name. No other changes are made to them. We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact me if you have any question. Sincerely Yours, Signature: David Stetin Compliance Officer

Cover Letter(s)

SDI Technologies Inc. ADD: 1299 Main St. Rahway NJ 07065, United States Tel: 732 574-9000 Fax: 732 574-2634 Email: [email protected] FCC Confidential Authorization Date: 2020-05-12 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: EMOIZBT110A In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, SDI Technologies Inc. , hereby requests long-term confidential treatment of information accompanying this application as outlined below:  Block Diagram  Schematics  Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: David Stetin Compliance Officer

Cover Letter(s)

QA-FR-170-B 7/29/2014 SDI Technologies Inc. ADD: 1299 Main St. Rahway NJ 07065, United States Tel: 732 574-9000 Fax: 732 574-2634 Email: [email protected] FCC Authorization Date: 2020-05-12 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, SDI Technologies Inc., the undersigned, Hereby authorizes Bay Area Compliance Laboratories Corp to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: David Stetin Compliance Officer

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS

ID Label/Location Info

EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Battery Label

Test Report

Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “★”. BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.247 TEST REPORT For SDI Technologies Inc. 1299 Main St. Rahway, NJ 07065, United States FCC ID: EMOIZBT110A Report Type: Original Report Product Type: Portable Meditative Light & Sound Therapy Candle Re port Number: RSZ200427K06-00A Re port Date: 2020-06-05 Reviewed B y: Jimmy Xiao RF En gineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A FCC Part 15.247 Page 2 of 29 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 SPECIAL ACCESSORIES ................................................................................................................................................. 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 6 EXTERNAL I/O CABLE .................................................................................................................................................. 6 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 7 SUMMARY OF TEST RESULTS ............................................................................................................................... 8 TEST EQUIPMENT LIST ........................................................................................................................................... 9 FCC §15.247 (i) & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ........................................................ 10 APPLICABLE STANDARD ............................................................................................................................................ 10 RESULT ...................................................................................................................................................................... 10 FCC §15.203 – ANTENNA REQUIREMENT .......................................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 11 FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS ..................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 EUT SETUP ................................................................................................................................................................ 12 EMI TEST RECEIVER SETUP ....................................................................................................................................... 12 TEST PROCEDURE ..............................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 1 of 24 Appendix A: 20dB Emission Bandwidth Test Result TestMode Antenna Channel 20db EBW[MHz] Limit[MHz] Verdict DH1 Ant1 2402 0.840 20 PASS 2441 0.840 20 PASS 2480 0.843 20 PASS 2DH1 Ant1 2402 1.278 20 PASS 2441 1.275 20 PASS 2480 1.275 20 PASS 3DH1 Ant1 2402 1.248 20 PASS 2441 1.245 20 PASS 2480 1.248 20 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 2 of 24 Test Graphs DH1_Ant1_2402 DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 3 of 24 DH1_Ant1_2480 2DH1_Ant1_2402 2DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 4 of 24 2DH1_Ant1_2480 3DH1_Ant1_2402 3DH1_Ant1_2441 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 5 of 24 3DH1_Ant1_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 6 of 24 Appendix B: Maximum conducted Peak output power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict DH1 Ant1 2402 3.56 <=20.97 PASS 2441 4.37 <=20.97 PASS 2480 4.75 <=20.97 PASS 2DH1 Ant1 2402 5.65 <=20.97 PASS 2441 5.86 <=20.97 PASS 2480 6.50 <=20.97 PASS 3DH1 Ant1 2402 5.72 <=20.97 PASS 2441 5.93 <=20.97 PASS 2480 6.60 <=20.97 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 7 of 24 Appendix C: Carrier frequency separation Test Result TestMode Antenna Channel Result[MHz] Limit[MHz] Verdict DH1 Ant1 Hop 1.000 >=0.560 PASS 2DH1 Ant1 Hop 1.003 >=0.850 PASS 3DH1 Ant1 Hop 1.003 >=0.830 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 8 of 24 Test Graphs DH1_Ant1_Hop 2DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 9 of 24 3DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 10 of 24 Appendix D: Time of occupancy Test Result TestMode AntennaChannel BurstWidth [ms] TotalHops [Num] Result[s]Limit[s] Verdict DH1 Ant1 Hop 0.40 320 0.128 <=0.4 PASS DH3 Ant1 Hop 1.65 110 0.181 <=0.4 PASS DH5 Ant1 Hop 2.90 80 0.232 <=0.4 PASS 2DH1 Ant1 Hop 0.40 290 0.115 <=0.4 PASS 2DH3 Ant1 Hop 1.64 100 0.164 <=0.4 PASS 2DH5 Ant1 Hop 2.88 70 0.202 <=0.4 PASS 3DH1 Ant1 Hop 0.40 320 0.127 <=0.4 PASS 3DH3 Ant1 Hop 1.64 100 0.164 <=0.4 PASS 3DH5 Ant1 Hop 2.88 70 0.202 <=0.4 PASS Note 1:A period time=0.4*79=31.6(S), Result=BurstWidth*Totalhops Note 2: Totalhops=Hopping Number in 3.16s*10 Note 3: Hopping Number in 3.16s=Total of highest signals in 3.16s(Second high signals were other channel) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 11 of 24 Test Graphs DH1_Ant1_Hop DH3_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 12 of 24 DH5_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 13 of 24 2DH1_Ant1_Hop 2DH3_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 14 of 24 2DH5_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 15 of 24 3DH1_Ant1_Hop 3DH3_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 16 of 24 3DH5_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 17 of 24 Appendix E: Number of hopping channels Test Result TestMode Antenna Channel Result[Num] Limit[Num] Verdict DH1 Ant1 Hop 79 >=15 PASS 2DH1 Ant1 Hop 79 >=15 PASS 3DH1 Ant1 Hop 79 >=15 PASS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 18 of 24 Test Graphs DH1_Ant1_Hop 2DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 19 of 24 3DH1_Ant1_Hop Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 20 of 24 Appendix F: Band edge measurements Test Graphs DH1_Ant1_Low_2402 DH1_Ant1_High_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 21 of 24 DH1_Ant1_Low_Hop_2402 DH1_Ant1_High_Hop_2480 2DH1_Ant1_Low_2402 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 22 of 24 2DH1_Ant1_High_2480 2DH1_Ant1_Low_Hop_2402 2DH1_Ant1_High_Hop_2480 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 23 of 24 3DH1_Ant1_Low_2402 3DH1_Ant1_High_2480 3DH1_Ant1_Low_Hop_2402 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ200427K06-00A Page 24 of 24 3DH1_Ant1_High_Hop_2480

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Radiated Emissions View (Below 1 GHz) Radiated Emissions View (Above 1 GHz)

Contact Information

Applicant

David Stetin(Compliance Officer)
[email protected]732 574-9000Fax: 732 574-2634

Test Firm

Bay Area Compliance Laboratories Corp. (Shenzhen)Well Wang
[email protected]+86 (0) 755 33320018

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz5.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from SDI Technologies Inc.

Magnetic Wallet Power Bank - FCC ID EMOIPCV3A - SDI Technologies Inc.
EMOIPCV3A

Magnetic Wallet Power Bank

May 27, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
ALARM CLOCK WITH NIGHTLIGHT AND FAST WIRELESS CHARGING - FCC ID EMOTW502A - SDI Technologies Inc.
EMOTW502A

ALARM CLOCK WITH NIGHTLIGHT AND FAST WIRELESS CHARGING

Apr 22, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Bluetooth Karaoke - FCC ID EMO555B - SDI Technologies Inc.
EMO555B

Bluetooth Karaoke

Nov 23, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Karaoke - FCC ID EMO555BM - SDI Technologies Inc.
EMO555BM

Bluetooth Karaoke

Nov 23, 2025

Equipment Class

DTS - Digital Transmission System
Bluetooth Alarm Clock with wireless and USB charging - FCC ID EMOIBTW112A - SDI Technologies Inc.
EMOIBTW112A

Bluetooth Alarm Clock with wireless and USB charging

Sep 07, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter