
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Calibration software operation manual V.1.01 Aug 15 2002 -1- INDEX 1. Introduction2 (1) System configuration2 (2) Calibration software installation2 2. Calibration software3 (1) Program execution3 (2) CONNECT3 (3) SCALE4 (4) OFFSET4 (5) Draw4 (6) Test 45 (7) Test 485 (8) Manual adjustment6 (9) SIG ADJ (Signal adjustment)6 (10) HELP6 3. Uninstallation7 (1) Program execution7 -2- 1. Introduction (1) System configuration Please confirm the following hardware, software. )1Personal computer (PC 2TouchScreen 3Installation CD Figure 1: System configuration (2) Calibration software installation Executeof."setup.exe""Installation CD" When a CD drive is,will be executed automatically."Autorun mode" "setup.exe" Follow the instructions of."setup.exe" Figure 2: Setup folder setup.exe If figure 3 is displayed, clickbutton."Next> " Figure 3: Setup.exe If figure 4 is displayed, clickbutton. "Finish" Figure 4: Setup finish. -3- 2. Calibration software (1) Program execution Start -> Programs -> Calibration -> CalibrationSelect or Selectshortcut. "Calibration" Figure 5: Calibration software (2) CONNECT When figure 5 is displayed, confirm, and clickbutton."Serial setting""CONNECT" When connection is successful, figure 6 and figure 7 are displayed. When other software are using the COM port, it does not connect. In this case, change the COM port. If it has only one COM port, change the baud rate of current installed driver, so COM port become free, then can connect. Figure 6: Trial of connection Figure 7:Connection success Default "Serial setting" value are "9600bps", "parity none", "COM1 port" , and "MTS" format. Baud rate is fixed at 9600 and Parity none. -4- (3) SCALE Whenbutton is clicked, scale window is shown with."SCALE""+ cursor" "+ cursor". When figure 8 is displayed, touch center of Keep touchingtillbecomes full. "+ cursor""progress meter" Figure 9: progress meter Figure 8: SCALE window (4) OFFSET Whenbutton is clicked, offset window is shown with."OFFSET""+ cursor" "+ cursor". When figure 10 is displayed, touch center of Keep touchingtillbecomes full. "+ cursor""progress meter" Figure 11: progress meter Figure 10: OFFSET window (5) Draw Whenbutton is clicked, draw window is shown."Draw" When figure 12 is displayed, touch tablet, and you can trace graphics. Figure 12: DRAW window -5- (6) Test 4 Whenbutton is clicked,window is shown."Test4""Test 4" "+ cursor". When figure 13 is displayed, touch center of Keep touchingtillbecomes full. "+ cursor""progress meter" Figure 15 is displayed when you input four points. Figure 14: progress meter Figure 13: Test4 window 1 Figure 15: Test4 window 2 (7) Test 48 Whenbutton is clicked,window is shown."Test48""Test 48" "+ cursor". When figure 16 is displayed, touch center of Figure 16: Test48 window -6- (8) Manual adjustment Setting values of SCALE and OFFSET are changed when you pushandbutton."+ ""-" You can adjust four kinds of setting values. 1Scale of X coordinate 2Scale of Y coordinate 3Offset of X coordinate 4Offset of Y coordinate "Trial""+ ""-"Clickbutton to memorize last setting after having adjusted setting values byand button. Pushbutton if you don’t expect modification. "Default" It is completed when you pushbutton."OK" Figure 17: Manual adjustment (9) SIG ADJ (Signal adjustment) Whenbutton is clicked,window is shown. (Figure 18)"SIG ADJ""SIG ADJ" It have been adjusted Ex-factory and unnecessary for general users to activate it. Figure 18: SIG ADJ window (10) HELP Whenbutton is clicked,window is shown. (Figure 19)"HELP""HELP" Figure 19: HELP window -7- 3. Uninstallation (1) Program execution Start -> Settings -> Control Panel -> Add/Remove ProgramsSelect: Figure20: Uninstallation program Add/Remove Programs Properties appears. Figure 21 Selectand click or tapbutton. "Touch screen Calibration""Add/Remove..." Figure 21: Add/Remove Programs Properties If figure 22 is displayed , clickbutton. "Yes" Figure 22: Windows Installer
FCC ID. : EU6PTD-1800D File No. : E03NR-006 ONETECH Testing & Evaluation Lab. FCC ID. : EU6PTD-1800D File No. : E03NR-006 ONETECH Testing & Evaluation Lab. FCC ID. : EU6PTD-1800D File No. : E03NR-006 ONETECH Testing & Evaluation Lab. FCC ID. : EU6PTD-1800D File No. : E03NR-006 ONETECH Testing & Evaluation Lab.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Glass Touch Screen
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
JBP - Part 15 Class B Computing Device Peripheral
Equipment Class
JBP - Part 15 Class B Computing Device PeripheralJBP - Part 15 Class B Computing Device Peripheral
Equipment Class
JBP - Part 15 Class B Computing Device PeripheralCables connected to the stylus pen port of the referenced device must be shielded
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral