Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
v 2651 1 When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury, including the following: 1.Read and understand amage to the product. 2.Slots and openings in the cabinet and the back or bottom are provided for ventilation. To protect it from overheating, these openings must not be blocked by placing the product on the bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation where proper ventila tion is not provided. 3.This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your dealer or local power company. 4.Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by persons walking on it. 5.Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product. 6.To reduce the risk of electric shock, do not disassemble this product, but take it to an authorized service facility. Opening or removing cabinet parts other than specified access doors may expose you to dangerous voltages or other risks. Incorrect reassemb-ling can cause electric shock when the appliance is subsequently used. 7.Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock. Important Safety Instructions 2 12.Unplug this product from the wall outlet and refer servicing to a VTech authorized service facility under the following conditions: A. When the power supply cord or plug is damaged or frayed. B. If liquid has been spilled into the product. C. If the product has been exposed to rain or water. D. If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions, because improper adjustment of other controls may result in damage and will often require extensive work by a VTech authorized technician to restore the product to normal operation. E. If the product has been dropped and the cabinet has been damaged. F. If the product exhibits a distinct change in performance. 13.Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lighting. 14.Do not use the telephone to report a gas leak in the vicinity of the leak. VTECH COMMUNICATIONS INC SERVICE DEPT. at 1-800-595-9511. In Canada, call VTech Telecommunications Canada Ltd. at 1-800-267-7377. SAVE THESE INSTRUCTIONS 3 The v 2651 is an advanced cordless telephone that operates in the 2.4GHz frequency range. Your v 2651 is capable of supporting up to a maximum of 4 Handsets. Using additional Handsets, up to three people can be conferenced on a call (2 Handsets and the Base Speakerphone), or two extensions can be conferenced on a call, while two other extensions can be talking internally, using the Intercom feature. This manual is designed to familiarize you with the v 2651 cordless telephone. We strongly recommend you read the manual before using your phone. To order additional system Handsets(model#v2600), battery packs, or headsets, call VTech Communications Inc at 1-800-595-9511. Introduction IMPORTANT Please record the Base ID#(BS ID) printed on the underside of the 2651 Base in the space below. Please be certain to include all 15 digits/characters. Base ID # STOP!! If you have questions about this product, or if you're having difficulty with setup or operation, do not return your phone to the store. Call our Customer Support Center at 1-800-595-9511 In Canada, call 1-800-267-7377 4 Parts Check List 5Battery Pack 6.Owner's Manual 7.Wall Mounting Bracket To purchase replacement battery packs, call VTech Communications Inc at 1-800-595-9511. In Canada, call VTech Telecommunications Canada Ltd. at 1-800- 267-7377. 1.Base Unit 2.Handset 3.AC Power Adapter 4.Telephone Cord 5 The Handset Layout 1.Antenna 2.Earpiece 3.Headset Jack (2.5mm) 4.Scroll Keys 5.On (Flash) 6.Dialing Keys (0-9, *, #) 7.Handsfree Speakerphone 8.LCD Display 9.Menu/Select 10. Off (Clear) 11. Battery Compartment 12. Intercom 13. Microphone 6 1.Intercom 2.Flash 3.Mute 4.Redial 5.Charge Contacts 6.Dialing Keys (0-9, *, #) 11. DC Connector 12. Telephone Jack The Base Unit Layout !"#$%& '((') *'+,('(' ()(-.+, ,#/,0(),(''*!)!# 1(2% /23111111,('0,4(& '!2*% )56!,5%%7()&( ()( ,%$++, )* ,('()) 5+ ('0'((')!%8()&(9'),+ (',+,':'"8()&() '9(',+,',(&;(' ('0 (',+,' 9 ) ')(, ,('* ,(&9+'((')9' '),')('0() '* +(!.""<2 " & '((') *=&$22 ))" ,),' 9 , )) ' 7.Speakphone key 8.Charge Contacts 9.In Use 10.Volume 7 Setup Plug the AC power adapter into an electrical outlet, and the DC connector into the back of the base unit. > & '((') * =&$22 ))" ,),' 9 , )) ' CAUTION:Use only the VTech power supply provided with your VTech unit. IMPORTANT: FOR MAXIMUM PERFORMANCE OF YOUR CORDLESS TELEPHONE SYSTEM: 1. Choose a central location for your Base Unit. 2. Install your Base Unit and Extension Handsets away from electronic equipment, such as personal computers, television sets and microwave ovens. 3. In location…
Text truncated - open the document above for the full version.
VCO 1.2GHZ Driver PA Amp 2x PLL Mixer LNA 864kHz IF Filter BW=700KHz Limiter Demod Data Slicer RX Data 3 Wire Interface TX Data PA Control 2.4GHz Microstrip BP Filter TX/RX SW SHC RxDsg Low Pass Filter RF Block Diagram
FCC ID: EW780-5269-00 Federal Communications Commission 7435 Oakland Mills Road, Columbia, Maryland 21046 Request for Confidentiality VTech Telecommunications Ltd. would like to keep the following documents as confidential for the application of the VTech 2651/2656/2600/2665/2660 approval for FCC Part 15 submission. (1) Schematics (2) Technical description -- file name : HK- WDCT Step 6 Radio Description.doc HK- WDCT Step 6 Radio system design.doc The above documents contain information for new technology & ideas in 2.4GHz cordless telephone with digital modulation, so we would like to prevent the use of this information by other companies. Dated this 31 day of January 2003 By:_________________________________ Joseph Poon (Signature) (Printed) Title: Regulatory Compliance Manager Telephone: (604) 273-5131 Applicant: VTECH Engineering Canada Ltd.
Models using FCC ID: EW780-5269-00 : 1. VTech 2651 – 2.4 GHz Cordless phone with Base Speakerphone and Keypad 2. Vtech 2656 – 2.4 GHz Cordless phone with Base Answering Machine 3. Vtech 2600 – Handset only (from 2651 or 2656) with Standalone Charger 4. Vtech 2665 – Bundle package (2651 + 2600) 5. Vtech 2660 – Bundle package (2656 + 2600)
From: "Ruby Dulmage" <[email protected]> To: "Curtis-Straus Certification Dept." <[email protected]> Sent: Tuesday, February 18, 2003 11:59 AM Attach: 3W06736 - Part 1.pdf Sub ject: Re: VTech FCC ID: EW780-5269-00 - Answers - Part I Page 1 of 2 2/20/2003 Hi Barry: 1. I will send the test report in 2 separate emails. Part I is included in this email. Part II will be in 2nd email 2. We did not take these photos as it would damage the unit. I am waiting for a response from Joseph giving us permission to take it apart. 3. The EUT was tested at +/- 15% AC Rail Voltage. The output power did not vary. 4. Yes, radiated emission testing was conducted up to the 10th harmonic. 5. Yes, the handset was tested in three orthogonal planes. We are waiting for a reply from Joseph to see if he wants the conducted measurements done to the new frequency range. We will advise. Thanks, Ruby ----- Original Message ----- From: Curtis -Straus Certification Dept. To: Ruby Dulmage Cc: [email protected] Sent: Friday, February 14, 2003 7:11 PM Subject: VTech FCC ID: EW780-5269-00 Hi Ruby, We identified the following issues with the application: 1. Please split the test report in to two parts as the file supplied is greater than 4MB in size. 2. Please supply solder side photos of the PCBs for the base station. 3. Please justify why the voltage variation testing was done at +/- 10% rather than +/- 15% as required by 15.31(e). 4. Please confirm the radiated emission testing was conducted up to the 10th harmonic. 5. Please confirm the handset was tested in three orthogonal planes. As the CISPR22 frequency range was not used during the conducted measurements the grant will include the following grant condition - "The manufacture and importation of this device must cease on July 10, 2005, pursuant to 15.37(j) or 18.123 transition provisions adopted under FCC 02-157 (ET Docket 98-80)." Best re gards Barry C. Quinlan Certification Manager Curtis-Straus TCB Page 2 of 2 2/20/2003
Vtech 2651 Cosmetic Vtech 2651 Base PCB Vtech 2651 Base PCB Vtech 2656 Cosmetic Vtech 2656 Base PCB Vtech 2656 Base PCB Vtech 2651/2656/2660/2665 Handset PCB Vtech 2651/2656/2660/2665 Handset PCB
Radio Frequency Exposure Information For Vtech 2651 & 2656 2.4GHz Cordless Telephones Handset : Readings from test report : (1) Max. Output Power – 86.5mW (2) Duty cycle – 833us x10 / 100ms = 8.33% (measured in single slot transmission) Under the worst environment with interference, dual slot diversity (ie. enhance mode) gives the max. duty cycle on the handset Tx (ie. 8.33% x2 or 16.66%) Hence, taking the max. power output & max. duty cycle, the average effective output power is : 86.5mW x 16.66% = 14.4mW Conclusion : The average effective output power is much lower than 25mW (60/f GHz) – the low threshold for general population of the exposure category. Hence, SAR evaluation on the handset is not required. Base : Readings from test report : (1) Max. Output Power – 57mW (2) Duty Cycle – 833us x10 / 100ms = 8.33% (with single handset, single slot transmission) The phone is a TDD, FHSS. So, the worst case is actually operating with 4 transmission slots with either 4 handsets or 2 handsets under enhance mode (i.e. 8.33%*4 or 33.32%). Hence, taking the worst case, the average effective output power is : 57mW x 33.32% = 19.0mW Conclusion : The base of a cordless phone system is not normally operated close to the users as that of the handset (distance >2.5cm). Together with the low average effective output power (much lower than 50mW -- the low threshold for general population exposure category), SAR evaluation is also not required for the base. Joseph Poon Regulatory Compliance Manager VTech Engineering Canada Ltd.
Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 21 of 49 Section 5.Peak Power Output Para. No.: 15.247(b) Test Performed By: Kevin CarrDate of Test: 28 Jan. 2003 Test Results:Complied The maximum peak power output of the transmitter is 0.0865 watts. The base station RF Power did not vary with +/- 15% AC rail variations. Measurement Data:Detachable antenna? Yes No If yes, state the type of non-standard connector used at the antenna port: Handset Directional Gain of Antenna: 0 dBi or 1.0 Numeric Peak Power Output: 0.0865 watts, 19.3 dBm Field Strength: 114.6 dBμV/m @ 3m or 0.537V/m @ 3m. Base Station Directional Gain of Antenna: -1.0 dBi or 0.794 Numeric Peak Power Output: 0.057 watts, 17.6 dBm Field Strength: 111.8 dBμV/m @ 3m or 0.389 V/m @ 3m. See Attached radiated measurements.
Master: PT15CDST Date: February 12, 2002 Test Report:3W06736 Applicant:VTECH Engineering Canada Ltd. Suite 200 – 7671 Alderbridge Way Richmond, B.C., Canada V6X 1Z9 Equipment Under Test:VTECH 2651 And VTECH 2656, FHSS (EUT)Cordless Phones With Speaker Phone And Answering Machine FCC ID:EW780-5269-00 In Accordance With:FCC Part 15, Subpart C Frequency Hopping Transmitters 2400 - 2483.5 MHz Tested By:Nemko Canada Inc. 303 River Road, R.R. 5 Ottawa, Ontario K1V 1H2 Authorized By: Glen Westwell, Wireless Technologist Date:31 January 2003 Total Number of Pages:49 Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT:VTECH 2651 and VTECH 2656 Page 2 of 49 Table Of Contents Section 1. Summary Of Test Results................................................................................................................3 Section 2. General Equipment Specification....................................................................................................5 Section 3. Powerline Conducted Emissions......................................................................................................6 Section 4. Channel Seperation...........................................................................................................................12 Section 4. Occupied Bandwidth......................................................................................................................14 Section 5. Peak Power Output........................................................................................................................21 Section 6. Spurious Emissions (Radiated)......................................................................................................27 Section 7.Block Diagrams...............................................................................................................................48 Section 8.Test Equipment List........................................................................................................................49 Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT:VTECH 2651 and VTECH 2656 Page 3 of 49 Section 1.Summary Of Test Results General All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15, Subpart C, Paragraph 15.247 for Frequency Hopping Spread Spectrum devices. Radiated tests were conducted is accordance with ANSI C63.4-1992. Radiated emissions are made on an open area test site. A description of the test facility is on file with the FCC. THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. The RF Circuitry in the VTECH 2651 and VTECH 2656 are identical, therefore only the VTECH 2651 was tested for radiated emissions associated with the fundamental frequency of transmission. See “ Summary of Test Data”. TESTED BY: ______________________________DATE: 31 January 2003 Kevin Carr, EMC Technologist Nemko Canada Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT:VTECH 2651 and VTECH 2656 Page 4 of 49 Summary Of Test Data Name Of TestPara. No.Result Powerline Conducted Emissions15.207 (a)Complied Occupied Bandwidth15.247 (a)(2)Complied Peak Power Output15.247 (b)Complied Spurious Emissions (Antenna Conducted)15.247 (c)N/A Spurious Emissions (Radiated)15.247 (c)Complied Transmitter Power Density15.247 (d)Complied Footnotes For N/A’s: No Access Port Test Conditions: IndoorTemperature:20°C Humidity:20% Outdoor Ottawa:Temperature:-10°C Humidity: 30% Almonte:Temperature:7°C Humidity: 65% Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 5 of 49 Section 2.General Equipment Specification Manufacturer:VTech Engineering Canada Ltd. Xia Ling Bei Management Zone, Liaobu, Dongguan, guangdong, China 523411 Model/Serial No.: Base M/N: 2651, S/N:PA 12/12 109 Base M/N: 2656, S/N: PA 12/02 111 Handset S/N: 12/02 111 Date Received In Laboratory: 9 Jan. 2003 Nemko Identification No.: 1, 2, 3 Frequency Range: 2401.056-2482.272MHz Tunable Bands: 1 Number of Channels: 17 Min. Channel Spacing: 858kHz Emissions Designator: 813k0F1D User Frequency Adjustment: None Measured Output Power: Base 0.057 Watts, 17.6 dBm Handset 0.0865 Watts, 19.3dBm Rated Output Power: Base +19.5dBm +/- 1 dB Handset +19.5dBm +/- 1 dB Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 6 of 49 Section 3.Powerline Conducted Emissions Para. No.: 15.207(a) Test Performed By: Kevin CarrDate of Test: 20 Jan. 2003 Test Results:Complied Measurement Data:See attached graph. Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 7 of 49 Conducted Disturbance at Mains Port Test Data: Test Date: 20 Jan. 2003 Engineer’s Name: Kevin Carr Temperature (C°): 20 Humidity %: 20 Tested as per (Table Top/Floor Standing): Table Top Spectrum plots for each frequency band can be found at the back of this section. Any Emissions that were above or within 5 dB of the average limits were remeasured with a receiver and recorded. . *All plots were generated with a peak detector. Port under test: AC Mai…
Text truncated - open the document above for the full version.
Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 26 of 49 Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 27 of 49 Section 6.Spurious Emissions (Radiated) Para. No.: 15.247(c) Test Performed By: Kevin CarrDate of Test: 22 Jan. 2003 Test Results:Complied. The worst-case emission level is 37.0dBμV/m @ 3m at 38.37MHz. This is 3.0 dB below the specification limit. Measurement Data:See attached graphs. Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 28 of 49 Radiated Disturbance Test Data: Digital Emissions, VTECH 2656 Test Date: 22 Jan 2003 Engineer’s Name: Kevin Carr Temperature (C°): -10 Humidity %: 30 Tested as per (Table Top/Floor Standing): Table Top Test Distance (meters): 3Range: Ottawa, Range 1 Emissions within 20 dB of the limit have been recorded. Pre-scan data can be found at the back of this section Freq. (MHz) Ant.Pol. V/H RCVD Signal (dBμV) Ant. Factor (dB) Amp. Gain (dB) Cable Loss (dB) Field Strength (dBμV/m) Limit (dBμV/m) Margin (dB) DetectorAmp. 41.4700BC1V13.311.3N/A1.125.740.014.3Q-PeakNone 41.4700BC1H7.412.8N/A1.121.340.018.7Q-PeakNone 38.0000BC1V9.811.7N/A1.122.640.017.4Q-PeakNone 38.0000BC1H11.713.4N/A1.126.240.013.8Q-PeakNone 248.7000BC1V10.716.8N/A2.830.346.015.7Q-PeakNone 248.7000BC1H15.516.1N/A2.834.446.011.6Q-PeakNone 155.5200BC1V12.313.3N/A2.127.743.515.8Q-PeakNone 155.5200BC1H17.112.9N/A2.132.143.511.4Q-PeakNone 51.8410BC1V14.910.2N/A1.126.340.013.7Q-PeakNone 51.8410BC1H9.710.9N/A1.121.840.018.2Q-PeakNone 238.4610BC1V10.516.8N/A2.730.046.016.0Q-PeakNone 238.4610BC1H9.915.8N/A2.728.446.017.7Q-PeakNone 217.7200BC1V11.915.7N/A2.630.146.015.9Q-PeakNone 217.7200BC1H10.315.2N/A2.628.146.017.9Q-PeakNone 497.6630LP1V8.817.9N/A4.130.846.015.2Q-PeakNone 497.6630LP1H8.819.0N/A4.131.946.014.1Q-PeakNone 300.7100LP1V12.414.5N/A3.130.046.016.0Q-PeakNone 300.7100LP1H8.115.8N/A3.127.046.019.0Q-PeakNone 539.1360LP1V9.518.4N/A4.232.146.013.9Q-PeakNone 539.1360LP1H10.118.8N/A4.233.146.012.9Q-PeakNone 476.9290LP1V8.717.8N/A3.930.346.015.7Q-PeakNone 476.9290LP1H7.618.0N/A3.929.446.016.6Q-PeakNone 705.0230LP1V8.821.6N/A4.835.246.010.8Q-PeakNone 705.0230LP1H7.021.8N/A4.833.746.012.4Q-PeakNone 663.5560LP1V10.221.0N/A4.735.946.010.1Q-PeakNone 663.5560LP1H7.420.9N/A4.733.046.013.0Q-PeakNone Note 1: Antenna Legend: BC = Biconical, BL = Bilog, LP = Log-Periodic, Horn = Horn, ED = EMCO Dipole Note 2: Detector Legend: Q-Peak = 120 kHz RBW, Average = 1.0 MHz RBW Notes: Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 29 of 49 Radiated Disturbance Test Data: Digital Emissions, VTECH 2651 Test Date: 22 Jan 2003 Engineer’s Name: Kevin Carr Temperature (C°): -10 Humidity %: 30 Tested as per (Table Top/Floor Standing): Table Top Test Distance (meters): 3Range: Ottawa, Range 1 Emissions within 20 dB of the limit have been recorded. Pre-scan data can be found at the back of this section Freq. (MHz) Ant.Pol. V/H RCVD Signal (dBμV) Ant. Factor (dB) Amp. Gain (dB) Cable Loss (dB) Field Strength (dBμV/m) Limit (dBμV/m) Margin (dB) DetectorAmp. 51.8890BC1V16.410.2N/A0.827.540.012.5Q-PeakNone 51.8890BC1H13.610.9N/A0.825.340.014.7Q-PeakNone 39.6400BC1V19.111.5N/A0.831.440.08.6Q-PeakNone 39.6400BC1H17.313.2N/A0.831.340.08.7Q-PeakNone 38.3700BC1V24.611.7N/A0.837.040.03.0Q-PeakNone 38.3700BC1H22.013.4N/A0.836.140.03.9Q-PeakNone 62.2000BC1V19.79.0N/A0.929.640.010.4Q-PeakNone 62.2000BC1H13.49.2N/A0.923.540.016.5Q-PeakNone 51.5900BC1V17.210.3N/A0.828.340.011.7Q-PeakNone 51.5900BC1H19.411.0N/A0.831.240.08.8Q-PeakNone 155.3800BC1V12.013.3N/A1.526.843.516.7Q-PeakNone 155.3800BC1H6.712.9N/A1.521.143.522.4Q-PeakNone 37.3560BC1V21.811.8N/A0.834.440.05.6Q-PeakNone 37.3560BC1H13.413.5N/A0.827.740.012.3Q-PeakNone 72.6600BC1V15.28.8N/A1.025.040.015.0Q-PeakNone 72.6600BC1H17.48.6N/A1.027.040.013.0Q-PeakNone 497.6650LP1V6.517.9N/A2.927.346.018.7Q-PeakNone 497.6650LP1H8.419.0N/A2.930.346.015.7Q-PeakNone 476.9280LP1V7.517.8N/A2.828.146.017.9Q-PeakNone 476.9280LP1H6.318.0N/A2.827.146.018.9Q-PeakNone 435.4570LP1V6.916.4N/A2.726.046.020.0Q-PeakNone 435.4570LP1H9.816.8N/A2.729.346.016.7Q-PeakNone 518.4000LP1V7.318.8N/A2.929.046.017.0Q-PeakNone 518.4000LP1H6.519.3N/A2.928.746.017.4Q-PeakNone 559.8730LP1V3.018.9N/A3.125.046.021.0Q-PeakNone 559.8730LP1H8.319.3N/A3.130.746.015.3Q-PeakNone 311.0410LP1V8.115.4N/A2.325.846.020.2Q-PeakNone 311.0410LP1H15.715.7N/A2.333.746.012.3Q-PeakNone Note 1: Antenna Legend: BC = Biconical, BL = Bilog, LP = Log-Periodic, Horn = Horn, ED = EMCO Dipole Note 2: Detector Legend: Q-Peak = 120 kHz RBW, Average = 1.0 MHz RBW Notes: Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 30 of 49 Radiated Disturbance Test Data: VTECH 2651 Base Station Harmonics, Average Test Date: 22 Jan 2003 Engineer’s Name: Kevin Carr Temperature (C°): -10 Humidity %: 30 Tested as per (Table Top/Floor Standing): Table Top Test Distance (meters): 3Range: Ottawa, Range 1 Emissions within 20 dB of the limit have been recorded. Pre-scan data can be found at the back of this section Freq. (MHz) Ant.Pol. V/H RCVD Signal (dBμV) Ant. Factor (dB) Amp. Gain (dB) Duty Cycle Corr. Factor (dB) Cable Loss (dB) Field Strength (dBμV/m) Limit (dBμV/ m) Margin (dB) Amp. Ch. 47 4883.3100Horn1V72.634.454.920.08.040.154.013.94-8GHz 4883.3900Horn1H75.334.254.920.08.042.654.011.44-8GHz 7325.3500Horn1V71.236.556.020.011.943.654.010.44-8GHz 7324.8500Horn1H72.136.556.020.011.944.554.09.54-8GHz Ch. 00 4802.0500Horn1V68.634.355.220.07.335.154.018.94-8GHz 4802.2200Horn1H74.334.155.220.07.340.654.013.44-8GHz 7203.1100Horn1V69.736.556.020.012.542.754.011.34-8GHz 7203.8100Horn1H71.236.556.020.012.544.254.09.84-8GHz Ch. 94 4964.5400Horn1V72.234.454.…
Text truncated - open the document above for the full version.
Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002 Conducted Disturbance at Mains Port Conducted Disturbance at Mains Port Test Data: Test Date: 18 Feb. 2003 Engineer’s Name: Kevin Carr Temperature (C°): 21 Humidity %: 07 Tested as per (Table Top/Floor Standing): Table Top Spectrum plots for each frequency band can be found at the back of this section. Any Emissions that were above or within 5 dB of the average limits were remeasured with a receiver and recorded. . * All plots were generated with a peak detector. Port under test: AC Port Test Voltage: 120VAC Receiver Results (if applicable) : Conductor Frequency (MHz) Detector Level dB(μV) Limit dB(μV) Margin dB No peak emissions with 3dB of the Average Limit VTECH 2656 deemed worst case, EUT tested while charging flat batteries Notes: Conducted Disturbance at Mains Port Results: Final Test Result ( Please Check One): Pass Fail Were their deviations from the standard test procedure? Yes No If yes, document: Has rented equipment been used? Yes No If yes, document: S/W Ver. Not supplied by client Exercise Program: The mode used to exercise the various system components in a manner similar to typical use. Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002 Conducted Disturbance at Mains, continued Conducted Disturbance at Mains Test Equipment Used: Conducted Disturbance at Mains Test Equipment Used: CAL Cycle Equipment Manufacturer Model No. Asset/Serial No. 1 Year LISN EMCO 4825/2 FA001545 1 Year LISN(peripheral) Tegam 95300-50 FA000986 1 Year LISN(peripheral) Tegam 95300-50 FA000986 1 Year Receiver Rohde & Schwarz ESH3 FA000872 Extended Spectrum Analyzer Hewlett-Packard 8566B FA001309 Extended Spectrum Analyzer Display Hewlett-Packard 85662A FA001309 1 Year Transient Limiter Hewlett-Packard 1194 7A FA000975 Note: N/A = Not Applicable, NCR = No Cal Required, COU = CAL On Use, OUT = Out For CAL/Repair Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002 Conducted Disturbance at Mains, continued Conducted Disturbance at Mains Detailed Setup Photos: Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002 Conducted Disturbance at Mains, continued Conducted Disturbance at Mains Plots: Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002 Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002 Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002 Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002 Reference Standard: CISPR 22:1997-11 Quote Number: 3W06736 Nemko Canada Inc. Logbook Equipment (EUT): VTECH 2656 Release 1.1, Date: September 24, 2002
Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 45 of 49 Set up Photo’s, Digital Emissions Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 46 of 49 Set up Photo’s, Base Nemko Canada Inc.FCC PART 15, SUBPART C FREQUENCY HOPPING TRANSMITTERS PROJECT NO.:3W06736 EQUIPMENT: VTECH 2651 and VTECH 2656 Page 47 of 49 Set up Photo’s Handset
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 86.50 mW |

Video Baby Monitor
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Video Baby Monitor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Video Baby Monitor
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
SIP cordless hotel phone
Equipment Class
PUB - Part 15 Unlicensed PCS Base Station
Video Baby Monitor
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter