FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. IKEA of Sweden AB/
  3. FHO-LED2010R3K5

FHO-LED2010R3K5Self-Ballasted LED-lamp

IKEA of Sweden AB
Self-Ballasted LED-lamp - FCC ID FHO-LED2010R3K5 - IKEA of Sweden AB
Click to zoom

Application Details

Equipment Class
JAB - Part 15 Class B Digital Device
Date of Grant
Apr 18, 2021
Application Purpose
Original Equipment
Date of Application
Apr 18, 2021
Equipment Note
Self-Ballasted LED-lamp
Company
IKEA of Sweden AB
Country
Sweden

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC part 15 English This device complies with Part 15 of the FCC Rules/Innovation Science and Economic Development Canada's licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. WARNING: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Français Cet appareil est conforme à l’article 15 du règlement de la FCC, ainsi qu’aux normes d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. Son fonctionnement est autorisé aux deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage, (2) l’appareil doit accepter tout brouillage radioélectrique subi, même si cela est susceptible de compromettre son fonctionnement. ATTENTION : Tout changement ou modification apportés à cet appareil sans approbation expresse de la partie responsable de la conformité peut rendre nulle la capacité de l’utilisateur à utiliser cet appareil. REMARQUE : Cet appareil a été testé et il est conforme aux exigences relatives aux appareils électroniques de classe B, selon la section 15 des règles de la FCC (Commission fédérale des communications). Ces exigences sont prévues pour fournir une protection raisonnable contre les interférences nuisibles dans le cas d’une installation domestique. Cet appareil génère, utilise et peut émettre de l’énergie sous forme de fréquences radio. Si l’appareil n’est pas installé ou utilisé conformément aux instructions, il peut provoquer des interférences perturbant les communications radio. Il est cependant impossible de garantir l’absence totale d’interférences d’une installation donnée. Si cet appareil produit des interférences nuisibles à la réception radio/télévision, ce qui peut-être déterminé en mettant successivement l’appareil sous tension et hors tension, nous conseillons à l’utilisateur d’essayer de remédier à ce problème en suivant l’une des procédures suivantes : • Réorienter ou déplacer l’antenne de réception. • Augmenter la distance entre l’appareil et le récepteur. • Brancher l’appareil à une prise placée sur un circuit différent de celui auquel le récepteur est raccordé. • Contacter votre revendeur ou tout technicien radio/TV qualifié pour obtenir de l’aide. Español Este aparato es conforme al artículo 15 del reglamento de la FCC, así como a las normas de Innovación, Ciencia y Desarrollo económico de Canadá aplicables a los aparatos de radio exentos de licencia. Su funcionamiento está sujeto a las dos condiciones siguientes: (1) El aparato no debe producir interferencias dañinas y (2) el aparato debe aceptar cualquier interferencia que reciba, incluidas las que puedan determinar el funcionamiento no deseado del mismo. ATENCIÓN: Cualquier cambio o modificación que se realice en este aparato sin la aprobación expresa de la parte responsable de la conformidad puede anular la capacidad del usuario para utilizar el aparato. NOTA: Este equipo ha sido probado para comprobar que cumple los límites establecidos en los dispositivos digitales de Clase B, según el apartado 15 del reglamento FCC. Estos límites se han establecido para proporcionar una protección razonable contra las interferencias perjudiciales en una instalación doméstica. Este equipo genera, usa e irradia energía de radiofrecuencia, y si no se instala y se usa de acuerdo con las instrucciones, puede causar interferencias perjudiciales en las comunicaciones por radio. Sin embargo no existe garantía de que no se produzcan interferencias en una instalación en concreto. Si el equipo produjera interferencias perjudiciales en la recepción de radio o TV, lo que se puede comprobar encendiendo y apagando el equipo, recomendamos al usuario que intente corregir dichas interferencias adoptando una o más de las siguientes medidas: • Reorientar o recolocar la antena receptora. • Aumentar la distancia entre el equipo y el receptor. • Conectar el equipo a un enchufe o circuito distinto al que esté conectado el receptor. • Solicitar ayuda al vendedor o a un técnico cualificado de radio/TV. © Inter IKEA Systems B.V. 2020 AA-xxxxxxx-1

Users Manual

5000 SOLHETTA LED 573 40 cd 37 mA 120 V~ 60 Hz CRI > 90 115 lm/W < 1 s x25 000 D50 mm L54 mm 3.3 W = 50 W 380 lm GU10 LED2010R3K5 SIZE:203x155mm GU10 380lm 3-pack High Kelvin 5000 K NA 25 000 h AA-xxxxxxx-x SE-343 81 Älmhult www.IKEA.com IKEA of Sweden AB ©Inter IKEA Systems B.V. 2021 ATTENTION: NE CONVIENT PAS AUX SORTIES DE SECOURS.NE PAS UTILISER AVEC DES GRAD ATEURS. RISQUE DE CHOC ÉLECTRIQUE – UTILISER DANS UN EMPLACEMENT SEC UNIQUEMENTAmpoule conçue pour utilisation en intérieur à une température ambiante comprise entre -20ºC et 25ºC.Cet équipement est conforme à la section 15 des règles de la FCC. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet équipement ne doit pas causer d’interférence nuisible et (2) cet équipement doit accepter toutes les interférences reçues, y compris celles qui peuvent causer un fonctionnement indésirable.NMB-005(B) CAUTION: THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS.DO NOT USE WITH DIMMERS.RISK OF ELECTRIC SHOCK – USE IN DRY LOCATION ONLYReliable operating temperature is -20ºC~25ºC.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005(B) PRECAUCIÓN: ESTE DISPOSITIVO NO SE DESTINA PARA USO EN SALIDAS DE EMERGENCIA. NO USAR CON ATENUAD ORES DE LUZ.RIESGO DE DESCARGA ELÉCTRICA – USAR SOLO EN LUGARES SECOSEl rango confiable de temperatura de funcionamien - to es -20 ~25 . Estas lámparas cumplen con los requisitos de etiquetado de la eficiencia energética Federal. Este aparato cumple la parte 15 de las normas FCC. Su funcionamiento está sujeto a las dos condiciones siguientes: 1.Este aparato no debe provocar interferencias perjudiciales. 2.Debe aceptar cualquier interferencia que reciba, incluidas las interferencias que puedan suponer un mal funcionamiento. US / EU Warranty / Garantie / Garantía: 3 years / 3 ans / 3 años Dimmer compatibility / Compatibilité avec un variateur d’intensité / Reguladores de intensidad compatibles : www.IKEA.com Made in China

Cover Letter(s)

April 16th, 2020 Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Subject: Limited Agency Agreement IKEA of Sweden AB FCC ID: FHO-LED2010R3K5 To Whom It May Concern: We, IKEA of Sweden AB, hereby authoriz ed Intertek Semko AB, Sweden to act as our Agent for the purpose of preparing application for FCC ID number FHO-LED2010R3K5 under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is April 1st, 2021. The Limited Agency Agreement expires on October 1st, 2021, unless sooner terminated or extended by written notice to Intertek Semko AB, Sweden and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, Ivan Susak Team Manager, Laws&Standards IKEA of Sweden AB [email protected] +4647681000 © Inter IKEA Systems B.V. 2014

Cover Letter(s)

© Inter IKEA Systems B.V. 2014 March 06th, 2021 Attention: Application Examiner RE: Request for Confidentiality Applicant: IKEA of Sweden AB FCC ID: FHO-LED2010R3K5 To Whom It May Concern: Permanent Confidentiality Request is hereby submitted by IKEA of Sweden AB to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: ď‚·Schematics ď‚·Detailed Operational/Functional Description ď‚·Block diagram ď‚·Parts list Short-term Confidentiality Request is hereby submitted by IKEA of Sweden AB to withhold from public review for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing, certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept confidential for a period of 180 days from the date of Authorization: ď‚·Test setup photos ď‚·External photos ď‚·Internal photos ď‚·User manual Rationale for request for confidentiality: IKEA of Sweden AB has invested considerable time and materials in research and development to produce the referenced product. [Permanent confidentiality: Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would © Inter IKEA Systems B.V. 2014 also disclose successful implementation of unpublished, leading edge technology developed by us.] [Short term confidentiality: Disclosure of the short-term confidential portions of this application during the period of importation and/or distribution would reveal key aspects of proprietary technology to competitors and diminish the value of our investment in research and development.] Sincerely, Ivan Susak Team Manager –Laws & standards IKEA of Sweden AB [email protected] +4647681000

External Photos

EXTERNAL PHOTO - LED2010R3K5 Revision Revision Comment No. of Changes Checked by Approved by Approved date Designed by No. of Pages 1 (1) Replaces document Description ♦ ♦ _____________________________________________________________________________________ Name Marking_LED2010R3K5 GU10 NA/CF 19972 Product Name Doc number Template Version: 3.1 MARKING Marking_19972_ LED2010R3K5 _GU10_ NA/CF Marking Position

ID Label/Location Info

Revision Revision Comment No. of Changes Checked by Approved by Approved date Designed by No. of Pages 1 (1) Replaces document Description ♦ ♦ _____________________________________________________________________________________ Name Marking_LED2010R3K5 GU10 NA/CF 19972 Product Name Doc number Template Version: 3.1 MARKING Marking_19972_ LED2010R3K5 _GU10_ NA/CF Marking Position

Internal Photos

INTERNAL PHOTO - LED2010R3K5

Test Report

IKEA of Sweden AB TEST REPORT SCOPE OF WORK EMC TESTING– LED2010R3K5 REPORT NUMBER 201019124GZU-001 ISSUE DATE [REVISED DATE] 08 January 2021 [---------------------] PAGES 16 DOCUMENT CONTROL NUMBER FCC Part 15:2019-e © 2017 INTERTEK TEST REPORT Room 02, & 101/E201/E301/ E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Telephone: +86 20 8213 9688 Facsimile: +86 20 3205 7538 www.intertek.com.cn This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Version: 02-April-2020 Page 2 of 16 FCC Part 15:2019-e Applicant Name & Address : IKEA of Sweden AB Box 702, 343 81 Älmhult, SWEDEN Manufacturing Site : Dongguan Kee Tat Lighting Limited Kai Shek Cheng DONGGUAN Guangdong Province 523000, China Intertek Report No: 201019124GZU-001 Test standards CFR 47, FCC Part 15, Subpart B:2019 Sample Description Product : Sel f-ballasted LED lamp Model No. : LED2010R3K5 Electrical Rating : 120VAC, 60Hz, 37mA, 3.3W, GU10 base, 8 pcs non-replaceable LEDs. Serial No. Not Labeled Date Received : 19 October2020 Date Test Conducted : 19 October 2020 to 08 January 2021 Prepared and Checked By Jed Guo Engineer Approved By: Sky Zhu Team Leader TEST REPORT Intertek Report No.: 201019124GZU-001 Version: 02-April-2020 Page 3 of 16 FCC Part 15:2019-e CONTENT TEST REPORT ....................................................................................................................... 1 CONTENT ......................................................................................................................... 3 1. TEST RESULTS SUMMARY ......................................................................................... 4 2. EMC RESULTS CONCLUSION...................................................................................... 5 3. LABORATORY MEASUREMENTS ................................................................................ 6 4. EQUIPMENT USED DURING TEST .............................................................................. 7 5. EMI TEST .................................................................................................................. 8 5.1 C ONDUCTED DISTURBANCE VOLTAGE AT MAINS PORTS ........................................................ 8 5.1.1 Block Diagram of Test Setup .............................................................................. 8 5.1.2 Test Setup and Procedure .................................................................................. 8 5.1.3 Limit ................................................................................................................... 9 5.1.4 Test Data and curve ......................................................................................... 10 5.2 R ADIATED EMISSION 30 MHZ -1000 MHZ...................................................................... 12 5.2.1 Block Diagram of Test Setup ............................................................................ 12 5.2.2 Test Setup and Procedure ................................................................................ 12 5.2.3 Limit ................................................................................................................. 13 5.2.4 Test Data and Curve ........................................................................................ 14 5.3 R ADIATED EMISSION ABOVE 1 GHZ ................................................................................. 16 6. PHOTO OF TEST SETUP AND EUT ............................................................................ 16 TEST REPORT Intertek Report No.: 201019124GZU-001 Version: 02-April-2020 Page 4 of 16 FCC Part 15:2019-e 1. TEST RESULTS SUMMARY Classification of EUT: Class B Test Item Standard Result Conducted disturbance voltage at mains ports CFR 47, FCC Part 15, Subpart B Pass Radiated emission (30 MHz–1 GHz) CFR 47, FCC Part 15, Subpart B Pass Radiated emission (Above 1 GHz) CFR 47, FCC Part 15, Subpart B N/A Remark: Reference publication is used for methods of measurement: ANSI C63.4:2014 Remark: 1. The symbol “N/A” in above table means Not Applicable. 2. When determining the test results, measurement uncertainty of tests has been considered. TEST REPORT Intertek Report No.: 201019124GZU-001 Version: 02-April-2020 Page 5 of 16 FCC Part 15:2019-e 2. EMC RESULTS CONCLUSION RE: EMC Testing Pursuant to FCC part 15 performed on the Self-ballasted LED lamp, Model: LED2010R3K5. We tested the Self-ballasted LED lamp, Model: LED2010R3K5 to determine if it was in compliance with the relevant standards as marked on the Test Results Summary. We found that the unit met the requirement of FCC part 15 standard when tested as received. The worst case’s test data was presented in this test report. The production units are required to conform to the initial sample as received when the units are placed on the market. TEST REPORT Intertek Report No.: 201019124GZU-001 Version: 02-April-2020…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST REPORT Intertek Report: No: 201019124GZU-001 Annex 1 Version: 10-June-2019 Page 1 of 4 FCC Part 15:2018-d ANNEX - PHOTOS OF TEST SETUP Radiated Emission (30 MHz–1000 MHz) TEST REPORT Intertek Report: No: 201019124GZU-001 Annex 1 Version: 10-June-2019 Page 2 of 4 FCC Part 15:2018-d ANNEX – PHOTOS OF EUT Overall view Overall view TEST REPORT Intertek Report: No: 201019124GZU-001 Annex 1 Version: 10-June-2019 Page 3 of 4 FCC Part 15:2018-d Internal view Internal view TEST REPORT Intertek Report: No: 201019124GZU-001 Annex 1 Version: 10-June-2019 Page 4 of 4 FCC Part 15:2018-d PCBview PCBview *****************************End of Report***************************

Contact Information

Applicant

Ivan Susak(Business Area Product Engineering Manager)
[email protected]+46-766190914Fax: +46-766190914

Technical Contact

IKEA of Sweden ABCao Duong
[email protected]+4647681000

Box 702 · Almhult · Sweden

Non-Technical Contact

IKEA of Sweden ABIvan Susak
[email protected]+4647681000

Test Firm

Intertek Testing Services Shenzhen LTD., GuangzhouEmily Huang
[email protected]+86 21 50319089-232

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from IKEA of Sweden AB

FHO-E2588

BRANDHAKE

Sep 11, 2026

Equipment Class

DTS - Digital Transmission System
FHO-E2598

Table Fan

Sep 11, 2026

Equipment Class

JAV - Other Non-Digital SDoC Devices
FHO-T2504

LED Ceiling Lamp

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System
FHO-T2505

LED Fixed Lamp

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System
FHO-E2706
Jul 31, 2026